| 1 | Civil works |
| 2 | Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer in charge. |
| 3 | 15.1.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 4 | 15.1.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 5 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-in charge. |
| 6 | 15.6.1 In Cement mortar |
| 7 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 8 | 15.25.1 G.S. Sheet |
| 9 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - -All work upto plinth level: |
| 11 | 4.1.6 1:4:8 ( 1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 12 | Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: |
| 13 | 6.8.1 Cement mortar 1 : 3 (1 cement : 3 coarse sand) |
| 14 | Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position : |
| 15 | Local best quality Uningthou wood |
| 16 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. |
| 17 | 11.32.1 Size of Tile 600 x 600 mm |
| 18 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, in skirting, riser of steps, over 20mm thick cement mortar 1:3 (1 cement: 3 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 19 | 11.36.1 Size of Tile 500 x 500 mm |
| 20 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 21 | 9.63.1 300x16 mm |
| 22 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 23 | 9.64.1 300x10 mm |
| 24 | Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 25 | 9.66.1 125 mm |
| 26 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: |
| 27 | 9.62.1 125x75x4 mm |
| 28 | Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (framework to be paid separately): |
| 29 | 12.22.2 White face insulating board |
| 30 | 12.22.2.1 12 mm thick |
| 31 | 12 mm cement plaster of mix |
| 32 | 13.4.1 1:4 (1 cement : 4 coarse sand) |
| 33 | 15 mm cement plaster on rough side of single or half brick wall of finished with a floating coat of neat mix |
| 34 | 13.8.1 1:3 (1 cement: 3 fine sand) |
| 35 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 36 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 37 | 13.31.1 Water thinnable cement primer |
| 38 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade |
| 39 | 13.29.1 New work (two or more coats) over and including priming coat with cement primer:- |
| 40 | Finishing walls with textured exterior paint of required shade : |
| 41 | 13.33.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 42 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: |
| 43 | Applying priming coat:- |
| 44 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: |
| 45 | 13.44.1 Two or more coats on new work |
| 46 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 47 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 48 | Internal work - Exposed on wall |
| 49 | 17.1.1 15 mm nominal outer dia Pipes |
| 50 | 17.1.4 32 mm nominal outer dia Pipes |
| 51 | Electrical works |
| 52 | Wiring for light point / Fan point/ Exhaust Fan ponit / Call bell point with 1.5mm2 PVC insulated copper conductor single core cable in pvc casing and capping with piano type switch, phenolic laminated sheet suitable size M.S. Box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc. as reqd. |
| 53 | 3. Group C |
| 54 | Wiring for circuit / sub- main wiring along with earth wire with ( the following sizes of ) PVC insulated copper conductor single core cable in PVC casing and capping etc as reqd. |
| 55 | 2. 2x2.5mm2 + 1x2.5mm2 earth wire |
| 56 | 3. 2x4mm2 + 1x4mm2 earth wire |
| 57 | 4. 2x6mm2 + 1x6mm2 earth wire |
| 58 | Fixing Items |
| 59 | S/F PVC box of size 101mmx178mm (Nominal size)/(4''x7'')PVC board on surface including P/F 3 pin 5/6 amp socket outlet and 5/6 amp piano type switch connection etc as reqd. |
| 60 | S/F PVC box of size 152mmx203mm (Nominal or size)/(6''x8'')PVC board on surface including P/F 6 pin 15/16 amp socket outlet and 15/16 amp piano type switch connection etc as reqd. |
| 61 | 76.2mmX76.2mm conical round plate |
| 62 | S/Fbrass batten /angle holder i/c conection etc as reqd. |
| 63 | S/F 3 pin 5 amp ceiling rose on the existing junction box /wooden block i/c connection etc as reqd |
| 64 | S/F 20W CFL lamp. |
| 65 | Supplying & fixing stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc as reqd. |
| 66 | S/F 48'' Sweep (1200mm) A.C ceilling fan complete with down rod canopy, 3 (three) blades but without regulator etc as reqd.( Make Bajaj/Usha or simillar) |
| 67 | S/F 305mm sweep exhaust fan complete with all accessories i/c connection etc as reqd. |
| 68 | S/F 8 way (2+8 way) single door single pole and neutral , prewired, sheet steel MCB distribution board, 240 V on surface complete with loose wire box, terminal blocks, tinned copper copper bus bar neutral link, earth bar , din bar, detachable gland plate , interconnection , including powder coated painting earthing etc. as reqd. ( but without MCB/RCCB/Isolator). |
| 69 | Supplying and fixing 5 amp to 32amp rating 230 V 'B' series MCB for lighting and other load of ( following poles ) in the existing MCB DB complete with connection testing and commissioning etc as reqd. |
| 70 | 1. Single pole |
| 71 | S/F( following rating) double pole 240v isolator in the existing MCB DB complete with connection ,testing and commissioning as reqd. |
| 72 | 1. 40 amp |
| 73 | Supplying and fixing wall mounted metal board of welded construction with minimum 35mmx35mmx6mm angle iron frame work with 25mmx6mm flat iron as intermediate membersi/c painting etc as reqd. |
| 74 | Providing and fixings (following capacity TP & N) disconnector fuse switch unit inside the existing cubicle panel board with ISI marks HRC fuses including drilling holes in the cubicle panel board, making connection as reqd. |
| 75 | 63 amp TP&N |
| 76 | S+B38:G43/F Bus Bar chamber with 4 strips copper bus bar of length 300 mm suitable for 63 amp capacities complete with all accessories i/c connection earthing the body etc as reqd. |
| 77 | FLOOD LIGHT, HPFLP 100 W, LHEPARU17J101 Please Enable Macros to View BoQ information |