| 1 | Earthwork inexcavation of foundation trenches or drains, inall sorts of soil (includingmixed soil but excluding laterite or sand stone) including removing, spreading or stacking the spoils with in a lead of 75m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm. |
| 2 | Filling in foundation or plinthby silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturationwith water, ramming complete including the cost of supply of sand. (payment to bemade on measurement of finished quantity) |
| 3 | Supplying and laying Polythene Sheet (150gm/ sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. |
| 4 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. |
| 5 | 125mm. Thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. |
| 6 | Plaster (towall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding / staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface], (ii) With 1:4 cement mortar, (b) 15 mm thick plaster |
| 7 | Supplying and laying true to lineand level vitrified tiles of approved brand (size not less than 600mmX600mmX10 mmthick) in floor, skirting etc. set in 20mm sand cement mortar (1:4) and 2mm thick cement slurry back side of tiles using cement @ 2.91Kg. / sqM or using polymerised adhesive (6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurryusing1.75Kgof cement per sqMbelow mortar only, joints grouted with admixture of white cement and colouring pigment to match with colourof tiles / epoxy grout material so f approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles usings of tanddry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e) I (I) With application slurry @1.75kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.mwhite cement for joint filling with pigment, (B) Light Colour |
| 8 | M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. i) For roof truss worksa) Span up to 12 Mtr |
| 9 | Supplying, fitting & fixing in position suspended false ceiling with frame work of aluminium hollow section of size 50mmX25mm (2.0mm thickness) combined with aluminium corner sof size38mmX25mm, suspended by aluminium hollow tube section of size 38mmX25mmhaving size of 600mmX600mm ceiling with aluminium composit panels (ACP)-Interior grade of thickness 3.0mm comprising of proctective film, polyester coating, primer, aluminiumcoil, adhesive film, polyethylenecoreagainwithonelayeradhesivefilm,aluminiumbottomcoating and finally service coating as permanufacturer's specification finishedwith aluminium screw and silicon sealent complete in all respect including all incidental charges etc. as per direction of Engineer-in-charge |
| 10 | Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS:732-1983 and IS:1285-1975; Annodized (with required film thickness and specified colour / natural) matt finished conformingtoIS:1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer-In Charge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film, I) Natural white, a) 2- track sliding window, ii) Top |
| 11 | I) Natural white, a) 2- track sliding window, i) Bottom |
| 12 | I) Natural white, a) 2- track sliding window, ii) side frame. |
| 13 | a) 2- track sliding window, d) Shutter for all track sliding window. i) Style side member. |
| 14 | d) Shutter for all track sliding window. i)Top member. |
| 15 | d) Shutter for all track sliding window. iii) Interlock member |
| 16 | d) Shutter for all track sliding window. i) Bottom member. |
| 17 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. v) 6mm thick clear glass. |
| 18 | Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units: (A) Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding roller sand other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing inbetweenwindowframeandmasonrywork (walls, column, beam. lintels etc.) as well as between glass and shutter frame for fixing glass and Poly slphide sealant and in between shutter and window frame where necessary including cutting to requisite sizeand fixing glassas per drawing, specification and direction of EIC. Therate includes the hire charge of all tool sand plants, including all incidental charges, adhesive, join eriessuchasscrew, cleat angle etc. but excluding the cost of extruded aluminiumsections, glass, neoprene / EPDM gasket, locking arrangement and rollers. i ) 2 track sliding window. |
| 19 | Supplying PVC rollers for sliding windows as per direction of Engineer in charge. |
| 20 | Supplying maruti lock (100mm) |
| 21 | Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge. i) For sliding windows, b) 'U' shaped EPDM gasket for frames. |
| 22 | Supplying, fitting & fixing Zn-Alalloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55mm & 25mm self tapping screw, EPDM Washer 16mm dia & 3mm th. washer etc. complete with 150mm end lap and onecorrugation minimum side lap. (Payment to be made on area of finished work). (i) In Roof:- a) With 0.5 mm thick sheet |
| 23 | Supplying, fitting&fixingUPVCpipesA-Typeandfittingsconformingto IS:13592-1992withall necessaryclampsnails, includingmakingholes in walls, floor etc. cutting trenches in any soil throughmasonry concrete structuresetcifnecessaryandmendinggooddamagesincludingjoiningwith jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: (ii) 110 mm. Dia. |
| 24 | Supplying, fitting & fixing UPVC pipes A-Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damage sincluding joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. B) UPVC Fittings:a) Plain Tee (ii) 110 mm. Dia. |
| 25 | Supplying, fitting & fixing UPVC pipesA-Typeand fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil throughmasonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. B) UPVC Fittings:d) Shoe (ii) 110 mm. Dia. |
| 26 | Anodised aluminium butthinge sofn approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fittedand fixedwith cadmium plated screws: (viii) 125 x 63 x 4.0mm. |
| 27 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded sectionc onforming to I.S. 204/74 fittedand fixed with cadmium plated screws: (iv) 150mm long x 10mm dia. bolt. |
| 28 | Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (c) 300mm long. |
| 29 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (Hexagonal/ Round rod), (ii) 100 mm grip x 10 mm dia rod. |
| 30 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With other than hi-gloss of approved quality, (ii) Two coats (white in shade). |
| 31 | Priming one coat onsteel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 32 | Add, G S T. @ 18.00% over the Item no. - 1 to 31 |
| 33 | Add, C E S S @ 1.00% over the Item no. - 1 to 32 Please Enable Macros to View BoQ information |