| Sl. No. | Item Description |
| 1 | Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority: EXECUTIVE ENGINEER PROVINCIAL DIVISION, BATHINDA NAME OF WORK:- Contract No: Composite Works Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Work Name Item Code / Make Quantity Unit RateRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | CIVIL WORK |
| 3 | Construction of 2nd and 3rd Floor at Judicial Court Complex |
| 4 | Dismantling concreteCement concrete plain 1:3:6 mix |
| 5 | Stripping and stacking iron sheets of a roof including ridging, flashing, eaves boards gutters and down pipes. |
| 6 | Stripping and stacking slate or tiles of a roof. |
| 7 | Earth work excavation in ordinary soil, exclusive of compensation of earth:- Earth work undressed with a combined lead upto 15 metres including breaking of clods. |
| 8 | Dismantling of brick work in cement sand mortar / lime mortar including T&P scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material. & staking the serviceable material with all lifts & lead of 100 metre (By Mechanical Means) |
| 9 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. |
| 10 | Doors of area 3 sqm and below. |
| 11 | Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. |
| 12 | Lintels |
| 13 | Total all Floor |
| 14 | Extra rate for Second Floor |
| 15 | Extra rate for Third Floor |
| 16 | Shelves |
| 17 | Total all Floors |
| 18 | Extra rate for Second Floor |
| 19 | Extra rate for Third Floor |
| 20 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. |
| 21 | Beams |
| 22 | Total all floor |
| 23 | Extra rate for Second Floor |
| 24 | Extra rate for Third Floor |
| 25 | Extra rate for Fourth Floor |
| 26 | Columns (Rectangular & Square) |
| 27 | Total all Floor |
| 28 | Extra rate for Second Floor |
| 29 | Extra rate for Third Floor |
| 30 | Extra rate for Fourth Floor |
| 31 | Circular Columns |
| 32 | Total all Floor |
| 33 | Extra rate for Second Floor |
| 34 | Extra rate for Third Floor |
| 35 | Total qty for all floor |
| 36 | Extra rate for Second Floor |
| 37 | Extra rate for Third Floor |
| 38 | Extra rate for Fourth Floor |
| 39 | Walls |
| 40 | Extra rate for Fourth Floor |
| 41 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 42 | Total qty for all floor |
| 43 | Extra rate for Second Floor |
| 44 | Extra rate for Third Floor |
| 45 | Extra rate for Fourth Floor |
| 46 | Centring and shuttering for Columns ( Square or Rectangular or ply gonal in plain) |
| 47 | Total qty for all floor |
| 48 | Extra rate for Second Floor |
| 49 | Extra rate for Third Floor |
| 50 | Extra rate for Fourth Floor |
| 51 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels |
| 52 | Total qty for all floor |
| 53 | Extra rate for Second Floor |
| 54 | Extra rate for Third Floor |
| 55 | Extra rate for Fourth Floor |
| 56 | Centring and shuttering for stair cases with sloping withsoffits including risers and stringers. |
| 57 | Total qty for all floor |
| 58 | Extra rate for Second Floor |
| 59 | Extra rate for Third Floor |
| 60 | Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or bartering including attached pillasters buttersses etc |
| 61 | Extra rate for Fourth Floor |
| 62 | Centering and shuttering for columns (circular or curved in plain) |
| 63 | Total qty for all floor |
| 64 | Extra rate for Second Floor |
| 65 | Extra rate for Third Floor |
| 66 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.. |
| 67 | Total qty for all floor |
| 68 | Extra rate for Second Floor |
| 69 | Extra rate for Fourth Floor |
| 70 | Extra rate for Fifth Floor |
| 71 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure. |
| 72 | Total Qty for all floor |
| 73 | Extra rate for Second Floor |
| 74 | Extra rate for Third Floor |
| 75 | 12.5mm thick cement plaster 1:5. |
| 76 | Total all floor |
| 77 | Extra rate for Second Floor |
| 78 | Extra rate for Third Floor |
| 79 | Extra rate for Fourth Floor |
| 80 | 20 mm thick cement plaster 1:5 in two coats work. |
| 81 | Extra rate for Second Floor |
| 82 | Extra rate for Third Floor |
| 83 | Extra rate for Fourth Floor |
| 84 | 12.5 mm thick cement plaster 1:4. |
| 85 | Total all floor |
| 86 | Extra rate for Second Floor |
| 87 | Extra rate for Third Floor |
| 88 | Extra rate for fourth Floor |
| 89 | 20 mm thick cement plaster 1:4. |
| 90 | Extra rate for Second Floor |
| 91 | Extra rate for Third Floor |
| 92 | Extra rate for fourth Floor |
| 93 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS ClampU-PVC pipes (working pressure 4kgf. / sqcm)pipe 110 mm dia. |
| 94 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.UPVC 110 mm bend |
| 95 | Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 96 | Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. |
| 97 | Bottom Khurra on ground 1.2m x 0.6m Mtr. Consisting of brick on edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3. |
| 98 | Providing and fixing in position gratings 150mm x 150mm for gully trap.PVC grating |
| 99 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing |
| 100 | Total all Floors |
| 101 | Extra rate for Second Floor |
| 102 | Extra rate for Third Floor |
| 103 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 104 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material |
| 105 | Total qty for all floor |
| 106 | Extra rate for Second Floor |
| 107 | Extra rate for Third Floor |
| 108 | Extra rate for fourth Floor |
| 109 | Marble stone flooring with 12-15 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Udaipur Green Marble Tiles of thickness 12mm to 15mmSlabs sizes above 0.50 sqm |
| 110 | Total qty for all floor |
| 111 | Extra rate for Second Floor |
| 112 | Extra rate for Third Floor |
| 113 | Extra rate for fourth Floor |
| 114 | Marble work of thickness 12-15 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately).Udaipur Green Marble Tiles of thickness 12mm to 15mmSlabs sizes above 0.50 Sqm |
| 115 | Extra rate for Second Floor |
| 116 | Extra rate for Third Floor |
| 117 | Extra rate for fourth Floor |
| 118 | Extra labour for projected nosing of stair case of any shape and design |
| 119 | Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.respects. |
| 120 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.)Size 600x600 mm |
| 121 | Total Qty for all floor |
| 122 | Extra rate for Second Floor |
| 123 | Extra rate for Third Floor |
| 124 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specificationsincluding bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. |
| 125 | Door and window frame of size 113mmx60mmxwith 35mm wide single rebate |
| 126 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specificationsincluding bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. |
| 127 | Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. |
| 128 | Providing & fixing of Box type steel windows,made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flashwelded, with iron fittings including necessary ironhandles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as perrespective items) |
| 129 | Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects. |
| 130 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. |
| 131 | Extra for providing & fixing Steel beading of approved shape steel tube beading size 12mm X 12mm, 18 gauge of approved shape and section with screw for fixing of glass panes instead of glazing clips and metal slash putty in steel doors , windows & Ventilators complete in all respect |
| 132 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. |
| 133 | Providing and fixing stair case railing made out of M.S. square bars 20mm x 20mm as vertical part 0.70 m high fixed with M.S. base plate of 40mm x 40mm x 6mm and flat iron 40mm x 6mm as hand rail complete in all respect. |
| 134 | Providing & fixing 16 guage stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainles steel pipe, Balusters of 40mm dia stainless steel pipe complete in all respects. |
| 135 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. completeI.S.I Designation No. 1 (size of door up to 700mm) |
| 136 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973,Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- |
| 137 | 35mm thick |
| 138 | Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm |
| 139 | Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :300mm x 16mm |
| 140 | Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete |
| 141 | Total Qty for All Floor |
| 142 | Extra rate for Second Floor |
| 143 | Extra rate for Third Floor |
| 144 | Extra rate for Fourth Floor |
| 145 | Providing and fixing tiled false ceiling at height upto 4 mtr. of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending.) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 146 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm |
| 147 | Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications. |
| 148 | Preformed fillers for expansion joints in concrete pavement and structures (non-extruding and resilient type) part-3 Polymer Based (CED 13: building construction practices including painting, varnishing and allied finishing) complete as per IS 1838-3 (2011): |
| 149 | Providing and fixing covering 200mm wide Aluminium Sheet 14 Gauge with gatties and screw on vertical expansion joints one side fixed and one side fixed with slotted holes to allow movement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. |
| 150 | Scraping White And Colour Wash |
| 151 | Scraping Cement Plaster |
| 152 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. |
| 153 | Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. |
| 154 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 155 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 156 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 157 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 158 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping et |
| 159 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 160 | Finishing walls with textured exterior paint of required shade with two or more coats applied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 161 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 162 | Disposal of Malba ouitside the premises including loading and unloading as desired by Engineer in charge. |
| 163 | Providing & Fixing DIAS consisting of teak wood frame work ,20mm thick water proof teak ply board, 12 mm thick water proof ply, finished with polishing painting as per shade approved by the engineer-in-charge,handles, hinges, locks complete as per dra |
| 164 | Credit of Material to be received from dismentling |
| 165 | Tile from dismenling of tile terracing |
| 166 | Bricks from dismenling of Brick work |
| 167 | Brick/Tile bats |
| 168 | Old Doors Complete set as fuel wood |
| 169 | Provision for Building Signage & Signage for PwD act 2016,SS Logo indication board incumbancy board etc |
| 170 | Providing & fixing of Informatory sign board double sided hanging from ceiling Size 1371 x 952mm non glared with retro reflective high intensity Microprismatic grade sheeting type-iv as per ASTM D4956-09 fixed over 4mm thick ACP sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both sided and fixing the same with suitable epoxy base adhesive on back support frame of 40x20x3.2 Stainless Steel supported on a square M.S hollow steel section post 40x40x3.2mm conforming to IS code firmly hanged from ceiling/beam by fixing with expandable fastners complete in all respects, as per specification & as desired by Engineer-in-Charge (Confirming to Harmonised guidelines & standards for Universal accessiblity in India-2021 issued by Ministry of Housing and Urban Affairs Government of India) |
| 171 | Providing & fixing of Informatory sign board double sided hanging from ceiling Size 1371 x 634mm non glared with retro reflective high intensity Microprismatic grade sheeting type-iv as per ASTM D4956-09 fixed over 4mm thick ACP sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both sided and fixing the same with suitable epoxy base adhesive on back support frame of 40x20x3.2 Stainless Steel supported on a square M.S hollow steel section post 40x40x3.2mm conforming to IS code firmly hanged from ceiling/beam by fixing with expandable fastners complete in all respects, as per specification & as desired by Engineer-in-Charge (Confirming to Harmonised guidelines & standards for Universal accessiblity in India-2021 issued by Ministry of Housing and Urban Affairs Government of India) |
| 172 | Providing & fixing of Single Side Signage with provision of Multilingual text integral with minimum 3.8mm thick blue/white or combine Acrylic base plate with upper case san serif words made of white acrylic non glare cut out letter of height not less than 20mm, raised above base plate by not less than 0.8mm and the equivalent workd/s written in Multilanguage i.e Regional, devnagri, English language as required with same specifications with Grade 1 Braille to be integral with the sign face and should be raised not less than 0.5mm above Acrylic base Plate complete in all respects, as per specification & as desired by Engineer-in-Charge (Confirming to Harmonised guidelines & standards for Universal accessiblity in India-2021 issued by Ministry of Housing and Urban Affairs Government of India) |
| 173 | Providing & fixing of 50 mm wide antiskid tape made of slip resistant material colour contrast, edge strip/tape 25mm to 50mm width self adhesive to be fixed on front edge of Stair treads to help people with visual disabliity and elderly even in dim light conditions & reduce the risk of slipping Make 3M or equivalent brand complete in all respects, as per specification & as desired by Engineer-in-Charge (Confirming to Harmonised guidelines & standards for Universal accessiblity in India-2021 issued by Ministry of Housing and Urban Affairs Government of India) |
| 174 | Providing & fixing of 50mm wide high intensitiy reflective, conspicuity tape colour contrast, self adhesive to be fixed on tread of stair case to help people with visual disabliity and elderly even in dim light conditions & reduce the risk of slipping Make 3M or equivalent brand complete in all respects, as per specification & as desired by Engineer-in-Charge (Confirming to Harmonised guidelines & standards for Universal accessiblity in India-2021 issued by Ministry of Housing and Urban Affairs Government of India) |
| 175 | Providing & fixing of Braille labels made of Stainless Steel (Grade-304) Size 170mm x 30mm x 4mm having Braille Dots raised 0.5mm above base plate complete in all respects, as per specification & as desired by Engineer-in-Charge (Confirming to Harmonised guidelines & standards for Universal accessiblity in India-2021 issued by Ministry of Housing and Urban Affairs Government of India) |
| 176 | Providing & fixing of Single sided Tactile Map consisting of visual information and acoustic information including Emergency Evacuation Layout with Provision of Multilingual text integral with minimum3.8mm thick blue/white or Combine Acrylic base plate with upper case san serif workds made of white acrylic non glare cut our letters of height not less than 0.8mm and the equivalent work/s writtenin Multilanguage i.e Regional, devnagri, English language as required with same specification with Grade 1 Braille to be integral with the sign face and should be raised not less than 0.5mm above Acrylic base Plate complete in all respects, as per specification & as desired by Engineer-in-Charge (Confirming to Harmonised guidelines & standards for Universal accessiblity in India-2021 issued by Ministry of Housing and Urban Affairs Government of India) |
| 177 | PUBLIC HEALTH SERVICES |
| 178 | Sub Work-1 |
| 179 | Sub Head-1 Internal Sewerage System |
| 180 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.Single Socket Type B |
| 181 | 110mm o/d SWR UPVC pipe lines laid complete |
| 182 | 90mm o/d SWR UPVC pipe lines laid complete |
| 183 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 184 | For 110mm i/d pipes |
| 185 | Door cap |
| 186 | Single Tee With Door |
| 187 | Single Tee |
| 188 | Elbow 90 Degree (All side socketed) |
| 189 | Vent Cowls |
| 190 | Coupler |
| 191 | P Trap/Floor Trap 110mm x 110mm |
| 192 | For 90mm o/d pipes |
| 193 | Door cap |
| 194 | Single Tee With Door |
| 195 | Single Tee |
| 196 | Vent Cowls |
| 197 | Coupler |
| 198 | Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects. |
| 199 | uPVC Pipe 6 Kgf/cm2 |
| 200 | Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge) |
| 201 | 110mm o/d |
| 202 | 90mm o/d |
| 203 | Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. |
| 204 | M.S. Holder bats clamps for 100mm o/d as per table-1 |
| 205 | M.S. Holder bats clamps for 90mm o/d as per table-1 |
| 206 | Core cutting in RCC slab 125mm dia or 150mm dia withe the help of core cutting machine as per requirement at site & as desired by Engineer-in-Charge. |
| 207 | Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects. |
| 208 | uPVC Pipe 6 Kgf/cm250mm i/d as per table-1 (From Water Cooler & Pantry FT) |
| 209 | Sub Head-2 Internal Water Supply System |
| 210 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 211 | SDR 11 CPVC pipes & fittings 20mm o/d |
| 212 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm |
| 213 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 214 | Through wall 11.43 cm thick Detail as per Table-2 |
| 215 | Through wall 22.86 cm thick Detail as per Table-2 |
| 216 | Providing, fixing and jointing Upvc Union Couplings with Upvc Pipes complete in all respect. |
| 217 | 25mm i/d CPVC Union |
| 218 | 40mm i/d CPVC Union |
| 219 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. |
| 220 | 25mm i/d Brass Ball valves |
| 221 | 40mm i/d Brass Ball valves |
| 222 | Sub Head - 3 Sanitary Installation |
| 223 | Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 224 | Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 225 | Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity (without cistern fitting) size 62x37x67 cm with P trap or S trap and seat cover complete in all respect. |
| 226 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.Detail attached as per Table-3 |
| 227 | Providing and fixing jet spray with 2'-6\\" long PVC pipe.With PTMT nutDetail attached as per Table-3 |
| 228 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect.Detail attached as per Table-3 |
| 229 | Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tubeconnection 300 mm long complete. |
| 230 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. |
| 231 | Size 560mm x 450mm (Under counter oval) |
| 232 | Size 550 mm x 400 mm x 815mm |
| 233 | Providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 234 | Providing and fixing vitreous chinaware standard pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. |
| 235 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 375 mm with PTMT nut |
| 236 | Providing and fixing P.V.C Waste Pipe Collapsible 32mm complete in all respect. |
| 237 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. |
| 238 | C.P brass towel ring |
| 239 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 240 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. |
| 241 | C.P Brass bib cock foam flow without flange |
| 242 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 243 | C.P.brass 15mm Angle valve without flange |
| 244 | C.P.brass 15mm Concealed stop cock with flange |
| 245 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 246 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect.C.P. Brass extension piece, 25mm long to 50mm long |
| 247 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm) |
| 248 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect.C.P. Brass Accessories: |
| 249 | C.P. brass toilet roll holder with flap |
| 250 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.C.P. Brass khunti with 3 pegs |
| 251 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple Layer Tanks |
| 252 | Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball |
| 253 | Brass Ball Cock with rod and Plastic Ball 25mm i/d |
| 254 | Providing and fixing in position cPVC. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. |
| 255 | 25mm i/d Cpvc Tank Nipple |
| 256 | Construction of Plateform complete as per specification & as desired by Enginer-in-charge |
| 257 | For 2000 ltr Water Tank |
| 258 | For 1000 ltr Water Tank |
| 259 | For 500 ltr Water Tank |
| 260 | Providing and fixing in position SS Grab Bar Grade 304 of approved make (to the approval of the Engineer-in-charge) fixed in to wall with brass screws complete in all respect. |
| 261 | 35mm dia 900mm (36”) long |
| 262 | 35mm dia 1200mm (48”) long |
| 263 | Foldable U Type 762mm long |
| 264 | Providing and fixing in position C.P. brass bottle trap 32mm dia with 40 mm seal of approved make (to the approval of Engineer- in-charge) complete in all respect. |
| 265 | Sub Head-4 Flooring and Wall Tile |
| 266 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material |
| 267 | Total All Floor |
| 268 | Extra rate for Second Floor |
| 269 | Extra rate for Third Floor |
| 270 | Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete . |
| 271 | Total All Floor |
| 272 | Extra rate for Second Floor |
| 273 | Extra rate for Third Floor |
| 274 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: i) Ist course of applying cement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm). |
| 275 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement:4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 276 | Total All Floor |
| 277 | Extra Rate for Second Floor |
| 278 | Extra Rate for Third Floor |
| 279 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.. |
| 280 | Total All Floor |
| 281 | Extra Rate for Second Floor |
| 282 | Extra Rate for Third Floor |
| 283 | Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.) |
| 284 | Sub Head -5 Drinking Water Cooler & Air condition |
| 285 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. |
| 286 | Water Cooler Semi Steel Body 80/120 ltr Capacity without Stablizer |
| 287 | AUTOMATIC VOLTAGE STABLIZER:Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:-i) Automatic Voltage Stablizer 2 KVA |
| 288 | Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge) including carriage and fixing in position complete in all respect. |
| 289 | Supplying,errection, testing & commissionng of split type air-conditioners Rating four star or above Cap.1.50 TR confirming to IS:1391 (Part-2)-1992 with amendments No.1& 2 fitted with Rotary compressor operating on Refrigerant R-32 suitable for wall main ting of reputed make such as Carrier/Toshiba/Diakin/Mitsubishi or equivalent make with 4.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects |
| 290 | Supplying,errection, testing & commissionng of split type air-conditioners Rating four star or above Cap.2.00 TR confirming to IS:1391 (Part-2)-1992 with amendments No.1& 2 fitted with Rotary compressor operating on Refrigerant R-32 suitable for wall main ting of reputed make such as Carrier/Toshiba/Diakin/Mitsubishi or equivalent make with 5.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects |
| 291 | Providing laying hard soft copper concealing of copper pipes of dia 12.7mm od (insulation = 13mm)/9.5mm od (insulation = 13m) as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects. |
| 292 | Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete.B) uPVC Pipe 6 Kgf/cm2 |
| 293 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 294 | PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPER CONDUCTOR CABLE: |
| 295 | Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 296 | Overall size 2.5sq.mm (50/0.25mm), 3Core |
| 297 | SubWork - 2 |
| 298 | Sub Head-1 Estate Water Supply |
| 299 | Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. |
| 300 | Earth work upto 1.5 m. Depth All classes of soil except rocky |
| 301 | For 40mm pipe line |
| 302 | INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 303 | SDR 11 CPVC pipes & fittings 25mm o/d |
| 304 | SDR 11 CPVC pipes & fittings 40mm o/d |
| 305 | Sub Head-2 Submersible Pump |
| 306 | Boring with casing pipe for tube well in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested, equipment as required such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect. |
| 307 | Boring with 150mm id Housing Pipe Upto 150 mtr depth BGL |
| 308 | Supplying, assembling, lowering and fixing in vertical position in bore well, un-plasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer – in-charge. |
| 309 | 100 mm nominal size dia. |
| 310 | Supplying, assembling, lowering and fixing in vertical position in bore well un-plasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 311 | 100 mm nominal size dia. |
| 312 | Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. |
| 313 | 100mm internal diameter |
| 314 | Providing & Fixing of Bail Plug |
| 315 | Providing and installing submersible motor 2.00 HP alongwith assembly, Electrical control panel including electrical connections complete in all respects. |
| 316 | Submersible Cable 4.0mm Cable Water proof complete in all respect |
| 317 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B- Class, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. |
| 318 | 50mm i/d |
| 319 | Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects. |
| 320 | Development and Stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 321 | Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect. |
| 322 | Supplying at site of gravel of 1/16\\" to 1/8\\" sizes including pouring and packing in the annular space between the pipes assembly and the bore.The gravel should be free from, dust,dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe) |
| 323 | Supplying and fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects. |
| 324 | Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.) |
| 325 | Sub Work-3 |
| 326 | Sub Head-1 Fire Fighting Arrangements |
| 327 | Providing and fixing of FIRE EXTINGUISHER ABC powder type (Stored pressure) as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 6kg Capacity4 Kg. Capacity |
| 328 | Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 4.5 Kg. Capacity |
| 329 | Providing and fixing of FIRE EXTINGUISHER, Mechanical Foam Type 9 ltr IS: 15683 Stored Pressure type complete with all accessories as per Manufactures Specification. ISI Mark of approved makecomplete in all respect. |
| 330 | Sub Work-4 |
| 331 | Sub Head-1 Dismantling |
| 332 | Shifthing of OLD AC's Outdoor From (First Floor Roof to wall) complete in all respects. |
| 333 | Disassembling, Shifting of HDPE Water tank (First Floor Roof to Third Floor Roof) and fixing on third floor roof complete in all respects. |
| 334 | Dismantling, disjointing, removal of G.I. pipe lines, specials, valves and fittings complete in all respects. |
| 335 | 25mm internal diametre pipe line. |
| 336 | 40mm internal diametre pipe line. |
| 337 | Credit of old dismantalled material i.e. G.I pipe25 mm = 2.43 kg/mtr |
| 338 | Credit of old dismantalled material i.e. G.I pipe40 mm = 3.6 kg/mtr |
| 339 | ELECTRICAL SERVICES |
| 340 | Providing Internal Electrical Installations: |
| 341 | POINT WIRING: |
| 342 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 343 | Wiring fan point with sheet metal fan box |
| 344 | Wiring light point |
| 345 | Wiring call-bell point |
| 346 | Wiring 3 pin 6 Amp. wall socket point |
| 347 | Wiring 3 Pin 6 Amp. Plug control comprising wall socket point |
| 348 | Wiring 3 pin 16/20 amp. power plug control point |
| 349 | Wiring light point without control switch. |
| 350 | Wiring light point with double control switches. |
| 351 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 352 | Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). |
| 353 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 354 | Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 355 | SUPPLY AND ERECTION OF WIRING ACCESSORIES:Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- |
| 356 | Ceiling Rose (Flush Piano type) |
| 357 | Call Bell 220/230 volts AC Ding Dong |
| 358 | LED'S FIXTURES & FANS: |
| 359 | Supply and erection of Slim Recessed mounted, Round downlighter 18 watt with Pressure die cast aluminium housing & polycarbonate diffuser with surge protection 10KV and efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 %, housing & driver shall be of same brand, supported with LM 79 reports not more than 2 years old from NABL /UL accredited laboratory complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. The certification and specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 360 | Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 361 | Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 362 | Supply and erection of Recessed mounted 36watt LED panel (including LED driver) with CRCA sheet having efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 363 | Supply and erection of BEE 3-Star rating AC Ceiling Fan 1200mm (48\\") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site. |
| 364 | Supply and erection of Wall Fan Plastic Body 400MM, 16\\" including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. |
| 365 | Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. |
| 366 | OCCUPANCY SENSORS: |
| 367 | Supply and erection of Ceiling mounted Occupancy based PIR sensor (360 degree)with installation height 2.5mts ,8.5 Amps resistive load, Detection dia 8M,time delay - 5s to 59 mins , Light level threshold - 5 to 1275 Lux ,IP - 20,Sensitivity Adjustment, Walk LED test, with additional options like walkthrough, daylight set point, vacancy . |
| 368 | SUSPENSION RODS FOR CEILING FANS: |
| 369 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 370 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. |
| 371 | CONDUIT PIPE & COPPER WIRES: |
| 372 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 373 | Heavy gauge PVC conduit pipe 20mm dia. (ISI marked) Flushed |
| 374 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 375 | Heavy gauge PVC conduit pipe 32mm dia. (ISI marked) Flushed |
| 376 | Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed |
| 377 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 378 | Overall size 1sq.mm (Un-sheathed) |
| 379 | Overall size 1.5sq.mm (Un-sheathed) |
| 380 | Overall size 2.5sq.mm (Un-sheathed) |
| 381 | Overall size 4sq.mm (Un-sheathed) |
| 382 | Overall size 6sq.mm (Un-sheathed) |
| 383 | Overall size 10sq.mm (Un-sheathed) |
| 384 | Overall size 16sq.mm (Un-sheathed) |
| 385 | Overall size 25sq.mm (Un-sheathed) |
| 386 | SUB DISTRIBUTION SYSTEM: |
| 387 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 388 | TP&N Vertical Double Door Distribution Board 8 way each. |
| 389 | Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:- |
| 390 | Cable End Box for TPN Vertical 4/8/12Way |
| 391 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 392 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 393 | MCB Four Pole 40amp. (10kA, Curve-C) |
| 394 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 395 | MAIN DISTRIBUTION SYSTEM: |
| 396 | MAIN VERTICAL DISTRIBUTION BOARD (EMERGENCY): TPN 4Way to feed MCB DB's (EMERGENCY LOAD) ON GROUND FLOOR |
| 397 | Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- |
| 398 | TP&N Double Door Vertical DB's 4 way each (With provision of FP MCCB upto 125amp) |
| 399 | MCCB's (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 400 | MCCB Four Pole 80amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 401 | MCCB Four Pole 125amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 402 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 403 | MCB Triple Pole 40amp. (10kA, Curve-C) |
| 404 | MCB Triple Pole 63amp. (10kA, Curve-C) |
| 405 | RISING MAIN: (IN ELECTRICAL DUCT FOR 2ND & 3RD FLOOR) |
| 406 | EMERGENCY RISING MAIN: |
| 407 | Supply, Installing testing and commissioning of 160A, 25KA Air Insulated Type Rising Mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every meter, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 408 | Supply, installation, testing & commisioning of 160 Amp Main End Feed Unit Box (with provision of MCCB but without MCCB )on the existing Air Insulated rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C supply with Flange End, Rotary Handel, box made with 1.6mm thick G.I sheet steel enclosure (IP54) duly powder coated complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 409 | NORMAL RISING MAIN: |
| 410 | Supply, Installing testing and commissioning of 200A, 25KA Air Insulated Type Rising Mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every meter, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 411 | Supply, installation, testing & commisioning of 200 Amp Main End Feed Unit Box (with provision of MCCB but without MCCB )on the existing Air Insulated rising mains for use on 3 phase 4 wire 415 V, 50Hz A.C supply with Flange End, Rotary Handel, box made with 1.6mm thick G.I sheet steel enclosure (IP54) duly powder coated complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 412 | Supply, installation, of Tap off box for with provision of MCCB Four Pole 100Amp. (Excluding MCCB Cost) complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 413 | Supply, installation, of Tap off box for with provision of MCCB Four Pole 125Amp. (Excluding MCCB Cost) complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 414 | MCCB's (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 415 | MCCB Four Pole 80-100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 416 | MCCB Four Pole 125amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 417 | MCCB Four Pole 160amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 418 | MCCB Four Pole 200amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 419 | Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- |
| 420 | PVC flexible pipe 40mm dia. |
| 421 | Supply and erection of Compression glands, Locking arrangement, Checknuts for PVC flexible pipe complete with as required:- |
| 422 | PVC compression Socket gland 40mm dia. |
| 423 | EARTHING SYSTEM (INDOOR): |
| 424 | COPPER EARTHING 8SWG :- Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 425 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long |
| 426 | Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- |
| 427 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) |
| 428 | COPPER EARTHING :-(Upto 14 metre in Length):-Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 429 | Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length) |
| 430 | COPPER EARTHING STRIP (As Additional Length):Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- |
| 431 | Additional Length 20mm x 3mm thick Copper Tape . |
| 432 | INDOOR LT CABLES, CABLE TRAY, DWC PIPE , BRASS GLANDS & THIMBLES: |
| 433 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 434 | Overall size 6sq.mm (2Core) Un-armoured (Loose) |
| 435 | Overall size 16sq.mm (4 Core) Un-armoured (Loose) |
| 436 | Overall size 95sq.mm (3½ Core) Un-armoured (Loose) |
| 437 | Overall size 150sq.mm (3½ Core) Un-armoured (Loose) |
| 438 | CABLE TRAY:Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 439 | Cable Tray Size 300mm x 50mm x 50mm (2mm thick) |
| 440 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 441 | Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.) |
| 442 | Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.) |
| 443 | Double walled corrugated (DWC) HDPE pipe120/103.50mm (outer/ inner dia.) |
| 444 | Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:- |
| 445 | Brass Gland for Aluminium cable 2/3/4 Core size 6sq.mm |
| 446 | Brass Gland for Aluminium cable 2/3/4 Core size 16sq.mm |
| 447 | Brass Gland for Aluminium cable 3/3½/4 Core size 95-120sq.mm |
| 448 | Brass Gland for Aluminium cable 3/3½/4 Core size 150sq.mm |
| 449 | Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- |
| 450 | Aluminium thimble cable Core size 4 - 6sq.mm |
| 451 | Aluminium thimble cable Core size 10 -16sq.mm |
| 452 | Aluminium thimble cable Core size 50sq.mm |
| 453 | Aluminium thimble cable Core size 70sq.mm |
| 454 | Aluminium thimble cable Core size 95sq.mm |
| 455 | Aluminium thimble cable Core size 150sq.mm |
| 456 | Supply and erection of heavy duty Copper thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely:- |
| 457 | Copper thimble cable Core size 4 - 6sq.mm |
| 458 | Copper thimble cable Core size 10 - 16sq.mm |
| 459 | SAFETY EQUIPMENTS: |
| 460 | Providing and fixing of 4.5 Kg. Capacity FIRE EXTINGUISHER,CO2 type as per IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect |
| 461 | Providing and fixing of 6 Kg. Capacity FIRE EXTINGUISHER, ABC Powder type (stored pressure) asper IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect |
| 462 | Providing Advance Lightning Protection System: |
| 463 | Supply, erection, testing & commisioning of Early Streamer Emission (ESE) type Lightning Protection Complete with Lightning Air Terminal. The System should be corrosion resistant stainless steel chrome body capable of working in hazardous atmosphere and protecting against direct Lightning point as well conducting /diverting it to earth completely after tracing the Lightning in advance. As per NF C 17-102:2011 the air terminal should be tested for Lightning impulse current (10/350 micro sec) =100 KA and for local certification the air terminal should be tested for switching impulse current of 40 KA (8/20 micro sec) as per CPRI with 5 positive and 5 negative impulse. The ESE Terminals shall offer a protection radius of 79mtr., Level-1 High Protection and preferably to be mounted on roof top and center of the building / blocks with the highly insulated polyplastic adaptor with the Mast. (Its working principle evolves from local electrostatic field that develops naturally around the system as a thunderstorm begins to gather. In the event of descending lightning, an inbuilt triggering device generates high tension pulses at the conductor tip, causing a ‘corona effect’.) Protection radius of 79Mtr at level 1 & 107 Mtr at level 4 |
| 464 | Supply and fixing of GI Mast 5 mtr. height along with suitable base plate for mounting the terminal along with highly insulated adopter to mount ESE Air Terminal with the Mast.The Adapter shall have suitable Metal connector /Connecting point in such a way the top portion shall be electrically connected to the central tip of the ESE terminal and bottom portion connected to the down conducto, stray wires along with support shall be securely fixed with base plate and gauge wires where ever required. |
| 465 | Supply and installation of Lightning Strike Counter (6 digit display) of non-resettable (electromechanical) type which allows the automatic counting of the strikes received by the lightning protection system. This information is used to enhance lightning protection security & increase the effectiveness of inspection & maintenance procedures. It should be in IP-65 enclosure with minimum sensitivity of 1KA and maximum capacity 100KA. No external power source is required. It should be installed always 2 mtrs. above the ground level. |
| 466 | Supply & erection of test Link of non-corroding, weather proof, water proof polycarbonate IP 65/55 enclosure including providing of 2 Nos. of insulated supports with suitable holes prefitted nuts & bolts to fix the down conductor & earth wire. The transparent cover fitted at approximately 500-1000mm from ground level shall be provided on each down conductor. |
| 467 | Supply, installation & testing of chemical earthing (Maintenance Free Earthing) system with UL approved copper bonded rod and exothermically welded copper busbar both tested by CPRI at 50kA Fault Current. A copper bonded steel rod shall have 3000 mm length and 17.2 mm dia. with copper coating thickness of minimum 250 microns. Along with earth enhancement compound tested by ROHS complying IEC 62561-7 in a sealed bag of minimum 50 kg (25 kg Bag x 2). A copper clad steel solid ground wire of 8 mm dia. for interconnecting earth pits. Each earth pit shall be covered with heavy duty weather proof environment friendly polyplastic earth pit chamber. The grounding minerals should not be pollute the ground water. The grounding minerals shall be tested & certified for the resistivity of less than 0.12 ohm-mtr. |
| 468 | Cost of pole foundation with earth work in excavation in foundations trenches etc. 0.25 meter below ground level, Cement Concrete 1:4:8 with stone ballast, Reinforced cement concrete M-20,Cold twisted deformed (Ribbed/tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008 complete in all respect as desired by engineer in charge. |
| 469 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 470 | Overall size 70sq.mm (Un-sheathed) (Conductor connected the air terminal to earthing) |
| 471 | Providing EPABX System: |
| 472 | Supply Installation Testing and Commissioning of Analog phone with caller id and hand free facility complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 473 | Supply Installation Testing and Commissioning of 50 Pair MDF with Krone complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 474 | Supply Installation Testing and Commissioning of 100 Pair MDF with Krone complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 475 | Supply, Installation Testing and commissioning of unarmoured 2 Pair 0.5 sq. mm copper conductor PVC insulated Cable for Telephones in existing Conduit complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 476 | Supply, Installation Testing and commissioning of 50 Pair 0.5sq. mm copper conductor cable manufactured as per ITD specification with up to amendments for Telephones in existing Conduit complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 477 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 478 | Wiring Telephone socket point RJ11 (one module) |
| 479 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 480 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 481 | Providing Networking System along with allied accessories: |
| 482 | Supply, Installation and Comissioning of 24* 10GE SFP+ ports & 4*100GE QSFP28 ports Layer 3 10GbE Managed Switch with 2 internal AC power supply, RJ-45 console ports, 10/100/1000BASE-T RJ-45 Ethernet Management Port, Switching Capacity 1.280 Tbps, MAC Address Table 32K, Packet Forwarding 952 MPPS, Packet Buffer Memory 4 MB, Flash 32 MB, DRAM 1 GB, Power Input 100 to 240 V AC, 50Hz 10%, 4 Smart Internal Fans, Operating Temperature 0 to 50 °C, VSS up to 4 Switches, 802.3x Flow Control, HOL Blocking Prevention, 802.1D, 802.1w, 802.1s, Root Guard, Loop Guard, Jumbo Frame 9Kb, 802.1AX Link Aggregation, ERPS, Port mirroring, VLAN mirroring, L2 protocol tunneling, Loopback Detection (LBD), IGMP Snooping,, IGMP v1/v2/v3 Snooping, 2K IGMP groups, IGMP Snooping Querier,, Host-based IGMP Snooping Fast Leave,, MLD Snooping,, MLD v1/v2 Snooping,, Supports 256 groups,, Host-based MLD Snooping Fast Leave,, MLD Snooping Querier, 802.1q, Double VLAN (Q-in-Q), Port-based Q-in-Q, Selective Q-in-Q , Port-based VLAN, MAC-based VLAN, Private VLAN, VLAN group, Max. 4K static VLAN groups, Max. 4094 VIDs, ISM VLAN (multicast VLAN), VLAN trunking, GVRP, 802.1p Quality of Service, WRED,, Bandwidth Control,, Port-based (ingress/egress, min. granularity 64 Kb/s),, Queue Handling,, Strict Priority (SP) Weighted Round Robin (WRR), WFQ, DRR, Access Control List (ACL), Port isolation, Port security, and “IP+MAC+port” binding, MAC Sticky, DHCP Snooping and option 82, DAI & IP source guard,, IEEE 802.1x, Radius and Tacacs+,, L2/L3/L4 ACL flow identification and filtration Anti-attack from, DDoS, TCP’s SYN Flood, UDP Flood, etc. Broadcast /multicast /unknown unicast storm-control. MD5, SHA-256, RSA-1024, AES256, IPv6 Neighbor Discovery (ND), VRRP v2/v3, Static routing IPv4 8K, IPvv6 4K, Policy-based Route (PBR), Bidirectional Forwarding Detection (BFD), BGP, BGPv4, OSPF v2/v3, RIP v1/v2, Web-based GUI, SSL (HTTPS), SNMP v1/v2c/v3, TFTP Client for IPv4/IPv6, FTP Client for IPv4/IPv6, IPv4 SFTP Server, RMONv1, RMONv2, LLDP/LLDP-MED, DHCP/DHCPv6 Local Relay, DHCP Server, ISATAP, IGMP v1/v2/v3, PIM-DM/SM, MLD v1/v2, 802.3ah Ethernet Link OAM, UDLD/DULD, Dying Gasp, 802.1ag CFM, Y.1731 OAM, Optical Transceiver Digital Diagnostic Monitoring (DDM). OEM Should be ISO 45001, ISO 27001 & ISO 14001 Certified, OEM Should have Certificate for Industrial Cyber Security Capability (Like - IEC-62443-4-1:2018 or Equivalent) complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 483 | Supply, Installation and Comissioning of 24-port 1G Base-Stackable Managed Switch. Physical Interfaces, 24 # 1G Base-T Copper Ports, 02 # 1/10G Base-T Copper Ports, 02 # 1/10G Base-X Fiber SFP+. Memory RAM: 1 GB, Packet buffer memory: 16 MB, Flash: 256 MB, Performance, Stack height: 8 switches, Switching fabric: 128 Gbps Line-Rate (non blocking fabric), Throughput: 95.2 Mpps, Address database size: 16,000 MAC addresses (48-bit MAC address), Number of VLANs: 4,093 (IEEE 802.1Q) simultaneously, Jumbo frame support: up to 9K packet size, Mean time between failures (MTBF): 1,328,968 hours (~151.7 years), L2 Services Protocol based VLAN, Guest VLAN, Voice VLAN, Double VLAN Tagging (QoQ), GARP with GVRP/GMRP, MVR (Multicast VLAN Registration), Multiple Registration Protocol (MRP), Multicast VLAN Registration Protocol (MVRP), LAG Member Port Flaps Tracking, LAG Hashing, Distributed Link Aggregation, STP, RSTP, MSTP, Per VLAN STP (PVSTP) with FastUplink and FastBackbone, Per VLAN Rapid STP (PVRSTP), L3 Services IGMP Proxy Static Routing (IPv4, IPv6) Port based Routing ECMP Static Routing Port Based Routing VLAN Routing RIP v1 and v2 OSPF v2 and v3 OSPF Flood Blocking Route RedistributionVRRP VRRP Route/Interface Tracking IEEE 802.1p CoS Diff Serv QoSWRED (Weighted Deficit Round Robin) Strict Priority queue technology IP DSCPIP Precedence IP TOS Security Broadcast, Multicast and Unicast Network Storm Protection CPU Protection DoS attack protection ICMP throttling IEEE 802.1x Radius Port Access Authentication 802.1x MAC Address Authentication Bypass (MAB) Port Security Dynamic ARP Inspection MAC Filtering Port MAC Locking Management ISDP (Industry Standard Discovery Protocol) Out of band Management 802.1ab LLDP and LLDP-MED SNMP v1, v2 and v3 RMON 1, 2, 3, 9 Command Line Interface (CLI), Web-based graphical user interface (GUI) Telnet SSH v1/v2 SSL/HTTPS and TLS v1.0 for web-based access File Transfer (uploads, downloads) through TFTP/HTTP SCP/ SFTP/ HTTPS, Syslog Non disruptive Config Management Remote Port Mirroring (RSPAN)802.1x MAC Address Authentication Bypass (MAB) Environmental Operating Temperature: 32° to 122°F (0° to 50°C)Warranty Lifetime Hardware Warranty Lifetime Free Chat and Mail Support Lifetime free latest firmware support complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 484 | Supply, Installation and Comissioning of Category 6A Unshielded Twisted 4 pair shall be compliant with ANSI/TIA/EIA-568-C. 2 and & ISO/IEC 11081. , 10GBASE-T (10-Gigabit Ethernet) standard. , Category 6A should operate on bandwidth up to 500MHz. , Category 6A can run 10GBASE-T at 100 meters. , The conductors should be twisted in pairs with four pairs and Insulation should be high density polyethylene. , Copper conductor diameter should be 23 AWG. , Cable outer sheath should be LSZH. , Cable outer diameter should be 7.6mm ± 0.3mm. , Electrical Properties - Conductor Resistance: ≤ 9. 38Ω/100m, Mutual Capacitance: ˂ 5. 6nF/100m, Resistance Unbalance: 5% Max, Delay Skew: < 45nS, Characteristic Impedance: 100 ± 15Ω, Mechanical Properties - Bending Radius should be 8 x cable diameter. , Operating temperature Range 0°C to +60°C, Need to submit transmission characteristics report per 100 meter. The report at least includes Maximum Attenuation, RL, NEXT and PSNEXT data. OEM for the cable Box and all copper Accessories should be from same OEM.OEM Should be International certification for the ISO 45001 Health and Safety Management System, ISO 9001 Quality Management System, ISO 14001 Environmental Management System, and ISO 14064-1 Greenhouse Gas Inventory Standards. OEM should have Indian based operation at least for a period of 20+ years and should have an Annual Turnover of Rs. 500 Crores and above in any of last three consecutive Audited Financial years. (To ensure only principal networking companies participate having strong Product , Support and Service.) complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 485 | Supply, Installation and Comissioning of Patch Panel Cat 6 A UTP Keystone Type- 24 Port-Fully Loaded Category 6A UTP Patch Panel should be 24 Port 1U Size. , Mounts in standard 19 inch racks. , Patch panel should have cable manager for improvement management. , Patch panel should be made from SPCC and 1. 5mm or higher thickness with black colour painted. , RJ-45 Jack housing should be PBT + glass fiber, UL-94V-0. , RJ-45 Jack contact material should be phosphor bronze with nickel plated, RJ-45 Jack shield material should be phosphor bronze with tin plated. complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 486 | Supply, Installation and Comissioning of CAT6A UTP 24AWG PATCH CORD:1M Category 6A patch cords with four pair twisted cable terminated with RJ45 modular plugs at both the ends. Patch Cord should have TIA/EIA 568C. 2 standard. Shall be backward compatible with Category 5e and Category 6 systems. Category 6A patch cord should be 100% factory made and performance tested. Category 6A patch cord length requires – 1 meter & 3 meter. Patch cord conductor should be 24 AWG, multi-strands. , Patch cord conductor metal should be made from bare copper. , Jacket material should be LSZH. , Heat resistance of patch cord should be 75° Celsius. Modular Connector/Plug - Patch cord plug should be 50U gold plated. , Contact blade of plug should be made from copper alloy. , Category 6A patch cord plug should have maximum 500 MΩ, 1000V DC/min insulation resistance. , Dielectric withstanding voltage should be 1000V DC/min, <0. 5A. OEM for the cable Box and all copper Accessories should be from same OEM. complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 487 | Supply, Installation and Comissioning of CAT6A UTP 24AWG PATCH CORD:3M Category 6A patch cords with four pair twisted cable terminated with RJ45 modular plugs at both the ends. Patch Cord should have TIA/EIA 568C. 2 standard. Shall be backward compatible with Category 5e and Category 6 systems. Category 6A patch cord should be 100% factory made and performance tested. Category 6A patch cord length requires – 1 meter & 3 meter. Patch cord conductor should be 24 AWG, multi-strands. , Patch cord conductor metal should be made from bare copper. , Jacket material should be LSZH. , Heat resistance of patch cord should be 75° Celsius. Modular Connector/Plug - Patch cord plug should be 50U gold plated. , Contact blade of plug should be made from copper alloy. , Category 6A patch cord plug should have maximum 500 MΩ, 1000V DC/min insulation resistance. , Dielectric withstanding voltage should be 1000V DC/min, <0. 5A. OEM for the cable Box and all copper Accessories should be from same OEM. complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 488 | Supply, Installation and Comissioning of Category 6A keystone jacks are RJ45, 8 position 8 contact socket. Category 6A keystone jacks are suitable for 22-26 AWG stranded and solid wire. Category 6A keystone jacks are compatible with both 110 & Krone punch down tools. jacks shall be backward compatible with Category 6, and 5e cords and cables. jacks shall be of a universal design supporting T568 A & B wiring. Mechanical Characteristics - Category 6A keystone jacks housing made from PC, UL94V-2. RJ45 Jack contact material should be phosphor bronze with Nickel plated. IDC contact material should be phosphor bronze with tin plated. OEM for the cable Box and all copper Accessories should be from same OEM.complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 489 | Supply, Installation and Comissioning of Face Plate should be able to terminate one Cat 6A keystone jack. Face plate material should be ABS with white colour. The face plates should have inbuilt shutter for protection against dust. Face plate should be able to supply with label holder. Screw and screw hole covers to be supplied with face plate. Should supplied with suitable back box. It should be made from HIPS / High plastic material. complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 490 | Supply, Installation and Comissioning of 6 core Single mode outdoor Fiber Outdoor Loose Tube Armoured 9/125μm OS2 Type Optical Cable.Fiber Cable should be containing upto 72 optical fibres in water blocked loose tubes and solid polyethylene fillers, total of 6 elements laid-up around a fibre reinforced plastic (FRP) central strength member, water blocked interstices, taped, corrugated steel tape armoured, polyethylene overall sheathed. Anti-Rodent/Termite.Central Strength Member should be FRP (Fibre Reinforced Plastic) 2.0 mm OD.Outer sheath should be of UV proof HDPE Black.Fiber cable Should be Max.Tensile Strength: 3500N Max. Crush Resistance: 6000N/10 cm.Operating Temperature range should be -40°C to +70°C.Cable should be of ROHS Compliant.Approved Make SIEMON/MOLEX/Legrand/PANDUIT complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 491 | Supply, Installation and Comissioning of 1G Base-LR Single-Mode, 10KM, SFP+ (1310 nm). All Switches, Wireless and its and Networkiing Components from Same OEM.OEM should be present as Leader in Gartner Quadrant from last 5 years,OEM Authorization should be required on lettehead complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 492 | Supply, Installation and Comissioning of LC-SC Single Mode Fiber patch cord 2 mtr should be SC or LC LSOH Jacket ‐ Reduces toxic / corrosive.SC to LC duplex fiber optic patch cord single mode OS2 9/125 micron.Fiber patch cord should be 100% Factory polished and tested.Cable diameter should be 1.6 mm.Jacket color should be Industry Standard Colour ‐ OS1‐Yellow.Buffer diameter Should be 900 micron meter.Fiber patch cord should be of ROHS Compliant complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 493 | Supply, Installation and Comissioning of SC Pigtail, Simplex - Single Mode.PIGTAIL SC SM SIMPLEX LENGTH- 1m ,Pigtails Corning G652D, G657A, G657Bsingle-mode /Insertion Loss Typical:<0.2dB, Max. 0.3dB(MTRJ: Max. 0.5dB)/Return Loss PC>45dB, UPC>50 dB,APC>60dB /ConnectorFerrule Ceramic, (MTRJ: PS- Polyphenylene Sulphide )Apex Offset <50um / Fiber Height ±100nm , End-face Radius of Curvature 7mm < R < 25mm (Excluding MTRJ)/ Repeatability <0.2dB 1,000 times mating cycles / Working Temperature – 20C ~+ 65C. complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 494 | Supply, Installation and Comissioning of 12 Port Fully loaded single mode, Rack-mountable, SC/LC type LIU. Enclosure should be CRS (cold rolled steel).Should be fully Secured with Lockable and Secured Steel doors and Comes multiple entry points.Enclosure should be finish black powder Coat.Enclosure should be accepts SC Duplex and Quad LC Adapters.Should be loaded with SC/LC type adopter plate.Pigtail should be 100% Factory polished, tested and guaranteed performance.Should be complete with splicing tray and other standard accessories.Should be of ROHS Compliant.complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 495 | Supply, Installation and Comissioning of 24 Port Fully loaded single mode, Rack-mountable, SC/LC type LIU. Enclosure should be CRS (cold rolled steel).Should be fully Secured with Lockable and Secured Steel doors and Comes multiple entry points.Enclosure should be finish black powder Coat.Enclosure should be accepts SC Duplex and Quad LC Adapters.Should be loaded with SC/LC type adopter plate.Pigtail should be 100% Factory polished, tested and guaranteed performance.Should be complete with splicing tray and other standard accessories.Should be of ROHS Compliant complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 496 | Supply, Installation, Testing and Commissioning of Wall Mount 15U x 600 W x 600 D , Front Glass Door (tinted, Toughened) with Lock & Key, 2 pairs of 19\\" Mounting Rails with U-Marking , Welded Side Walls, Min Accessories : 1U Cable Manager (1), Hardware Packet (1 Pkt), 6 Socket 5 Amp. Power Distribution Unit (1 No), Roof Mounted Fan Unit / 90 CFM /230V AC. as per DIN 41494 Standards. complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 497 | Supply, Installation, Testing & Commissioning of 1 KVA UPS with Input power factor - 0.99, Output power factor - 0.8, OVCD inbuilt , DC V 36v, Efficiency : Above 90% complete in all respects as approved and desired by the Engineer in-charge at site. |
| 498 | Supply and erection of Concealed Metal Boxes of various sizes (1/2M, 3M, 4M, 6M, 8M, 12M, 16/18M) with brass lugs recessed in wall for mounting modular accessories including fixing and other petty material etc., including the cost of cutting and filling up of chases (with finishing the surface):-Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module),covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 499 | Powder Coated Concealed Metal Box with Brass Lugs One/Two Module |
| 500 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 501 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 502 | Providing CCTV System: |
| 503 | Supply, erection, testing & commissioning of Indoor STQC Approved 3 MP IP WDR IR Rugged Mini Dome Camera OPERATIONAL: Video Standard: NTSC / PAL, Scanning System: Progressive, Image Sensor: 1/2.7” CMOS, Sensor Size (H x V): 4.608 mm x 2.592 mm, Number Of Pixels (H x V): 2304 x 1296, Minimum Illumination (Color/BW): .005 Lux / F1.6 (Color, 30 IRE), 0 Lux / F1.6 (IR ON), S/N Ratio: 50 dB, Electronic Shutter Speed: 1/8 ~ 1/32,000, IR Distance: up to 40 m, IR Light Control, Smart IR ( Auto / Manual ) / OFF, IR Light Number: 2, Day/Night: Auto (ICR) / Color / BW, Backlight Compensation: WDR, BLC, HLC, White Balance: Auto/Tungsten/ Fluorescent/ Daylight/Shadow/Manual, Gain Control: 0-100%, Wide Dynamic Range: 120 dB, Noise Reduction: 2D / 3D DNR, Lens: : 2.8 mm Fixed Iris, F1.6, Angle Of View: H: H:88°°, V:47°, Privacy Masking: Off / On (4 Areas), Defog: Not supported, Local Storage: Micro SD (up to 256 GB), Alarm Inputs/Outputs: Not supported, Pan Range: 0°-330°, Tilt Range: 0°-75°, Rotation Range: 0°-337°, Video Compression:H.265 HEVC/H.264/MJPEG, Smart Codec, Resolution: 1st: 2304 x 1296 / 1920 x 1080 / 1280 x 720 2nd: 704 x 576 (PAL) / 704 x 480 (NTSC) / 640 x 480 / 352 x 288 (PAL) / 352 x 240 (NTSC) 3rd: 640 x 480 / 352 x 288 (PAL) / 352 x 240 (NTSC) / 320 x 240, Number of Video Streams: 3 (2 for encryption), Frame Rate*: MAX 30 fps, Bit Rate*: 100K ~ 6 Mbps, Audio Compression: Not supported, Audio Stream: Not supported, Audio Interface: Not supported, NETWORK: Ethernet: 10 Base-T/100 Base-TX Ethernet (RJ-45), Supported Web Browsers: Chrome / Edge, Supported OS: Microsoft Windows 10, Protocols**: IPv4, IPv6, TCP / IP, HTTP, HTTPS, RTSP / RTP / RTCP, IGMP / Multicast, SMTP, DHCP, NTP, DNS, QoS, SNMP, 802.1X, UDP, ICMP, ARP, TLS, Interoperability: ONVIF Profile G/S/T, Maximum Users Access: 10 Users, Security: User account and password protection, HTTPS, IP Filter, Digest authentication, TLS1.2 only, Stream encryption, AES128 / 256, SSH / Telnet closed, PCI-DSS compliance, EVENTS / ANALYTICS: Built-in Video: Analytics, Motion Detection, Tampering, Event Type: Video motion detection,Recording notification, Event Linkage: Event notification using Email and MicroSD card, Region Of Interest: 8, ELECTRICAL: Power Supply: DC12V, PoE (IEEE 802.3af) (Class 0), Power Consumption (Max): MAX 3.6 W, MECHANICAL: Dimensions: Ø110.0 mm × 85.6 mm (Ø4.33” × 3.37”), Dome Diameter Ø78.2 mm (3.08”), Product Weight 0.56 kg (1.23 lb), Package Weight 0.65 kg (1.43 lb), Body Material Die-cast aluminium housing, ENVIRONMENTAL: Operating Temperature: Starting Temperature:-40°C ~ 60°C (-40°F ~ 140°F), Working Temperature: -40°C ~ 60°C (-40°F ~ 140°F), Relative Humidity Less than 90 %, non-condensing, Ingress Protection IP67, Impact Resistance IK10, REGULATORY: Emissions: FCC PART 15, CE (EN 55032), Complies with RCM and UKCA, Immunity CE(EN 50130-4), Complies with RCM and UKCA, Safety: UL LISTED TO UL/CSA 62368-1, CE(EN 62368-1), Complies with RCM and UKCA, RoHs: CE(EN 63000).complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 504 | Supply, erection, testing & commissioning of Outdoor STQC Approved 3 MP IP WDR IR MFZ Bullet Camera OPERATIONAL: Video Standard: NTSC / PAL, Scanning System: Progressive, Image Sensor: 1/2.7” CMOS, Sensor Size (H x V): 4.608 mm x 2.592 mm, Number Of Pixels (H x V): 2304 x 1296, Minimum Illumination (Color/BW): .005 Lux / F1.6 (Color, 30 IRE), 0 Lux / F1.6 (IR ON), S/N Ratio: 50 dB, Electronic Shutter Speed: 1/8 ~ 1/32,000, IR Distance: up to 40 m, IR Light Control, Smart IR ( Auto / Manual ) / OFF, IR Light Number: 2, Day/Night: Auto (ICR) / Color / BW, Backlight Compensation: WDR, BLC, HLC, White Balance: Auto/Tungsten/ Fluorescent/ Daylight/Shadow/Manual, Gain Control: 0-100%, Wide Dynamic Range: 120 dB, Noise Reduction: 2D / 3D DNR, Lens: : 2.8 mm Fixed Iris, F1.6, Angle Of View: H: H:88°°, V:47°, Privacy Masking: Off / On (4 Areas), Defog: Not supported, Local Storage: Micro SD (up to 256 GB), Alarm Inputs/Outputs: Not supported, Video Compression H.265 HEVC/H.264/MJPEG, Smart Codec, Resolution: 1st: 2304 x 1296 / 1920 x 1080 / 1280 x 720 2nd: 704 x 576 (PAL) / 704 x 480 (NTSC) / 640 x 480 / 352 x 288 (PAL) / 352 x 240 (NTSC) 3rd: 640 x 480 / 352 x 288 (PAL) / 352 x 240 (NTSC) / 320 x 240, Number of Video Streams: 3 (2 for encryption), Frame Rate*: MAX 30 fps, Bit Rate*: 100K ~ 6 Mbps, Audio Compression: Not supported, Audio Stream: Not supported, Audio Interface: Not supported, NETWORK: Ethernet: 10 Base-T/100 Base-TX Ethernet (RJ-45), Supported Web Browsers: Chrome / Edge, Supported OS: Microsoft Windows 10, Protocols**: IPv4, IPv6, TCP / IP, HTTP, HTTPS, RTSP / RTP / RTCP, IGMP / Multicast, SMTP, DHCP, NTP, DNS, QoS, SNMP, 802.1X, UDP, ICMP, ARP, TLS, Interoperability: ONVIF Profile G/S/T, Maximum Users Access: 10 Users, Security: User account and password protection, HTTPS, IP Filter, Digest authentication, TLS1.2 only, Stream encryption, AES128 / 256, SSH / Telnet closed, PCI-DSS compliance, EVENTS / ANALYTICS: Built-in Video: Analytics, Motion Detection, Tampering, Event Type: Video motion detection,Recording notification, Event Linkage: Event notification using Email and MicroSD card, Region Of Interest: 8, ELECTRICAL: Power Supply: DC12V, PoE (IEEE 802.3af) (Class 0), Power Consumption (Max): MAX 3.6 W, MECHANICAL: Dimensions: Ø110.0 mm × 85.6 mm (Ø4.33” × 3.37”), Dome Diameter Ø78.2 mm (3.08”), Product Weight 0.56 kg (1.23 lb), Package Weight 0.65 kg (1.43 lb), Body Material Die-cast aluminium housing, ENVIRONMENTAL: Operating Temperature: Starting Temperature:-40°C ~ 60°C (-40°F ~ 140°F), Working Temperature: -40°C ~ 60°C (-40°F ~ 140°F), Relative Humidity Less than 90 %, non-condensing, Ingress Protection IP67, Impact Resistance IK10, REGULATORY: Emissions: FCC PART 15, CE (EN 55032), Complies with RCM and UKCA, Immunity CE(EN 50130-4), Complies with RCM and UKCA, Safety: UL LISTED TO UL/CSA 62368-1, CE(EN 62368-1), Complies with RCM and UKCA, RoHs: CE(EN 63000).complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 505 | Supply, erection, testing & commissioning of NVR shall have 64 Channel video input. NVR shall be Embedded Linux. NVR shall support following bandwidth - 1280Mbps, Incoming 640Mbps & Outgoing 640Mbps. NVR shall support Video Output: 3 (1024*768, 1280*720, 1280*1024, 1440*900, 1920*1080, 1600*1200, 1920*1200, 3840*2160/7680*4320) HDMI; 1 (1024*768, 1280*720, 1280*1024, 1440*900, 1920*1080). Async out. NVR shall offer the following recording resolution streams Video Resolution: 12MP, 8MP, 5MP, 3MP, 2MP (1080P), 1.3MP (960P), 1.0MP (720P). NVR shall support Preview Capability: multiple matrix mode, Supported frame rate: 4K:240fps, 4MP:480fps, 2MP:960fps. NVR shall support schedule base snapshot, manual snapshot, event-based snapshot. NVR shall support Motion Detection. NVR shall support 4 zones Privacy Mask. NVR shall offer intelligent analysis functions powered including Human & Vehicle Detection, Perimeter Intrusion Detection, Line Crossing Detection, Stationary Object Detection, Crossing Counting, Heat Map, Crowd Density Detection, Rare Sound detection (gunshot/baby crying/dog barking), Face Detection. AUDIO. NVR shall support G.711A/G.711U Audio compression. NVR shall integrate Audio input 1 CH RCA port. NVR shall integrate Audio output 1 CH RCA port, HDMI audio. Video Recording and Playback. NVR shall support 1-30fps Video Frame Rate. NVR shall have Record Mode: schedule, event based- motion, I/O, PIR. NVR shall offer 16 CH max sync playback. NVR shall be able to playback according to different types, including Playback Mode Instant playback, Local video, local image. NVR shall support Record Search Time, calendar, channel search, and event search, (ANR, regular video, motion detection video, alarm video, intelligent detection video). NVR shall support following Video Playback: Start, stop, normal play, back play, frame by frame forward, full screen, Fast forward/backward (2x, 4x, 8x, 16x), Slow forward (1/2x, 1/4x, 1/8x, 1/16x), Add custom/ Default Tag, digital zoom, video clip, sub-stream/main-stream, playback video bar, scale of 30 mins to 24 hrs. NVR shall support following bandwidth - 1280Mbps, Incoming 640Mbps & Outgoing 640Mbps. NVR shall support 8 SATA, 1 x eSATA, HDD Capacity Single max. 18TB (enterprise class) & up to 12TB Surveillance HDD. NVR shall support RAID0, RAID1, RAID5, RAID6, RAID10. NVR Should have S.M.A.R.T info feature to check health of HDD, temperature and status. NVR shall offer Local, Network HDD NFS, SMB/CIFS. NVR shall offer USB mobile hard disk, U disk, network backup Method. NVR Should support FTP for uploading alarm video. NVR shall ANR Support Smart IPC (with SD card) ANR. Function. NVR shall support the following protocol: IPv4, IPv6, TCP/IP, HTTP, HTTPS, DDNS, RTMP, SMTP(SSL), SNMP, DHCP, PPPoE, UPnP, NTP, P2P, FTP, IP filter. NVR shall support ONVIF Profile S Support. NVR shall support ONVIF/RTSP/HTTP/HTTPS/RTMP port customized. NVR shall support Mobile Surveillance Support Apple, Android & Internet Explorer Support IE, Chrome, Firefox, Safari. NVR shall Digital Zoom support. NVR shall have IPC timing Manual/auto/timing/reconnect timing. NVR shall support the following Event Actions: pre and post recording, Send email, show message, send email, FTP upload video or screenshot, Cloud upload video or screenshot, full screen, voice prompts, Alarm output trigger, PTZ linkage. NVR makes axis, bosch, pelco, mountxross, sony support combination of different events for effective alarm trigger and response. NVR Shall have exception alarms on event type of no space on disk, disk error, video loss. NVR Shall be able to configure covert on camera by which recording is happening, but live view is restricted. Network Detection monitoring, Utilization of total and used bandwidth, IP filter with blacklist and whitelist. NVR Shall support video cover privacy mask both on live and recording up to 4 areas. NVR shall have User Management User add, delete, modify, permission management, support. NVR Shall be able to trigger PTZ presets on any camera AI event. NVR shall support Security Mode Authorized username and password, HTTPS with password, RTSP Validation. NVR should Manage IPC Support IPC centralized management, including IPC parameter configuration, information export and import, real-time information acquisition and upgrade. NVR shall have Statistics of events for face recognition, vehicle & human, cross count and heat map. Network Interface. NVR shall integrate 2 X RJ45 10M/100M/1000M adaptive Ethernet port. Alarm Input 16 CH alarm input & Alarm Output 4 CH alarm output. NVR shall integrate 1* RS485 , 1* RS232 & USB2.0*1(front), USB3.0*2(rear). General. The power consumption shall be AC 100-240 V, 250W & Power Consumption ≤8W (Without HDD). Operation Temp./ Humidity -10°C ~ 55°C/10%-90%. Certifications & Standards. NVR shall have the following Certifications. CE, FCC, BIS. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 506 | Supply, erection, testing & commissioning of Switches: 24 Ports 10/100/1000 Mbps PoE + 4 Ports 10G SFP+ Smart Managed Layer 2 Switch, Power budget 370W from day1, Support 802.3af/at), Switching Capacity 128 Gbps, MAC Address Table 16K, Packet Forwarding Rate, 95.24 Mpps, Flash Memory 64 MB, DRAM Size 256 MB DDR3, IGMP v1/v2/v3 Snooping & MLD snooping v1/v2, 802.3x Flow Control, HOL Blocking Prevention, LLDP/ LLDP-MED, 802.1D, 802.1W, 802.1s, 802.1Q, 802.1p QOS, SPQ, WRR, WDRR, Bandwidth Control, Static routing, IPv6 Neighbor Discovery (ND), ACL Max. 768 rules shared by IPv4, MAC, & IPv6, Traffic segmentation, ARP Spoofing Prevention, ARP Inspection, DHCP Snooping, MAC authentication, SSH v2, TLS v.1.2, DoS attack prevention, 802.1X Port-based Access Control, Port Security, RADIUS/TACACS+, MD5 authentication, GUI, Full CLI, Telnet Server, TFTP Client, MDI/MDIX, SNMP v1/v2c/v3. Internal/External 6 kV surge protection on all RJ-45 access ports, Operating Temperature -5 to 50°C, Storage Temperature -20 to 70°C, Operating Humidity 0% to 95% relative humidity, Certifiate: EMC EN 55032, Class A; EN 61000-3-2; EN 61000-3-3; EN 55024, Safety EN 62368-1, ROHS EN IEC 63000, 47 CFR FCC part 15: 2017, Subpart V, Class A, ICES-003, IEC 62368-1, IEC 60950-1, IEC 60950-1/AMD1, IEC 60950-1/AMD2, UL 62368-1 & CAN/CSA C22.2 No. 62368-1-14. MTCTE/TEC-ER (as notified vide Indian Telegraph (Amendment) Rules, 2017, OEM Should be ISO 45001, ISO 27001 & ISO 14001 Certified, OEM Should have Certificate for Industrial Cyber Security Capability (Like - IEC-62443-4-1:2018 or Equivalent) complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 507 | Supply, erection, testing & commissioning of Switches 8 x 10/100/1000 BASE-T PoE Ports, 2xSFP Ports & RJ-45 console port 802 3 at PoE + & 8023af PoE power 130W, IEEE 802 3i 10BASE-T Ethernet, IEEE 802 3u 100 BASE-TX Fast Ethernet, IEEE 802.3 ab, IEEE 802, 3az, IEEE 802.3xIEEE 802.3z, 20Gbps Switching capacity & packet forwarding rate 14Mbpps, 8K MAC address, DRAM Size DDR3 128MB, Flash memory size 32MB Fanless design, CPU Speed 500MHz. Packet Buffer size 4.1MBits Operating & storage Temperature -5 to 50degree C & -40 to 70 degree C operating & storage Humidity 10% to 90% & 5% to 90% Loopback detections IGMP snooping V, V2 & MLD Snooping V1/v2, IEEE 802 1AB LLDP & LLDP-MED IEEE 802 3az (EEE), 4K VLAN ID's Min 256 static VLAN, Multicast VLAB & Auto Voice & Video VLAN Port Mirriring 1x to one/Many to one, 802.1p Quality to service (QoS) SPW, WRR. Bandwidth control static.routing for inter-VLAN Communication Access control list (ACL) L2 & L3 ACL (IPv4 & IPv6) Broadcast/Multicast/unicast strorm control. traffic segmentation, TLS, DoS attack prevention, 802.1x Port based access control port security, ARP spoofing prevention DHCP server screening IP-MAC Port bonding ARP inspection DHCP snooping 802.1x Authentication local/RADIUS database (IPv4 & IPv6 port based access control EAP, OTP, TLS, TTLS, PEAP & Support MD5 authentication, feature cables diagnostics IPv4 & ipv6 inspection, SSH v2 feature, 802.3x flow control & HOL blocking prevention management thru web-based & CLI, SNMP v1/v2c/v3, NTP/SNTP, Ipv4/v6 dual stack, dual image dual configuration product should approved from TEC under mandaotory testing & certification of Telecom Equipment as notified vide indian Telegraph (Amendment) Rules 2017 CE FCC, UL, IEC/EN 60950 & IPv6 Ready compliance. OEM Certification for ISO 45001, ISO 9001, ISO 14001 & ISO 14064-1 IEC 62443-4-1 Complete in all respects as approved and desired by the Engineer-in-Charge at site. |
| 508 | Supply, erection, testing & commissioning of HDD Formatted capacity 6 TB surveillance ,Data transfer rate (max) Buffer to host Host to/from drive (sustained) 6 Gb/s 171 MB/s,Cache (MB) 64,Rotational speed (RPM) IntelliPower ,Load/unload cycles4 300,000,Non-recoverable read errors per bits read <1 in 1014, Operating (2 ms, read/write) 30, Operating (2 ms, read)65, Non-operating (2 ms)250, Average power requirements (W) Read/Write 5.90,Idle 4.90,Standby and Sleep 0.40 complete in all respects as approved and desired by the Engineer in-charge at site. |
| 509 | Supply, erection, testing & commissioning of Display : 50 inch, 4K (3,840 x 2,160), Direct LED, Professional Display with 4K Processor, Native Contrast ratio 5,000:1 or higher, Response time 12 ms or lower, Brightness 400 cd/m² or higher, 24/7, Portrait/Tilt functionality, HDMI Auto wake up, HTML5 platform, 16GB On Board Storage, HDMI*4 with HDCP 2.3 / RS232 / USB / RJ45 / Wi-Fi Direct / 20W Speakers / Android OS or similar, Viewing angle 178 degree, Apple AirPlay & Chromecast. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 510 | Supply, Installation, Testing & Commissioning of 6 Mtr HDMI Cable for NVR, UL Listed complete in all respects as approved and desired by the Engineer in-charge at site. |
| 511 | Supply, Installation, Testing & Commissioning of 1 KVA UPS with Input power factor - 0.99, Output power factor - 0.8, OVCD inbuilt , DC V 36v, Efficiency : Above 90% complete in all respects as approved and desired by the Engineer in-charge at site. |
| 512 | Supply, Installation, Testing and Commissioning of Wall Mount 15U x 600 W x 600 D , Front Glass Door (tinted, Toughened) with Lock & Key, 2 pairs of 19\\" Mounting Rails with U-Marking , Welded Side Walls, Min Accessories : 1U Cable Manager (1), Hardware Packet (1 Pkt), 6 Socket 5 Amp. Power Distribution Unit (1 No), Roof Mounted Fan Unit / 90 CFM /230V AC. as per DIN 41494 Standards. complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 513 | Providing Fire Detection/ Emergency Evacuation & PA System: |
| 514 | FIRE PANELS & ANNUNCIATORS: |
| 515 | Supply, installation, testing & Commissioning of Microprocessor based Multi-loop, True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event , 1000 alarm log history events, QWERTY keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 300 analog addressable devices. The panel shall work in degrade mode in case of CPU failure, Products not having this feature will offer Redundant CPU. Four access levels, flash EPROM, Panel should be capable to work 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. The panel shall support with Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on same peer-to-peer Network and 2 ways Communication Fire Fighters System capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation. The Fire Fighters Telephone System shall be capable of having minimum 30 Telephones in conference in multiple FFT Risers. The panel shall be capable of self programing without any dependancy on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for progamming the panel with all necessary licence. Panel shall have Modbus/ Bacnet over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. UL & FM Approved make notifier,xls 3000 ,bosch UL, johnson control ( IFC Series) nohmi shall be capable for remote accessibility on a mobile app through cloud platform/solution. Designed to meet UL864, 10th edition. The panel should be expandable up to 10 loops from the outset for future expansion and also capable of supporting a WiFi gateway and detectors in the active loop. The contractor is required to submit the OEM MAF signed and stamped by an authorized signatory. Additionally, the contractor must provide a completed BOQ, duly signed and stamped by the OEM's authorized signatory. The OEM should offer service support, either directly or via its authorized direct channel partner, within the state of Punjab. Furthermore, the contractor must submit the test certificates for all BOQ items, signed and stamped by the OEM complete in all respects as approved and desired by the Engineer in-charge at site. |
| 516 | Supply, installation, testing & Commissioning of chassis (Small size) for Amplifier and Digital Series Distribution Board. Chassis should be fabricated from 14-gauge steel, e key-locked door is provided with a pin-type hinge, two keys and the necessary hardware to mount the door, Right- or left-hand hinges, selectable in the field. Door opens 180°, door should be heat dissipation refers to the process of transferring heat away from a system, component, or device to maintain its temperature within acceptable limits. Complete in all respects as approved and desired by the Engineer in-charge at site. |
| 517 | Supply, installation, testing & Commissioning of Loop Cards Class A Wiring with min. supporting cable length Up to 1.2 Km UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site. |
| 518 | Supply, installation, testing & Commissioning of Digital Voice Command Controlling Board combines the capabilities of a powerful digital audio processor, an eventdriven audio message generator, and a router.The DVC has two wire digital audio ports to connect to wire DAL segments. The DVC may be networked Programmable from NUP port. Up to 32 minutes of standard quality or 4 minutes of high quality digital audio storage of user-selected/created messages and tones. Supports twisted-pair wire media. Supports single- and multi-mode fiber-optic media when used with fiber option modules. 4-channel analog audio supported.The DVC Should be Compatible with Auxiliary input for line level, 1.0 VRMS, or 1.41 Vp-p low level audio. Selectable AGC, user control of audio level, and audio supervision are supported. UL Listed: S635.ULC Listed: S635.FM Approved.Complete in all respects as approved and desired by the Engineer in-charge at site. |
| 519 | Supply, installation, testing & Commissioning of Digital Voice Command Keyboard/ Touch Screen for local annunciation and controls; status LEDs and 24 user-programmable buttons.Display All Call, Page Active Evac Areas, Page Active Alert Areas, Page Inactive Areas UL Listed . The solution should be from single OEM. Complete in all respects as approved and desired by the Engineer in-charge at site. |
| 520 | Supply, installation, testing & Commissioning of Paging Microphone compatible with Emergency evacuation Control Panel Project specific OEM authorization required for executing agency complete in all respects as approved and desired by the Engineer in-charge at site. |
| 521 | Supply, installation, testing & Commissioning of Addressable Smoke photo-Thermal Detector and base with sensitivity range of 0.5 to 4.0% obs/ft.The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches. Designed to meet UL268, 7th EditionThe solution should be from single OEM. OEM should have manufacturing facility in India. The contractor is required to submit the OEM MAF signed and stamped by an authorized signatory. Additionally, the contractor must provide a completed BOQ, duly signed and stamped by the OEM's authorized signatory. The OEM should offer service support, either directly or via its authorized direct channel partner, within the state of Punjab. Furthermore, the contractor must submit the test certificates for all BOQ items, signed and stamped by the OEM complete in all respects as approved and desired by the Engineer in-charge at site. |
| 522 | Supply, installation, testing & Commissioning of Addressable Rate of Rise Heat Detector rated at 8.3 deg C/min.NFPA 72. The detector shall have bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary/ Electronic decimal switches.UL & FM Approved The solution should be from single OEM. Complete in all respects as approved and desired by the Engineer in-charge at site. |
| 523 | Supply, installation, testing & Commissioning of Addressable Manual Call Point (Pull down / Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device complete in all respects as approved and desired by the Engineer in-charge at site.UL & FM Approved IComplete in all respects as approved and desired by the Engineer in-charge at site. |
| 524 | Supply, installation, testing & Commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and Min.110 cd flashintg at 1 Hz for visual indication. UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site. |
| 525 | Supply, installation, testing & Commissioning of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes/ Telephone Jack. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary / Electronic decimal switches UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site. |
| 526 | Supply, installation, testing & Commissioning of Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary/ Electronic decimal switches UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site. |
| 527 | Supply, installation, testing & Commissioning of Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device.UL & FM Approved Module shall be supplied with mounting plate from OEM for ease of installation & maintenance complete in all respects as approved and desired by the Engineer in-charge at site. |
| 528 | Supply, installation, testing & Commissioning of Fire Fighter's Telephone Handset for two way communication between Remote Fire Fighter & Fire Command Center UL Listed complete in all respects as approved and desired by the Engineer in-charge at site. |
| 529 | Supply, installation, testing & Commissioning of Addressable Fire Fighter's Telephone Jack for two way communication between Remote Fire Fighter & Fire Command Center UL Listed complete in all respects as approved and desired by the Engineer in-charge at site |
| 530 | Supply, installation, testing & Commissioning of Chassis assembly enclousre for Fire fighter telehphone handset, UL Listed complete in all respects as approved and desired by the Engineer in-charge at site. |
| 531 | Supply,installation, testing & Commissioning of Digital Audio Amplifier with transfarmer as per site requierment . Amplifier shall be capable of N:N/N:1 configuration and shall be dual channel capable of processing Two of 8 audio channels and a total of Min 95 W ( It may be 1 unit or Combination of Multiple units to achieve the Requirement) at 70.7 VRMS output along with necessary enclosures with local FFT Raiser. The Digital Audio Amplifier shall be fully monitored for fault and alarm reporting. The proposed Digital Audio Amplifiers shall be (Wall/Panel Mounted). Integrated 8 channel Digital Voice Evacuation System Controller (as per requierment) capable of broadcasting Evacuation Messages on the same peer-to-peer Network and 2 ways Communication capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC/Amplifier operation. Products not having this feature must provide dedicated CPU for DVC. The Evacuation System Controller shall have FFT Risers to control and conference minimum 30 Telephones.. Amplifiers shall be distributed across the building/floor to manage the sound attenuation problem & for the best sound intelligibility. All amplifiers can be back up of minimum 5 hours using secondary power source(battery power/UPS power) complete in all respects as approved and desired by the Engineer in-charge at site. |
| 532 | Supply, installation, testing & Commissioning of 2W Multi-Tap (0.25W; 0.5W; 1W; 2W), Ceiling/Wall Mount Speakers. The speakers shall be of the same make as that of the Control Panel & Amplifiers. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms. UL Listed. Project specific OEM authorization required for executing agency complete in all respects as approved and desired by the Engineer in-charge at site. |
| 533 | Supply, installation, testing & Commissioning of Back box for speaker as per site requirement complete in all respects as approved and desired by the Engineer in-charge at site. |
| 534 | Supply, installation, testing & Commissioning of fire resistance cable (Colour Red) (at 950° C for 180 minutes) of BS6387/BS7846 Fire Proof Cable, 2C X 1.5 sqmm, BS6387 & BS7846, annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, low smoke & zero halogen (LSZH) bedding, galvanized steel wire armour, low smoke & zero halogen (LSZH) red outer sheath. 600/1000 volts. Fire resistant to IEC 331 & BS7846 F2/BS6387 & CWZ. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332-3) complete in all respects as approved and desired by the Engineer in-charge at site. |
| 535 | Supply, installation, testing & Commissioning of Exit LED M ST LED LED based exit sign with dimming function, Reading distance, exit sign Two-sided 25m, Voltage 220-240VAC / 50-60Hz, Power consumption 3.3W / 3.5VA, Battery 3.6V/1.2Ah NiMH, Battery protection Over charge protection /deep discharge protection, Charging Time 16 hours, Battery back-up time 1 hour / 3 hours / 8 hours (from dip switch), Light source 15 LED, Approvals EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, Ambient temperature 5 to 40 °C, Humidity Up to 95%, IK rating IK09, IP rating IP40, Dimensions 265 x 53 x 222 mm, Weight 540 / 742 gr , Colour Anodized aluminum / black plastic, Materials Aluminum, Acrylic Plate, Mounting method Ceiling, wall bracket, suspended, pendulum, flag mount, Delivered as self-contained/auto test luminaire Choice of 1, 3 or 8 hour autonomy via DIP switch IP 40 – dustproof luminaire Reading distance upto 25 meters.High lumen output – 1h = 180lm / 3h = 110lm /8h = 40lm Technical lifetime of LED > 100 000 hours , 4 Pictograms (left, right, down, up) are included in the luminaire ordering part code complete in all respects as approved and desired by the Engineer in-charge at site. |
| 536 | Supply, installation, testing & Commissioning of Agora LED NM LED IP65 230V 2X6W 1h/3h/8h. The luminiare comes in plastic housing. Mounting bracket is not required for this luminaire, IP65/NA 0 Non -Maintained Self Testing 12V / 7Ah Pb, LED based for anti-panic area, surface assembly Delivered as self-contained/auto test luminaire Choice of 1, 3 or 8 hour autonomy via DIP switch High lumen output – 1h = 360lm / 3h = 170lm / 8h = 70lm Simple and quick assembly and maintenance Technical lifetime of LED > 100 000 hours • IP65 – dust and waterproof luminaire, Voltage 220-240VAC / 50-60Hz Power consumption 11.4W / 11.8VA Battery 12V / 7Ah Pb Battery protection Over charge protection /deep discharge protection Charging Time 23 hours, Battery back-up time 1 hour / 3 hours / 8 hours (from dip switch), Light source LED 2x6, Technical lifetime (light source) >100 000 hours, Lumen output, emergency (1h / 3h / 8h) 3200 / 1600 / 800 lm, Approvals EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, Ambient temperature 5 to 40 °C, Humidity Up to 95%, IP rating IP65, Dimensions 302 x 94 x 210 mm, Weight 4200 / 4420 gr, Materials PC/ABS, PC, Aluminium, Mounting method Wall mounting, Make : Honeywell, Siemens / RP / Olampia / Adward.The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 537 | Supply, installation, testing & Commissioning of Online UPS 1 kva 800 Watts Tower UPS with 1 hour battery backup. Operating Temperature Range 0 to 40 Degree @ 100% Load @ 50 Degree with 50% Load,Storage Temperature -15°C~60°C, Relative Humidity 0-95% No condensates, Acoustic Noise 40 dBA @ 1 Meter, Cooling Forced air cooling by the internal fans, Input Socket IEC C13, Output Socket IEC C14, No of output sockets 3 No's, Rated Input Voltage 208/220/230/240 Vac, Maximum working input voltage range 160 to 300 Vac @ 100% Load, 100 to 300 Vac @ 50% Load, Input Power Factor 0.99, Input THDi% 5%, Generator Set Yes 1.5 x UPS Capacity, Rated kVA 1000 VA, Rated kW 800 Watts, Load type Resistive load/ lagging load/ non-linear load/ transformer load/ lighting load, Load power factor range 0.5~1 lagging, Load Crest Ratio 3:1, Online Efficiency 88%, Rated Battery Voltage 36 Vdc, Battery Type VRLA (Valve Regulated Lead Acid Battery), 12VDC, Battery backup Back UP : 936VAH, Maximum charging current 10 Amps, ECO Mode Available, Communication (Independent SCI) Available, Intelligent Card slot (Independent SCI) Available, OVCD Available, EPO Function Available, Intelligent Fans Speed control Available, Auto restart function Available, Cold start Available complete in all respects as approved and desired by the Engineer in-charge at site. |
| 538 | PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 539 | Overall size 1.5sq.mm (48/0.20mm), 2Core |
| 540 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 541 | Heavy gauge welded conduit pipe 25mm dia. (ISI marked 1.60mm thick) Flushed |
| 542 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 543 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 544 | Providing 160KVA Silent Diesel Generating Set: |
| 545 | Supply, Erection, Testing and Commissioning of Silent (Sound Proof) Diesel Generator Set 160KVA /128KW with Manual Control Panel .It should be air cooled/water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard).ENGINE: The Diesel engine developing 199 BHP (Approx.) for giving a power rating as per ISO 8528- Part-1 ( With CPCB-IV Norms as amended upto date) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements.ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication and MCCB (Fixed Thermal and Adjustable Thermal protection) of suitable rating for outgoing supply. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use. |
| 546 | ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be IP54 Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.with 2 year warranty from the date of installation. complete in all respect as desired by engineer at site:-The Generator set should be instaaled at site on the suitable size existing plinth of RCC as per specifacation DG set as per satisfacation of the Engineer- in-Charge at site. The model of engine will be decided by the Engineer in Charge. MANUAL CONTROL PANEL: Manual control panel shall be fabricated out of 1.6 mm sheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-53 degree of protection & front operated, composite meter for digital display, HRC fuses of suitable rating. MCCB (Fixed Thermal and Adjustable Thermal protection)/ ACB (Over cuurent/ overload, shorcircuit, instantenous, earth fault protection) should be used. Battery charger complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternator or dynamo fitted on the engine.All the components in the control panel shall be properly mounted, duly wired and labeled. Suitable terminals are to be provided for panel incoming and outgoing connections. System opeartion facility provided shall afford the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequency meter,battery charger complete in all respect as desired by engineer at site:- |
| 547 | INDOOR LT CABLES, CABLE TRAY & DWC PIPE: |
| 548 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 549 | Overall size 185sq.mm (3½ Core) Un-armoured (Loose) 1Run from DG Set 160KVA to Sub LT Panel (Emergency) |
| 550 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 551 | Double walled corrugated (DWC) HDPE pipe120/103.50mm (outer/ inner dia.) |
| 552 | COPPER EARTHING |
| 553 | COPPER EARTHING (Upto 14 metre in Length):-iii- Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- (Body earthing & Neutral Earthing) |
| 554 | Earthing with 25mm x 3mm Copper Tape (upto 14Metre in Length) (Body earthing & Neutral Earthing: 4Nos. for DG Set 160KVA) |
| 555 | Additional Length 25mm x 3mm thick Copper Tape |
| 556 | Providing 11 KV, 400kVA Sub Station: |
| 557 | VACUUM CIRCUIT BREAKER: |
| 558 | Supply, Erection, Testing and Commisioning of 11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type VCB (Vacuum Circuit Breaker) switch board unit 630 Amp. which includes 630/800 Amp. Vacuum Circuit Breaker for Incoming/ Out going feeder with Electrolytic Copper bus bars of suitable rating, Horizontal Isolation type as per IEC 62271-100-200. The Switchgear panels shall be sheet steel construction with ALUZINC not less than 2.5mm thickness for load bearing sections and not less than 2mm thickness for non-load bearing, dust, moisture and vermin proof to provide a degree of protection IP-4X in accordance with IS:13947. VCBs are type tested according to International Standards IEC-62271 at renowned laboratories. They are compact, safe and reliable. The Panels shall be tested for IAC level of 25kA/1 Sec. No. of operations of Vacuum interrupter bottles for better performance (i) At rated current: 10,000 operation (ii) No. of short circuit dead operation at rated short circuit current: 100 opeartion |
| 559 | VCB parameters are as below: (a). Rated Voltage: 12kV(b). Rated short circuit breaking current withstand : Min. 25kA for 3sec.(c). Rated insulation voltage lightning (Impulse withstand) : At 75kV Peak(d). Rated insulation voltage( Power frequency withstand) : Min. 28kV(e). Rated operating sequence : O-0.3 sec - CO - 3 min-CO(f). Spring charging mechanism : Manually as well as motor operated (230V, AC, 50Hz)(g). Operation type: Manually and electrically open (Electrical-230V, AC,50Hz) (h). Earthing Switch : Mechanically interlocked device to prevent personnel from getting electric shock during breaker maintenance. VCB incorporating mechanical as well as electrical ON/OFF indiaction \\"OFF\\" push button, test/ serviceposition limit switches, with minimum 6NO+6NC breaker auxiliary contacts in service position, Manual charging of breaker should be done without opening the front door. |
| 560 | Incomer shall consist of:(a). Cast Resin CT's 11kV : 600-300/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA(b). Cast Resin PT's 11kV : PT Ratio 11kV/√3 / 110V/√3 / 110V/√3, Class 1, Class 0.5 Burden 50VA(c). Protections : Numerical instantaneous IDMTL mimic dispaly relay (230V, AC, 50Hz) : U/V, O/V, E/F, O/C, S/C & TCS with RS 485 Modbus protocol for communication & drawout type(d). Master Trip/ Anti pumping relay(e). Digital Voltmeter : Range 0-12kV with necessary voltmeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal.(f). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal.(g). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard(h). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operationsAll the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments. |
| 561 | Outgoing shall consist of:(a). Cast Resin CT's 11kV : 600-300/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA (b). Protections : Numerical instantaneous IDMTL mimic dispaly relay : E/F, O/C, S/C & TCS with RS485 Modbus protocol for communication & drawout type for line feeder protection(c). Master Trip/ Anti pumping relay(d). Transformer Protection : 3 elements auxiliary relay (230V, AC, 50Hz) for transformer fault, Alarm for Buchholz, winding temperature & oil temperature (e). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 110V AC 96x96 sq.mm dial with shroded terminal(f). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard(g). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operationsAll the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments:- |
| 562 | 11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type VCB (Vacuum Circuit Breaker) Switch board unit 630 Amp. which includes 1 No. 630 /800Amp. Vacuum Circuit Breaker as Incomer, 2Nos. Vacuum Circuit Breaker as Out going feeder with in built power packs interconnected with Electrolytic Copper bus bars of suitable rating (2Nos. 800 KVA Transformer). |
| 563 | TRANSFORMER 400KVA: (1No. for Building Electrical Load) |
| 564 | Supply, installation, testing and commissioning of 11KV/433V, 400KVA, Indoor/Outdoor type floor mounted Distribution Transformer, Three Phase 50 Hz, Oil Immersed, Naturally Cooled ONAN, Core type Double wound with copper conductor conforming to IS:1180 (As amended upto date) Level-2 & IS: 2026 with first filling of Oil as per IS:335 compltete with connections on both sides (HT/LT side) as per satisfaction of Engineer Incharge at site. (a). Output Rating : KVA (b). No Load Voltage ratio at rated voltage & frequency: 11KV/ 0.433kV(c). Off Circuit Tap changer: +5% to -10% off circuit tapping in steps of 2.5%. (d). Vector group : Dyn11 (e). Ambient temperature: 50°C(f). Oil/ Winding temperature rise: As per IS:1180(g). Magnetic Core: Prime grade of M4 or better (h). System Highest Voltage :- 12kV at the HV side (i). Terminations: Cable Box on HV & LV Side(j). Insulation Level: ● H.V. Power Frequency (KV rms) : 28 kV ● H.V. Impulse withstand voltage (KV peak): 75 kVpThe Tranformers shall fitted with accesories like Rating and Diagram anodized aluminium plate, 2 Nos. Earthing terminals, 4 Nos. Lifting Lugs, Air Release hole with plug, Dehydrating Silica Gel Breather, Oil Level guage with minimum level marking, Conservator with Oil filling hole with cap & drain plug, Thermometer Pocket, Jacking Lugs, Bottom Drain cum filter valve, Top Filter Valve, 4Nos. Uni-directional rollers, Explosion vent with diaphragm, Marshmalling Box (Protection Class IP55), OTI with alarm & trip, WTI with alarm & trip, Double float Buchholz relay with alarm & trip, 2Nos. Shunt off valves for Buchholz relay & Fixed/ Detachable Radiator. Note: Manufacturer testing labotatory to be NABL certified with in house core cutting facility for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer designed for 110% continuous overfluxing withstand capability as per IS:6600. Noise Level for Transformer shall be as per NEMA TR1-2013. All Routine Test shall be carried out as per IS: 2026:- |
| 565 | APFC FOR 400KVA TRANSFORMER: |
| 566 | Design, supply, installation, testing and commissioning of APFC Panel of 120 KVAR capacity with 7% detuned reactor suitable for operation on 415 ± 5% Volt, 3 Phase, 50 Hz, Ac supply, having MPP type resin bounded static capacitors (without oil) of suitable rating complete with MCCB Four Pole 250amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting (Ics = 100%) capacity panel, upto 12 step microprocessor based power factor controller relay capable to select the rating from 4Nos. x 10KVAR, 2Nos. x 15KVAR, 2Nos. x 25KVAR capcitor bank, current limiting contactors for each capacitors protected with suitable rating MCCBs of minimum 25 KA breaking capacity having thermal magnetic release for over load & short circuit protection, cooling fans for panel and digital multifunction meter, Class-1.0 with RS485 communication port indicating lights, earthing the panel etc. as reqd. The panel should have provision of timer based circuit in APFC relay to switch ON and OFF the static part of 120 KVAR capacity, automatically as and when required. Capacity of static capacitor should be accommodated from the overall rating of the panel and should be designed to switch in independently. The panel should be manufactured with1.6 mm thick CRCA sheet duly powder coated etc complete as per PWD specification complete as per satisfaction of the Engineer in charge at site. |
| 567 | INDOOR LT PANELS : |
| 568 | LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS):Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).Fabrication: Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.Painting: The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . |
| 569 | Busbars: The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. Metering: The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of MCCB's to be installed in the cubical panel Enclosure (Excluding the cost of MCCB's) as per following:- |
| 570 | MAIN LT PANELS : |
| 571 | LT Panel enclosure having space for 1No. Incomer MCCB 630Amp. and 6Nos. outgoing MCCB's 40amp. to 250amp. (Option: MCCB 200-250amp.= 2Nos. and MCCB's 40-100amp.= 4Nos.) according to the requirement at site (Approx. size 1475 x 1800 x 400mm) (DETAIL SEE IN PANEL INVENTORY) |
| 572 | SUB LT PANEL (NORMAL): |
| 573 | LT Panel enclosure having space for 1No. Incomer MCCB 400Amp. and 4Nos. outgoing MCCB's 100amp. to 160amp. according to the requirement at site (Approx. size 2025 x 1100 x 400mm) (DETAIL SEE IN PANEL INVENTORY) |
| 574 | SUB LT PANEL (EMERGENCY): |
| 575 | LT Panel enclosure having space for 1No. Incomer MCCB 400Amp. and 4Nos. outgoing MCCB's 100amp. to 160amp. according to the requirement at site (Approx. size 2025 x 1100 x 400mm) (DETAIL SEE IN PANEL INVENTORY) |
| 576 | MCCB's (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc |
| 577 | MCCB Four Pole 63amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 578 | MCCB Four Pole 160amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 579 | MCCB Four Pole 200amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 580 | MCCB Four Pole 250amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting |
| 581 | MCCB Four Pole 400amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting |
| 582 | MCCB Four Pole 630amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting |
| 583 | ON LOAD CHANGEOVER SWITCH (Without Sheet Enclosure):Supply and erection of On Load Change over Switch with advance neutral UNIT (Panel mounting Cubical type) in the existing Cubical Panel Confirms to IS 13947 (Part-3) complete with G.I. Bolts, Nuts & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:- |
| 584 | On Load Change Over Switch Four Pole 400amp., 415volts |
| 585 | HT CABLE, END TERMINATION KITS & CONTROL CABLE FOR TRANSFOMER: |
| 586 | XLPE INSULATED HT ARMOURED CABLES (UNDERGROUND):Supply & laying of Circular Aluminium Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011 working voltage 11KV(E) grade to be laid 1.50 meter below ground level including excavation, sand cushioning, covering with sand & First class bricks and back filling the trench etc., of the required size:- |
| 587 | HT Cable Overall size 150sq.mm (3Core) From PSPCL Meter toSubstation Room Main VCB and Main VCB to 1No. 400KVA Transformer & 1No. Existing VCB) |
| 588 | XLPE INSULATED HT ARMOURED CABLES (LOOSE):Supply & laying of Circular Aluminium Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011 working voltage 11KV(E) grade to be laid 1.50 meter below ground level including excavation, sand cushioning, covering with sand & First class bricks and back filling the trench etc., of the required size:- (From Metering Room to VCB & VCB to 2Nos. Transformers in Substation Room) |
| 589 | HT Cable Overall size 70sq.mm (3Core) (From Substation Room Main VCB to 1No. 400KVA Transformer) |
| 590 | HT Cable Overall size 150sq.mm (3Core) |
| 591 | S/E of Heat shrinkable cable end termination/ Straight through joint kit for 11 KVA /6.6 KV (E) XLPE Cables as approved & desired by Enginer in charge:- |
| 592 | Heat Shrinkable End Termination for cable size 50-95 sq. mm, 3Core (Indoor Type) |
| 593 | Heat Shrinkable End Termination for cable size 120-185 sq. mm, 3Core (Indoor Type) |
| 594 | Heat Shrinkable End Termination for cable size 120-185 sq. mm, 3Core (Outdoor Type) |
| 595 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of XLPE/ PVC insulated PVC sheathed (10 core) unarmoured copper conductor cable (ISI marked) confirm to IS:7098 (PART-I), 1988 loose in the existing trench or pipe with suitable size of copper thimbles/ lugs complete in all respect as desired by the Engineer-in-charge:- (From Substation VCB to 2Nos. Transformers 400KVA) |
| 596 | Overall size 2.5sq.mm (10 Core) |
| 597 | INDOOR LT CABLES, CABLE TRAY & DWC PIPE: |
| 598 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 599 | Overall size 150sq.mm (3½ Core) Un-armoured (Loose) |
| 600 | Overall size 240sq.mm (3½ Core) Un-armoured (Loose) |
| 601 | Overall size 400sq.mm (3½ Core) Un-armoured (Loose) |
| 602 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 603 | Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.) |
| 604 | Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.) |
| 605 | Double walled corrugated (DWC) HDPE pipe120/103.50mm (outer/ inner dia.) |
| 606 | Double Walled Corrugated HDPE Pipe 180/152mm (Outer/ Inner dia.) |
| 607 | CABLE TRAY:Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 608 | Cable Tray Size 300mm x 50mm x 50mm (2mm thick) |
| 609 | S/E of LT Cast Resin type/ Heat Shrinkable Termination Kit for Outdoor/ Indoor supply of 1.1 KV grade PVC/XLPE cable as desired by the Engineer in charge of the site:- |
| 610 | Heat Shrinkable Outdoor/ Indoor End Termination Kit for Cable Size 3½/4 Core 400-630sq.mm |
| 611 | Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:- |
| 612 | Brass Gland for Aluminium cable 3/3½/4 Core size 150sq.mm |
| 613 | Brass Gland for Aluminium cable 3/3½/4 Core size 240sq.mm |
| 614 | Brass Gland for Aluminium cable 3/3½/4 Core size 400sq.mm |
| 615 | Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- |
| 616 | Aluminium thimble cable Core size 10 -16sq.mm |
| 617 | Aluminium thimble cable Core size 70sq.mm |
| 618 | Aluminium thimble cable Core size 120sq.mm |
| 619 | Aluminium thimble cable Core size 150sq.mm |
| 620 | Aluminium thimble cable Core size 240sq.mm |
| 621 | Aluminium thimble cable Core size 400sq.mm |
| 622 | COPPER EARTHING |
| 623 | COPPER EARTHING (Upto 14 metre in Length):-iii- Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 624 | Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length) |
| 625 | Earthing with 25mm x 3mm Copper Tape (upto 14Metre in Length) |
| 626 | COPPER EARTHING (Upto 23 metre in Length):Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 19.50 metre (63.96 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 23metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 18metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 627 | Earthing with 40mm x 5mm Copper Tape (upto 23Metre in Length) |
| 628 | Additional Length 20mm x 3mm thick Copper Tape |
| 629 | Additional Length 25mm x 3mm thick Copper Tape |
| 630 | Additional Length 40mm x 5mm thick Copper Tape |
| 631 | SUB STATION SAFETY EQUIPMENTS: |
| 632 | Supply of Rubber hand gloves suitable for 11KV. |
| 633 | Supply & fixing of shock treatment chart both in Hindi & English for treating person suffering due to electric shock mounted on wall hooks. |
| 634 | Providing and fixing H.T. danger notice plate of 250 mm x 200mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required. |
| 635 | Providing and fixing M.V. danger notice plate of 200 mm x 150mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required. |
| 636 | Providing of set of 4 Nos. 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red - oxide paint and written with white paint 'Fire' and mounted on MS angle iron frame with bracket of appropriate size and capacity including filling sand etc. |
| 637 | Supply of First Aid box as approved by St. John Ambulance Brigade / Indian red Cross conforming to IS 2217 -1963. |
| 638 | Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat 1Mt. x 2Mt. of 2.0 mm thick +/- 10% confirming to BIS: DOC NO. ET-02 (5440) meeting requirments of IS: 15652 :2006 (with upto date amendment), suitable for all voltages not exceeding 3.3 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at size as per site requirments. |
| 639 | Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat 1Mt. x 2Mt. of minimum 3.0 mm thick +/- 10% confirming to BIS: DOC NO. ET-02 (5440) meeting requirments of IS: 15652 :2006 (with upto date amendment),, suitable for all voltages not exceeding 33 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at size as per site requirments. |
| 640 | Providing and fixing of 4.5 Kg. Capacity FIRE EXTINGUISHER,CO2 type as per IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect |
| 641 | Providing and fixing of 6 Kg. Capacity FIRE EXTINGUISHER, ABC Powder type (stored pressure) asper IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect |
| 642 | Providing Flood Lighting: |
| 643 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 644 | Overall size 1.5sq.mm (Un-sheathed) |
| 645 | XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- (For Flood Lights) |
| 646 | Overall size 10sq.mm (3Core) Un-armoured (On-Surface) |
| 647 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 648 | Double walled corrugated (DWC) HDPE pipe 63/51mm (outer/ inner dia.) |
| 649 | SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES: |
| 650 | Supply and erection of M.S. Channel bracket made from 100mm x 50mm of length 600mm and height 600mm with M.S. angle iron 40mm x 40mm x 5mm for installing metal halide flood light fitting on it. Bracket should be fixed/ welded with the existing pipe of cover shed. The bracket should be painted with one coat of primer and two coats of approved paint. (For Flood Lights on Parapet wall) |
| 651 | Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:- |
| 652 | SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 200mm x 140mm x 95mm with hinged water tight cover with locking arrangement (For Flood Lights on Parapet wall). |
| 653 | GALVANIZED IRON PIPES AND G.I. EARTHING:Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling).(For Cubical Pedestal) |
| 654 | Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length) |
| 655 | Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (On Surface) |
| 656 | Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:- |
| 657 | Brass Gland for Aluminium cable 2/3/4 Core size 10sq.mm |
| 658 | Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- |
| 659 | Aluminium thimble cable Core size 10 -16sq.mm |
| 660 | SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES:CUBICAL PEDESTAL: Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4\\" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:- |
| 661 | Cubical Size 1200mm high, 900mm wide and 350mm deep with platform dimensions 1000mm x 450mm x 450mm |
| 662 | MS SHEET ENCLOSURE FOR MCCB's:Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- |
| 663 | MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm) |
| 664 | MCCB's (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 665 | MCCB Four Pole 63amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 666 | TIMER:- Supply and erection of Switch S/E of Microprocessor Based Street Light Controller with digital time switch daily programmed with stand by lithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO, MCB 2 pole 40amp. (C-Curve, 10kA) & power wiring with single core PVC insulated FR cable 10 sq. mm and control wiring with PVC insulated FR cable 1 sq. mm, 1 no. two position selector switch to bypass timer and other accessories & petty material (din rail, 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) should be fixed on bakelite sheet 6mm thick to be mounted in a IP54 surface/ flush mounting powder coated sheet metal (1.60mm thick) cabinet having size 450mm x 600mm x 150mm to switch ‘ON’ all the 3 phases & switch ‘OFF’ 3 phases pre-fixed timings complete in all respect as per satisfaction of Engineer-in-charge:- |
| 667 | Street Light Controller (For Single Phase Circuit) with 1 No. Three Pole Power Contactor 40A, 1 No. MCB 2 Pole 40amp. (C-Curve,10kA) & petty material (Din rail, 1 No. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) |
| 668 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 669 | MCB Single Pole 0.5-4amp. (10kA, Curve-C) |
| 670 | Supply and erection of LED Flood Light 120 watt, AC supply voltage 140-270 volts, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No: AT/2021/GL/1410-1422 Dated: 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 671 | Supply and erection of LED Post top 40/45 watt Opal Diffuser Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 672 | Providing Solar Power Generation System: |
| 673 | Grid interactive PV System Solar Power Plant of 57KWp: |
| 674 | Supply, Installation, testing & Commissioing of Grid interactive PV System Solar Power Plant (i.e connected to utility grid) of Minimumcapacity including required quantities of SPV modules (High power density Monocrytalline based single module of capacity +400 watt) formed into arrays, their mounting arrangement, Power conditioning units (i.e String Solar Inverter with 2Nos. GI Chemical earthing with suitable size GI strip upto string inverter and AC & DC distribution panel), required DC & AC distribution panels with surge protection units, cabling from terrace to main distribution board through Cable tray, Bi Directional Energy Meter, Provision of Lightening Arrestor & 2 Nos. GI chemical earthing with suitable size GI strip upto Lightning arrestor, Hot dip galvanized MS Mounting Structures (1No. GI Chemical earthing with suitable size GI strip upto mounting structure) should be designed to withstand the speed for the wind Zone of the location (150 Km/hr-170 Km/hr) Complete in all respect with transportaion, fabrication, labour & Civil Work etc. Features :- 1. Solar PV Module warranty 25 Years & certified under IS/IEC 61730 I & II IS/IEC 61701 & IS/EC 142862. Power Conditioning unit (string solar inverter) & certified under IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, IEC 61683, EN 50530, IEC 60068-2-1, 2, 14, 30, EN 605293. Structure 25 Years service life with AMC & certified under IS 2062 20114. Complete Plant insurance for the period of 5 Years (Excluding Theft of the Material)5. Annual Maintenance contract for the period of 5 YearsConditions:# The Plant will be installed as per MNRE and GOI guidelines and specifications. (Detail of material as per Annexure-I attached)#The work will got done from approved MNRE (Misitry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency) contractor#The capacity of solar power plant my increase or decrees as availability of site it can also be totally removed from executive endThe Rate are inclusive of all taxes including GST Total in Figures 88615617.72 88615617.72 INR Eight Crore Eighty Six Lakh Fifteen Thousand Six Hundred & Seventeen and Paise Seventy Two Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 INR Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail