| 1 | Rewiring of Powerhouse building, Inspection Quarter |
| 2 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 3 | 2 x 1.5 sq.mm |
| 4 | 3 x 1.5 sq.mm |
| 5 | 3 x 2.5 sq. mm |
| 6 | 3 x 4 sq. mm |
| 7 | 3 x 6 sq. mm |
| 8 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. conduit as required. |
| 9 | 20 mm |
| 10 | 25 mm |
| 11 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 12 | 1 or 2 Module (75mm x 75mm) |
| 13 | 3 Module (100mm x 75mm) |
| 14 | 4 Module (125mm x 75mm) |
| 15 | 6 Module (200mm x 75mm) |
| 16 | 8 Module (125mm x 125mm) |
| 17 | 12 Module (200mm x 150mm) |
| 18 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 19 | 5/6 A switch |
| 20 | 2 way 5/6 A switch |
| 21 | 15/16 A switch |
| 22 | 3 pin 5/6 A socket outlet |
| 23 | 6 pin 15/16 A socket outlet |
| 24 | Supplying and fixing modular blanking plate on the existing modular plate & Switch box excluding modular plate as required |
| 25 | Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box / wooden block including connections etc. as required |
| 26 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 27 | Supplying and fixing PVC batten / Angle Holder including connections etc. as required |
| 28 | Installation, testing, Commissioning of wall bracket/ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete all connections including connections etc, as required. |
| 29 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 30 | Installation, testing and commissioning of pre-wired, fluorescent fitting Compact fluorescent fitting of all types, Complete with all accessories and tube/lamp etc. directly o ceiling wall, including Connections with 1.5 sq. mm FRLS PVC insulated. Copper Conductor, single core cable and earthing etc. as required |
| 31 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 32 | Supplying and fixing following way single pole and neutral (SPN) sheet Steel MCB distribution board 240 volt, on surface / recess complete with tined copper, bus bar, neutral bus bar, Earth Bar, Din bar, intercontinctions, powder painted including earthing extra as required (but without MCB RCCB isolator) |
| 33 | 12 Way Double Door |
| 34 | Supplying and fixing following way horizontal type three pole and neutral (TPN) sheet Steel MCB distribution board 415 volt, on surface / recess complete with tined copper, bus bar, neutral bus bar, Earth Bar, Din bar, intercontinctions, powder painted including earthing extra as required (but without MCB RCCB isolator) |
| 35 | 6w (4+18) Double Door |
| 36 | Supplying and Fixing 5A to 32A rating, 240V/415V, 10KA \\" C\\" curve miniarture Circuit Breaker Suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required. |
| 37 | Single Pole |
| 38 | Supplying and fixing of Single pole blanking plate in the existing MCB DB Complete etc as Required. |
| 39 | Supplying and fixing following rating double pole 240V, isolator in the existing MCB DB Complete with connections, testing and Commissioning etc as Required. |
| 40 | Supplying and fixing following rating four pole 415V, isolator in the existing MCB DB Complete with connections, testing and Commissioning etc as Required. |
| 41 | Supplying and fixing following rating, double pole( single Phase and neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 42 | Supplying and fixing following rating, four pole( three Phase and neutral), 415V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 43 | Earthing with GI earth pipe 4.5Mtr long, 40mm dia including accessories and providing masonry Enclosure with cover plate having locking arrangement and watering pipe etc with Charcoal / coke and salt as required |
| 44 | Laying of one number PVC insulated and PVC Sheathed / XLPE power power cable of 1.1KV grade of following size direct in gound including excavation, sand cushioning, protective covering and refilling the trench etc as required |
| 45 | Upto 35 sq.mm |
| 46 | supplying and fixing cable route marker with 10cm x 10cm x mm thick CI plate with inscription there on bolted / welded to 35mm x 35mm x 6mm angle iron, 60cm Long and fixing the same in the ground as required. |
| 47 | Providing , laying and fixing following dia GI pipe(Medium class) in ground complete with GI fittings including trenching (75cm deep) and refilling etc as required. (For Road Crossing) |
| 48 | 100mm dia |
| 49 | Supply of 24W LED Batten of 4 feet cool white (6500K) operating in 230V / 50Hz of reputed make |
| 50 | Supply of 12W LED Bulb of cool white (6500K) of B22 type operating in 230V / 50Hz of reputed make |
| 51 | Supply of 10W LED/ IP 65 aluminum die cast surface mounting type Bulk head fitting operating in 230V / 50Hz Supply of reputed make |
| 52 | Supply of 12W Mirror fitting suitable for Wash basin mirror operating in 230V / 50Hz of reputed make |
| 53 | Supply of 5 Watts Foot Light of 4 module operate in 230V/ 50Hz of reputed make |
| 54 | Supply of 1200mm ceiling fan, double ball bearing, aluminum blades, class B Insulation, with 300mm down rod, nut, bolt, clamp set operating in 230V / 50Hz Supply but without regulator of reputed make |
| 55 | Supply and Installation of 1 ton, 5 star rating inverter fixed speed, fully copper split air conditioner working at 230 V, 1 Phase, 50 Hz, AC comprising of indoor and outdoor unit with remote, Swing, Timer, with installation (inclusive of 3m copper pipe, 3M cable except out door wall stand.) of reputed make |
| 56 | Supply and Installation of 5KVA fully copper, Automatic wall mounting type voltage stabilizer Single Phase Sine wave (160V-260V) input and Single phase sine wave (210V - 250V) output suitable for 1 ton split Air conditioner of reputed make |
| 57 | Supply and installation of 5 star rating 6Ltr capacity water Geyser of reputed make |
| 58 | Supply of 40 KVA, 3 Phase, 4Wire indoor type, copper coiled, air cooled stabilizer, input voltage Range: 120 - 280 Volt, Output Voltage: 415V, Controls: All the three phases controlled individually for better voltage and load management with By Pass arrangement of reputed make |
| 59 | Supply of 4core x 25 Sq.mm copper conductor of 1.1KV armoured PVC insulated / PVC sheathed XLPE UG cable as required. (Laying from EB mains to 40KVA Stabilizer and 40KVA Stabilizer to Distribution Panel at Power House) of reputed make |
| 60 | Supply of 4core x 10 Sq.mm copper conductor of 1.1KV armoured PVC insulated / PVC sheathed XLPE UG cable as required of reputed make |
| 61 | Supply of 4core x 6 Sq.mm copper conductor of 1.1KV armoured PVC insulated / PVC sheathed XLPE UG cable as required. (Laying from Power House to Temporary Shed) for temporary connection of reputed make |
| 62 | Supply of 2core x 4 Sq.mm copper conductor of 1.1KV armoured PVC insulated / PVC sheathed XLPE UG cable as required. (Laying from Power House to Temporary Shed) for temporary connection of reputed make |
| 63 | Supply of 2core x 2.5 Sq.mm copper conductor of 1.1KV armoured PVC insulated / PVC sheathed XLPE UG cable as required. (Laying from Power House to Temporary Shed) for temporary connection and Street Light, Garden Light, Gate Light, Gazifo Light of reputed make |
| 64 | Supply, Installation, Testing and commissioning of 250A floor mounted type distribution panel, made up of 16 gauge CRCA sheet fully powder coated Siemens Colour for 3 phase 4 wire system comprising of Surge protective device 3P+N / imax 100KA with 63A, 4Ploe MCB, 25mm X 6mm Copper Bus Bar for phase and neutral and 25X3mm Copper for Earth of the panel board. Incoming : 250A/4 pole MCCB for EB Mains incomer, 250Amps, 4Pole Change Over Switch -2Nos, Metering : R,Y,B Indicators : 1 Set , Multi function meter VAF Meter : 1 No with suitable CT, Outgoing : 63A TPN Fuse Switch - 3Nos and Analog KWH (Energy) Meter chamber -1No for Static Sensor, 63Amps 4 Pole MCB: 3 Nos, 32Amps, 2 Pole MCB : 9 Nos, 16Amps 1 Pole MCB -9Nos with suitable connector for outgoing. (Including termination of all Cables Incoming/Outgoing)) as per drawing. |
| 65 | Supply of Battery Charger 0-40V, 40A, dimmer stat controlled comprising of Voltmeter, Ammeter, protection fuses for input and output of reputed make |
| 66 | Supply of Battery Charger 0-120V, 40A, dimmer stat controlled comprising of Voltmeter, Ammeter, protection fuses for input and output of reputed make |
| 67 | Supply and laying of 10SWG bare copper wire in recess or surface from earth pit to Distribution panel in Power house and Earth bit to IQ DB |
| 68 | Supplying and Fixing 20A/25A rating, 240V/415V, C\\" curve single module modular miniature Circuit Breaker Suitable for inductive load modular plate & switch box including connections etc. as required of reputed make |
| 69 | Charges for laying additional length of copper tube from indoor unit to outdoor unit with 3 core x 2.5 sq.mm copper cable with laying of 13mm thick Nitrile Rubber Tubular pipe insulation for refrigerant piping including supports, clamps, necessary civil works like wall opening and closing for Refrigerant pipes as per site condition, etc. (beyond 3 Mtre length) |
| 70 | Supply & laying of High Density 25mm PVC drain pipe (Including, bend coupling etc according to site condition) 1 Length -10 Feet |
| 71 | Supply of heavy duty powder coated Air conditioner out door unit mounting bracket |
| 72 | Labour Charges for Installation, Commissioning and Testing of 40 KVA, 3 Phase, 4 Wire copper coiled, air cooled stabilizer including Cable Termination and Earth Connection. |
| 73 | Labour charges for removing exiting switch boxes, wirings, electrical fittings, fans, DB, etc. and breaking the wall & taking out the concealed switch box & same place finished by civil work and the same may be handed over to Lighthouse in charges. (Powerhouse building and IQ) as required |
| 74 | Labour charges for dismantling of Existing OFF Grid solar power plants (1Kw and 4Kw) (removing of solar panels, Solar GI Structure, DC Cable, PVC Pipe, etc. and shifting to temporary shed. |
| 75 | Labour charges for reinstallation, commissioning and testing of 1Kw OFF Grid solar Power Plants using existing Solar panel, Batteries and GI Structure (including civil structure foundation work and Electrical cable, MC 4 Solar Connector, PVC Pipe and etc.,) in Powerhouse roof Top after completion of civil work. |
| 76 | Labour charges for reinstallation, Commissioning and testing of 4Kw OFF Grid solar Power Plants using existing Solar panel, Batteries and GI Structure (including civil structure foundation work and Electrical cable, MC 4 Solar Connector, PVC Pipe and etc.,) in Powerhouse roof Top after completion of civil work. |
| 77 | Labour charges for removing of DVR, DVR Rack, Camera, CCTV Cable and etc in Powerhouse Building |
| 78 | Labour charges for reinstallation of DVR, DVR Rack, Camera, CCTV Cable and etc after completion of civil work in power house building in working condition. |
| 79 | Labour charges for shifting of Steel Cup Board, Work Bench, Wooden Name Boards, Diesel Paral, fire stand, fire buckets, all store materials (including tools) Tables, Chairs, and etc, from powerhouse building to temporary shed and re shifting to existing place after completion of civil works in powerhouse building. |
| 80 | Labour charges for disconnection the Batteries from circuit and shifting of 2Volt, 600AH, Batteries -12Nos provided for Main Light from Powerhouse to temporary shed and reconnection of same batteries. |
| 81 | Labour charges for disconnection the Batteries from circuit and shifting of 12Volt, 150AH, Batteries -16Nos provided for Automation, NAIS, Street Light from powerhouse to temporary shed. |
| 82 | Labour charges for disconnection of all circuit connections and shifting from powerhouse to Temporary shed & reinstallation of Distribution panel with plywood/wooden blank and termination of all loads through UG cable with the cable Glands and commissioning & testing of Distribution Panel at Temporary shed. |
| 83 | Labour charges for disconnection the Automation panel from circuit all connections and shifting from powerhouse to Temporary shed & Installation of Automation panel and termination of all cable. and re shifting to same place after completion of civil works in working condition. |
| 84 | Labour charges for dismantling of 1.5 Ton Split Air Conditioner (Indoor and Outdoor) installed in Bed room at IQ |
| 85 | Labour charges for termination of UG cables at Distribution panel with Gland installed in Powerhouse and DB provided in IQ using by suitable Copper Lugs including materials. |
| 86 | Labour Charges for making trench in the floor by breaking the concrete in the size of 10\\" width x 12\\" depth with plastering suitable for keeping 12\\" width x 6mm thickness chequered plate on the trench complete |
| 87 | Supply of 12\\" width x 6mm thickness x 4 feet length Aluminum chequered plate, suitable for covering the above trench (Each Plate - 12'' width x 4' length x 6mm) |
| 88 | Labour charges for removing of all temporary UG cables laid from temporary shed to Powerhouse after commissioning of NAIS, New Distribution Panel, Stabilizer, Solar power Plants etc installed at new roof casted powerhouse and hand over to station In charge |
| 89 | Plastering work for fixing switch board, DBs pipe entry holes and other miscellaneous works. (Amount inclusive of Labour, materials etc) |
| 90 | Applying wall putty, primer and double coat of painting as like previous. (Amount inclusive of Labour, materials etc) |
| 91 | Additional charges for making an earth pit as the lighthouse is located in a sand area, it is challenging to dig for pipe earthing and other associated difficulties |
| 92 | Miscellaneous items for the purchase of screws, Bolts, Nuts & Washers, drill bits, cable ties, 20/25mm PVC bends, tees, 1,2,3,4way junction boxes, Cutting plates, Fan rod for extension, Fan hook boxes, SS Clamp, Round plate, Hose, etc., |
| 93 | Provision of Garden and Compound Lights |
| 94 | Laying of one number PVC insulated and PVC Sheathed / XLPE power power cable of 1.1KV grade of following size direct in gound including excavation, sand cushioning, protective covering and refilling the trench etc as required |
| 95 | Upto 35 sq.mm |
| 96 | supplying and fixing cable route marker with 10cm x 10cm x mm thick CI plate with inscription there on bolted / welded to 35mm x 35mm x 6mm angle iron, 60cm Long and fixing the same in the ground as required. |
| 97 | Supply of 24 watts LED street Light fitting (New Street Light -14Nos and Existing Street Light -1No) of reputed make |
| 98 | Supply of 10 watts LED garden Light fitting (Bollard type with Pole and LED lantern/luminaire, Aluminum casting, Pole height- 1mtr) of reputed make |
| 99 | Supply of 30 watts LED Gate Light fitting of reputed make |
| 100 | Supply of Metal Modern Decorative Pendant Lights (Hanging Light) of reputed make |
| 101 | Supply and Installation 3\\" Dia Class \\"C\\" GI pipe along with applying 1 coat primer and 2 coat aluminum paint (each 20 feet length) (14Nos. X 10 feet) |
| 102 | Supply and Installation of 1\\" threaded \\"C\\" Class pipe of length along with applying 1 coat primer and 2 coat aluminum paint. (14Nos. X 3 feet) |
| 103 | Supply and Installation of 3\\" to 1\\" GI reducer along with applying 1 coat primer and 2 coat aluminum paint. |
| 104 | Supply and Installation of 8mm thick MS Plate of size 300x300mm (approx. 10Kg each) for Base plate of Street light Poles including gas cutting charges in required size (14Nos x 10Kg = 140Kg) |
| 105 | Supply and fixing of SMC Pole mounted Junction Box Inner Size (200X140X95mm) with 6 Amps Double pole MCB, side hinged door, IP55 with necessary clamps/ Strip, SS screws/Nut and bolt, etc., (New Street Lights -14Nos, Existing Street Lights-3Nos and Gate Lights-1No) |
| 106 | Fabrication of Street light Poles by Cutting, threading, bending and welding with MS base plate, making holes of 3” GI pipe. |
| 107 | Civil Masonry work for making 2’ x 2’ x 2’ pit, erection of pole, and concrete in the ratio of 1:3:4 and 1.5’ x 1.5’ x 1.5’ height brick work and complete plastering and painting for inclusive of material and Labour for Street Light. |
| 108 | Civil Masonry work for making 1’ x 1’ x 1.5’ height concrete in the ratio of 1:3:4 and 1’ x 1’ x 1’ height brick work for Installation of Garden light pole and complete plastering & painting for inclusive of material and Labour for Garden Light. |
| 109 | Labour Charges for Installation of Garden Light pole including wire, PVC Pipe as required. |
| 110 | Labour Charges for demolishing the existing brick missionary work bed of existing street light pole and reconstruction brick missionary work 1.5’ x 1.5’ x 1.5’ height and complete plastering and painting for inclusive of materials and rewiring of Street Light with suitable wires, PVC Pipe, Clamps etc |
| 111 | Electrician (Labour) Charges for wiring and fixing of Metal Modern Decorative Pendant Lights (Hanging Light) in Gazifo 1 and 2 including Wire, PVC pipe, Suitable clamps and etc., |
| 112 | Electrician (Labour) Charges for wiring of street lights, Gate Lights and fitting luminaries, etc., (New street Lights-14Nos, Gate Light-3Nos) including wire, PVC pipe materials. |
| 113 | Miscellaneous items for the purchase of SS screws, Bolts, Nuts & Washers, drill bits, cable ties, SS Clamp, Cable Gland, Copper Lugs, PVC Hose, PVC Pipe for required path way/Road crossing etc., |
| 114 | Miscellaneous items for the purchase of SS screws, Bolts, Nuts & Washers, drill bits, cable ties, SS Clamp, Cable Gland, Copper Lugs, PVC Hose, PVC Pipe for required path way/Road crossing etc., Please Enable Macros to View BoQ information |