| 1 | Part D ) 100KVA 11/0.4 KV S/S plinth mounted |
| 2 | WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)-DP (Total Pole Weight with Base Plate & Stiffner=334.84 KG+10.74 KG= 345.58 KG) |
| 3 | Top Channel(GI) GI 100 X 50 X 6 MM |
| 4 | 50x6mm Flat(GI) for earthing, 2.36kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) |
| 5 | Support Channel(GI) 75x40x4.8 mm GI Channel(GI) |
| 6 | GI Channel(GI) 100 X 50 X 6 MM |
| 7 | 100 KVA , 11/ 0.4 KV Transformer, BIS Energy Loss level II, |
| 8 | LT Distribution Box with MCCB, 100 KVA S/S 11/0.4KV |
| 9 | 55 SQ.MM. AAAC XLPE Covered Conductor |
| 10 | 4 Cx 150 mm2 LT XLPE Cable(Armoured) - FOR 63 KVA Trf. |
| 11 | AB Switch(11KV,200A.3pole,50Hz) |
| 12 | H.G.Fuse( 11KV.200A.3Pole) |
| 13 | WEDGE CONNECTOR FOR 55 SQMM.CONDUCTOR |
| 14 | POLYCARBONATE BIRD GUARD |
| 15 | Disc insulator (B&S)70 KN polymer |
| 16 | H W fitting (B&S)70KN(3bolted) |
| 17 | Lightning Arrester(12KV,10KA) Station Class 2 |
| 18 | 11KV pin insulator polymer |
| 19 | HT stay set complete |
| 20 | HT stay Clamp (1.9Kg/pair) |
| 21 | HT stay insulator TYPE-C |
| 22 | 7/10 SWG GI stay wire, Grade -2 (15Kg./ Set) |
| 23 | 40 mm Nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long |
| 24 | GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP) |
| 25 | GI Barbed wire/Anticlimbing device (3Kg /Pole) |
| 26 | Back Clamp for anticlimbing device 25X3 mm. Flat(GI), |
| 27 | Danger plate 11kv |
| 28 | Name plate |
| 29 | yellow color paint (GIS Numbering &zebra stripping) for background |
| 30 | Black Colour Paint (GIS Numbering &zebra stripping) for Numbering |
| 31 | CIVIL and Service Works |
| 32 | Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1800mm) = 0.450Cu.mtr(Per Pole) (For WPB Pole) |
| 33 | PCC ratio 1:3:6(M-10 Grade) For DSS Area (5X3X0.1)= 1.5 Cu. mtr. |
| 34 | Fixing of stay set with 0.5Cum cement concrete foundation 1:3:6(M-10 Grade) size ( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set , stay wire , stay insulator . |
| 35 | Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earthresistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI)around pipe . |
| 36 | Laying of 1.1KV cable 185 to 400 sq mm |
| 37 | SITC and Erection of GI Fencing with Gate |
| 38 | Construction of Trf plinth for 250 KVA |
| 39 | Supply of AL Lugs suitable for 95 sq mm cable/conductor, Crimping with cable and Fixing/connecting include supply and erection of PVC Tape as per voltage requirement. |
| 40 | Supply and erection of double Compression Flameproof Type Glanding for armored Cable 3.5/4C 50-95sqmm including making hole in Base plate and dressing of cable along with vermin proofing properly .Supply to be done as per TPCODL Spec and approved make dowells. |
| 41 | No. of Cut Point with 90 Degree Angle |
| 42 | Supply and fixing of GI Chanel 100X50X6mm channel |
| 43 | Supply and fixing of 50x6mm Flat(GI) |
| 44 | Supply and fixing of 11 KV pin insulator polymer |
| 45 | Supply and fixing of H W fitting(B&S) 70KN, 3Bolt |
| 46 | Supply and fixing of Disc insulator (B&S) 70 KN polymer |
| 47 | Supply and fixing of Non metallic ties -11KV 55sq mm CVRD AAAC |
| 48 | Supply and fixing of IPC for 11KV 55 sq mm CVRD AAAC |
| 49 | H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair) |
| 50 | H.T. Stay set (Complete ) |
| 51 | H.T. Stay Insulator Type-C |
| 52 | 7/10 SWG Stay Wire 15kg /stay |
| 53 | GI Nut , Bolt & Washer of different sizes (3.55 Kg each Cut Pole) |
| 54 | CIVIL and Service Works |
| 55 | Fixing of complete 11KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard. |
| 56 | Supply and fixing of AAAC 11KV XLPE INSU. CVRD. CDTR 55 sq mm |
| 57 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 58 | 3.5core x 120 sq mm ( with required lugs ) |
| 59 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 60 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 61 | 200 mm dia Please Enable Macros to View BoQ information |