Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCHEDULE \\"A\\" Part-I (Building/Structures) (To be quoted by the tenderer) |
| 2 | Item No 01 : Design and construction of Single Men Barracks incl Cook House and Dining hall For Agniveers. Complete all specified in soil bearing capacity report, design basis report drawings and tender documents. |
| 3 | Sch 'A' Part-II (External Electric Supply) Lump sum price worked out by the contractor for (External Electric Supply) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES. |
| 4 | Sch 'A' Part-III (External Water Supply) Lump sum price worked out by the contractor for (External Water Supply) as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES. |
| 5 | Sch 'A' Part-IV (Road, Path Curvert) Lump sum price worked out by the contractor for (Road, Path Curvert) as listed in Schedule 'A' Part-IV against the lump sum price inserted by the MES. |
| 6 | Sch 'A' Part-V (Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES. |
| 7 | Sch 'A' Part-VI (Area Drainage) Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES. |
| 8 | Sch 'A' Part-VII (Site Clearance) Lump sum price worked out by the contractor for (Site Clearance) as listed in Schedule 'A' Part-I against the lump sum price inserted by the MES. |
| 9 | Sch 'A' Part-VIII (Summer & Cooling Appliances) Lump sum price worked out by the contractor for (Summer & Cooling Appliances) as listed in Schedule 'A' Part-VIII against the lump sum price inserted by the MES. |
| 10 | Sch 'A' Part-IX (Lightening Protection System) Lump sum price worked out by the contractor for (Lightening Protection System) as listed in Schedule 'A' Part-IX against the lump sum price inserted by the MES. |
| 11 | Sch 'A' Part-X (Fire Fighting System) Lump sum price worked out by the contractor for (Fire Fighting System) as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES. |
| 12 | Sch 'A' Part-XI (Internal Water Supply) Lump sum price worked out by the contractor for (Internal water supply) as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES. |
| 13 | Sch 'A' Part-XII (Internal Electric Supply) Lump sum price worked out by the contractor for (Internal Electric supply) as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES. |
| 14 | Note for Srl No 2 to 15The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 15 by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule |
| 15 | Schedule 'A' Part-XIII (Miscellaneous items of works) |
| 16 | External Electric Supply |
| 17 | Item No 04 : M& L for cable root indicator MS sheet embossed with LT 1100 Volts Volts UG made with CI Plate 6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm long including PCC work 1:2:4 type B1 of size 150x150x150 mm complete all as specified & directed |
| 18 | Item No 05 : M& L for cable root indicator MS sheet embossed with HT 11000 Volts Volts UG made with CI Plate 6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm long including PCC work 1:2:4 type B1 of size 150x150x150 mm complete all as specified & directed |
| 19 | Item No 06 : Supply, installing, testing and commissioning out door type LT Panel of suitable size, Floor mounted, CPRI approved and make given as per CA factory made totally enclosed, dust and vermin proof, shutter in front and in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and external surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in : - |
| 20 | BUSBAR :- (i) 450 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance |
| 21 | INCOMING |
| 22 | (a) MCCB 4 Pole 315 Amps, 36 KA with Rotary Handle, microprocessor release adjustable amp Ics = 100% Icu as per IEC 60947-2 , Adjustable Over load from 0.5 to 1*In , Adjustable Short Circuit from 2 to 10*Ir , Adjustable Neutral Protection - N, N/2,OFF for 4 Pole MCCB , Inbuilt Thermal Memory- 02 No (incoming) |
| 23 | (b) Digital Voltmeter 3 Phase Class-1 50Hz - 01 No. |
| 24 | (c) Digital Ammeter 3 Phase Class-1 50Hz - 01 No. |
| 25 | (d) Indicator Lamps (LED type) & bakelite fuseshowing R,Y, G phase - 01 set |
| 26 | (e) Copper wound with CTR 300/5 - 03 Nos |
| 27 | OUTGOING |
| 28 | (i) MCCB 4 Pole 200 Amps,25 KA at 415 volts - 02 No.(SM Bk + 1 No Standby) |
| 29 | (ii) MCCB 4 P 63 Amps,16 KA 415 volts - 02 Nos (DG Set Panel & Centralised Cooler) |
| 30 | (iii) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase - 02 set |
| 31 | Item No 07 : Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 32x 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 32 | Item No 08 : Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 25 X 4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 33 | Item No 09 : S&F earth continuity conductor or main earth lead of 32 X 6 mm GI strip with saddles and fixing screw etc for roof conductor and down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as directed. |
| 34 | Item No 10 : S&F earth continuity conductor or main earth lead of 25 X 3.15 mm aluminium strip with saddles and fixing screw etc for roof conductor and down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as directed. |
| 35 | Item No 11 : S & F Integral decorative LED bollard with IP 65/66 protection suitable for 10 watts LED with necessary elecrical connections with adequate size of Nuts and Bolts complete as all specified and as directed. |
| 36 | Item No 12 : Supply and fix junction box made out of polycarbonate with IP 55/IP 65 protection of size 155 x 210 x 92 mm,having terminals for termination of cable with necessary nuts and bolts, including -02 Nos polycarbonate cable gland, 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps in and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete all as directed. |
| 37 | Item No 13 : Material and labour for LT 1100 volts (Earthed) grade heat shrinkable end termination jointing kit indoor type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25-120 sqmm complete all as specified and as directed. |
| 38 | Item No 14 : Material and labour for preparation of new steel surfaces of any description over 10 cm width or girth and applying one coats of black bituminous paint complete all as specified and as directed. |
| 39 | External Water Supply |
| 40 | Item No 15 : Supplying and laying 100 mm bore Ductile iron Pressure Pipes, Centrifugally Cast (Spun), Class “K-7” with both side flanged ends confirming to IS 8329 in standard lengths with inside cement mortar lining and black bitumen external coating and including necessary DI specials as required complete all as specified and as directed. |
| 41 | Item No 16 : M&L for tapping in existing DI pipe lines 150 mm dia and inserting tee of 150x 100 mm and all as directed. |
| 42 | Item No 17 : Construction of brick masonry valve pit of size 1200 mm x 1200mm x 900 mm (internal dimensions) with one brick thick wall in cement mortar 1 : 4 on 100 mm thick PCC 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit cover 40x40x6mm angle iron frame all-round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 230x200x100mm incl provn of hinges welded with angle iron frame and MS cover 3mm thck sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in soft/loose soil complete all as shown on drawing and as specified. |
| 43 | Item No. 18 : Supply and fixing cost for MS reducer, bail plug and MS strip for centering and providing support for fixing stranded steel rope complete all as specified and directed. |
| 44 | Item No. 19 : Trial Boring/Drilling pilot boring including reaming of bore of 200mm to 300mm dia (suitable for 200mm casing upto 20m depth and 150 mm casing from 20m to bore level) IS: 2800 (part I), upto 140m to 180m depth ( if encountered hard rock which cannot be encountered at certain depth then pilot boring size can be reduced to an extent of 250 mm dia on direction of Engineer in Charge ) below ground level & lowering of MS pipe by any suitable method (by DTH-cum-rotary or reverse rig method) to depth below ground level in any type of strata/soil/rock with sand or loose boulder including disposal of materials obtained (soil, rock,etc) from boring to distance not exceeding 40 meter with & including deploying required rig, machinery, T & P equipments, etc complete all as specified and directed. |
| 45 | Item No. 20 : Supply, assembling,lowering and levelling 150 mm nominal bore MS ERW ISI marked plain end casing black pipe having wall thickness minimum 5mm IS 4270:2001/ (as per relavant IS) and jointing with electric arc welding, screwed and socketed in random length of 3 to 6 mtr, including necessary fittings i.e steel sockets, coupling, jointing and painting with two coats of bituminous paint of exterinal surfaces of pipe upto depth of 200 mtr below ground level complete all as specified and directed. |
| 46 | Item No. 21 : Supply, assembling,lowering and levelling 150 mm nominal bore MS slotted ERW ISI marked plain end casing black pipe having wall thickness minimum 5mm as per IS 8110 (2000) / IS 14270: 2001 (part 1) (as per relavant latest IS) and jointing with electric arc welding, screwed and socketed in random length of 3 to 6 mtr, including necessary fittings i.e steel sockets, coupling, jointing and painting with two coats of bituminous paint of exterinal surfaces of pipe upto depth of 200 mtr below ground level complete all as specified and directed. |
| 47 | Item No. 22 : M & L for foundation of size 100x 100 x100.0 cm at ground level for holding tube well made of plain cement concrete 1:2:4 type B-2 (using 40mm graded crushed stone aggregates) as directed by Engr-in charge (including necessary Earth work, excavation, returning filling, removal etc ). |
| 48 | Item No. 23 : Supply & Fixing of Main Submersible pump set complete which are suitable for 415 Volts, 3 Phase system, 10 HP (as suitable after carrying out yield test of bore well 75LPM to 150LPM Capacity, 50 Hz, Head 100 mtr to 150 mtr , 8 to 12 stage with delivery size of 80mm to 150mm suitable for 6\\" to 8 \\" bore complete all as specified and directed by Engr-In-Charge. |
| 49 | Item No. 24 : Supply & Fixing of Submersible cable 3 core, 10 Sqmm, PVC sheathed 1100V grade with copper conductor. |
| 50 | Item No. 25 : Simple strata box made out of 20mm thick veneered particle board and 12mm thick plywood with 25mm x 25mm aluminium angle 2mm thick base overall length min 1500 mm x 750mm x 100mm or as per reqmt with front glass sheet sliding type cover with aluminium frame all around with 2 nos key holes plates of size 40 mm x 25mm and 3 mm thick complete showing name of tube well location and strata chart of grund data showing different types of strata and selection of casing pipe complete all as specifed and directed by Eng in charge including painting of synthetic enameled paint over to a coat of wood primer. |
| 51 | Item No. 26 : Development of tube well in accordance with IS : 2800 (part I) and IS : 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, measuring static level & draw down etc. by step draw down method, including hire & labour charges of air compressor, tools & accessories etc. all as per requirement and direction of complete all as specifed and directed. |
| 52 | Item No. 27 : Supply, installation, testing and commissioning LT, 415 volt, 4 wire AC 50 Hz, cubical panel (feeder Pillar Box) factory made, out door, pedestral type, feeder pillar box, hutted roof, weather & vermin proof fabricated of 3.0mm thick MS black sheet, front & back double shutter opening type, spray two earth terminal suitable cable glands for all incoming and outgoing cable including grounting feeder pillar box 60 cm above ground level by providing 90 cm long angle iron of size 50 x 50 6mm welded on all the fours corners, embedded in PCC 1:2:4 using 20mm stone aggregate upto 30cm, complete all as specifed and directed by engr - in -charge including the following accessories / components. |
| 53 | (a) Aluminium bus bar - 200 amps rating - 03 Nos. (for phases and 100 amps for neutral 01 No. insulated with proper colour coding phase wise). qty 04 (b) incoming MCCB 4 pole 63 Amp, 415 volt, 16 KA Thermal setting 70 % to 100 % - 01 No (Incoming) Qty 02(c) Outing (i) MCCB TPN 32 Amp -05 Nos (lift & pump)(ii) MCB TPN 20 Amp -01 Nos (street light)(d) automatic star- Delta starter with single phase preventer and motor protection relay suitable for 10 HP pumps set -01 Nos(d) DOL starter 5 HP 415 volts -02 Nos (f) require necessary wiring / cable (size of cable depend upon the pump installed in the borewell) for connection of panel to a near by electric line |
| 54 | Item No. 28 : supply, installation, testing and commissioning LT, 415 volt, 4 wire AC 50 Hz, cubical panel (feeder Pillar Box) factory made, out door, pedestal type, feeder pillar box, hutted roof, weather & vermin proof fabricated of 3.0 mm thick MS black sheet, front & back double shutter opening type, spray two earth terminal suitable cable glands for all incoming and outgoing cable including grounding feeder pillar box 60 cm above ground level by prviding 90 cm long angle iron of size 50 x 60 x 6 mm welded on all the four corners, embeded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm, complete all as specified and directed by engr-in-charge including the following accessories/ components. |
| 55 | (a) Aluminium bus bar - 200 amps rating - 03 Nos. (for phases and 100 amps for neutral 01 No. insulated with proper colour coding phase wise). qty 04(b) incoming MCCB 4 pole 63 Amp, 415 volt, 16 KA Thermal setting 70 % to 100 % - 01 No (Incoming) Qty 02(c) Outing (i) MCCB TPN 32 Amp -05 Nos (lift & pump)(ii) MCB TPN 20 Amp -01 Nos (street light)(d) automatic star- Delta starter with single phase preventer and motor protection relay suitable for 10 HP pumps set -02 Nos |
| 56 | Item No. 29 : M&L for making foundation thrust blocks/support pillars for holding pipe line/clamp support etc by PCC 1:2:4 type B1 (using 20mm graded aggregate size) and using extra cement making good to surfaces complete. |
| 57 | Item No. 30 : Supply and Install of motorized Chemical Dosing suitable to inject solution upto 25 LPH comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP, 1440 RPM, assembly with agitator, dosing and agitator in single motor, agitator with SS sweep blade duly FRP coated, FRP tank 100 Ltrs capacity complete unit mounted on heavy duty MS fabricated frame duly anti corrosive paint with all accessories including UPVC pipe with valves and supportings complete all as specified and directed by Engr-In-Charge. |
| 58 | Item No. 31 : Supply only chlorine test kit with coloured ample complete with all testing fitments and OT solution in Rexene finished box complete all as directed. |
| 59 | Item No. 32 : Carrying out ground water survey to locate and identify suitable site (point) for potable and good yield water by State government approved departments/CGWB complete all as directed. |
| 60 | Item No. 33 : Material and labour for Electrologging test for borewell for finding out fluid content,porosity and permeability all as specifed and directed. |
| 61 | Item No. 34 : Testing of water sample and submission of reports for chemical and bacteriological analysis from the Government college /NABL cerified lab /State Govt Lab complete all as specified and directed. |
| 62 | Item No. 35 : Supply and filling Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in enquired grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. Please Enable Macros to View BoQ information Schedule 'A' Part-II (External Electric Supply) Item Description of Item Unit Qty Rate per unit(Rs.) Amount (Rs.) |
| 63 | Item No. 35 : Supply and filling Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in enquired grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. Please Enable Macros to View BoQ information Schedule 'A' Part-II (External Electric Supply) Item Description of Item Unit Qty Rate per unit(Rs.) Amount (Rs.) |
| 64 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes,11000 volts grade XLPE insulated (earthed), screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 120 sqmm, 3 core conforming to IS 7908 / (PART-I) 1988 with the latest amendments including jointing materials such as cable glands & lugs etc and testing on completion all as directed.Note:- Excavation, earth work, sand cushioning and cable protection shall be measured and paid separately. |
| 65 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes,1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor conforming to IS 7908 / (PART-I) 1988 with the latest amendments including jointing materials such as cable glands & lugs etc and testing on completion all as directed etc of the under mentioned type and sizes :- (a) 3.5 core x 120 sqmm RM 640.0 648.15 414816.0 (b) 2 core x 6 sqmm (Garden lighting & Post top Lantern) RM 760.0 127.61 96983.6 (c) 4 Core X 25 Sqmm (Centralised Cooler) RM 340.0 249.04 84673.6 (d) 4 Core X 16 Sqmm (for Submersible pump) RM 80.0 193.5 15480.0 |
| 66 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes,etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed. |
| 67 | M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 68 | M/L for Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed. |
| 69 | Supply and laying sand cushioning with dry and clean washed sand over and under the under ground cable in trenches, ducts for cable protection 150 mm below & 80 mm above the cable as protection of cable complete as specified & directed. Note : Punned thickness of sand shall be measured & paid. |
| 70 | Supplying and laying unreinforced precast concrete cable cover, class LV Type 2 flat, size 300mm x 180mm x 40mm complete all as specified and directed by Engr in charge. As per IS 5820:1970, cover grade shall noty be less than M-20 concrete used, average breaking load capacity 300 KG |
| 71 | Supplying and laying unreinforced precast concrete cable cover, class HV Type I, flat, size 300mm x 180mm x 40mm complete all as specified and directed by Engr in charge. As per IS 5820:1970, cover grade shall noty be less than M-20 concrete used, average breaking load capacity 300 KG |
| 72 | Supply and erecting steel tubular swaged poles complete with cast iron base plate, finial taper plug , bolts, nuts & screws complete all as specified, type 410 SP - 55 of 11 mtr long including painting of pole with one coat red oxide primer & two coat of aluminum paint & embedded portion of pole shall be painted with two coat of black paint including painting white & red alternate strips of 30 cm each externally from groundlevel uptp 1.2 m with synthetic enamel paint and writing numbering of poles with black paint on yellow background complete all as specified and as directed. |
| 73 | M&L for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as specified and dircted. |
| 74 | M&L for GI tube light grade with all fitting laid in trenches of fixed to pole of size:- (a) 50 mm Medium Grade RM 150.0 305.0 45750.0 (b) 80 mm Medium Grade RM 50.0 551.2 27560.0 |
| 75 | M&L for PCC (1:2:4) type B2 using 40 mm graded stone aggregate as in foundation, filling, mass concrete and pilasters, buttresses columns, posts etc complete all as specified & directed. |
| 76 | M&L for Precast Cement Concrete(RCC) 1:4:8 type D2 using 40 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and minimum reinforcement as per relevant IS code and set in CM 1:6 complete all as specified and directed. ( Note :Reinforcement shall be measured and paid for separately.) |
| 77 | M&L for 40 to 80mm graded broken stone aggregate for spreading/ loose filling in the substation or other places where directed including stacking materials in regular heap/ stack for measurement complete all as specified and directed. |
| 78 | S&F for lightning arrestor Expulsion type complete with all fittings, transmision/ distribution class , (RMS) discharge current 10 KA suitable for rated system voltage of 12 KV supply system with maximum continuous operating Voltage (MCOV) not less than 7.65 KV (RMS) with highly non linear ceramic resister made of Zinc Oxide in hermetically sealed container and mounting on poles including all necessary bolts, nuts and washers and making electric connection and testing on completion complete all as specified and directed.Make:- SCHNENIDER or BHEL or GE POWER or W/S INSULATORS or SOUTHERN INSULATORS or OBLUM as approved by GE. |
| 79 | Supply, installation, testing and commissioning of copper wound (double wound), step down transformer of capacity 160 KVA (Level-3), plinth/ floor mounted, OUT DOOR TYPE and conforming to IS 1180:2014, AC 3 phase 50 Hz, ONAN with external cooling tubes/ radiators, having no load voltage ratio 11/0.433 KV corresponding to principal tapping, delta connected primary side (11KV HV side) and star connected on secondery side (433V LV side) in accordence with vector symbol Dyn-11 (Vector Group), manual type off load tap changing facility on HT side to vary secondary voltage from plus 5% to Minus 10% in steps of 2.5%, continuous rating of capacity 160 KVA The transformer shall be complete with all standard fittings and accessories, gauges, first fill of tranformer oil as per IS-335, ISI marked duly filtered & dehydrated etc. Transformer shall be mounted on and including suitable platform of approx size 2.0Mx 2.0Mx 1.5M high (outer dimension) built with 150mm thick PCC 1:5:10 type E2 using 40mm graded stone aggregate as in foundation extending 150mm on both sides of wall, 350mm thick of brick masonary built in CM 1:6 using old size sub class 'B' bricks, brick masonary shall be 450mm below GL & 550mm above GL, exposed faces of brick work up to 15cm below normal ground level shall be plastered in CM 1:4 & flush in same mortar as the work proceeds on faces in contact with soil, floor shall be 100mm thick with PCC 1:2:4 type B-1 using 20mm garded stone aggregate, laid in bays over & including 100mm thick hardcore over approved earth filling, exposed plastered surfaces shall be given three coats of white wash including necessary excavation and earth work complete all as specified and directed. The unit rate of transfarmer shall also includes the cost of following accessories/ fittings :- (a) One cable box on primary (HV) side having cable glands suitable for OH conductor (consisting of 3 Nos porcelain HT bushings with brass/ gun metal bushing rods complete with nuts and washers).(b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No. cable gland suitable for reception of outgoing LT armoured cables of suitable size.(c) Oil conservator tank with filter type, drain valve and oil level gauge. (a) Externally had operated off-circuit Tap swith with position indicator and locking device(b) Conservator with oil gauge, filling hole with plug & drain hole with plug(c) Under carriage with four plain rollers(d) Oil filling hole cum air release plug- 01 No(e) Drain valve cum sampling valve- 01 No(f) Filter valve with plug- 01 No(g) Rating Plate & Diagram plate- 01 No(h) Ligting lugs for transformer- 02 No(j) Lifting lugs for lid- 02 No(k) Earthing terminals -02 No(l) Thermometer pocket- 01 No(m) Silica Gel breather- 01 No(n) Temperature rise indicator in oil 40 deg centigrade and windings 45 deg centigrade(o) Fittings accessories as per IS 1180 (part-I) 2014 Level-3 as per clause No 19.14.1.2 of SSR Part -I (q) Oil lebel gauge incl oil level min and max(r) Exclusion vent -01 No(s) 6\\" Dial type thermometer with alarm and trip contact and maximum tem -01 No(t) Mounting arrangement shall be provided with two 75x40 mm channels 460 mm long(u) Suitable plinth of height 1.5 m above GL for installation of transformer(v) Cable terminattion box on both sides (HV Side & LV side for cable connections)(w) Plinth required for mounting Tranformer as per above desriptionNote (i) The contractor shall provide BEE certified, level 3, Transformer offered by Manufacturer(ii) The contractor shall lsubmit preliminary drawing for approval of GE. |
| 80 | Supply and fixing of switch air break gang operated triple pole mechanically operated horizontal type out door with all other fittings/ accessories mounted on & including porcelain insulators and steel frame with operating mechanism worked from ground level with & including operating rod of 32mm dia GI pipe medium grade (ISI marked) with MS handle with locking arrangement, for current rating up to 400 Amp 11000 Volts including dropout fuse set 15 insulators to suit gang operated triple pole 11 KV switch, connecting, commissioning and testing on completion complete all as specified and directed. |
| 81 | M & L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size complete all as specified and directed. |
| 82 | Supply, fix for LED post top lantern 40 watt light fitting made of cast aluminium spigot housing with decorative opal acrylic diffuser with IP 65 protection complete with all accessories fixed on GI pipe 50 mm dia complete all as specified and directed. |
| 83 | Supply and fixing LED Solar street light fitting 35/36 Watt mono crystalline solar panel with MPPT features of min 216 wh cap life PO4 battery including galvanized steel octagonal pole of height 6 from ground, PCC 1:2:4 earth work PCC in built, lithium ion battery, solar panel, charge controller with dusk down sensor with all connected accessories like nuts bolts clamps etc complete all as directed. |
| 84 | Supply and fixing HT 11 KV (Earthed) grade Cold shrinkable and termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 -185 sqmm complete all as specified and as directed. |
| 85 | Materials and labour for Aluminum conductor steel reinforced (ACSR) conductor as in LT overhead electric line and stretching the same with required span, standard sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia, PG clamp etc complete all as specified and as directed. |
| 86 | Supply and fixing Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade confirming to IS-2486 complete all as specified and as directed. |
| 87 | Material and labour for anti-climbing device, spike type fabricated from structural steel comprising of MS flat 20mmx6mm, MS round bar pointed, 8mm dia, 20cm length welded on MS flat fixed with nuts, bolts, washers and welding with and including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 88 | Supply only chain link MS galvanised fencing, any size or type complete all as specified and directed. |
| 89 | Fixing only chain link fencing including line wire, any mesh, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wires complete all as specified and as directed. |
| 90 | Supply and fixing mild steel Fe 410-W (Gde-E- 250) quality-A, framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooksand hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 91 | Supply and fixing mild steel Fe 410-W (Gde-E- 250) quality-A, plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and as directed . Total carried over to BOQ Rs. 9320961.84 Signature of Contactor DY Dir (Contracts) Date: FOR ACCEPTING OFFICER Schedule 'A' Part III (External Water supply) Item Description of Item Unit Qty Rate per Unit (Rs.) Amount (Rs.) |
| 92 | Supply and lay pipe galvanized, “Medium class”, including fittings of dia 50 mm and all as directed. |
| 93 | Supply and lay pipe galvanized, “Medium class”, including fittings of dia 40 mm and all as directed. |
| 94 | Supply and lay pipe galvanized, “Medium class”, including fittings of dia 25 mm and all as directed. |
| 95 | Supply and lay pipe galvanized, “Medium class”, including fittings of dia 20 mm and all as directed. |
| 96 | S&F gun metal gate valve of following sizes screwed down high pressure with handle, Iron wheel (ISI marked) complete all as directed. (a) 50mm bore Each 6.0 979.08 5874.48 (b) 25mm bore Each 4.0 587.24 2348.96 (c ) 20mm bore Each 4.0 540.11 2160.44 |
| 97 | Supply and fix Valves, Sluice, flanged of class 1.6 PN,100 mm dia and all as directed. |
| 98 | Supply, assembling,lowering and levelling 200 mm nominal bore MS ERW ISI marked casing plain pipe having wall thickness 5.4 mm as per IS 4270:2001/ (as per relavant latest IS) and jointing with electric arc welding, screwed and socketed in random length of 3 to 6 mtr, including necessary fittings i.e sockets, coupling, jointing and painting with two coats of bituminous paint of exterinal surfaces of pipe upto depth of 200 mtr below ground level complete all as specified and directed. |
| 99 | Supply, lowering and fixing Heavy Grade GI column pipe, ISI marked both end flanged 80 mm dia bore in 3 mtr length having wall thickness as per relavant IS as per IS-1239 complete including rubber gasket, slot cutting in flanges for passing of submersible cable and nut bolts etc all as specified and directed by Engr-in-charge. |
| 100 | Supply and Fixing in position mild steel cap made of MS plate 5mm thick with an internal threading and locking arrangement having opening for column pipe and submersible cable, for housing pipe of 200 mm dia complete all as specifed and directed. |
| 101 | Supply and fixing 80mm bore Non Return Valve as perrelavant IS, PN rating 1.0 ISI marked all as specified and directed. |
| 102 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes,etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed. |
| 103 | M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 104 | M/L for Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed. Total carried over to BOQ Rs. 430019.98 Signature of Contactor DY Dir (Contracts) Date: FOR ACCEPTING OFFICER Schedule 'A' Part IV (Road, Path Curvert) Item Description of Item Unit Qty Rate per unit (Rs.) Amount (Rs.) |
| 105 | Excavating over areas, n exc 1.5 m deep and getting out soft/Hard Soil |
| 106 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil |
| 107 | Add to (or deduct from) last item for every 3 cm or part thereof above or below 15 cm average depth in soft /loose soil |
| 108 | Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point. |
| 109 | M & L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering |
| 110 | M&L for soling (sub base) with broken boulders or quarried stones 200 mm thick spread interstices filled surface formed rolled and consolidated to required gradient and camber all as spfd. |
| 111 | M & L for Laying and compacting 150 mm thick (compacted thickness ) WMM laid in two layers of 75 mm each Wet Mix Macadam (WMM) grading as pe table 400-13 of MaRTH specifications for Road and Bridge works 2013 manufactured in WMM plant material comprising of clean, crushed, graded aggregate and granular material premixed with wate to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-1 OOKN static weight and consolidating to required gradien and camber complete all as specified and directed The finished surface tolerances to be as per Table 900-1 of MaRTH specifications for Road and Bridge works 2013 complete all as specified. |
| 112 | Applying evenly a prime coat of Cationic Bitumen Emulsion SS1 confirming to IS: 8887 at a rate of application of 0. 2 - 0.30 kg/sqm on surface of bitumen including preparation of bitumen surfaces as specified in Table 500-5 of MoRTH specification for road and bridge works 2013, using mechanical sprayer complete including preparation of bitumen surfaces all as specified and directed . |
| 113 | M&L premixed bituminous macadam laid/rolled and compacted to required gradient and camber with using 20 mm graded stone agg and paving bitumen 4% by the weight of total mix (consolidate thickness 75 mm or less as required ) complete all as specified and as directed. |
| 114 | Applying evenly a prime coat of Cationic Bitumen Emulsion SS1 confirming to IS: 8887 at a rate of application of 0. 7-1 kg/sqm on surface of WMM/WBM including preparation of WBM/WMM surfaces as specified in Table 500-3 of MoRTH specification for road and bridge works 2013, using mechanical sprayer complete including preparation of WBM/WMM surfaces all as specified and directed . |
| 115 | M & L for laying bituminous premix asphaltic semi dense concrete avaraging 40mm consolidated thickness with 5.5% binder content by weight of total mix using asphalt mechanical mixer plant & consolidated with 8to 10 ton power road roller to reqd level gradient camber and super elevation. |
| 116 | Continuous edging with roughly squared sand stones of size 30 cm x 5 cm (30cm deep & 5 cm thickness), length of each patti not less than 60 cm Complete of using sand stone/Katni sone all as specified and directed. |
| 117 | M&L preparation of road surface and applying thermoplastic relflective paint in white or any tint marking of min 2 mm thick single coat as in center line and edge line road marking of 150/100 mm width using ''HOT MARK\\" thermoplastic modern propelled road marking machine as directed incl all ingredients such as blinder, glass beads, Titaniumdioxide calcium carabonate inter fillers thermroplastic requirement for glass beads shell be the Table No 650.4 of MOT specifications incl spraying of glass beads etc all as per manufactures instrustions. |
| 118 | Cement concrete type D-2 1:4:8 (using 20 mm graded aggregate) as in foundation filling and mass concrete , sub base complete all as directed. |
| 119 | Material and labour for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with aproved colour, design & attern as in foothpath, parks, lawns, drive ways or light traffic arking etc. of required strenght, thickness & size / shape, made by table vibrating method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding / laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra cement complete all as specified and directed. |
| 120 | M&L PCC 1:2:4 type B-1 (using 20 mm graded stone agg) as in seismic and other similar bands, coping, bed block or similar work including necessary form work complete all as specified. |
| 121 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. |
| 122 | Supply and fixing in repair cat eye solar reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions. → |
| 123 | Supply and fixing in repair solar cat eye aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/ 0.3 watt one NI-ed rechargeable battery (1.2V/ 1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc. all as specified and directed |
| 124 | S&F 600 mm bore Reinforced concrete pipes class NP3, laid and jointed complete with collars complete all as specified and directed. |
| 125 | M&L PCC 1:3:6 type C2, 40mm graded agg as in concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 600 mm bore complete all as specified and directed. |
| 126 | S&F 450 mm bore Reinforced concrete pipes class NP3, laid and jointed complete with collars complete all as specified and directed. |
| 127 | M&L PCC 1:3:6 type C2, 40mm graded agg as in concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 450 mm bore complete all as specified and directed. |
| 128 | Returning filling in including spreading levlling ,watering and well ramming in layers nexc 25cm thick complete all as specified and directed. Total carried over to BOQ Rs. 10238513.57 Signature of Contactor DY Dir (Contracts) Date: FOR ACCEPTING OFFICER Schedule 'A' Part V (Sewage Disposal) Item Description of Item Unit Qty Rate per unit (Rs.) Amount (Rs.) |
| 129 | Excavating in trenches in any type of soil , n exc 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soil complete all as specified and as directed. |
| 130 | Excavating in trenches in any type of soil , n exc 1.5 m wide and exc. 1.5 m in deep and n.exc 3.0m deep for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out soil complete all as specified and as directed |
| 131 | Returning, filling in, including spreading ,leveling, watering and well ramming in layers n. exc 25 cm with soil complete all as specified and as directed. |
| 132 | Removal of excavated material (soil) to a distance exc 50 m n. exc 250 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed. |
| 133 | M&L for concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 complete |
| 134 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. |
| 135 | M&L for Brick work with sub class B bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:4).complete all as specified and as directed. |
| 136 | M&L, 15mm thick rendering on any faces of stone, concrete or brick work in CM 1:4 surface finished even and fair complete all as specified and as directed. . |
| 137 | M&L for 15 mm thick rendering in cement mortar (1:3) on brick / concrete/ stone surfaces mixed with water proofing compound as per manufacturer instruction , finished even and smooth using extra cement complete all as specified and as directed. |
| 138 | Supply only water proofing compound. |
| 139 | M&L for cement concrete type C2 1:3:6 (40mm graded stone aggregate) in foundations, filling and mass concrete complete |
| 140 | M&L for cement concrete 1:2:4 type B1 (20 mm graded stone aggregate) as in coping complete |
| 141 | M&L Precast cement concrete Type B-1 1:2:4 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:6 complete all as specified and as directed. |
| 142 | S&F TMT steel bars 6 to 8mm in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) all as specified and directed |
| 143 | S&F TMT steel bars 5mm dia and over, up to and including 10mm dia in stirrups spcers and binders. |
| 144 | M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 145 | M&L for cement concrete type B2 , 1:2:4 using 40 mm gradded stone aggregate in surface channels and drains complete Total carried over to BOQ Rs. 2535589.73 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part VI (Area Drainage) Item Description of Item Unit Qty Rate per unit (Rs.) Amount (Rs.) |
| 146 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 147 | M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate complete all as specified and directed. |
| 148 | M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:6) all as specified |
| 149 | M & L 10mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement complete all as specified and directed. |
| 150 | M&L RCC M - 25 (Design Mix) (20mm graded agg) as in footing etc complete. |
| 151 | M&L RCC M - 25 (Design Mix) (20mm graded agg) as in walls, retaining walls, basement walls, and the like , of any thickness including attached pilaster and butresses, footing etc complete. |
| 152 | Use & wate formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batte |
| 153 | Use & waste formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter |
| 154 | M&L Precast cement concrete Type B-1 1:2:4 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:6 complete all as specified and as directed. |
| 155 | M & L for Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9 mm dia or securing with clips complete. |
| 156 | Returning filling in including spreading levlling ,atering and well ramming in layers nexc 25cm thick complete all as specified and directed. |
| 157 | Removing excavated soil exc. 50m but not exceeding 250 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. Total carried over to BOQ Rs. 2109644.0 Signature of Contactor DY Dir (Contracts) Date: FOR ACCEPTING OFFICER Schedule 'A' Part VII (Site Clearance) Item Description of Item Unit Qty Rate per unit(Rs.) Amount (Rs.) |
| 158 | Suraface excavation n.exc 30 cm deep and averaging 15 cm and getting out in soft soil. |
| 159 | Excavating over areas, n exc 1.5 m deep and getting out soft/loose soil |
| 160 | Earth filling (for site development) incl raising (or lowering) not exc 1.5 m high earth spreading in layers n.exc 30 cm thick watering and rolling and finishing to reqd size and shape etc |
| 161 | Removing excavated material to a distance exc 500m but n exc 1.5km, depositing where directed at a level n exc 1.5 M above the starting point. |
| 162 | M & L for Grubbing up tree trunk (exc 30 cm but n exc 100 cm) including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site |
| 163 | M & L for Grubbing up tree trunk (exc 100 cm but n exc 150 cm) including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site Total carried over to BOQ Rs. 2059051.8 SIGNATURE OF CONTRACTOR DY Dir (Contracts) DATED _________ FOR ACCEPTING OFFICER Schedule 'A' Part VIII (Summer & Cooling Appliances) Item Description of Item Unit Qty Rate per unit (Rs.) Amount (Rs.) |
| 164 | Supply, Install, Testing and commissioning of 'Solar Hot Water System' (Flat Plater Collector) based on indirect transfer of heat of capacity 400 LPD including powert supply backup with 4 kQ heater following accessories all as specified and directed:(i) Solar flat plate collectors shall be constructed strictly as per norms of Ministry of Non conventional Energy Sources (MNES), Govt of India and BIS specification.(ii) Collectors support Structure:- The support structure for the collectors shall be of MS angle of size not less than 50 x 50 x 6 mm. The strcuture shall be provided with suitable flat iron sections to fix collectors on structure and prevent from uprooting during heavy winds. (iii) Hot Water Storage Tank along with structure and insulation: Tank shall be of the full capacity as per the system. Tank shall have thermal stratification to prevent mixing of cold and hot water. The tank shall be made of 20 Gauge (.91 mm) thick stainless sheet SS-316 L with glass liner. Hot water tank shall be insulated with 100 mm thick Rock Wool of density 48 kg/m3 insulated with using chicken wire mesh and vapour barrier. On the top of the insulation, aluminium cladding with 26 SWG aluminium sheet. (ii) Coldwater Tank of suitable capacity (paid separately) Each 8.0 211788.5 1694308.0 |
| 165 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. |
| 166 | Supply, installation,commissioning hi wall split units capacity 2.0 TR indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum inverter type 5 star rating 5.2 of capacity complete all as specified. |
| 167 | Supply, installation,commissioning Deep freezer hard top 400 litres capacity having double door all as specified and directed. |
| 168 | Supply, installation,commissioning of Water cooler fully stainless steel, electric driven and single phase having approx storage 120 litres and nominal cooling capacity 60 Litres per hour all as specified and directed. |
| 169 | Supply, installation,commissioning of Water cooler fully stainless steel, electric driven and single phase having approx storage 80 litres and nominal cooling capacity 40 Litres per hour all as specified and directed. |
| 170 | Supply only bottled water dispenser, having option of dispensing hot and cold water with cooling capacity 3 ltrs/hr and tank capacity of 3.4 ltrs, heating capacity 6 ltrs/hr and tank capacity 1.6 ltrs, working in R - 134a refrigerant including PVC bottle of capacity 20 ltrs for water storage all as specified and directed. Total carried over to BOQ Rs. 5498847.16 Signature of Contactor DY Dir (Contracts) Date: FOR ACCEPTING OFFICER Schedule 'A' Part IX (Lightenning Protection System) Item Description of Item Unit Qty Rate per unit (Rs.) Amount (Rs.) |
| 171 | Supply & fix aluminium strips 25x3 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as directed by Engr - in - Charge . |
| 172 | S&F test point terminal block made out of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw , drolled , cutting upper & lower portion for incoming & outgoing including double insulators two coat of synthic enamel paint complete as directed . |
| 173 | Supply and fix air termination rod single pointed aluminium rod length 12 mm dia & 300 mm long . |
| 174 | M&L for 100 mm thick PCC 1:2:4 TYPE B1 using 20mm graded stone aggregate as in floor. |
| 175 | Supply and errect vertically Galvanised, medium grade pipe 20 mm diameter complete with fittings for raising height for air termination rods all as specified and directed. Total carried over to BOQ Rs. 155118.06 Signature of Contactor DY Dir (Contracts) Date: FOR ACCEPTING OFFICER Schedule 'A' Part X (Fire Fighting System) Item Description of Item Unit Qty Rate per unit (Rs.) Amount (Rs.) |
| 176 | S & F for MS ERW pipe 50 mm dia as per IS 1239 including cutting /threading/welding etc for providing connections and including all types of reqd fittings , clamps, nout & bolts etc for laid on wall/ceiling/ floor/ all as specified and directed. |
| 177 | S & F for MS ERW pipe 25 mm dia as per IS 1239 including cutting /threading/welding etc for providing connections and including all types of reqd fittings , clamps, nout & bolts etc for laid on wall/ceiling/ floor/ all as specified and directed. |
| 178 | S & F Valve,gate/ball, screwed,15 mm, brass with iron wheel head, screwed both ends for iron/MS pipe and complete all as directed. |
| 179 | S & F Valve,gate/stop, screwed,50 mm , brass with iron wheel head, screwed both ends for iron pipe and complete all as directed. |
| 180 | M & L for RRL hose reel of 20 mm dia 30 mtr long including hose box conforming to IS - 5132 complete all as specified and as directed. |
| 181 | S & F for booster(pressure) pumps / Terrace pump for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 30m head, 450 LPM discharge including suitable size automatic pressure maintained pump starter complete all as specified and as directed. Rates are incl of reqd foundation wk, hur type shed for pump set made of GI sheet & angle iron, all electrical and water connection etc complete all as specified and as directed. |
| 182 | M&L for painting over steel/ iron Surfaces of any description, over 10cm in width or girth,not otherwise described incl preparation of surfaces, appying red oxide primer 01 coat, and 02 coat of synthetic enamel paint complete all as specified and as directed. Total carried over to BOQ Rs. 458111.0 Signature of Contactor DY Dir (Contracts) Date: FOR ACCEPTING OFFICER Schedule 'A' Part-XI (Internal Water Supply) Item Description of Item Unit Qty Rate per unit(Rs.) Amount (Rs.) |
| 183 | S&F 15 mm bore galvanized steel tubing, medium grade galvanised with all fittings, fixed to walls and ceilings or laid in floors incl cutting chasing and making good complete all as specified and directed. |
| 184 | S&F 20 mm bore galvanized steel tubing, medium grade galvanised with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed. |
| 185 | S&F 25 mm bore galvanized steel tubing, medium grade galvanised with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed. |
| 186 | S&F 50mm bore galvanized steel tubing, medium grade galvanised with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed. |
| 187 | S&F in 20mm bore gun matel glove or gate valve valve cast copper alloy with handle screwed both ends for GI out let/inlet pipe or for union including threading to existing pipes on both ends complete all as specified and directed by Engineer in Charge. |
| 188 | S&F in 25mm bore gun matel glove or gate valve valve cast copper alloy with handle screwed both ends for GI out let/inlet pipe or for union including threading to existing pipes on both ends complete all as specified and directed by Engineer in Charge. |
| 189 | S&F in 50mm bore gun matel glove or gate valve valve cast copper alloy with handle screwed both ends for GI out let/inlet pipe or for union including threading to existing pipes on both ends complete all as specified and directed by Engineer in Charge. |
| 190 | S&F in 15mm dia pillar taps, cast copper alloy with capstan heads chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe, complete all as specified and directed. |
| 191 | S & F in for long body Bib taps, cast copper alloy with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule and fixed, 15 mm, fancy type, chromium plated fixed complete. |
| 192 | S & Fin for Angle cock/Stop valves, cast copper alloy, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed , 15 mm fixed complete. |
| 193 | S&F in PVC connections 15 mm size with brass nuts both side of length 450 mm complete all as specified and directed . |
| 194 | S & F in Brass chromium plated wall Mixer (2/3 hole) for mixing hot & Cold water arrangement, long shank suitable 15mm bore of pipe of approved quality screwed down for iron pipe and fixed |
| 195 | S&F in chromium plated mixer for wash hand basin for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed by Engr-in-charge. |
| 196 | S&F brass chromium plated overhead shower 125mm size ( square/ rectangular ) with or without swivel joints including fixing to steel pipe of 15mm bore complete all as specified and directed . |
| 197 | S & F in Vitreous China urinals half stall white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) , complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed by Engr-in-charge. |
| 198 | S & F in Urinal spreader of PTMT any color for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed by Engr-in-charge. Total carried over to BOQ Rs. 758081.35 Signature of Contactor DY Dir (Contracts) Date: FOR ACCEPTING OFFICER Schedule 'A' Part-XII (Internal Electric Supply) Item Description of Item Unit Qty Rate per unit(Rs.) Amount (Rs.) |
| 199 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with mudular metal box min 1.2mm thick, duly covered with modular white colour plate with frame and other necessary accessories ncluding PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- (a) One light point controlled by one, one way switch 5 Amps Point 1246.0 992.75 1236966.5 (b) One fan point/ exhaust fan/wall fan point controlled by one, one way switch 5 Amps and regulator Point 528.0 992.75 524172.0 (c) One light point controlled by , two way switch 5 Amps Point 16.0 1397.96 22367.36 (d) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. Point 50.0 284.1 14205.0 (e) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. Point 476.0 1070.4 509510.4 |
| 200 | Description all as per item No 1 here in before but using 2.5 sq mm single core copper conductor two nos cables of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 201 | Description all as per item No. 1 here in before but using 4.0 sq mm single core copper conductor two nos FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 4.0 sq mm PVC insulated copper conductor FRLSH cable as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 202 | S & F ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete. |
| 203 | S & F modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified. |
| 204 | S & F modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified. |
| 205 | S & F modular switch piano flush type, single pole, two way, and 5/6 Amp single module complete all as specified. |
| 206 | S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 207 | S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 208 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSh cable with stranded copper conductor of size 1.5 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 1.5 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Two runs of 1.5 sqmm cable,one run of 1.5 sqmm cable and one run of PVC conduit will be measured as one unit |
| 209 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSh cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Two runs of 4 sqmm cable,one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit |
| 210 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSHH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSHH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit |
| 211 | M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSh cable with stranded copper conductor of size 10 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc two runs of PVC insulated with 10 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Four runs of 10 sqmm cable, one runs of 10 sqmm cable and one run of PVC conduit will be measured as one unit |
| 212 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSh cable with stranded copper conductor of size 10 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 10.0 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Two runs of 10 sqmm cable,one run of 10 sqmm cable and one run of PVC conduit will be measured as one unit |
| 213 | S & F for sheet metal enclosure MCCB DB VTPN 4 way Vertical type with min 200 Amps rated copper bus bar 415 volts for incoming MCCB 4 pole -01 Nos and out going 12 Nos MCB Modules with double door with magnitic locking system including blanking plate and necessary provision for inserting the DBs in wall by cutting the brick/stone masonry etc and making good of disturbed surface to match with existing colour of wall complete all as specified and as directed. (First floor/Second floor/Third floor) |
| 214 | S & F for sheet metal enclosure MCCB DB VTPN 4 way Vertical type with min 200 Amps rated bus bar 415 volts for incomming MCCB 4 pole -01 Nos and out going 12 Nos MCB Modules with double door with magnitic locking system including including blanking plate necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.(Ground floor) |
| 215 | S & F for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door including blanking plate for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 216 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door including blanking plate for dummy space with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonry etc and making good of disturbed surface to match with existing color of wall complete all as specified and as directed. |
| 217 | S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door including blanking plate for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 218 | S & F for MCCB four pole rated capacity 80 Amps,( nearest standard size ) 415 Volts breaking capacity 16 KA, 'C' curve complete all as specified and as directed. |
| 219 | S & F for MCCB four pole rated capacity 63 Amps,( nearest standard size ) 415 Volts breaking capacity 16 KA, 'C' curve complete all as specified and as directed. |
| 220 | S & F for MCB DP rated capacity 32 Amps, (nearest standard size ) 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 221 | S & F for MCB DP rated capacity 25-16 Amps, (nearest standard size ) 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 222 | S & F for MCB DP rated capacity 40 Amps, (nearest standard size ) 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 223 | S & F for MCB DP rated capacity 63 Amps, (nearest standard size ) 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 224 | S & F for MCB Single pole rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 225 | S & F for MCB Single pole rated capacity 6-32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 226 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator modular type and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.0 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. |
| 227 | S & F for energy efficient exhaust fan of 380 mm sweep made of metal body complete with louver with bolts nuts and washers, bolt , embedded in the wall including provision of PVC flexible copper cable three core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. |
| 228 | S & F for energy efficient exhaust fan of 450 mm sweep made of metal body complete with louver with bolts nuts and washers, bolt , embedded in the wall including provision of PVC flexible copper cable three core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. |
| 229 | S & F surface/recess mounted ceiling light of capacity 36 watt, approx size of 2x2 ft , 230 volts with CRCA housing luminous efficacy not less than 120 lumen/W with and intregrated electronic driver connector block etc LED Chip, Driver and housing should be of same make complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor with flexible conduit of suitable size complete all as specified and as directed. |
| 230 | S & F surface mounted mirror light of capacity 5 watt, , 230 volts with CRCA housing with and intregrated electronic driver with luminous efficacy not less than 120 lumen/watt connector block etc LED Chip, Driver and housing should be of same make complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor with flexible conduit of suitable size complete all as specified and as directed. |
| 231 | S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminum housing, high transmissibility diffuser, high lumen ouput box type fitting, luminous efficacy not less than 120 lumen/watt 230 volts and integrated electronic driver connector block etc LED Chip, Driver and housing should be of same make complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multi stranded copper conductor and flexible conduit of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. |
| 232 | S & F for Energy saving new generation environmental friendly long life versatile pressure die cast aluminum IP 66 for security light fitting luminaries with high power LEDs as light source and electronic driver of capacity 35 watts , luminous efficacy not less than 110 lumen/watt LED Chip, Driver and housing should be of same make with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. |
| 233 | S & F for PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories with junction and other accessories heavy duty ISI marked of size 20 mm dia for LAN, telephone and TV connections including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed. |
| 234 | M & L for earthing complete with galvanized earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvenised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 3 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC(1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC(1:2:4) type B-1 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe and 15 mm dia GI pipe for protection of GI wire up to 7.5 mtr connected to earthing point complete all as specified and as directed. Total carried over to BOQ Rs. 8092545.16 Signature of Contactor DY Dir (Contracts) Date: FOR ACCEPTING OFFICER |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail