| 1 | Item Wise BoQ BoQ_Ver3.0 Item Wise Normal INR Only INR Select, Excess (+), Less (-) Tender Inviting Authority: Name of Work: Contract No: Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(DOMESTIC TENDERS - RATES ARE TO GIVEN IN RUPEES (INR) ONLY)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Service Description Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder inRs. P Excise Duty Amount in INR Rs. P GST Amount in INR Rs. P Freight Charges ( Unloading & Stacking) inRs. P Any Other Taxes inRs. P Any Other Duties/Levies inRs. P IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxescol (13) = (4) x (7) inRs. P TOTAL AMOUNT With Taxescol (14) = sum (8) to (13) inRs. P TOTAL AMOUNT In Words |
| 2 | Civil Work |
| 3 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 4 | For thickness of tiles 10 mm to 25 mm |
| 5 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 6 | In cement mortar |
| 7 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 8 | Of area 3 sq. metres and below |
| 9 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 10 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineerin-charge. |
| 11 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 12 | All kinds of soil |
| 13 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 14 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 15 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 16 | 12 mm cement plaster of mix : |
| 17 | 1:6 (1 cement: 6 coarse sand) |
| 18 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 19 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 20 | New work (Two or more coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm) |
| 21 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. |
| 22 | Two coats |
| 23 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 24 | Two or more coats on new work |
| 25 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 26 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. |
| 27 | Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm |
| 28 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 29 | 25 mm thick |
| 30 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 31 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 32 | 20 mm nominal dia Pipes |
| 33 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 34 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 35 | Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size andshape wherever required. |
| 36 | Extra for straight cutting in reinforced by organic fibres and/orinorganic synthetic fibres cement corrugated, semi corrugated 6 mm thick sheet roofing for making openings of area exceeding 40 square decimeter for chimney stacks, skylights etc. |
| 37 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 38 | Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 600 mm centre to centre both ways (vertically & horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge. |
| 39 | Providing and fixing Pre -laminated medium density fibre board exterior grade (Grade-I) IS:14587:1998 marked, to frame, backing or studding with screws etc. complete ( Frames, backing or studding to be paid separately). |
| 40 | Pre-laminated with decorative lamination on both side exterior Grade - I MDF Board 18 mm thick confirming to IS:14587 |
| 41 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 42 | With float glass panes of 8 mm thickness (weight notless than 20 kg/sqm) |
| 43 | Fixing of existing doors/windows of size 3 sqm or below. |
| 44 | Electrical Works |
| 45 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable in surface/recessed steel conduit, with modular switch, modularplate, suitable GI box and earthing the point with 1.5sq.mm FRLS/HFFR PVC insulated copper conductorsingle core cable etc. as required. |
| 46 | Group B |
| 47 | Wiring for light/ power plug with 2X4 sq.mmFRLS/HFFR PVC insulated copper conductor singlecore cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copperconductor single core cable for loop earthing asrequired |
| 48 | Wiring for circuit/ submain wiring along with earth wirewith the following sizes of FRLS/HFFR PVC insulatedcopper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 49 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 50 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 51 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 52 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 53 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 54 | Supplying and fixing of following sizes ofmedium class PVC conduit along withaccessories in surface/recess including cuttingthe wall and making good the same in case ofrecessed conduit as required. |
| 55 | 25 mm |
| 56 | 50 mm |
| 57 | Supplying and laying DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required |
| 58 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 59 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excludingmodular plate etc. as required. |
| 60 | 15/16 A switch |
| 61 | 6 pin 15/16 A socket outlet |
| 62 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. asrequired. |
| 63 | 3 Module (100mmX75mm) |
| 64 | 6 Module (200mmX75mm) |
| 65 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required |
| 66 | 3 Module |
| 67 | 6 Module |
| 68 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 69 | Triple pole and neutral |
| 70 | Supplying and fixing following rating C curveMCB in the existing MCB DB complete withconnections, testing and commissioning etc.as required. |
| 71 | 63Amp TPMCB |
| 72 | 63Amp FPMCB |
| 73 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 74 | 4 way (4 + 12), Double door |
| 75 | Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V, TPNMCB distribution board of sheet steel, dustprotected, duly powder painted, inclusive of200 A tinned copper bus bar, common neutrallink, earth bar, din bar for mounting MCBs (butwithout MCBs and incomer ) as required .(Note : Vertical type MCB TPDB is normallyused where 3 phase outlets are required.) |
| 76 | 12 way (4 + 36), Double door |
| 77 | Providing and fixing following capacity TP&Ndisconnector fuse switch unit inside the existing panelboard with ISI marked HRC fuses including drillingholes in cubicle panel, making connections, etc. asrequired. |
| 78 | 63 A TP&N |
| 79 | Supplying of ISI marked XLPE insulated andPVC sheathed armoured aluminium conductorpower cable of 1.1 KV grade confirming toIS:7098 (Part-1) 1988 of following size etc asreqd. |
| 80 | 3.5 x 95 sq.mm |
| 81 | 3.5 x 25 sq.mm |
| 82 | Laying of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV gradeof following size in the existing RCC/ HUME/METAL pipe as required. |
| 83 | Upto 35 sq. mm |
| 84 | Above 35 sq. mm and upto 95 sq. mm |
| 85 | Installation, Testing and Commissioning of exhaustfan in the existing opening, including making good thedamage, connection, testing, commissioning etc. asrequired. |
| 86 | 510 mm sweep |
| 87 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 88 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt )Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver &electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED |
| 89 | 18 watt Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select % 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |