| 1 | DSR item No.40.6.25/6MPIPIRBullet CameraSupplying Installation Testing and Commissioning of 5/6MP IP IR Bullet Camera having following spcifications and features etc, (As per Complete Item No. 1 of the DNIT). |
| 2 | 5MP/6MP IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens outdoor Bullet Camera. |
| 3 | DSR Item No.40.11.1Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below ,(As per Complete Item No. 2 of the DNIT). |
| 4 | 32 Channel Network Video Recorder (NVR) having display split:- Main screen: 1/4/8/9/16/25/32(36), 2nd screen: 1/4/8/9/16 |
| 5 | DSR item No.40.12.2 Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. |
| 6 | 6TB (Terabytes) |
| 7 | DSR item No.39.3.1 Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 128Gbps and packet forwarding rate of 95Mpps or higher, 16K MAC table. Console Port, USB port,(As per Complete Item No. 4 of the DNIT). |
| 8 | 24 port PoE Layer2 Network Switch with PoE Supportof 370W or higher with each cooper port supporting 802.3at PoE+ min. |
| 9 | DSR item No.39.1.1 Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, (As per Complete Item No. 5 of the DNIT). |
| 10 | 8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting 802.3at PoE+. |
| 11 | DSR item no.39.26 Supply and fixing Outdoor Pole/ Wall mount 6U Rack, IP55, Front Door with Filter, Louver & Unique key Lock. 3 Socket PDU 5Amp - 1 No. Self adhesive thermal foam from inside. Hood For Air Inlet at front side.1U Cantilever Tray 250mmDepth, Gasket. Etc. complete as required. |
| 12 | DSR item no.39.23 Supply and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U' Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035,(As per Complete Item No. 7 of the DNIT). |
| 13 | 15U Rack |
| 14 | DSR item no.42.4.3 LED DisplaySupplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, Bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, (As per Complete Item No. 8 of the DNIT). |
| 15 | 55 inch or larger |
| 16 | DSR item no.26.1.1Online UPS - Input supply: Single Phase, Output Supply : Single Phase Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply.(As per Complete Item No. 9 of the DNIT). |
| 17 | 2 KVA |
| 18 | DSR item No.39.20.2 Supplying and drawing following core Multi mode Fiber Optic Cable having corrugated steel armoring, leser optimize 50/125 µm with HDPE jacket, LSZH (Low smoke Zero Halogen),(As per Complete Item No. 10 of the DNIT). |
| 19 | 12 Core Multi Mode Optical Fiber Cable Meter 87 |
| 20 | DSR item No. 39.6.1 Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required.(As per Complete Item No. 11 of the DNIT). |
| 21 | 1G SFP Single Mode/Multi Mode |
| 22 | DSR item No.39.22 Supply and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2mm with Mechanical specification Apex Offset < 50 µm,(As per Complete Item No. 12 of the DNIT). |
| 23 | Labour charges for horizontal boring 1 Mtr. Below ground level for laying of DWC pipe including cost of 2 Nos. pit digging and refilling complete in all respects to entire satisfaction of the Engineer-In-Charge of the work. |
| 24 | DSR item No.39.21 Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations,(As per Complete Item No. 14 of the DNIT). |
| 25 | 6PortLIU |
| 26 | 12PortLIU |
| 27 | DSR item No.39.12.1 Supplying, Installation, Testing and commissioning of following CAT6 Patch Cordshould have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D |
| 28 | CopperPatchCordsoflength1m(3ft) |
| 29 | DSR item No.39.11 Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 30 | S/E of 5 Mtr. long Hot dipped Galvanized pole of octagonal cross-section continuously tapered made out from high tensile steel of minimum thickness 3 mm complete with the base plate of minimum size 200mm x 200mm x 12mm alongwith inbuilt lockable junction box which should be operated with single key. The diameter across from the dimensions of the base and top should be minimum 130 mm and 70mm A/F (Across Face).,(As per Complete Item No. 17 of the DNIT). |
| 31 | Supply & laying of PVC copper wire 1.5 mm sq. 3 core round sheathed wire on existing surface with suitable clamps/ hanger etc. including making connection and petty material etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. The copper wire should be of Polycab/ L&T/ Havells/ Finolex/ R.R. Kables/ KEI make only. |
| 32 | SITC of Single Mode Media Converter 1X10/100/1000mbps Auto-Negotiation Rj45 port supporting auto-MDI/MDIX auto-negotiation of Half-Duplex/ Full-Duplex transfer mode. Make: HPE/ Zyxel/ Juniper/ TP Link/ D-Link only. |
| 33 | SITC of Optic Fiber Adopters should be suitable for single mode SC/SM fiber cable connectors and shall be fully compliance with latest industry standard. It shall be with snap/ latch mechanism. Optic fiber adopters. Make: R&M/ Panduit/ D-link only. |
| 34 | DSR item No.39.17.1 Supplying,drawing,Installation,Testing and commissioningof CAT6UTPLSZH23AWGTwistedPair Cableinexisting conduit/ on surface, Category 6 Unshielded Twisted Pair,(As per Complete Item No. 21 of the DNIT). |
| 35 | 1Runofcable |
| 36 | DSR Item No. 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 37 | 25 mm |
| 38 | DSR item No.15.16 SupplyingandlayingoffollowingsizeDWCHDPEpipeISI markedalongwithallaccessorieslikesocket,bend,couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioningandprotectivecoveringetc.,completeasrequired. |
| 39 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 40 | DSR item No.15.15 Supplying and laying of following sizeDWC HDPE pipe ISImarkedalongwithallaccessorieslikesocket,bend,couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 41 | 63 mm dia (OD-63 mm & ID-51 mm nominal) Please Enable Macros to View BoQ information |