| 1 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 4 way (4 + 12), Double door |
| 2 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 3 | (a) Single pole |
| 4 | (b) Triple pole and neutral |
| 5 | Supply of PVC insulated PVC sheathed/XLPE power cable of 1.1KV grade of AL. conductor cable as reqd. confirming to ISI-7098 (part -1) 1988 with upto date amendment of the following sizes. |
| 6 | (a) 4x35 sq. mm armoured |
| 7 | (b) 4x25 sq. mm armoured |
| 8 | (c) 4x 16 sq mm armoured |
| 9 | (d) 2 x 10 sq mm armoured |
| 10 | (e) 4 x 6 sq mm armoured |
| 11 | (f) 2 x 6 sq mm armoured |
| 12 | Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. (a) Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 13 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.(a) Upto 35 sq. mm |
| 14 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required(a) 100 mm dia |
| 15 | Supplying and fixing Weatherproof Junction Box,(Size : 28cmX 21cm X 11cm) White Colour Fiber Reinforced Plastic junction box with hinged door along with supply and fixing connector terminals and 6 Amp c-curve SP MCB. |
| 16 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in allrespect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).(a) 45 watt |
| 17 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 18 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 19 | Supplying, installation testing and commissioning of 45 Watt LED post top luminaires in pressure die-cast aluminium housing with IP65, LEDs with lumen m efficacy noit less than 110 lm/W,colour temp 5700 K, THD (%) < 10, Polycarbonate diffuser in opal finish and fixing existing gate piler & dismantling the existing fitting etc at the site of work as required. |
| 20 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 21 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulatedand PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required |
| 22 | (a)4 X 35 sq. mm (32mm) |
| 23 | (b) 4 X 25 sq. mm (28mm) |
| 24 | (c) 4 X 16 sq. mm (28mm) |
| 25 | (d) 2 X 10 sq. mm (19mm) |
| 26 | (e) 4 x 6 sq mm (22 mm) |
| 27 | (f) 2 X 6 sq. mm (19mm) |
| 28 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time(LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not morethan the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cableand earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as perrequirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 29 | (a) 200 Watt |
| 30 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 40 A |
| 31 | Supplying and fixing FP sheet steel enclosure on surface/ recess complete with connections, testing and commissioning etc. as required. |
| 32 | Supplying / Installation / Testing / Commissioning of wall / floor mounted cubicle type control panel board of dust proof, weather proof of size 1150 X 1000 X 450 mm of 14 SWG Sheet with seprate compartment, factory finished painting with 9 tank process, locking arrangement complete with internal wiring with Aluminium bus bar strip of size 25 mm X 5 mm thick from bus bar to out going MCCB and copper wire of size 6 Sq mm from bus bar to MCB SPN with copper lugs / ferrous earth bolts, rubber gasket alongwith operating handle. The following mountings are to be fixed in the panel board. a) 100 Amp, 36 kA MCCB 4 pole b) 32 Amp , 10 kA C Curve MCB 4 pole 3 No. c) 250 A Aluminium bus bar of size 25 X 5 mm mounted on epoxy insulator with brass and nuts & bolts for 3 Phase 4 Wire with heat shrinking sleeve RYB & N (500 X 4 Nos.) - 1 Set |
| 33 | Supplying / Installation / Testing / Commissioning of wall / floor mounted cubicle type control panel board of dust proof, weather proof of size 1150 X 1000 X 450 mm of 14 SWG Sheet with seprate compartment, factory finished painting with 7 tank 5process, locking arrangement complete with internal wiring with Aluminium bus bar strip of size 25 mm X 5 mm thick from bus bar to out going MCCB and copper wire of size 6 Sq mm from bus bar to MCB SPN with copper lugs / ferrous earth bolts, rubber gasket alongwith operating handle. The following mountings are to be fixed in the panel board. a) 200 Amp, 25 kA MCCB 4 pole b) 100 Amp , 36 kA MCCB 4 pole 1 No. c) 32 A 4P 10 KA, C Curve MCB – 1 no. d) 32 A DP 10 KA C Curve MCB- 4 nos. e) 200A 415 volt, 4 pole change over f) CT 200 / 5 Amps range - 3 Nos g) Digital Ammeter -1 No. h) Digital Volt Meter - 1 No. i) Selector Switch - 2 Nos. h) Indicator lamp with toggle switch and 5 Amp fuse set - 3 Sets i) 250 A Aluminium bus bar of size 25 X 5 mm mounted on epoxy insulator with brass and nuts & bolts for 3 Phase 4 Wire with heat shrinking sleeve RYB & N (500 X 4 Nos.) - 1 Set |
| 34 | Deduct Scrap value including old panels, conduits, wiring, fittings, overhead line & other old unservicable electrical assesories Please Enable Macros to View BoQ information |