Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: MR. Anukaran J Kandir, Senior Manager (Contract), Contract Cell. GRSE Limited ITEMS : CONSTRUCTION OF G+3 COMPOSITE STRUCTURE BUILDING FOR WORKERS CHANGE ROOM AND CANTEEN FACILITY AT FOJ UNIT, GRSE KOLKATA E-Tender No.: SCC/AJK/OT PRESS/COMP STR BLDG/FOJ/277/ET-3389 Date-12.03.2026 Name of the Bidder/ Bidding Firm / Company : PRICE BID : ANNEXURE C (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender.) NB: (i) UOM=Unit of Measurement; ii) sqm. = square meter, iii) Cum = Cubic Metre, iv) Qntl = Quintal , v) MT = Metric Tone, vi) Mtr = Metre, vii) M = Metre, viii) ix)KG=Kilogram, x) LTR= Litre xi) LS= Lump Sum, NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # . Job Description Item No. QUANTITY UOM Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency UNIT RATE (INR) WITHOUT GST GST PERCENTAGE (%) GST Amount in INR Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies HSN / SAC Code * Name of Supply State / UT DRGS NO. Name of Supply State / UT Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category SAC Name of Supply State / UT TOTAL AMOUNT Without Tax TOTAL AMOUNT With Tax TOTAL AMOUNT In Words |
| 2 | (Civil Work) |
| 3 | Detailed survey, Design, Drawing & Detailing as mentioned below : a.Reviewing of the detail design of the proposed structure, drawing and detailing for Civil, electrical structures b. All short of CB14:B321detailing c.Obtaining vetting of final design & drawing by any Institute either JU /IIEST/IIT/NIT d.Detailed survey of adjacent area with Auto Level &Total Station e. Obtaining approval from WBF&ES,KMC etc. other local bodies f. Registration, documentation, coordination with the certifying authority and obtaining Green Building Certification from GRIHA/IGBC/ LEED as approved by GRSE. f. As-built drawing (All drawing should be submitted both in hard and soft copies along with PDF & Auto Cad files) |
| 4 | Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specifieddiameter and length below the pile cap, to carry a safeworking load not less than specified, excluding the cost of steel reinforcement but including the cost of boring withbentonite solution and temporary casing of appropriatelength for setting out and removal of same and the length ofthe pile to be embedded in the pile cap etc. by percussiondrilling using Direct mud circulation (DMC) or Bailer andchisel technique by tripodand mechanical Winch Machineall complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured upto bottom of pile cap). Note : Truck Mounted rotary/TMR/Tubewell boring machine shall not be used . For 500 mm dia piles. |
| 5 | Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D. |
| 6 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Single pile Above 50 tonne upto 100 tonne Safe capacity. Initial test (Test Load 2.5 times the Safe capacity) |
| 7 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Single pile Above 50 tonne upto 100 tonne Safe capacity. Routine test (Test Load 1.5 times the Safe capacity) |
| 8 | Integrity testing of Pile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge |
| 9 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift up to 1.5 m (i) All kinds of soil |
| 10 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means for foundations,pits,trenches, footing over areas (exceeding 30cm in depth. 1.5 m in widthas well as 10 Sq.m on plan) including dressing of sides andramming of bottom ,lift upto 1.5 m,de-watering, shoring,strutting , taking out the excavated earth & disposal of excavated earth as directed within a lead upto 50m ,disposed earth to be levelled and neatly dressed all complete as per specifications and as directed by Engineer. (Only PCC plan area as per drawing shall be measured for payment.) (i) All kinds of soil |
| 11 | Open timbering over areas including strutting, shoring etc. complete. (Measurements to be taken of the face area timbered): Depth exceeding 1.5 m but not exceeding 3 m |
| 12 | Extra rates for quantities of works, executed: In or under water and/or liquid mud, including pumping out water as required, Extra due to slow progress and dewatering: 20% of the rate of the item |
| 13 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 14 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 15 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 16 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. |
| 17 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% (Each Containers Contains 5 L Chemicals) |
| 18 | Diluting and injecting chemical emulsion for POSTCONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided usingchemical emulsion @ 7.5 litres / Sq.m of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 19 | Diluting and injecting chemical emulsion for POSTCONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along the external wall below concrete or masonry apron using chemical emulsion @ litres per linear metre including drilling and plugging holes etc.: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 20 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth |
| 21 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. Pakur variety |
| 22 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering,shuttering, finishing and reinforcement - All work : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived fromnatural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 23 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works at any level. Concrete of M25 grade with minimum cement content of 330 kg /Cu. m. (with pump) |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, Walls (any thickness) including attached pilasters, butteresses, plinth and string courses , Suspended floors, roofs, landings, balconies and access platform , Lintels, beams, plinth beams, girders, bressumers and cantilevers etc. at any level for any type section with suitable steel or 9 to 12mm thk ply shuttering |
| 25 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 26 | Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3 mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately). |
| 27 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces |
| 28 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:6 (1 cement : 6 coarse sand) : for 2B+G+4 |
| 29 | Half brick masonry with non modular fly ash bricks of class designation 10, conformingio IS :12894, in super structure above plinth upto floor V level. cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 30 | 20 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) Outside wall plaster. |
| 31 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand). Inside wall plaster. |
| 32 | Providing 6mm. thick cement plaster on ceiling: 1:3 (1 cement : 3 fine sand) |
| 33 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 34 | Neat cement punning. |
| 35 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per Sq.m |
| 36 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal surface one coat @1.10 kg per Sq.m. |
| 37 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/Sq.m mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per Sq.m of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/Sq.m). |
| 38 | Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or / and residual bitumen applied hot at 1.45, 1.20 and 1.70 kg per square metre of area respectively, second and fourth courses of roofing felt type 2 grade I (fibre base self finished bitumen felt) six and final courses of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic decimeter per Sq.m including preparation of surface, excluding grading, compete. |
| 39 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even andsmooth complete. Internal wall & Ceiling. |
| 40 | Applying 2 priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content with water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. Internal wall & Ceiling. |
| 41 | Wall Painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour over one coat of int. primer. Painting ceiling & wall with Two coats |
| 42 | Applying 2 priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content with ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre Over wood work |
| 43 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture Over appropriate wood/ steel primer excepting over pipes. |
| 44 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) |
| 45 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)) Over Exterior surface |
| 46 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 47 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 48 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1cement : 4 coarse sand) : 25 mm thick |
| 49 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 50 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. Placed over Toilet Wall and floor |
| 51 | Supplying, fitting & fixing best quality digital printed Ceramic tiles in coloured decorative on walls and floors to match with the existing work & 4 nos. key stones (10mm) fixed with adhesive 4.5 mm thick at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. With polymerised adhesive and epoxy grout pointing including spacer - 2mm (When tiles are laid over existing hard ready surface) all complete as per direction of Engineer-in-charge. |
| 52 | 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] |
| 53 | Taking out carefully G.C.I. or C.I. or asbestos sheets (including ridges etc.) from roof or wall after unscrewing bolts, nuts, screws etc.and stacking the material at site as directed. |
| 54 | Labour for lowering and stacking after dismantling in parts R.S. joists, channels, angles, tees, plates etc.complete as directed. (a) From 1st floor level |
| 55 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. |
| 56 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Sal wood Door |
| 57 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 58 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 100X58X1.90 mm |
| 59 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete as per instructions of EIC (i) 150x10 mm |
| 60 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete as per instructions of EIC (ii) 300x10 mm |
| 61 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete |
| 62 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete |
| 63 | Supplying Zinc powered coated star lock |
| 64 | Supplying 'Godrej' mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete. |
| 65 | Providing and fixing 50 cm long aluminium kicking plate of size 100x3.15mm, anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 66 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm |
| 67 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete., Hardwyn make (Classic Queen) or equivalent with necessary accessories and screws etc. complete. |
| 68 | Extruded aluminium tubular type hydraulic door closer of Hardwyn (Gazel), GODREJ or equivalent for Glazed Al doors of rear entrance doors etc. |
| 69 | Fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/Sq.m) duly filled with vermiculite based concrete mix, suitable for mounting 120 minutes fire rated door shutters. The frame is fitted with intumescent fire seal strip of size 10x4 mm (minimum) all round the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete. At All Floors |
| 70 | 50 mm thick glazed fire resistant door shutters of 120 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. At All Floors |
| 71 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces |
| 72 | Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. All grill and railing |
| 73 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 74 | Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured) |
| 75 | Calcium silicate False Ceiling : Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per Sq.m including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges caliCu. m silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 Sq.m.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK. At all floor |
| 76 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / .. Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (70mm & above) x (40mm & above) & both glazed and fly screen sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metre). |
| 77 | Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screen sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m). |
| 78 | Three track three panels sliding door with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on two panels along with multi-point locking system, adjustable nylon rollers with SS 304 body. Fixed window / ventilator without mullion / transom. Using R2 series with frame (39mm & above ) x (39mm & above). (Height upto 1.2 metre) |
| 79 | Ventilator Casement window single panel with or without fixed panel with S.S. 304 friction hinges as per size and weight of sash, single point locking zinc alloy (zamak) powder coated handles. Using R1 series with frame (33mm & above ) x (35mm & above) & sash /mullion (33mm & above) x (50 mm & above). (Height upto 0.90 metre). |
| 80 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width |
| 81 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ Sq.m) |
| 82 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 83 | Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 84 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification |
| 85 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 86 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe. 32 mm dia |
| 87 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :. ectangular shape 453x357 mm |
| 88 | Supplying, installing and fixing in position toilet paper roll holder including accessories like bolts, screws, washers as applicable, in all respect complete including making good the walls as per site engineers supervision. |
| 89 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge |
| 90 | Providing and fixing brass liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. Weighing not less than 105 gms. |
| 91 | Providing and fixing SS towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms |
| 92 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore |
| 93 | Supplying, fitting and fixing bib cock or stop cock. (a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand) |
| 94 | Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately). |
| 95 | Supplying, installing and fixing in position of angular stop cock (exposed) with fitting sleeve, operating lever, & adjustable wall flange with seal including accessories in all respect complete including cutting and making good the walls as required as per site engineer's instructions. ( FLR5053N) |
| 96 | Supplying, fitting & fixing approved patent vent cowl I.C.I. conforming to I.S.S and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). (i) 100 mm dia. |
| 97 | Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2\\" BSP thread and shapes, weighing not less than 60 gms. |
| 98 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. (i) 635 mm X 395 mm X 420 mm |
| 99 | Supplying, installing and fixing in position Tishu paper dispencer including accessories like bolts, screws, washers as applicable, in all respect complete including making good the walls as per site engineers supervision. |
| 100 | Supplying, and fixing in position Tishu paper basket including accessories like bolts, screws, washers as applicable, in all respect complete including making good the walls as per site engineers supervision |
| 101 | Supplying, installing, testing and commissioning of stainless steel Kitchen sink with long body sink cock with aerator (size to be confirmed after kitchen consultant provides kitchen equipment and detail drawing) manufactured from 1 mm thick steel, grade SS-304 with top quality polish, 1no. 40mm dia CP waste coupling, with flexible hose pipe connection upto floor trap with accessories bolts, screws, washers, water supply /drain connection etc as applicable, complete including making good the wall as per site engineer's instructions. |
| 102 | Providing and fixing soil, waste and vent pipes: Supplying, fixing, testing and commissioning of unplasticized PVC soil and waste pipes (SWR Type - B) with solvent cement joints & fittings conforming to IS 13592, with all necessary fittings and accessories like hangers, brackets, bends, tees, offsets, doorbends, junctions, cowls etc., laid under floor/ fixed on walls etc., complete with pressure testing and commissioning of system. The fittings should be of pasted type (solvent cement). The quoted rate shall be inclusive of cost of suitable supports, clamps etc. (For Soil, Waste ) 32 mm diameter : |
| 103 | Supplying, fixing, testing and commissioning of unplasticized PVC soil and waste pipes (SWR Type - B) with solvent cement joints & fittings conforming to IS 13592, with all necessary fittings and accessories like hangers, brackets, bends, tees, offsets, doorbends, junctions, cowls etc., laid under floor/ fixed on walls etc., complete with pressure testing and commissioning of system. The fittings should be of pasted type (solvent cement). The quoted rate shall be inclusive of cost of suitable supports, clamps etc. (For Soil, Waste ) 50 mm diameter : |
| 104 | Supplying, fixing, testing and commissioning of unplasticized PVC soil and waste pipes (SWR Type - B) with solvent cement joints & fittings conforming to IS 13592, with all necessary fittings and accessories like hangers, brackets, bends, tees, offsets, doorbends, junctions, cowls etc., laid under floor/ fixed on walls etc., complete with pressure testing and commissioning of system. The fittings should be of pasted type (solvent cement). The quoted rate shall be inclusive of cost of suitable supports, clamps etc. (For Soil, Waste ) 100 mm diameter : |
| 105 | Supplying, fixing, testing and commissioning of unplasticized PVC soil and waste pipes (SWR Type - B) with solvent cement joints & fittings conforming to IS 13592, with all necessary fittings and accessories like hangers, brackets, bends, tees, offsets, doorbends, junctions, cowls etc., laid under floor/ fixed on walls etc., complete with pressure testing and commissioning of system. The fittings should be of pasted type (solvent cement). The quoted rate shall be inclusive of cost of suitable supports, clamps etc. (For Soil, Waste ) 75 mm diameter : |
| 106 | Supplying, fixing and testing unplasticized PVC pipes (SWR Type A) confirming to IS 13592:1990, with rubber ring joint inclusive of all necessary fittings and accessories like hangers, brackets, bends, tees, offsets, doorbends, junctions, cowls etc. with intermediate grease interceptors as necessary, complete with pressure testing and commissioning of system.The quoted rate shall be inclusive of cost of suitable supports,clamps etc (For Rain water pipe) 100 mm diameter : |
| 107 | Supplying, fixing and testing unplasticized PVC pipes (SWR Type A) confirming to IS 13592:1990, with rubber ring joint inclusive of all necessary fittings and accessories like hangers, brackets, bends, tees, offsets, doorbends, junctions, cowls etc. with intermediate grease interceptors as necessary, complete with pressure testing and commissioning of system.The quoted rate shall be inclusive of cost of suitable supports,clamps etc (For Rain water pipe) 75 mm diameter : |
| 108 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: (iii) 160 mm. Dia (including fitting & fixing) |
| 109 | Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency]. (b) With Chawk Dungri (iii) Area of each tile exceeding 0.6 sq.m but not excedding 1 sq.m. |
| 110 | Supply and installation of PVC clean out plugs with suitable inset keys for pvc pipes with a threaded socket as necessary. Actual qty may vary as per site conditions |
| 111 | Supply, installation and fixing in position PVC floor trap with SS Grating with a minimum water seal of 50mm complete including cost of cutting and making good the walls and floors as per site engineer's instruction. i) setting the drain in cement concrete 1:2:4 ii)inlet with a perforated 1.25mm thick S.S 304 grating iii) P or S-trap arm of desired length iv) with in-built cockroach trap , 100 mm inlet and 75 mm outlet |
| 112 | Supplying, fitting and fixing in position of PVC P-trap with unions, rubber adapters, waste connection & all accessories with suitable supports and a water seal of minimum 40 mm and making good the same complete including making good the walls and floors wherever required as per site engineer's supervision. |
| 113 | Supplying, installing, fixing, jointing, testing and commissioning of approved make Chlorinated Polyvinyl Chloride pipes (CPVC) , SDR 13.5, ASTM CTS, with necessary supporting system for the pipes & fittings. Fittings up to 50mm dia SDR-13.5, ASTM CTS and above 50mm dia CPVC CORZON schedule 40 fittings. The fittings and specials such as tees, elbows, couplers, bends, enlargers etc.,with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement mortor 1:1 restore the same original condition neately as directed by the Engineer in-charge . Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724. Internal work - Exposed on wall. 20 mm dia pipe |
| 114 | Supplying, installing, fixing, jointing, testing and commissioning of approved make Chlorinated Polyvinyl Chloride pipes (CPVC) , SDR 13.5, ASTM CTS, with necessary supporting system for the pipes & fittings. Fittings up to 50mm dia SDR-13.5, ASTM CTS and above 50mm dia CPVC CORZON schedule 40 fittings. The fittings and specials such as tees, elbows, couplers, bends, enlargers etc.,with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement mortor 1:1 restore the same original condition neately as directed by the Engineer in-charge . Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724. Internal work - Exposed on wall. 25 mm dia pipe |
| 115 | Supplying, installing, fixing, jointing, testing and commissioning of approved make Chlorinated Polyvinyl Chloride pipes (CPVC) , SDR 13.5, ASTM CTS, with necessary supporting system for the pipes & fittings. Fittings up to 50mm dia SDR-13.5, ASTM CTS and above 50mm dia CPVC CORZON schedule 40 fittings. The fittings and specials such as tees, elbows, couplers, bends, enlargers etc.,with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement mortor 1:1 restore the same original condition neately as directed by the Engineer in-charge . Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724. Internal work - Exposed on wall. 32 mm dia pipe |
| 116 | Supplying, installing, fixing, jointing, testing and commissioning of approved make Chlorinated Polyvinyl Chloride pipes (CPVC) , SDR 13.5, ASTM CTS, with necessary supporting system for the pipes & fittings. Fittings up to 50mm dia SDR-13.5, ASTM CTS and above 50mm dia CPVC CORZON schedule 40 fittings. The fittings and specials such as tees, elbows, couplers, bends, enlargers etc.,with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement mortor 1:1 restore the same original condition neately as directed by the Engineer in-charge . Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724. Internal work - Exposed on wall. 40 mm dia pipe |
| 117 | Supplying, installing, fixing, jointing, testing and commissioning of approved make Chlorinated Polyvinyl Chloride pipes (CPVC) , SDR 13.5, ASTM CTS, with necessary supporting system for the pipes & fittings. Fittings up to 50mm dia SDR-13.5, ASTM CTS and above 50mm dia CPVC CORZON schedule 40 fittings. The fittings and specials such as tees, elbows, couplers, bends, enlargers etc.,with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement mortor 1:1 restore the same original condition neately as directed by the Engineer in-charge . Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724. Internal work - Exposed on wall. 50 mm dia pipe |
| 118 | Supplying, installing, fixing, jointing, testing and commissioning of approved make Chlorinated Polyvinyl Chloride pipes (CPVC) , SDR 13.5, ASTM CTS, with necessary supporting system for the pipes & fittings. Fittings up to 50mm dia SDR-13.5, ASTM CTS and above 50mm dia CPVC CORZON schedule 40 fittings. The fittings and specials such as tees, elbows, couplers, bends, enlargers etc.,with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement mortor 1:1 restore the same original condition neately as directed by the Engineer in-charge . Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724. Internal work - Exposed on wall. 65 mm dia pipe |
| 119 | Supplying, installing, fixing, jointing, testing and commissioning of approved make Chlorinated Polyvinyl Chloride pipes (CPVC) , SDR 13.5, ASTM CTS, with necessary supporting system for the pipes & fittings. Fittings up to 50mm dia SDR-13.5, ASTM CTS and above 50mm dia CPVC CORZON schedule 40 fittings. The fittings and specials such as tees, elbows, couplers, bends, enlargers etc.,with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement mortor 1:1 restore the same original condition neately as directed by the Engineer in-charge . Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724. Internal work - Exposed on wall. concealed work including cutting chases and making good the wall etc. 20 mm dia pipe (Vertical Drop in wall) |
| 120 | Supplying, testing and laying in position of HDPE Pipe (PE-63) working pressure 10 kg/sq.cm (SWR) over a bed of brick soling and 100 mm thick sand cushion bed and covered upto 100 mm above crown with sand, laid correct to line , slope and level, cleaning the pipes after laying, testing the pipes with running water between manholes as per specifications and finally commissioning the same. Depth of pipe laying - inverts varying as per slope and as provided in drawing. (For Soil, Waste). EXTERNAL DRAINAGE WORK. 150 mm diameter |
| 121 | Supplying, testing and laying in position of HDPE Pipe (PE-63) working pressure 10 kg/sq.cm (SWR) over a bed of brick soling and 100 mm thick sand cushion bed and covered upto 100 mm above crown with sand, laid correct to line , slope and level, cleaning the pipes after laying, testing the pipes with running water between manholes as per specifications and finally commissioning the same. Depth of pipe laying - inverts varying as per slope and as provided in drawing. (For Soil, Waste). EXTERNAL DRAINAGE WORK. 200 mm diameter |
| 122 | Supplying, testing and laying in position of HDPE Pipe (PE-63) working pressure 10 kg/sq.cm (SWR) over a bed of brick soling and 100 mm thick sand cushion bed and covered upto 100 mm above crown with sand, laid correct to line , slope and level, cleaning the pipes after laying, testing the pipes with running water between manholes as per specifications and finally commissioning the same. Depth of pipe laying - inverts varying as per slope and as provided in drawing. (For Soil, Waste). EXTERNAL DRAINAGE WORK. 250 mm diameter |
| 123 | Constructing brick masonry manhole in cement mortar 1:4 ( 1cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 90 cm deep including C.I. coverwith frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 124 | Extra for depth for manholes : size 90x80 cm, With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 125 | Extra for depth for manholes : ize 120x90 cm, With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 126 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality. H D - 20, Circular shape 560 mm internal diamete |
| 127 | Construction of brick masonry Surface drain for various depths including excavation, dewatering, backfilling and disposal of spoils as per relevant codes of practice with bottom PCC (1:2:4) 150 mm thick with stone chips, one brick thickness of wall upto 600 mm depth. Wall to be plastered inside and pointed outside as per specifications with cement mortar (1:4), polypropylene moulded foot rests to be inserted @ 300 mm on centres vertically. Top of pit to be covered with D.I. / FRP cover and frame (load bearing capacity of 45 MT). PVC sheet is to be laid below the PCC and over the BFS layer and design as per the recommendation of the structural engineer. 200mm wide |
| 128 | Supply, installation testing & commissioning of brass forged body ball valves PN 1.6 screwed with SS/brass ball and spindle and teflon seats, complete with special supports and required flanges, nut, bolts complete. 20 mm dia |
| 129 | Supply, installation testing & commissioning of brass forged body ball valves PN 1.6 screwed with SS/brass ball and spindle and teflon seats, complete with special supports and required flanges, nut, bolts complete. 25 mm dia |
| 130 | Supply, installation testing & commissioning of brass forged body ball valves PN 1.6 screwed with SS/brass ball and spindle and teflon seats, complete with special supports and required flanges, nut, bolts complete. 32 mm dia |
| 131 | Supply, installation testing & commissioning of brass forged body ball valves PN 1.6 screwed with SS/brass ball and spindle and teflon seats, complete with special supports and required flanges, nut, bolts complete. 40 mm dia |
| 132 | Supply, installation testing & commissioning of brass forged body ball valves PN 1.6 screwed with SS/brass ball and spindle and teflon seats, complete with special supports and required flanges, nut, bolts complete. 50 mm dia |
| 133 | Installation, Fitting & testing of PVC Tripple layer overhead water storage tanks of the approved quality( for Domestic Water) and of the following capacity including making solid supported base as per instructions & doing all connections, interlocks, valves, drain, overflow, level control etc as required to make the work complete in all respects. Size and Height as indicated in drawing. 3 Layer PVC Tank (Domestic Water OHR, CAPCITY -3000 LTR) |
| 134 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1 with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials (v) For 100 users with SAIL/ TATA/RINL |
| 135 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials.With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. (SAIL/TATA/RINL) |
| 136 | Stamp Concrete Providing, laying & compacting freshly mixed M25 grade plain / reinforced cement concrete (blended either with Fly Ash or GGBS) along with addition of 900 gm of polypropylene (PP) fibers considering a concrete layer of an average thickness of 75 mm and as per directions of the Engineer-in-Charge.Finished slope to be provided as per relevant drawings. (Cost of reinforcement for stamped flooring is not included in this item which will be paid separately). Applying stamping finish to the top surface of freshly laid plain / reinforced cement concrete of M25 grade in porticos, sidewalks, driveways, pool decks and open yards as per direction of the Engineer-in-charge. The process shall include the following: - a)The concrete shall be placed and screeded to the finished grade and floated to a uniform surface by using standard finishing techniques. The approved colour hardener @ 3.0 Kg/sqm shall be applied evenly to the surface of the fresh concrete by the dry shake method by sprinkling in two or more shakes, floated after each shake and trowelled only after the final floating. The approved release agent @ 0.19 Kg/sqm shall be applied evenly to the trowelled surface before stamping or the said release agent can be applied to the flexible polyurethane stamp moulds of approved design and in required sizes to achieve final stamped pattern. These stampings shall be placed on the surface of concrete in three to four pieces at a time and tapped gently with rammers of sufficient size & weight to leave proper stamp marks and the process repeated for the remaining concrete surface till the whole surface to be stamped is completed within the time while concrete is in plastic stage of setting. b)After stamping, the curing shall be done as per manufacturer's specifications. After initial curing, the imprinted joints shall be grouted using cement slurry mixed with colour hardener as per the requirement. The surface shall be sealed by applying acrylic based sealer not less than 0.25 litre/sqm on finished surface. c)The construction joints shall be provided by groove cutting of size 4mm X 20mm in panel size of 3m X 3m or lesser as per the site conditions and filling the same with 10mm baker rod and providing and laying Polysulphide based joint sealer of approved make as per manufacturer's specifications and finished by applying Polyurethane resin based top protective clear coat of minimum 80 micron applied with rollers on properly cured and dry clean surface.(Brand: Ultratech/ACC) |
| 137 | 100 mm thick interlocking designer concrete paver block M-50 grade for hightraffic zone, bus terminus, industrial complex, mandi houses etc. as per IS: 156582006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of sand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in-Charge |
| 138 | 80 mm thick interlocking designer concrete paver block M-40 grade for medium-traffic zone & utility cuts on arterial roads etc. as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of sand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in-Charge.Colour Decorative |
| 139 | ACP wrapping: 3.5mm exterior grade designer alluminium composite panel as approved by EIC (Alu Decor/Interia/Pratap Bond) 1.5mm aluminium section with micron quality powder coating. 38 X 25 almnm tube. 38 X 25mm joining angles. 12 x 12mm joining angles. 50 x 50mm MS bracket. MS & SS anchor bolt. MS Fastnut. SS screws. Weather coat silicone sealant. |
| 140 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Frame size 65 x 100 mm |
| 141 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick |
| 142 | Dismantaling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within GRSE Premises. |
| 143 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. |
| 144 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed including stacking of steel bars |
| 145 | Dismantling artificial stone flooring upto 50 mm.thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof |
| 146 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 147 | Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. |
| 148 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge |
| 149 | Suppling, fitting and fixing Wall mounted water closet of white glazed vitreous chinaware of approved make and brand in position complete with necessary nut and boalts (Equivalent to Code No. 20061 or 92065 & Model Studio or Rubbic of Hindware or equivalent.) |
| 150 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P.hinges, rubber buffer and brass screws complete. Plastic (hallow type) white |
| 151 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming toI.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. |
| 152 | Supplying, fitting and fixing shower of approved brand and make. Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar). |
| 153 | Supplying and laying chequered tiles of any shade & of approved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, footpath etc. including necessary underlay 25 mm thick [avg] cement mortar (1:3) complete in all respect with all labour and materials. [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling] Red Variety (i) 25 mm. thick |
| 154 | M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof ii) for trusses spanning above 20.00 m and up to 30 .00m |
| 155 | Supply, fbrication fitting & fixing of lettering made of MS plate of thickness as approved by EIC. Matter either in English/Hindi/Bengali/all along with logo. This work includes cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as , labour insurance charges etc. (Note: Measurement will be taken on the basis of area of each letter (either in square or rectangular and payment will be made on weight of that area in MT) |
| 156 | Supplying , fitting and fixing single skin color coated trapezoidal profile for wall cladding, Roof shall be made of 0.45mm BMT (Base Metal Thickness) 0.50mm TCT ( Total Coated Thickness excluding paint), G550 ( minimum 550 yield strength), of Zincalume metallic coating (IS15965) with high Solar Reflectance Index (SRI) value for better cooling as per thermatch technology, 1000-1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove & return leg. The steel sheet shall be fastened with 40 micron zinc coated or 25 micron zinc-tin alloy coated, hex- head, self-drilling screw as per IS 3566-2002 class 3 fastener. The base steel shall be coated with zinc-aluminum alloy Zincalume (AZ150)(i.e, 55% Al, 43.4% Zinc, 1.6% Si) minimum of 150g/m2 coating total on both sides, pre-painted with colorbond XRW (exterior roofing, walling) paint system of 35 micron super Durable Polyester paint (SDP) with stable inorganic pigment with no lead contents confirming IS15965. The sheet shall be free from defects and have brand marking of the manufacturer giving product details on the back of the sheet at regular interval confirming genuinity of the material. In Roof, Ridge, valley and Wall with 0.50 mm thick sheet )( 60% payment will be released on recive of the Zn-Al alloy sheet inside the GRSE premises along with sbsequent clearance from engaging dept.) |
| 157 | Applying two coats of anti corrosive EPOXY paint (black) of approved make and brand to MS section only after preparing the surface by rough sand blasting. |
| 158 | ELECTRICAL WORK |
| 159 | W I R I N G: Supplying, installation, Testing & Commissioning of 22 watt LED surface mounted Batten light of Powder coated die cast /Extruded aluminum Body (Thickness ≥ 1.20 mm) body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/ 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) 135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer[1]in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). |
| 160 | Supplying and fixing brass batten/ angle holder including connection etc. as required |
| 161 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 162 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 163 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 164 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep |
| 165 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 166 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required 100 mm X 100 mm X 60 mm deep |
| 167 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required 150 mm X 75 mm X 60 mm deep |
| 168 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required 180 mm X 100 mm X 60 mm deep |
| 169 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required 200 mm X 150 mm X 60 mm deep |
| 170 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required 200 mm X 250 mm X 100 mm deep |
| 171 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as require: 20 mm |
| 172 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as require:25 mm |
| 173 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as require:32 mm |
| 174 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 175 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 176 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 177 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 178 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wir |
| 179 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 180 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
| 181 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 182 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 183 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] Average run 5 mtr |
| 184 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] Average run 6 mtr |
| 185 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] Average run 8 mtr |
| 186 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] Average run 9 mtr |
| 187 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] Average run 10 mtr |
| 188 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] Average run 11 mtr |
| 189 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] Average run 12 mtr |
| 190 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 191 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 192 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 193 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as require 1 or 2 Module (75mmX75mm) |
| 194 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as require 3 Module (100mmX75mm) |
| 195 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as require 4 Module (125mmX75mm) |
| 196 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as require 6 Module (200mmX75mm) |
| 197 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as require 8 Module (125mmX125mm) |
| 198 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as require 12 Module (200mmX150mm) |
| 199 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 200 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch |
| 201 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet |
| 202 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 203 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 204 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required |
| 205 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 206 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required |
| 207 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 208 | MCCB, MCB & DB’S:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole |
| 209 | MCCB, MCB & DB’S:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Double pole |
| 210 | MCCB, MCB & DB’S:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Triple pole |
| 211 | MCCB, MCB & DB’S:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Triple pole and neutral |
| 212 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 100 A,30KA,FP MCCB |
| 213 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 125 A,36KA,FP MCCB |
| 214 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 200 A,36KA,FP MCCB |
| 215 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way Double door |
| 216 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double door |
| 217 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door |
| 218 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4 + 36), Double door |
| 219 | Supplying and fixing 12 way double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment:Make Legrand |
| 220 | Supplying and fixing following 12 way , Double door way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 221 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required For 4 way, Double door TPN MCBDB |
| 222 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required For 8 way, Double door TPN MCBDB |
| 223 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 224 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 225 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required |
| 226 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required |
| 227 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Upto 35 sq. mm |
| 228 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Above 35 sq. mm and upto 95 sq. mm |
| 229 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Above 95 sq. mm and upto 185 sq. mm |
| 230 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm |
| 231 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 35 sq. mm and upto 95 sq. mm |
| 232 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm |
| 233 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required Upto 35 sq. mm |
| 234 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required Above 35 sq. mm and upto 95 sq. mm |
| 235 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required Above 95 sq. mm and upto 185 sq. mm |
| 236 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 237 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 238 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 239 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 240 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 241 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 242 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 243 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required |
| 244 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 100 mm dia |
| 245 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 150 mm dia |
| 246 | Supplying and installing following size of perforated painted with powder coating GI cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness |
| 247 | Supplying and installing following size of perforated painted with powder coating GI cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 200 mm width X 50 mm depth X 1.6 mm thickness |
| 248 | Supplying and installing following size of perforated painted with powder coating GI cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 62.5 mm depth X 2.0 mm thickness |
| 249 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 250 | Supplying and installing following size of perforated painted with powder coating GI. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 150 mm width X 50 mm depth X 1.6 mm thickness |
| 251 | Supplying and installing following size of perforated painted with powder coating GI. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 200 mm width X 50 mm depth X 1.6 mm thickness |
| 252 | Supplying and installing following size of perforated painted with powder coating GI. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 300 mm width X 62.5 mm depth X 2.0 mm thickness |
| 253 | 450 mm width X 62.5 mm depth X 2.0 mm thickness Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 254 | Supplying and installing following size of perforated painted with powder coating G I. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 100 mm width X 50 mm depth X 1.6 mm thickness |
| 255 | Supplying and installing following size of perforated painted with powder coating G I. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 200 mm width X 50 mm depth X 1.6 mm thickness |
| 256 | Supplying and installing following size of perforated painted with powder coating G I. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 300 mm width X 62.5 mm depth X 2.0 mm thickness |
| 257 | Supplying and installing following size of perforated painted with powder coating G I. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 258 | CABLE JOINTING & END TERMINATION:Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 2 X 6 sq. mm (19mm) |
| 259 | CABLE JOINTING & END TERMINATION:Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 X 10 sq. mm (25mm) |
| 260 | CABLE JOINTING & END TERMINATION:Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 X 16 sq. mm (28mm) |
| 261 | CABLE JOINTING & END TERMINATION:Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 3½ X 25 sq. mm (28mm) |
| 262 | CABLE JOINTING & END TERMINATION:Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 3½ X 50 sq. mm (35mm) |
| 263 | CABLE JOINTING & END TERMINATION:Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 3½ X 70 sq. mm (38mm) |
| 264 | CABLE JOINTING & END TERMINATION:Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 3½ X 120 sq. mm (45mm) |
| 265 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 266 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 267 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 268 | Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. |
| 269 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 270 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 271 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 272 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages 8 SWG |
| 273 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 274 | S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1) |
| 275 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required |
| 276 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 277 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 278 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 279 | Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 280 | Supplying, installation, Testing & Commissioning of 200 watt Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 VoltAC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junctiontemperature shall not rise above 90°C). |
| 281 | Supply, Installation, Testing and Commissioning of 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS :374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req |
| 282 | Supply of following size L.T. cable, working voltage 1.1 KV grade, heavy duty XLPE insulated, armoured, screened, stranded, Al distribution power conductor cable. MAKE POLYCAB. or equivqlent model GLOSTER/R.R/ HAVELLS as per direction of EIC. 3.5C, 120 sqmm. |
| 283 | Supply of following size L.T. cable, working voltage 1.1 KV grade, heavy duty XLPE insulated, armoured, screened, stranded, Al distribution power conductor cable. MAKE POLYCAB. or equivqlent model GLOSTER/R.R/ HAVELLS as per direction of EIC. 3.5C, 70 sqmm. |
| 284 | Supply of following size L.T. cable, working voltage 1.1 KV grade, heavy duty XLPE insulated, armoured, screened, stranded, Al distribution power conductor cable. MAKE POLYCAB. or equivqlent model GLOSTER/R.R/ HAVELLS as per direction of EIC. 3.5C, 50 sqmm. |
| 285 | Supply of following size L.T. cable, working voltage 1.1 KV grade, heavy duty XLPE insulated, armoured, screened, stranded, Al distribution power conductor cable. MAKE POLYCAB. or equivqlent model GLOSTER/R.R/ HAVELLS as per direction of EIC. 3.5C, 25 sqmm. |
| 286 | Supply of following size L.T. cable, working voltage 1.1 KV grade, heavy duty XLPE insulated, armoured, screened, stranded, Al distribution power conductor cable. MAKE POLYCAB. or equivqlent model GLOSTER/R.R/ HAVELLS as per direction of EIC. 4C, 16 sqmm. |
| 287 | Supply of following size L.T. cable, working voltage 1.1 KV grade, heavy duty XLPE insulated, armoured, screened, stranded, Al distribution power conductor cable. MAKE POLYCAB. or equivqlent model GLOSTER/R.R/ HAVELLS as per direction of EIC. 4C, 10 sqmm. |
| 288 | Supply of following size L.T. cable, working voltage 1.1 KV grade, heavy duty XLPE insulated, armoured, screened, stranded, COPPER distribution power conductor cable. 4C, 10 sqmm. CU |
| 289 | Electromechanical DP/4P RCBOs used as (DP,TPN & FP RCBOs)(In accordance with IS 12640-2 & IEC 61009-1) 240 V/415 V, 50 Hz, with 10 kA ,short circuit capacity. (30mA). MAKE L&T. or equivqlent model legrand, HAVELLS as per direction of EIC. 32 A, FP |
| 290 | Electromechanical DP/4P RCBOs used as (DP,TPN & FP RCBOs)(In accordance with IS 12640-2 & IEC 61009-1) 240 V/415 V, 50 Hz, with 10 kA ,short circuit capacity. (30mA). MAKE L&T. or equivqlent model legrand, HAVELLS as per direction of EIC. 32 A, DP |
| 291 | Electromechanical DP/4P RCBOs used as (DP,TPN & FP RCBOs)(In accordance with IS 12640-2 & IEC 61009-1) 240 V/415 V, 50 Hz, with 10 kA ,short circuit capacity. (30mA). MAKE L&T. or equivqlent model legrand, HAVELLS as per direction of EIC. 63 A, FP |
| 292 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection . MAKE L&T. or equivqlent model legrand, HAVELLS as per direction of EIC. 40A, 415V, FP MCB |
| 293 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection . MAKE L&T. or equivqlent model legrand, HAVELLS as per direction of EIC. 63A, 415V, FP MCB |
| 294 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection . MAKE L&T. or equivqlent model legrand, HAVELLS as per direction of EIC. 40A, 415V, TP MCB |
| 295 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection . MAKE L&T. or equivqlent model legrand, HAVELLS as per direction of EIC. 63A, 415V, TP MCB |
| 296 | Supplying, installation, Testing & Commissioning of 36 watt LED Panel light 2x2 ft., of Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching)<3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). MAKE - PHILIPS /BAJAJ / HAVELLS as per direction of EIC. |
| 297 | Supplying, installation, Testing & Commissioning of 18 watt LED Panel light 2x2 ft., of Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching)<3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). MAKE -PHILIPS /BAJAJ / HAVELLS as per direction of EIC. |
| 298 | Supplying, installation, Testing & Commissioning of 22 watt LED Panel light 2x2 ft., of Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching)<3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). MAKE - PHILIPS /BAJAJ / HAVELLS as per direction of EIC. |
| 299 | Supplying & fixing 450MM Airboll HI speed Wall Fan Make- HAVELLS or EQU ORIENT/USHA/POLAR as per direction of EIC. |
| 300 | Supplying & fixing Turbo Force 300MM Exhaust Fan Make- HAVELLS or EQU ORIENT/USHA/POLAR as per direction of EIC. |
| 301 | Main TTA LT Panel : • The switchboards shall be based on IEC 61439 OEM certified design, supplied by OEM authorized franchises. • The LV panel manufacturer shall be ISO 9001 / 9002 certified. • The LV panel shall be complete design verified assembly as per IEC 61439 – 1&2. • The enclosures shall be designed to take care of normal stress as well as abnormal electro-mechanical stress due to short circuit conditions. • The enclosure protection shall not be less than IP42 unless other specified in BOQ and IP2X on opening of the doors. • The LV panels shall be of aesthetic design, dust, damp & vermin proof. • The Switchboards shall be metal clad totally enclosed, floor mounted freestanding, fully compartmentalized bolted type of modular extensible design suitable for indoor mounting. • Intrinsic load bearing member shall be used as per design verified assembly and should have min. thickness of 2 mm. Non load bearing members shall be minimum 1.6mm thick. • The LV panel shall have integral base frame. • Switchboard shall be readily extendible on both sides by addition of vertical sections after removal of the end covers. • The LV panel shall be of min. form 4B construction except for MCB feeders. • The LV Panel shall comply with the Technical Data Sheet, SLD, and Feeder List as specified by the customer SWITCHBOARD DIMENSIONAL LIMITATIONS • A base channel 50 mm height shall be provided at the bottom. • The LV panel shall have provision to provide different panels heights from 1800 to 2400 mm to suit site varied conditions. • The height of the operating handle, push buttons etc. shall be restricted between 300 mm to 1800 mm from finished floor level. SWITCHBOARD COMPARTMENTALIZATION • For compartmentalized switchboards, separate totally enclosed compartments shall be provided for horizontal bus bars, vertical bus bars, ACBs, MCCBs and cable alleys. • Hinged lockable doors for each separate compartment shall be provided and duly interlocked with the breaker in \\"ON\\" and \\"OFF\\" position. • For all Circuit Breakers separate and adequate compartments shall be provided for accommodating instruments, indicating lamps, control contactors and control MCB etc. These shall be accessible for testing and maintenance without any danger of accidental contact with live parts of the circuit breaker, bus bars and connections. • Cable compartments shall be of adequate size for easy termination of all incoming and outgoing cables entering from bottom or top. SWITCHBOARD BUS BARS • The busbars rating shall be as per tested design, complying to IEC 61439. • The busbars shall be of rectangular cross sections suitable for full load current. • The ratings and configuration of bus bars shall be as per type tested design of OEM • The busbars shall be colour coded using identifying colour rings at regular interval. Red, Yellow & Blue colour shall be used for phases & Black for neutral for each shipping section of panels .The earth Busbar shall be identified with Green color rings at regular intervals. EARTHING • One earthing terminal shall be provided on each side of switchboard. • An earth bar size must be at least 1: 6 x 50 sq mm Aluminium (same can be provided with GI or Cu also, if required). • Each unit shall be constructed to ensure satisfactory electrical continuity between all metal parts which are not intended to be alive. • Door earthing shall be provided for all doors by multi-strand copper wires. WIRING • All wiring for relays and meters shall be with PVC insulated copper conductor wires. • The wiring shall be coded and labelled with approved ferrules for identification. • The minimum size of copper conductor control wires shall be 2.5 sq. mm. • Identification ferrules shall use at both end of wires. PAINTING AND FINISHING • Sheet steel used in the fabrication of switchboards shall undergo a rigorous cleaning and surface treatment seven tank process comprising of alkaline degreasing, descaling in dilute sulphuric acid and a recognised phosphating process after which a coat of primer paint with the final paint shall be applied over the treated surface. Final paint coat of oven baked powder coating, of minimum 50 micron thickness shall then be provided. Incoming Type-2, Surge protection device with HRC FUSE 80kA, 32A with rated Imax 40kA. 1 Nos 630A 4P electrically operated, motorised -cum-manual spring charged withdrawable type MCCB of rated service voltage upto 690V, 50 HZ with manual push buttons, indications, current sensors, CTs etc confoirming to the spedfication and as follows: Icu-50 KA (at 415V, 50 HZ), Ics=100% Icu Microprocessor based S/C, E/F & O/C releases. Rated impulse withstand voltage not less than 12 KV for main conducting paths. Auxiliary contacts, shunt trip coils etc. 1 sets CT Operated Digital Multifunction Meter having Cl-1 accuracy and showing (A, V, F, Maximum Demand). 1 Set (3 Nos/Set)600/5-5A Dual Core cast resin type Current Transformer of CL-5P10 for protection and CL-1 for metering with 15VA burden each 1 sets (3 nos each) RYB cluster type LED phase indlcation lamps. 1 sets - ON/OFF/TRIP cluster type LED indication lamps. BUSBAR 1 sets -800A, 415V, 50HZ, symmetrical continuous rated Aluminium busbars mounted on suitable hylam/ DMC/SMC insulators/supports with proper graded colour coded heat shrinkable PVC sleeves. OUTGOING a)2Nos 160A, 4P manualy operated type MCCB of rated service voltage upto 690V, 50 HZ . Icu-25KA (at 415V, 50 HZ), Ics=100% Icu Thermo-magnetic based S/C, O/C releases. b)2Nos 125A, 4P manualy operated type MCCB of rated service voltage upto 690V, 50 HZ Icu-25KA (at 415V, 50 HZ), Ics=100% Icu Thermo-magnetic based S/C & O/C releases. c)2Nos 100A, 4P manualy operated type MCCB of rated service voltage upto 690V, 50 HZ Icu-25KA (at 415V, 50 HZ), Ics=100% Icu Thermo-magnetic based S/C & O/C releases. d)7No. - 63A 4P MCB (10kA) e)1No. - 32A 4P MCB (10kA) Complete Board as stated above. |
| 302 | Supplying, Installation, Testing & Commissioning with 1 years guarantee/DLP & post DLP 2 year comprehensive AMC of 13 passenger (884kg) capacity passenger Machine room less (MRL) lift with regenerative drive CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended up to date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including all other equipment and accessories complete as required:- i) Speed-1 MPS (ii) Floors-5 (G+3) (iii) Travel -14 Meters (approx.) (iv) Stops & opening- 4 stops and 4 openings (v) Controller: A.C. variable voltage & variable frequency (vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as required. vii) Operation: Microprocessor based single automatic push button/simplex selective collective/duplex collective selective with/without attendant. (viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system (ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless-steel decorative ceiling with fans (indirect throw) and LED fitting. (x) The car flooring should be smooth and antiskid as approved by engineer-in-charge. (xi) Type of doors (a) Car: Power operated, centre opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish). (b) Landing doors: stainless steel scratch proof. (xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car. (xiii) Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator. (xiv) Closed loop Control System, protection against power fluctuation, self-diagnostic control, Landing doors 2 hours Fire rated, Overload detection and protection, Over speed Governor, Dot Matrix LED D & P Indicators In Car & Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder. (xv) The lift doors shall have a vision panel to enable persons with hearing impairment to signal for help or assistance in the event of an emergency. (xvi) An appropriate technological support be provided (Through emergency messaging |services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness. (xvii) Including power cable,MCCB,signage,Earthing etc required for satisfactory performance in all respect of lift |
| 303 | Supplying, Installation, Testing & Commissioning with 1 years guarantee/DLP & post DLP 2 year comprehensive AMC of 2 Ton Industrial Monorail Hoist Crane (W-5mtrs, H.3mtrs) with Connection (Including cable ,Crane control panel,Earthing ,Rail Supply & rail installation,with remote & pendent both control,hooter and also load test by WB Factory inspector with satisfactory performance of crane in all respect ) |
| 304 | Supply, Installation, Testing & commissioning of Tilting Type Rice Boiler, For Rice/ Dal Boling Capacity 60-220 Ltrs Including power cable ,MCCB (3nos) with 2yrs AMC |
| 305 | Supply, Installation & Commissioning of Centrifugal Air Blower System as per below specification: Blower Type Subject : Centrifugal Air Blower (sisw) Air flow Capacity ; 35,000 CMH (20,588 CFM) Static Pressure ;160 mmwg Temperature ; 250 °C Inlet Velocity ;26 m/sec Blower Outlet ; 700*525 mm Blower Inlet ;700 Power : 40 H.P. (30 kw) Motor Speed : 1440 Rpm Blower Speed : 1200 Rpm Blower Pully : 180*3sp*65 mm Motor Pully : 165*3sp*55 mm Bearing : 6213 (SKF 65*120*23) Driven Type : Belt Drive Casing Material : Mild Steel Impeller Type : Backward Curved Bearing Type : Deep Groove Ball Bearing Make : SKF/FAG/NBC/KOYO (as per availability) Mounting : Both Side plummer Block Housing Lubrication : Grease packed (Lithium Based, High Temp) Bore Diameter (d) : 65 mm Outer Diameter (D) : 120 mm Width (B) : 23 mm Dynamic Load Capacity (C) : 75 kiloNewton Static Load Capacity (Co) : 51 kiloNewton Balancing :Dynamic balancing. Paint/Coating : Epoxy primer + PU/ HR Paint (for corrosion resistance) Base Frame : Heavy-duty fabricated Mild Steel Structure. Mounting : Blower and Motor mounted on common base frame with alignment provision. Vibration Isolator : High-quality rubber/ bush type vibration isolators pads provide between base frame and foundation |
| 306 | FIRE PROTECTION WORK |
| 307 | Internal Hydrant Riser & Terrace Ring : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia |
| 308 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/ stainless steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal/ Stainless steel cap and chain as required: Single Headed Gun metal |
| 309 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun metal |
| 310 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : |
| 311 | Supplying and fixing first aid hose reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced ) type-2 as per IS 12585 20 mm nominal internal dia gun metal globe valve and nozzle Drum and brackets for fixing the equipments on wall Connections from riser with 25mm dia stop gun metal valve & MS Pipe and socket. 40m |
| 312 | Providing and fixing anodised glazed door shutter and frame of approved sections for Fire hose cabinet with dash fasteners ( frame fabricated from 40 x 40 mm and shutter ) 600 mm high x 300mm wide x 750 mm height ( customizable) with locking arrangement, 4mm thick glass with beading including all accessories, complete as per drawing and as directed. The letters “ HOSE CABINET” to be painted in red colour on the box complete in all respects and Lock and Key arrangement with hammer shall be provided. |
| 313 | Supply, fixing and commissioning of first aid box complete with fixing brackets and all necessary accessories, tools etc. |
| 314 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required |
| 315 | Steel buckets with Pole Mounted stand filled with sand |
| 316 | 25mm Air release valve as per IS:14845 ISI Marked |
| 317 | Supplying, fixing, testing and commissioning of double flaned sluice valve of rating PN 1.6 with non rising spindle, bronze/ gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required: |
| 318 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 200 mm dia (wall thickness 6.3 mm) |
| 319 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 150 mm dia |
| 320 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 100 mm dia |
| 321 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 80 mm dia |
| 322 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 65 mm dia |
| 323 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 50 mm dia |
| 324 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:40 mm dia |
| 325 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 32 mm dia |
| 326 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 25 mm dia |
| 327 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required (For Drain Pipe). 50 mm dia |
| 328 | Supplying, installing, testing and commissioning of Bronze/Brass body ball valves , Screwed Female Ends to IS 554 / BS 21 / ISO 7, Full Bore, Two Piece Design, Quarter Turn, Lever Operated, Provided with Stainless Steel Ball, Premium Quality PTFE Gland Packing and Seating conforming to : Test Pressure (Hydrostatic) : Shell : 20 kg/cm²g (285 psig) Minimum Seat : 13.5 kg/cm²g (192 psig) Minimum. 50 mm dia |
| 329 | Supplying, Installing, testing and commissioning of butterfly valves rating with bronze / gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes: 150 mm |
| 330 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Pendent |
| 331 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Upright |
| 332 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Horizontal Sidewall Sprinkler |
| 333 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 141 degree centigrade with required accessories : Pendent |
| 334 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 141 degree centigrade with required accessories : Upright |
| 335 | Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150 mm dia |
| 336 | Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required: 1500 mm |
| 337 | Providing and fixing flow switch in following sizes MS Pipe including connection etc as required. 100 mm dia |
| 338 | Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required. |
| 339 | 25mm Air release valve as per IS:14845 ISI Marked |
| 340 | PVC TANKS Providing & fixing PVC overhead water storage tanks of the approved quality, & of the following capacity including making solid supported base as per instructions & doing all connections, interlocks, valves, drain, overflow, level control etc as required to make the work complete in all respects. Size and Height as indicated in drawing. 10 KL, Note: As per clients recommendation only. Preferrable to use RCC tank which comes under civil BoQ |
| 341 | Supplying, installing and commissioning Portable Fire extinguishers of following type & capacity. Carbon-di-oxide Gas Type Fire Extinguisher 4.5 Kgs, squeeze Grip, Discharge Time less than 10 Secs, Controllable discharge mechanism with nozzle, bend, Hose and wall mounting bracket etc., Applicable on Class B&C Fire, B Rating 21B, Can Construction : Hot Spinning / Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Seamless Cylinder, External Coating of Can : Spray Painting, Sheet metal thickness : 4.5MM, ISI Approved as per IS:2878:2004 |
| 342 | ABC Powder 6 Kg Fire Extinguisher containing Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, fitted with discharge hose, wall mounting bracket etc., Discharge Time less than 15 Secs, Controllable discharge mechanism, Range minimum 4 Meters, applicable on Class A,B,C and electrically started Fire, A Rating- 8A, B Rating 34B, Can Construction : Deep drawn & Co2 Mig welded, Valve Construction : Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy Polyester Powder coating, Sheet metal thickness: 1.60MM, ISI approved as per IS:15683:2006 |
| 343 | Stainless steel K type fire extinguisher of capacity 4 kg assigned to extinguish Class F fire for use in kitchen areas with a discharge range of 3 meters and working pressure of 15 bar operating at a temperature -10C to +60C conforming to IS 15683 |
| 344 | 45 (Ltr) Mechanical Foam Wheeled Fire Extinguisher (AFFF) Based, Operating Temperature Range (+) 5 to (+) 55oC |
| 345 | Modular ABC type (Automatic Roof Type) Fire Extinguisher - 5 kg for LT Panel room , and Fire Pump Room. Charge Pressure : 15kgf /cm2 Test Pressure : 35kgf/cm, Bulb Temperature : 68C |
| 346 | AFFF Foam Type fire extinguisher 9 Lt Capacity, Stored Pressure Type, Pressure Gauge, Discharge Time less than 60 Secs, with hose and brackets, Controllable discharge mechanism, Range minimum 6 Meters, applicable on Class A,B, A Rating 13A, B Rating 55B, Can Construction : Deep drawn & CO2 Mig welded, Valve Construction : Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy Polyester Powder coating, Sheet metal thickness : 2.0MM, ISI Approved as per IS 15683:2006 |
| 347 | Supplying, installation, testing and commissioning of Electric driven Main Fire Pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads 2850 lpm at 70 m Head Note: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point |
| 348 | Supplying, installation, testing and commissioning of diesel engine driven main fire pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) (b) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal as required. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. (d) M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. (e) Suitable cement concrete foundation duly plastered and with anti vibration pads. 2850 lpm at 70 m Head Note: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point |
| 349 | Supplying, installation, testing and commissioning of electric driven pressurisation pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump). Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class- 'F' insulation, conforming to IS-12615: 2018. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 300 lpm at 70 m Head |
| 350 | Supplying, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel |
| 351 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 352 | Supplying, installation, testing & commissioning of response indicator on surface / recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 353 | Supplying, installation, testing & commissioning. of fault isolator complete with base as required. |
| 354 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. |
| 355 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 356 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
| 357 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 358 | Supplying, installation, testing & commissioning of addressable Monitor modules complete with base as required. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail