| 1 | Dismantling the existing damaged brick masonry wall under 3m hight including removal of demolish materials and all labour charges and conveyance charges etc.complete.., |
| 2 | Dismantling the existing damaged Reinforced cement concrete including removal of demolish materials and all labour charges and conveyance charges etc.complete.., |
| 3 | Picking the existing cement plaster surface. |
| 4 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum |
| 5 | Supplying and filling in foundation and basement with filling Quarry Dust in layers of not more than 15cm.thick well rammed watered and compacted etc., complete complying with standard specification. |
| 6 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification |
| 7 | Plain Cement concrete 1:2:4 (one cement two sand and four aggregates) Using 20mm gauge hard broken granite jelly for foundation inc. consolidation and dewatering for foundation wherever necessary etc.complete. |
| 8 | Supplying, erecting with necessary supports for plain surface such as RCC Boxing side slab and silmilar RCC slab with all cross bracing etc., complete in all floors of any height ( the retrived materials ) should be taken back by the contractor the payment for cenetering shall be given after the concrete is laid ( For Rectangular or Square Columns ) |
| 9 | Reinforced Cement concrete 1:1.5 :3 (one cement, one and half sand & three course aggregate) using 20mm gauge hand broken/ and broken granite stone for all RCC items of works excluding centering shuttering and cost of reinforcement but including curing etc.,complete and also including fixing fan clamps and fixtures in rcc works wherever necessary as directed by departmental officer etc., complete. For Ground Floor |
| 10 | Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors. |
| 11 | Brick work in CM 1:5 (one cement & five sand) using III class country bricks of size 83/4\\"X41/4\\"X 21/4\\" including finishing, curing, etc., complete complying with standard specification - 100CFT For Ground Floor |
| 12 | Plastering with cm 1:5 (one cement three sand) 20mm thick. in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications |
| 13 | Plastering with cement mortar (1:5) 12mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306) |
| 14 | Supply and fixing of TMT with Doors and Windows with one coat of Red oxide with Primer including all costssuchaswelding,grindingandfabricationcharges,costandconveyanceofallmaterialstositeetc,completeasperstandardspecification. |
| 15 | Construction of inspection chambers of following sizes with earth work excavation for foundation with Dust Filling 10mm thick and Plain cement concrete bed in C.M. 1:5:10 using 40mm HBG jelly 10mm thick for foundation, 23cm thick brick wall work in C.M. 1:5 for chambers, Inner and Outer Plastering with C.M. 1:3 12mm thick, benching, channelling, 75mm thick RCC loose slab covering in C.M. 1:2:4 mix using 20mm blue granite jelly including necessary reinforcement, etc., complete 60mm X 60mm X 60mm |
| 16 | Supply of PVC pipe and G.I pipes and PVC pipe & Specials.40mm PVC Pipe |
| 17 | 40mm PVC Coupling |
| 18 | 40mm PVC Tee |
| 19 | 40mm PVC Elbow |
| 20 | 40 mm GM gate Valve |
| 21 | 25mm PVC Pipe |
| 22 | 25mm PVC Coupling |
| 23 | 25mm PVC Tee |
| 24 | 25mm PVC Elbow |
| 25 | Brass Chromium Plated Screw Down Tap 20mm dia (Heavy Type) |
| 26 | 110mm PVC Pipe |
| 27 | 160mm PVC Pipe |
| 28 | 160mm PVC Elbow |
| 29 | Supply and delivery of 2000 lit capacity and fixing of HDPE tank as per IS 12701/1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,complete as per standard specification.2000 litre HDPE tank |
| 30 | Wiring with 2 x 4 sq.mm. PVC insulated SC unsheathed FRLScopperCu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC ceiling with MS accessories inflush with wall with 150mm x 100mm x 75mm MS switch box concealed typewith3mmthickhylumsheetcoverfor15A3pinflushtypenoninterlockingCSplugwithcontinuousearthwireconnectionof4sq.mmcopperwireandrnakinggoodoftheconcealedportionforconcealed power plug point |
| 31 | Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch and making good of the concealed portion with suitable colour for PVC concealed light / Fan Point (For electronic regulator) (5 Points Per Coil) SD -21 |
| 32 | Supply and fixing of single box type (philips / Havells / Eq) suitable for 4 feet 20W LED tube light with TW round blocks on wall or ceiling with 20W LED tube light with PVC unsheathed Copper leads from terminals to the fitting |
| 33 | Supply and fixing of 1200mm (48\\") sweep AC ceiling fan (Crompton / Havells / Usha / Equivalent) with 2 module 100W regulator complete with 300mm down rod on existing clamp SD 111 |
| 34 | Supply and fixing of 48W LED Street Light Fitting LED OUTDOOR FITTINGS (LIGHT EMITTING DIODE) Higher End Philips / Havells / Equivalent etc., complete |
| 35 | White washing two coats with freshly burnt shell lime white in colour in all floors including cost of lime and other materials brushes scaffolding charges etc.complete complying with standard specification and as directed. - 100sq.m S.I.333 |
| 36 | Painting 2 coats with approved cement paint over cement plastered wall surface, ceiling and other new surface and including cleaning, preparing the surface and curing etc., complete. |
| 37 | Painting with Ready Mixed Enamel Paint over the new Iron works of approved quality and colour with priming coat including the cost all materials etc., complete, in all floors. |
| 38 | Painting with Ready Mixed Enamel Paint over the Old Iron works of approved quality and colour with priming coat including the cost all materials etc., complete, in all floors. |
| 39 | Supplying and fixing in position of best approved colour design and quality FRP sheets of 1.5mm thick with necessary 'U' or 'J' bolts, bitumen washers and cutting the FRP sheets to the required size etc.complete. |
| 40 | Fabriction supply and erection of tubulor post with Truss (100mm,80mm,75mm) The Rate shall be include the cost of tobulor post Truss members, labour charges for manufacturing and erection and Painting etc.,complete. as per departmental specification and drawings |
| 41 | ADD GST 18% Please Enable Macros to View BoQ information |