| 1 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 2 | 3 x 1.5 sq. mm |
| 3 | 3 x 2.5 sq. mm |
| 4 | 3 x 4 sq. mm |
| 5 | 3 x 10 sq.mm. |
| 6 | 6 x 16 sq.mm. |
| 7 | Supply and fixing of 32 x 20 mm DLP mini- trunking white-system with independent cover etc. as required complete. |
| 8 | Supply and fixing of following accessories suitable for 32 mm x 20 mm size plastic trunking white system. |
| 9 | End cap |
| 10 | Internal / external angle |
| 11 | Changeable flat angle |
| 12 | Flat junction |
| 13 | Supply and fixing of 105 x 50 mm DLP trunking white-system but without cover and partition etc. as required complete. |
| 14 | Supply and fixing of following accessories suitable for 105 mm x 50 mm size plastic trunking white system. |
| 15 | 85 mm flexible cover |
| 16 | End cap |
| 17 | Internal angles- adjustable from 80°-100° |
| 18 | External angles- adjustable from 60°-120° |
| 19 | Flat junction |
| 20 | Flat angles |
| 21 | Separation partitions |
| 22 | Joints for 85mm width cover |
| 23 | Base joints |
| 24 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 25 | 25 mm |
| 26 | 32 mm |
| 27 | S & F following size of steel flexible pipe along with the accessories on surface etc as required |
| 28 | 25 mm |
| 29 | 32 mm |
| 30 | Supply and fixing of following LED light fixture with efficiency >100 lumen/ watt, P.F. >0.95, THD<10%, Electronic driver, LED lamp, reflector, diffuser, MS body/housing holder etc. complete with all fixing accessories and lamp as required complete. |
| 31 | 18 watt recess 300 x 300 mm mounting LED light fixture |
| 32 | 18 watt surface mounting 300 x 300 mm LED light fixture |
| 33 | 36 watt recess mounting LED light fixture 600 x 600 mm |
| 34 | 36 watt recess mounting LED light fixture 300 x 1200 mm |
| 35 | 36 watt surface mounting LED light fixture 300 x 1200 mm |
| 36 | Supplying, installation of Clip-on frame with finishing plate for 85mm cover for DLP plastic trunking 105mm x 50mm etc. as reqd. |
| 37 | 3 module |
| 38 | 6 module |
| 39 | Supplying and fixing following modular switch/ socket on the existing clip-on frame fixed on 85mm cover of 105 x 50 mm DLP plastic trunking including connections etc. as required complete. |
| 40 | 6 A switch |
| 41 | 20 A switch |
| 42 | 6 A pin 2/3 pin socket outlet |
| 43 | 6 A pin 2/3 pin socket outlet |
| 44 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 45 | 5/6 A switch |
| 46 | 15/16 A switch |
| 47 | 3 pin 5/6 A socket outlet |
| 48 | 6 pin 15/16 A socket outlet |
| 49 | Blanking Plate |
| 50 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 51 | 3 Module |
| 52 | 6 Module |
| 53 | Supplying and fixing following size/ modules, plastic box for modular switches in recess etc as required. |
| 54 | 3 Module |
| 55 | 6 Module |
| 56 | Dismantling, disconnecting old damaged unserviceable fl fitting/ exhaust fan/ ceiling fan/ bulkhead fitting with bracket etc. as reqd. and depositing in sectional store. |
| 57 | Dismantling concealed & damaged DB/TPN Switches/starter/ loose wire boxes along with all accessories and depositing the same in the sectional store repairing the damages as reqd complete. |
| 58 | Dismantling the old conduit pipe/wood batten of all sizes from surface/recessed & making good the damages I/c filling the holes of the surface etc as reqd. and depositing it in sectional store. |
| 59 | Fixing 20/25/32 mm conduit pipe/ DLP on surface with clamp/in recessed only conduit pipe supplied by department.(Free of cost) |
| 60 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) |
| 61 | 12 way, Double door |
| 62 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 63 | 8 way (4 + 24), Double door |
| 64 | Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 65 | Single pole 5 A to 32 A |
| 66 | Single Pole (40A-63A) |
| 67 | Double Pole (40A-63A) |
| 68 | Four Pole (40A-63A) |
| 69 | S&F, Copper tube / reducer/ lug terminals suitable for following size of conductor. |
| 70 | 6 /10/16 Sq.mm. |
| 71 | Laying of 1/2/3 run of UTP cable enhanced cat 5/cat 6 cable in existing steel conduit pipe/GI pipe/ raceway / RCC pipe as reqd. the cost shall also include numbering of networking wire from room to rack as reqd. (wire will be supplied by dept) |
| 72 | Fixing of RJ-45 modular box with cover plate or I/o box for internet on surface/ recessed cutting the wall making good the same as required. ( box and cover plate will be supplied by dept.) |
| 73 | Fixing of Network rack on steel fastener including cartage from store to site as reqd complete. |
| 74 | Supplying & fixing 3mm (1/8\\") thick phenolic laminated sheet on existing board with screw & washer etc. as required. |
| 75 | Overhauling of ceiling fan of any size including dismantling and refixing of fan, bearings, checking, cleaning the all parts and supply & replacement of rubber real, rubber rings, nut bolts, hanger clamps, bearing plates, cotter/ split pin, varnishing if reqd etc, reassembling testing and commissioning of fan as required complete. Please Enable Macros to View BoQ information |