| 1 | Building work |
| 2 | 5.10.3Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 3 | 5.1.1Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 4 | 5.1.7Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 5 | 5.1.10Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 6 | 5.3.1Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- all work up to plinth level- Foundation 5.3.1.41:3:6 ( 1 cement : 3 coarse sand ( zone - III) ;6 graded stone aggregate 20 mm nominal size). |
| 7 | 5.3.1Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- all work up to plinth level- Foundation 5.3.1.21:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)cum |
| 8 | 5.6.1Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 9 | 5.3.9Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering,finishing and reinforcement. All work up to plinth level ( foundation) 5.3.9.11:1.5:3 (1 cement:1.5 coarse sand( zone III) : 3 graded stone aggregate 20 mm nominal size) |
| 10 | 5.3.17 Centering and shuttering including strutting,propping etc and removal of form for 5.3.17.1Foundations,footings,bases of columns etc for mass concrete |
| 11 | 5.3.10 Reinforced cement concrete work in walls ( any thickness), including attached pilasters,buttresses,plinth and string courses,fillets,columns,pillars,piers,abutments,posts and struts etc . above plinth level up to floor five level excluding cost of centering,shuttering ,finishing and reinforcement 1:1.5:3 (1 cement:1.5 coarse sand( zone III) : 3 graded stone aggregate 20 mm nominal size) |
| 12 | 5.3.17 Centering and shuttering including strutting,propping etc and removal of form for 5.3.17.6Columns,pillars,piers,abutments,posts and struts |
| 13 | 5.3.11Reinforced cement concrete work in beam ,suspended floors,roofs having slope up to 15 landing ,balconies,shelves,chajjas,lintels,bands,plainwindow sills,staircases and spiral stair cases above plinth level up to floor five level,excluding cost of centering,shuttering ,finishing and reinforcement 1:1.5:3 (1 cement:1.5 coarse sand( zone III) : 3 graded stone aggregate 20 mm nominal size) |
| 14 | 5.3.17 Centering and shuttering including strutting,propping etc and removal of form for 5.3.17.21Lintels ,beams,plinth beams,girders,bressumers and cantilevers |
| 15 | 5.2.6Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 16 | 5.2.14Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 17 | 5.3.11Reinforced cement concrete work in beam ,suspended floors,roofs having slope up to 15 landing ,balconies,shelves,chajjas,lintels,bands,plainwindow sills,staircases and spiral stair cases above plinth level up to floor five level,excluding cost of centering,shuttering ,finishing and reinforcement 1:1.5:3 (1 cement:1.5 coarse sand( zone III) : 3 graded stone aggregate 20 mm nominal size) |
| 18 | 5.3.17 Centering and shuttering including strutting,propping etc and removal of form for 5.3.17.19Weather shade, Chajjas, corbels etc., including edges |
| 19 | 5.3.11Reinforced cement concrete work in beam ,suspended floors,roofs having slope up to 15 landing ,balconies,shelves,chajjas,lintels,bands,plainwindow sills,staircases and spiral stair cases above plinth level up to floor five level,excluding cost of centering,shuttering ,finishing and reinforcement 1:1.5:3 (1 cement:1.5 coarse sand( zone III) : 3 graded stone aggregate 20 mm nominal size) |
| 20 | 5.3.17 Centering and shuttering including strutting,propping etc and removal of form for 5.3.17.20Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick |
| 21 | DSR 13.46.1Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 22 | (5.5.4Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complet |
| 23 | 5.5.5Providing Tor steel reinforcement of 10mm , 12mm & 16mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in positio |
| 24 | (a) 10 mm TMT bar FE 500 ( Only Valid for SAIL & TATA Steel ) |
| 25 | (b) 12 mm -20 mm dia TMT bar FE 500 ( Only Valid for SAIL & TATA Steel ) |
| 26 | 5.7.3Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 27 | 5.7.6Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 28 | D.S.R. 13.80Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 29 | 5.8.18Providing two coats of oil bound distemper of approved make & shade over a coat of cement primer over new surface including preparing the plastered surface by rubbing, smooth with pumic stone or fine sand paper, aplying putty wherever required, scaffolding , washing of flores and taxes etc. all complete as per building specification direction of E/I. |
| 30 | DSR / 13.45.1Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm. |
| 31 | DSR 11.41Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.11.41.3 Size of Tile 800x800 mm |
| 32 | DSR 8.31Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 33 | DSR 11.56Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge11.56.1Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent . |
| 34 | DSR 9.147AProviding and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. |
| 35 | After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod pf approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. |
| 36 | Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 shall be paid separately. |
| 37 | Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for: |
| 38 | (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 |
| 39 | (ii) Sites with structure height more than 20m for all wind speeds. |
| 40 | 9.147.A4Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. |
| 41 | 9.147.A4.1Using R2 series with frame (70mm & above) x (40mm & above) & both glazed and fly screen sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 meter). |
| 42 | 5.5.12Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flats as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, hoisting carriage of grill to work site, hoisting as per building specification and direction of E/I. |
| 43 | 5.5.35Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 44 | 5.5.28Labour for fabricating, erecting, hoistion and fixing in position structrral steel work in R.S. Joist, channel, Angle, Tee, flat, plate, latice member, built up compound section in column, girder, stair case, or truss including cost of gusset plates, holding down bolts, anchor plates at all heights and depths, bolting, welding ( machining wherever necessary) with applying a priming coat of red lead paint all complete as per approved drawing, building specification and direction of E/I. |
| 45 | 5.4.1Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I. |
| 46 | 5.8.40Supplying, fitting and fixing 30mm thick solid core type non-decorative single leaf flush door shutter in door and windows with black board core blended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 47 | 5.8.41Provinding primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurment Area shall be multiplied by the co-efficient as indicated in building specificaton.) |
| 48 | 5.8.45Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I |
| 49 | DSR 12.41.2Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 50 | DSR 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. |
| 51 | ( 12.42.5.2) 110 mm bend |
| 52 | ( 12.42.6.2) Shoe 110 mm |
| 53 | DSR 26.89Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. |
| 54 | 26.89.225 mm thick |
| 55 | DSR 29.91Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer numeric control) routed of approved design by Engineer-in -charge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium corbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing on M.S (mild steel) frame made of 25 x 25 x 1.5 mm square hollow box section including applying a priming coat of approved steel primer, placed at grid made at 1.0 x 1.0 m or as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In- Charge. (Note: M.S (mild steel) framework with priming coat and necessary SS fasteners and SS screws shall be paid separately. |
| 56 | MRStainless steel lattering |
| 57 | MRLogo Jharkhand Home Guard 3'0\\"x3'0\\" |
| 58 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 59 | Bricks (1K+21P)= 22 KM |
| 60 | Local sand (3KM) |
| 61 | Coarse sand (16 KM ) |
| 62 | Stone Chips (32 KM) |
| 63 | Cement ( 8 KM) |
| 64 | Steel (8 KM) |
| 65 | Note:- OF MAKE (1)PVC insuleted copper conductor wire of make:-Havell's/Polycab/Anchor (2)PVC conduit of thiknss 1.5mm/2mm for wiring:-Polycab/ANCHOR/AKG (3) GI modular box of make -: Anchor/ Havells/Legrand/ (4)Switches/soket outlet for modular type:- Anchor (roma)/Havells(cabtree)Legrand (5)MCCB,MCB,SFU,CHANGEOVER,RCCB,MCB-DB:-Havell's/L&T/C&S (6)XLPE/PVC aramoured cable:-Havell's/Polycab/V-guard (7) LED ITTING FIXTURE -: Havells/Bajaj/Crompton (Model/as per E/I ) (8) CEALING / WALL / EXHAUST FAN -: Havells / Bajaj / Usha / Crompton (Model/as per E/I ) (9)OCTAGONAL POLE-: Bajaj/Philips/Surya (10) CHEMICAL EARTHING OF MAKE - TRUEPOWER EARTHING (11) CENTRALISED AIR CONDITIONING OF MAKE - VOLTAS/MITSHUBISHI/ TOSHIBA/DAIKIN (12)ALL ELECTRICAL WIRING WORK SHOULD BE CONCEALED |
| 66 | 1.3Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. |
| 67 | 1.3.1Group A |
| 68 | 1.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required |
| 69 | 1.7.22x2.5 sq mm+1x2.5 sq mm earth wire |
| 70 | 1.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required |
| 71 | 1.24.15/6 amps, one way switch |
| 72 | 1.24.4 5/6 amps, 3 pin socket outlet |
| 73 | 1.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required. |
| 74 | 1.27.36 module(78mm x 205mm x 50mm) |
| 75 | 2.8S/F S.P. MCB DB:-Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 76 | 2.8.36 Way,Singlr door |
| 77 | 2.12S/F 'C' series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, 'C' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 78 | 2.12.16/32 amps,single pole, \\"C\\" SERIES |
| 79 | 2.12.640 amps ,DP |
| 80 | 5.1MV cable laying upto 35 sq.mm. in ground:-Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 81 | S/L PVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g |
| 82 | M-73816 sq.mm. 2 core |
| 83 | M - 777Providing of 16'' (400 mm) Wall fan of make bajaj/havells/usha/crompton |
| 84 | M 856Supplying and fixing of LED bulb 15/16 W of make bajaj/havells/crompton |
| 85 | 9.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required. |
| 86 | 9.3.418/20 W LED Round Down Light of make bajaj/havells/crompton/C&S /Jaquar |
| 87 | 9.5S.I.T.C of following rating surface mounted LED tube light fitting suitable for 230 volt 50 Hz single phase supply etc complet as required of make Havells,Bajaj,Crompton, C & S |
| 88 | 9.5.220/22 watt Tube light |
| 89 | 9.1SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required. |
| 90 | 9.1.790 /100 W LED Street light of make bajaj/havells/crompton/C&S /Jaquar |
| 91 | Add 18% GST |
| 92 | Add 1% Lebour Cess Please Enable Macros to View BoQ information |