| 1 | Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing spreading or stacking the spoils within a lead of 75m. As directed. The item includes necessary trimming the sides of trenches levelling dressing and ramming the bottom bailing out water as required complete. |
| 2 | Earthwork in filling in foundation trenches or plinth with good earth in layers not exceeding 150mm including watering and ramming etc. layer by layer complete (payment to be made on the basis of measurement of finished quantity of work). |
| 3 | Labour for laying 150mm to 200mm boulder soling including rough dressing hand picking and ramming down small pieces in the interstics without rolling but including ramming and preparing the bed to proper level and filling up all joints with sandy clay or earth. |
| 4 | Coat of boulder 150mm North Bengal variety |
| 5 | Cement concrete with 30mm down graded shingles excluding shuttering N.B. variety In ground floor |
| 6 | Hire and labour charge for shuttering with centering and necessary staging upto 4m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns lintels curved or straight including fitting fixing and striking out after completion of works.( upto roof of ground floor) a) 25mm to 30mm thick wooden shuttering as per decision & direction of the Engineer-In- charge |
| 7 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups binders etc initial straightening and removal of loose rust (if necessary) cutting to requisite length hooking and bending yto correct shape placing in proper position and binding with 16 gauge black annealed wire at intersection complete as per drawing and direction. For works in foundation basement and upto roof of ground floor /upto 4m |
| 8 | Ordinary cement concrete (mix 1:2:4) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement if any in ground floor as per relevant IS codes. River Bazree |
| 9 | Rubble masonry in cement (1:6) with hard dressed stones from approved quarries and clean coarse and washed sand including carriage of all materials to site . In fine dressed work in building In ground floor |
| 10 | 125 mm thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. Main hall long |
| 11 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame excluding cost of concrete, iron Butt Hinges and M.S clamps (The quantum should be corrected upto three decimals). Sal: Siliguri |
| 12 | Supplying fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc by cement concrete (1:2:4) as per direction (cost of concrete will eb paid seperately) |
| 13 | Plaster(to wall , floor, ceiling etc) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating nosing and drip course, scaffolding/staging where necessary (ground floor) Excluding cost of chipping over concrete surface. |
| 14 | Plaster (to wall, floor, ceiling etc) wih sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating nosing and drip course, scaffolding staging where necessary (ground floor (Excluding cost of chipping over concrete surface) with 1:4 cement mortar |
| 15 | Neat cement punning about 1.5mm thick in wall dado, window, sills floor drain etc. Plinth long cross Floor |
| 16 | Panel shutters of door and window as oper design (ecah panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In Ground floor In case of non supply of single plank, panel rate of reduction of 20% will be made) ii) Sishu, gamar, champ, badam, bhola, mogra, hallak |
| 17 | Glazed Shutters of doors, window fan light, clerestory windows etc, as per design (with ordinary glass of 7.4kg/sq.m. 3mm thick) fitted with putty bed and teak wood bead and nails including fitting and fixing shutter in position but excluding the cost of hinges and other fittings cost of glass, putty, wooden beads etc which will be paid separately. In Ground floor 40mm thick shutters Sishu, gamar, champ, badam, bhola, mogra, hallak |
| 18 | Artificial stone in floor dado,staircase etc. with cement concrete (1:2:4) with stone chips laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works, using cement @1.75kg/sq.m all complete including all materials and labour. In ground floor 3mm thick topping (High polishing grinding on this item is not permitted) with ordinary cement. Using grey cement 25mm thick |
| 19 | M.S. structural works in roof trusses with tubular sections conforming to IS:806-1957 & IS:1161-1958 connected to one another with bracket gusset cleats as per design, direction of Engineer-In charge complete including cutting to requisite size. fabrication with necessary metal arc welding conforming to IS:816-1956 & IS: 9595 using electrodes of approved make and brand conforming to IS: 814-1957 haulage hoisting and erection all complete. The rate includes the cost of rolled steel section consumables such as electrodes gas and hire charges of all toolsand plants and labour required for the work including all incidental charges such as electricity charges, labour insurance charges etc. (payment to be made on the basis of calculated weight of structural tubular members as specified in relevant IS code in finished work. Payment for gusset bracket cleat may be made bu adding the actual weight of such items with the weight of finished structural members. The rates are considered for a height of erection 8m/2nd floor leves from the ground.Add 1.5% extra over the rate for each additional floor or 4m. beyond initial 8m.or part thereof. |
| 20 | Galvanized corrugated iron sheet work (excluding the supporting frame work) fitted and fixed with 10mm dia J or L hook-bolts , limpet and bitumen washers and putty complete with 150mm end lap and one corrugaion minimum side lap.(payment to be made on area of finished work), (GCI sheet to be supplied by contractor |
| 21 | Galvanised iron sheet ridging fitted with necessary bolt, screws, washers etc complete(225mm end laooing) 30mm lapping each way with 0.63mm sheet |
| 22 | Galvanized iron sheet caves gutter fitted and fixed with necessary 50mm X 6mm M.S. flat bar clamps bent o design bolts nuts washers etc. complete. Eaves gutter made of 0.63mm sheets (300mm End lapping) 225mm wide gutter |
| 23 | Supply fitting fixing cast iron dwon pipes conforming to IS:3989-1970 and IS: 1729-1964 in position with necessary clamps, nails including making hole in wall floor etc. and cutting trenches in any soil through masonry concrete structures etc. if necessary and mending good damages including jointing with jointing materials complete. (payment will be made on centre line measurement of the total pipe line includng specials. Payment for specials will however be paid separately. 100mm dia |
| 24 | (A) Wood work in posts , post plates, rafter, battens, truss members, purlins etc. fitted and fixed complete (excluding the cost of bolts only, but including the cost of nails, screws etc) |
| 25 | Ceiling of commercial ply as per design fitted and fixed complete (excluding the supporting frame work but including necessary wood battens of size 40mmX25mm) In ground floor |
| 26 | Wooden eaves board as per design fitted and fixed complete:in ground floor plain eaves board (local self) 25mm thick |
| 27 | Rendering the surface of walls and ceiling with white cement base WATER PROFF wall putty of approved make & brand (1.5mm thick) |
| 28 | (b) Priming one coat on timber or plastered surface with synthetic enamel oil bound primer of approved quality including smoothening surfaces by sand preparing etc. |
| 29 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand parpering etc. including using of approved putty etc. on the surface if necessary On Timber of plastered surface With super gloss (hi gloss) One coat (with any |
| 30 | Applying exterior grade Acrylic primer of approved quality and brand on plaster or concrete surface old or new surface to receive decorative textured (mat finish) or smooth finish acrylic exterior emulsion paint including scrapping and preparing the surface throughly complete as per manufacturer's specification and as paer direction of the EIC. In ground floor |
| 31 | Applying interior grade acrylic primer of approved quality and brand on plastered or concrete surface ols or new surface to received distemper/Acrylic emulsion paint including scraping and preparing the surface thoroughly, complete as per manufactured specification and as per directions of the EIC |
| 32 | Applying decorative cement based paint of approved quality after preparing the surface including scraping the same throughly (plastered or concrete surface) as per manufacturer's specification . In ground floor |
| 33 | Acrylic distemper to interior wall, ceiling with a coat of solvent based interior grdae Acrylic primer (as per manufacturer's specification) including cleaning and smoothing of surface. |
| 34 | Iron but hinges of approved quality fitted and fixed with steel screws, with ISI mark |
| 35 | (v) 75mmX60mm X 3.15mm |
| 36 | (b) Supplying Godrej mortice lock chromium plated with keys 6 levers including fitting & fixing complete. |
| 37 | Anodised aluminium barrel / tower ? Socket bolt (full covered) of approved manufactured from extruded section conforming to IS 204/74 fitted and fixed with cadmium plated screws. |
| 38 | Anodised aliminiumD-type handle of approved quality manufactured from extruded section conforming to I.S. specification (IS 230/72) fitted and fixed complete. |
| 39 | Anodised aluminium Aldrop/sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. |
| 40 | Iron catch hook of approved quality fitted and fixed to shutter and chowkat Please Enable Macros to View BoQ information |