| 1 | Dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead for thickness of tiles 10mm to 25mm. |
| 2 | Dismantling old plaster or skirting racking out joints and cleaning the surface for plaster incl.disposal of rubbish to the dumping ground within 50 mtr.lead. |
| 3 | Renewing glass panes, with putty and nails wherever necessary Float glass panes of thickness 4 mm |
| 4 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand) |
| 5 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Jhunjhunu / Jalore Red/Choclate/Black/Pink Colour) Above 3601 Cm2 Slabs |
| 6 | Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge Granite/Kota Stone Work Full Edge moulding |
| 7 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 8 | Providing and laying brick kharanja on roofs with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound in square pattern 75mm to 100mm thick average |
| 9 | Grinding of existing floor with 60, 80, 120 and 360 No. Carborundum stone including costof wax polishing complete |
| 10 | Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finished 25 mm thick. |
| 11 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joints etc. complete fine finished 20 mm thick. |
| 12 | Finishing with neat cement (punning). |
| 13 | P/L damp proof course with cement concrete grade M-150 (1:2:4) mortar prepared with 1% solution of waterproof compound incl. Two coats of hot blown bitumen (2Kg/Sqm.) complete as per specification with glass strip 3mm thick at a distance of 1m interval 75mm thick. |
| 14 | P/F Ist quality standard White, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles of ISI marked (IS:13753) of size 200mmx300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster on walls & pillar) Extra for using size above 200x300mm in glazed tiles . |
| 15 | P/F Ist quality MAT finished ceramic tiles 300x300mm confirming to IS:13753 colour such as white, grey, ivory fume red brown, in walls, floors, steps, pillars etc. laid on a bed on neat cement slurry including nicely finished joints using waterproof joint filler powder and finishing with flush pointing in white cement mixed with pigment to match the shade of tile complete (including the cost of cement mortar bed 1:4) |
| 16 | Carriageof earth including loading, unloading etc. lead upto 5.0 Km. |
| 17 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Old work (One or more coats ) |
| 18 | Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision old work |
| 19 | Providing and applying white cement based putty overplastered surface to prepare the surface even and smoothcomplete New Plastered Surface (three or more coats) |
| 20 | Applying one coat of Cement primer of approved brand and manufacture on wall surface including all scaffolding: |
| 21 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 22 | Repair to damaged RCC slabs, beams and columns etc for strengtheing with cement mortar 1 : 3 in following stepsi) Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried.ii) Applying Epoxy primer on the exposed steel bars.iii) Applying Epoxy hardener and resin mix (as per manufectured's specification) on concrete and steel bars with brush.iv)Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day.v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete.vi) Cure the plastered surface for 15 days |
| 23 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish lead up to 50 mtr and lift up to 1.5 mtr All kinds of soil |
| 24 | S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead andlift with scafolding. |
| 25 | P/F steel gate, grating and grills made of angles, tees, square bars, flats or black pipe with holdfast and fittings complete as per design and drawing including cutting, welding and fabrication with priming coat of red oxide. |
| 26 | Extra if square,rectangular hollow tubelar sections are used or grill made by flats only |
| 27 | P/F M.S. sheet single leaf door shutter in angle iron frame 35x35x5mm suitability diagonally braced with 25x3 mm flat iron of above and below lock rail of size 50x5mm beading extra including all fittings as per direction Engg. Incharge but excluding cost of chowkhats including two coats of anticorrosive red oxide primer paint M.S. sheet 18 S.W.G. |
| 28 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils |
| 29 | R.R dry stone kharanja under floor |
| 30 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 31 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand)Dark shade using ordinary cement. |
| 32 | Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4, ralthal, stone kharanja, lime terracing 90mm average thickness (as per JAIPUR PRACTICE ) with ceiling pointing in cement sand mortar 1:3 complete as per specification for span above 2.50 mtr. And up to 3.0 mtr. for first floor. |
| 33 | Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleatangle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately). For fixed portion Anodised aluminum (anodised ansparent 81 dyed to required shade according to IS : 868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) Powder coating aluminum ( minimum thickness of powder coating 50 micron) |
| 34 | __do__ for shutters of openable doors, windows and ventilators including providing & fixing hinges/rollers etc. and making provision for fixing of fittings wherever required (lockers shall be paid for separately.).Powder coating aluminum ( minimum thickness of powder coating 50 micron) |
| 35 | Providing and fixing 12mm thick prelaminated three layer medium density (exterior grade) particle board Grade I, Type II conforming to IS:12823 bonded formaldehyde synthetic resin of approved brand and manufacture in paneling fixed in alluminium doors, windows, shutters and partition frames with C.P., brass/ stainless steel screws etc.complete as per architectural drawings and direction of Engineer Incharge. Prelaminated particle board with decorative lamination on both sides. |
| 36 | P&F glazing in aluminium door, window, ventilator, shutters and partitions etc. with P.V.C./Neoprene or gasket etc.complete as per the architectural drawings & the directions of Engineer Incharge. (cost of Aluminium snap beading shall be paid in basic item). with glass panes of 5.0mm thickness (weight not less than 13.75 Kg/sqm). |
| 37 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. With stainless steel cover plate |
| 38 | Construction of Chamber in all types of soil 300mm thick masonry in C.M. 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick inside plaster in C.M. 1:6 finished with floating neat cement 50mm thick M-15 grade C.C. flooring earth work etc. complete as per design incl. disposal of surplus earth within a lead of 50 mtr. Inside size 600 x 450mm depth upto 0.5 M Cement cover with frame. |
| 39 | Construction of Manhole in all types of soil inner size 1.5x1.2 M with 450mm thick masonry in C.M. 1:6, 10 cm thick cement concrete 1:5:10 in foundation 20mm thick inside plaster in C.M. 1:6 finished with floating neat cement 50mm thick M-15 grade C.C. flooring making channels 80mm thick stone slab covering with 40mm thick stone M-15 grade C.C. flooring, Ferro cement cover with frame of 450mm dia earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. Lead as per desing depth upto 1.5 M. |
| 40 | Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthworkcomplete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 300 Cm. dia outside & 300 Cm. depth . |
| 41 | Emptying of Septic tank ,Soakage well etc. by disposing or sludge upto 5 Km. lead & taking out sewage including cleaning of site. |
| 42 | Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M- 15 grade C.C floor & RCC slab covering with M15 grade c.c. floor, 50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:-Size 400 x140x150 cm.(for 50 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 10mm ϕ @15 cm c/c bothways including shuttering complete in all respect. |
| 43 | Providing & applying one coat of UV resistant polymer cement based waterproofing slurry coating of approved make and quality on concrete or plastered surface as per specifications including preparation of surface by cleaningbrushing and dust removing, filling of cracks and making the surface leak proof by mixing one part of chemical with 2 parts of cement and 2 parts of water (covering area 1.86 Sq.M/Kg of chemical) including cost of cement, labour, tools & plant, scaffolding if necessary etc., complete as directed by Engineer in Charge. Note: Undulations/cracks found on the surface should be rectified with Cement Motor before application and the samewill be paid under relavent items. |
| 44 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 45 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 46 | P/L damp proof course with cement concrete grade M-150 (1:2:4) mortar prepared with 1% solution of waterproof compound incl. Two coats of hot blown bitumen (2Kg/Sqm.) complete as per specification with glass strip 3mm thick at a distance of 1m interval 75mm thick. |
| 47 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' :35 mm thick .Decorative teak veneer both side Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) |
| 48 | Providing and fixing to existing door frames. 30mm thick factory made solid both side Pre laminated panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles and 15x15mm top & bottom rails. M.S .frame shall have a coat of steel primers of approved make and manufacture M.S. frame covered with 5mm thick heat moulded PVC „C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either sideforming stiles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2) thick, 20mm wide cross PVC sheet shall be provided as gapinsert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with 7mm (5mm +2mm) thick x 15mm wide PVCsheet bending on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the „C Channel using PVC solvent adhesive etc. complete as per direction ofEngineer-in-charge, manufacture‟s specification & drawing.(For W.C.and bathroom door shutter). |
| 49 | P & F 15 mm. Dia Connection Pipe of approved quality/make PVC pipe with C.P. Brass nuts upto length, 600mm |
| 50 | Providing and fixing Superior quality CP Brass fittings of approved make as per direction of Engineer-in-charge Health focet (Premium heavy Quality) as approved by Engineer-in-Charge |
| 51 | Providing and fixing premium quality Angular stop cock 15mm with wall flange complete as per sample approved by Engineer in charge |
| 52 | P & F Grating of approved quality/make: Synthetic Material(PTMT) of approved quality/make Square 150 x 150 x 8mm. (Anti Cockroach) |
| 53 | Providing and fixing Superior quality CP Brass fittings of approved make as per direction of Engineer-in-charge pillar cock 15 mm nominal size |
| 54 | Providing and fixing Superior quality CP Brass fittings of approved make as per direction of Engineer-in-charge Long body Bib Cock 15 mm nominal size |
| 55 | P/F rigid PVC pipe (IS:4985 mark) class II (4 Kg./Cm2) approved quality/make incl. jointing the pipe with solvent cement rubber ring and lubricant 110 mm dia. |
| 56 | P/F rigid PVC pipe fittings (IS:4985 mark) of approved quality/make incl. jointing the pipe with solvent cement rubber ring and lubricant plain tee 110mm |
| 57 | ---do--- Door Tee 110mm |
| 58 | ---do--- Bend 87.5, 110mm dia. |
| 59 | ---do--- Door Bend (Top side) 110mm dia. |
| 60 | (---do---) coupler (Socket) 110mm |
| 61 | __do__ Plain floor trap 110mm dia. |
| 62 | (--do—) Pipe Clip 75mm |
| 63 | (--do—) Pipe Clip 110mm |
| 64 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with onestep CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) 20 mm nominal size |
| 65 | (--do--)25mm nominal size |
| 66 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge. (External work).25mm nominal size |
| 67 | (--do--)50mm nominal size |
| 68 | P/F full way valve (IS:778 mark) or wheel valve of approved make Gun metal 25mm nominal bore. |
| 69 | (-do-) 50mm nominal bore. Please Enable Macros to View BoQ information |