| 1 | Two Nos. Security Room |
| 2 | Earth work in excavation of foundation trenches or drains in all sorts of soil ( including mixed soil but excluding laterite or sand stone ), including removing, spreading or stacking the spoils with in a lead of 75 m. as directed and including trimming the side of trenches, leveling, dressing the bottom, bailing out water etc. as required complete.(a) Depth of excavation not exceeding 1500 mm |
| 3 | (c) Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates ( 1% concentration ) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS-6313 ( part - II ) 1981. ( Mode of measurment will be per Sq.m. of plan area of plinth treated.) |
| 4 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) |
| 5 | (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 6 | Cement concrete with graded stone ballast (40 mm.size) excluding shuttering. A) [Pakur Variety] (1:3:6) |
| 7 | Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. |
| 8 | Controlled Cement concrete withwell gradedstonechips (20mm graded nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS:456 and relevant special publications,submission of job mix formula after preliminary mix design after testing of concrete cubes as perdirection of Engineer-incharge.Consumption of cement will not be less than 300Kg of cement with Superplasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade.Pakur Variety |
| 9 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction ofEngineer-In-Charge. i) Ground Floor. |
| 10 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m iii) (OTHER MANUFACTURERS NOT SPECIFIED ) |
| 11 | Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth |
| 12 | Brick work with 1st class bricks in cement mortar (1:6) . b) In superstructure, ground floor. upto 4.00 m (Long Side) |
| 13 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) |
| 14 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor) (i) With 1:4 cement mortar . (a) 20mm thick plaster , In gr floor |
| 15 | (b) 15 mm. thick plaster , In gr floor |
| 16 | (c) 10 mm. thick plaster , In gr floor |
| 17 | Supplying and laying Polythene Sheet (150gm/sq.m) over damp proof course or below flooring or roof terracing or in foundation trenches. |
| 18 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement(iii) 35 mm. thick |
| 19 | Supplying fitting fixing fan hook for ceiling with 1 metre long 16 mm dia rod complete including mending damages. |
| 20 | Applying Exterior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacture's specification and as per direction of the Engg-in-Charge. (b) Two Coats |
| 21 | Protective and decorative acrylic exterior emulsion paint of approved quality as per manufacturers specification and as per EIC to be applied over acrylic primer as required. The rate includes cost of materials, labour, scaffolding and all incidental charges but excluding the cost of primer. In ground floor( two coats) b) Premium 100% Acrylic Emulsion |
| 22 | Applying Interior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. ii) Solvent based interior grade Acrylic Primer (b) Two Coats |
| 23 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific nstruction of Superintending Engineer) :(Two coats) ii) Luxury Quality |
| 24 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc. |
| 25 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (iv) Two coats |
| 26 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming toIS:13592-1992 with all necessary clamps nails, including making holes inwalls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining withjointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: (iii) 160 mm. Dia. |
| 27 | a) Plain Tee A) UPVC Pipes: Fittings (iii) 160 mm. Dia. |
| 28 | d) Shoe A) UPVC Pipes: Fittings (iii) 160 mm. Dia. |
| 29 | Neat cement punning about 1.5 mm. thk. In all dado, window, sills, floor, drain etc. |
| 30 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately).(a) 40mm X 6mm, 250mm Length |
| 31 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.(i) 50mm. X 37mm. X 1.50mm. |
| 32 | Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.(a) 200mm long. |
| 33 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (a) 35 mm thick shutters (single leaf) |
| 34 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).(d) Sal : Local. |
| 35 | Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & sideframe), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white. For 3-Track window : Members for Bottom frame @ 1.233 Kg per Mtr. and for Top and Side frame @ 1.067 Kg per Mtr. and for shutter Bottomand Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. |
| 36 | Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6m height for external wall) (i) 3 mm thick (weighing 7.4 kg/Sq.m) |
| 37 | (b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. Door |
| 38 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface : (iv) Two coats (with any shade except white |
| 39 | Tubewell |
| 40 | Labour for boring through any type of soil for sinking Tube - Well of required dia with top enlargement by rig boaring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants stagging, force pumping set and making arrangements for water required for boring etc. complete and lowring of pipes, strainer, blind pipes etc. complete. For depth up to 250 M. for 100 mm. dia tube well with top enlargement of 200 mm. dia. (up to 50 M.) for first 50 Mtr. |
| 41 | for next 50 Mtr. |
| 42 | for next 50 Mtr. |
| 43 | for rest 50 Mtr. |
| 44 | Supplying, fitting and fixing PVC pipes for underground work of approved make (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metrebelow surfacein all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) a) 150 mm internal dia |
| 45 | b) 100 mm. internal dia |
| 46 | Supply of High Density Poly-ethylene Pipe conforming to IS-4984-1985(dia) 6Kg./Sq.Cm.(working pressure) 75mm. Dia |
| 47 | Supplying, fibre glass reinforced Epoxy resin slotted of 1 mm slot width in 6.1m length of approved make and as per direction of the Engineer - in - Charge (100 mm dia) b) 100 mm. nominal dia. i) 6mm wall thickness |
| 48 | Supplying, Fitting & Fixing Steel cutter Piece upto 450mm long with sockets. (iii) 75 mm dia |
| 49 | Supplying, fitting and fixing heavy type bell mouth reducing socket. (iv) 100 mm X 150 mm |
| 50 | Washing and developing Tube - Well with air compressor pump and engine for 8 ( eight) hours continious pumping per ay with necessary arrangement for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required complete in all respect. for Tube - Well of 100 mm. dia. With top enlargement 200mm. Dia. To have yield of 6000 gallons per hour. For 3 (Three day's) |
| 51 | Packing the annular space between the out side of the Tube Well pipe and strainers and the bore ith pea size washed gravel of approved quality having size from 2 mm. to 5 mm. or the size approved by the Engineer - in charge including cost of all materials labour and equipment complete. |
| 52 | Supplying, fitting and fixing G.I. cap at top. (iii) 200 mm |
| 53 | Providing 200 mm centre guide. i) With Clamp |
| 54 | Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction. |
| 55 | Geophysical Investigation of the aquifer by electro logging system with tools & plants as necessary including supply of necessary report |
| 56 | Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete. |
| 57 | Electrical |
| 58 | Supply of one No. 2 core 10 sqmm XLPE/PVC Alluminium armoured cable . |
| 59 | Laying of one No. cable of 2 core 10 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. |
| 60 | Laying the 2 core 10 sqmm cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. |
| 61 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below For 2 core 10 sqmm |
| 62 | Finishing the end of following 2 core 10 sqmm cable XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials |
| 63 | Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core |
| 64 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium)Protection with necessary fittings and jointing materials as required. (b) 32 mm dia |
| 65 | Supplying and fixing of 240V 16Amp DP with fuse on L&N Sheet steel Main Switches on flat iron frame on wall (Make: Havells or equivalent) |
| 66 | Supplying and Drawing of 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC. 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe 19 mm dia 3 mm thick polythene pipe without earth continuity wire dia , by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works.[From main switch to SPN DB ]. |
| 67 | Supplying and fixing (2+6) way double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.With Supplying and fixing 240/415 V 40A DP MCB Isolator on din rail of existing DBs and necessary connection and necessary connection and Supplying and fixing6 nos 240 V (6-32) A SPMCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.(Make- Havells or equivalnt reputed brand). |
| 68 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish: 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC.Average run 8 mtr |
| 69 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish: 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC on Board |
| 70 | Supply of 20 watt ECO Compact industrial batten suitable for single T8 LED tube.Model No.DIJB12LT8-20.Make- Crompton or equivalent reputed brand including.Supply of 20 watt ULTRONLED polycarbonate T8 tube with in built driver and metal heat sink. Efficacy of 100 Lumens/W.Model No.LT8-20-865-(2).Make- Crompton or equivalent reputed brand. |
| 71 | Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. |
| 72 | Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. |
| 73 | Supply of 10 watt LED ADORE 2 star Lamp. Model No-LHLDEUEEML8R010Make- Havells or equivalent reputed brand. |
| 74 | Supply of 240V 1200 mm Sweep A.C Ceiling fan (colour- Brown, Model-ARCTIC AIR) with all accessorioes and down rod wire with necessary connection as per G.S (Make: Orient or equivalent reputed brand) |
| 75 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire |
| 76 | Supplying&Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40mmx9mm MS flat including making good damages to building roof with satisfactory finishing and painting– (As per Drawing no. 475 of PWD Specification Book – May 1991) |
| 77 | Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. |
| 78 | Supplying and Drawing of 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe 19 mm dia 3 mm thick polythene pipe without earth continuity wire dia , by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works.[From main switch to SPN DB ]. |
| 79 | Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 80 | Distribution wiring in 1.1 KV single core stranded 'FR'PVC insulated & unsheathed copper wire (Brandapproved by EIC) in 20mm size PVC rigid conduit 'FR'(Precision make) incl. necy. fittings as required.2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 81 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as require. (i) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 82 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 16 A SPMCB one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint |
| 83 | Supply of 45 Watt FREEDOM NEO LED streetlight made up of pressure die cast housing with toughened glass and high power LEDs with secondary optics with IP65 protection.Model no-LSTS-45-CDL-M (Make : Crompton /Equivalent ) |
| 84 | Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. |
| 85 | Excavation of soil for installation of Earth Electrode and filling & ramming forsoft Soil. |
| 86 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below By TATA-Medium GI pipe |
| 87 | Extra treatment of soil by using salt and charcoal for pipe electrode |
| 88 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. |
| 89 | S&F earth busbar of Galv .M.S plat 50mm *6mm on wall having clearance of 6mm from wall incl. providing drilled holes on the busbar complete with G.I bolts , nuts ,washers spacing insulator etc. as required |
| 90 | Connecting the equipments to early busbar incl. S&F No. 8 SWG G.I. wire on wall /floor with stapels as per G.S. |
| 91 | 5 KWp On grid Solar System |
| 92 | Supply, Installation & Commissioning 4.95 Kw Roof Top On Grid Solar System with poly crystaline modules, 330 wp Solar PV modules - 15 Nos (Make-Tata Power Solar), AJB, 2 I/P 2 O/P, with Fuse, SPD Type-II -1 No.(Make-Trinity/Hensel/Eligent/TPS), Grid Connected Solar Inverter (1X5 Kw, 415 V AC 50 Hz MPPT) DC:AC=1:3 max -1 no.(Make-Growatt/Goodwe/Powerone), Dongle GPRS (wifi enable)- 1 set(Make-ITAPS), ACDB with SPD 3 ph -1 set (Make-Eligant/TPS) , Earthing Kit 1.5M,14.2 mm dia, copper B -3 Set,Lightening Arrestor Height 2 Mtrs Conve -1set, Installation Kit (Comm Cable etc)- 1 set including Net metering documentation charges. |
| 93 | Supplying & fixing ABC Stored Pressure type Fire Extinguisher og 6 kg capacity consisting of welded cylinder squeeze lever discharge valve fitted with pressureindicating guage with internal discharge tube,discharge hose and nozzle,suspension bracket,conforming to IS:15683 duly charged with ISI Market Mono Ammonium Phosphate Base ABC Powder conforming to IS:14609 And pressurized with nitrogen gas. Temparature Range(-)30ºC to (+)55ºC.Fire Rating-2A & 21B. Make- Fireshield or equivalent reputed brand. |
| 94 | Supplying & fixing CO2 type Fire Extinguisher og 4.5 kg capacity conforming to IS:15683:2006 made from seamless cylinder conforming to IS:7285 duly approved by chief controller of Explosive,Nagpur,fitted with ISI Marked Controlled valve conforming to IS:3224,high pressure 1 mtr. long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket suitable for operating between (-)30ºC to (+)55ºC,Fire Rating Class-13B. Make- Fireshield or equivalent reputed brand. |
| 95 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required (iii) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) [For pump] |
| 96 | Supply, Installation, Testing & commissioning of 2 H.P. submersible motor pump set including flat cable for office building purpose having capacity of 20 L / min - 100 L / min dischage (Lump Sum). Model no-CORA 1C/50G+UMAI100-1.5/22 1.5 SQMM.Make- KSB or equivalent reputed brand. |
| 97 | Supplying of max. motor Output for 2 HP, 1.5 KW DOL Starter. |
| 98 | Fixing only starter (for motor control ) on angle iron frame on wall ,Direct on line Satrter for motor up to 5 HP |
| 99 | Conventional Lightening Protection System |
| 100 | S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1) |
| 101 | Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
| 102 | Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation of overhead reservoir (vertical run) |
| 103 | Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. |
| 104 | Excavation of soil for installation of Earth Electrode and filling & ramming for Soft Soil. |
| 105 | Earthing with 50mm dia G.I. pipe (TATA-M) 3.64mm thick * 3.04 Mtrs. Long and 1*4 WG wire (4 Mtr. Long) 13mm dia * 80mm long G.I. bolts double washers incl. S&F dia pipe protection (1Mtr long) to be filled with bitumen partly under the G.L. and partly above G.L. driven to an average depth of 3.65Mtrs .below the G.L. and restoring the surface duly remmed. |
| 106 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. |
| 107 | Extra for treatment of soil by using salt & charcoal or coke for plate electrode. |
| 108 | S&F earth busbar of Galv .M.S plat 50mm *6mm on wall having clearance of 6mm from wall incl. providing drilled holes on the busbar complete with G.I bolts , nuts ,washers spacing insulator etc. as required |
| 109 | Connecting the equipments to early busbar incl. S&F No. 8 SWG G.I. wire on wall /floor with stapels as per G.S. |
| 110 | Add S.G.S.T. 9% |
| 111 | Add C.G.S.T. 9% |
| 112 | Add L.W.C. Cess Please Enable Macros to View BoQ information |