Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Construction of Panel Room and allied civil works at Lift Station 02 - L&T Colony in Depot 128, Area X |
| 2 | Completion of collection well and Suction well |
| 3 | Plastering with cement mortar 1:3 (SRC) using Crushed stone sand (M-sand) for 20mm thick including curing, etc., complete |
| 4 | Plastering with cement mortar 1:3 (SRC) using Crushed stone sand (M-sand)) for 12mm thick including curing, etc., complete. |
| 5 | Supply and erection of Cast Iron single faced manually operated rising type 750mm dia penstock with extension rod of 5.5m length conforming to relevant IS with IS markings on it, having cast iron door and frame with Gunmetal seating, spindle made of Stainless steel, CI head stock with gear arrangment and hand wheel fitted in well. |
| 6 | Supply and erection of Cast Iron single faced manually operated rising type 500mm dia penstock with extension rod of 6m length conforming to relevant IS with IS markings on it, having cast iron door and frame with Gunmetal seating, spindle made of Stainless steel, CI head stock with gear arrangment and hand wheel fitted in well. |
| 7 | Supplying and fixing C.I.steps. |
| 8 | Colour washing two coats over one coat of white washing |
| 9 | Supply and installation of SS open mesh flooring with 25x6mm thick flats for outer frame and 25x3mm SS and 12x3mm SS flats spaced at 30mm and 60mm respectively and 50x10mm SS flats for mesh support and 50x50x6mm SS angle for opening forming a mesh over the surface of the well etc,complete |
| 10 | Grouting of well to arrest seepage of subsoil water into suction well as per the directions of Engineer incharge |
| 11 | CONSTRUCTION OF PANEL CUM OFFICE BLOCK - 12mx7m |
| 12 | Earth work excavation in hard stiff clay, stiff black cotton, hard red earth, shales, muram, gravel stoney earth and earth mixed with small size boulders as per SS 20B with initial lead of 10m and lift of 2.0m |
| 13 | Supplying and filling sand for foundations and basement including watering consolidating ramming, etc., complete. |
| 14 | Cement Concrete 1:3:6 using 40mm gauge hard broken stone jelly for plain cement concrete works including laying in layers of not more than 15 cm thick, including ramming, curing etc. complete. |
| 15 | Providing form work with centering for soffits of reinforced cement concrete slabs or plain surfaces including strutting upto 3m high.i) upto 3m high. |
| 16 | ii) Above 3m to 4m |
| 17 | iii) Above 4m to 5m |
| 18 | Cement concrete 1:1 ½:3 using 20mm gauge hard broken stone jelly for reinforced cement concrete works excluding cost of steel, centering, shuttering and cost of steel reinforcement but including laying in position, compacting, curing, finishing, etc., |
| 19 | i)Upto 1.5m |
| 20 | ii) 1.5m to 4.5m |
| 21 | iii) 4.5m to 9m |
| 22 | Laying C.C. 1:2:4 for RCC sunshade work using 20mm BG jelly 100mm thick at wall end and 80mm thick at free end projecting 900mm from the wall face moulded along with RC lintels and tiled into the full thickness of wall where there are no lintels excluding cost of steel reinforcement but including shuttering, compacting, curing and finishing etc. complete. |
| 23 | Supplying, fabricating and laying in position MS rounds or RTS rods for RCC works including cost of reinforcement, binding wire, cutting bending, cranking and tying in position with binding wire assembly, etc. |
| 24 | Stock brick work in cement mortor 1:4 using second class bricks including curring etc. complete for 23 cm thick wall. |
| 25 | upto 1.5m from G.L. |
| 26 | Ground floor |
| 27 | Stock brick work in cement mortor 1:4 using second class bricks including curring etc. complete for over 23 cm thick wall. |
| 28 | Stock brick work in cement mortor 1:4 using second class bricks including curring etc. complete for 11cm thick wall. |
| 29 | 1st floor |
| 30 | Plastering with C.M 1:4 for 12mm thick including curing etc. complete. |
| 31 | Special ceiling plastering for RCC slabs, and beams in CM 1:3 – 10mm thick including hacking and curing, etc., complete. |
| 32 | Flooring with 100mm thick base cement concrete 1:4:10 using 40mm gauge, hard broken stone jelly including laying ramming, curing, etc., complete. |
| 33 | Paving hydraulic pressed cement mosaic tiles of approved colour and of size 20 x 20 x 20 cm, finished thickness with small verona of Indian marble chips (other than salem magnasite) with cement mortar 1:3 20mm thick and pointed with the same coloured cement including polishing with power polisher, to a high degree of scholar so as to be perfectly smooth and glossy with grey colour mosaic tiles. |
| 34 | Terrace flooring with two course of flat tiles of 15cmx15cmx12mm using CM 1:3 mixed with crude oil 10% by weight of cement and pointed with same oiled mortar |
| 35 | Weathering course concrete with broken brick jelly 20mm guage in pure slacked lime over RCC roof slab in proportion of 32:12 (no sand to be sued) well beaten with wooden beaters to be required depth of 80mm thick and giving rerquired slope and thickness to roof as required etc. complete. |
| 36 | Best Indian T.W. cupboard with frames 100 x 60mm alround and shutters 40mm thick with moulded panels in 20mm thick planks and 4 Nos.of iron hold fasts fixed in C.C.1:2:4using 3 to 10mm chips 6 Nos.of butt hinges 100mm long including necessary fittings. |
| 37 | Maufacturing supplying and fixing in position aluminium anodised Natural colour mat finish with openable type window with extruded Alu. Sections with two panels of size (Frame- 38 x 33 x21 x 2.4mm @ 0.615 Kg/m, Shutter: Bottom, Top- 38.5 x 33 x 24.5 x 3 & 4mm 0.706 Kg/m, Interlocking vertical- 59 x 33 x 25 x 2.5mm @ 1.135 Kg/m) with necessary accessaries such as rubber beadings best quality of lock handle hinges,stays and fixing 4 mm thick plain / frosted/ pin headed glass including cost of all materials labour for electricalconsumption required for drilling holes in RCC columns,beams, masonry wherever necessary with power drill to the extent required and made good to the original conditions after fixing as directed by the Board officers.The Al.Surfaces is to be anodised with matt finish usder electrically condition in accordance with ISI1868/1962 specification for an average anodic film thick of not less than 15 microns. (All materials should be got approved by the Site Engineer before fixing in position) |
| 38 | Supplying, fabricating and fixing in position of Alumi.Anod.natural colour matt finish door half glazed and half PLB board using 12 mm thick PLB board and 5.5 mm thick glazed door using rectangular Alu.Box section of following sizes for frame and shutte |
| 39 | Supplying and fixing in position of aluminium anodised colour matt finish Louvered Ventilator. The outer frame will be 62x38x2mm @ 1.17 Kg / m and the louvers with moving arrangements will be made with Alu. Channel of size 60x30x4 mm @ 1.27 kg /m. |
| 40 | Supplying & fixing M.S. grills for window and gate including one coat of primer with red lead etc. complete as directed. |
| 41 | Colour washing two coats |
| 42 | White washing two coats |
| 43 | Supplying and fixing 100mm dia A.C. down fall pipe including cost of 100mm dia A.C. pipe, shoe, bend brackets and teak wood plugs gratings etc. complete with door arrangements. |
| 44 | Precast slab in Cement Concrete 1:2:4 using 12-20mm BG jelly for reinforced cement concrete works including cost of steel, centering, shuttering and cost of steel reinforcement and including laying in position, compacting, curing, finishing, etc., comple |
| 45 | Refilling with excavated soils (other than sand) complying with standard specifications for filling in foundations and basement. |
| 46 | Preparation of structural drawing for the construction of pump room as per Soil test report as per the directions of Engineer |
| 47 | WATER SUPPLY AND SANITARY ARRANGEMENTS |
| 48 | Earth work excavation in hard stiff clay, stiff black cotton, hard red earth, shales, muram, gravel stoney earth and earth mixed with small size boulders as per SS 20B with initial lead of 10m and lift of 2.0m |
| 49 | Supplying and filling Msand for foundations and basement including watering consolidating ramming, etc., complete |
| 50 | Cement concrete 1:3:6 using 40mm gauge hard broken stone jelly for plain cement concrete works including laying in layers of not more than 15cm thick including ramming curing, etc., complete |
| 51 | Stock brick work in cement mortor 1:4 using second class bricks including curring etc. complete for over 23 cm thick wall |
| 52 | Stock brick work in cement mortor 1:4 using second class bricks including curring etc. complete for 23 cm thick wall |
| 53 | Cement concrete 1:1 ½:3 using 20mm gauge hard broken stone jelly for reinforced cement concrete works excluding cost of steel, centering, shuttering and cost of steel reinforcement but including laying in position, compacting, curing, finishing, etc., com |
| 54 | Plastering with C.M.1:5 for 12mm thick including curing etc complete. |
| 55 | Refilling with excavated soils (other than sand) complying with standard specifications for filling in foundations and basement |
| 56 | Providing form work with centering for soffits of reinforced cement concrete slabs or plain surfaces including strutting upto 3m high. |
| 57 | Supplying, fabricating and laying in position MS rounds or RTS rods for RCC works including cost of reinforcement, binding wire, cutting bending, cranking and tying in position with binding wire assembly, etc. |
| 58 | Supplying & fixing door shutters for Medium Density Fiber Board of exterior grade 35 mm thick,single leaf conforming to IS:12406/1989 with 35x12 mm T.W.Lipping on all edges with necessary adhesives and CP screws complying with standard specifications. |
| 59 | a) Door |
| 60 | R.C.C. jolly work 50mm thick in cement concrete 1:2:4 including moulding curing, etc., complete. for ventilators. |
| 61 | Paving Hydraulic pressed cement mosaic tiles of approved colour and of size 20cmx20cmx20mm finished thickness with small verona of Indian marble chips (other than Salem magnesite) with cement mortar 1:3-20mm thick and pointed with the same coloured cement |
| 62 | Dadooing walls with glazed tiles of sizes 15cmx15cmx6mm thick laid in CM 1;2, 10mm thick and pointing with white cement using 0.4 Kg/m2 including finishing the joint and pointing flush with tile surface, etc., complete. |
| 63 | Supercem colour washing - Painting two coats with approved cement paint over cement plastered wall surface, ceiling and other new surfaces including cleaning preparing the surface and curing, etc., complete |
| 64 | Supplying and fixing 51cm colour glazed water closet pan with `P’ or `S’ trap including foot rests (colour glazed) and supplying, laying 100mm dia S.W.P, concrete encasing the W.C. appurtenance, etc., complete. |
| 65 | Construction of inspection chambers of following sizes with earth work excavation for foundation with 23cm thick brick jelly cement concrete bed in C.M. 1:4:10 using 40mm Brick jelly for foundation, brick work in C.M. 1:6 for chambers, plastering with C.M 1:5 |
| 66 | Providing and fixing L.S. cover and frame of size 45 x 45cm including necessary masonry work and plastering, etc., complete for OHT. |
| 67 | Supplying & fixing of Wash Hand Basin of size 550mmx400mm with all accessories suchasCast Iron Brackets, 32mm diaCP Waste Coupling, Rubber Plug and Chain, 32mmdia ‘B’ClassGI Waste Pipe, 15mm dia GM Wheel Valve, 15mm dia Nylon Connection, 15mmdiaBrassNipples, 15mmCPPillar Tapetc (Colour without pedastal) |
| 68 | Supplying and fixing best mirror of size 60cmx45cm of 6mm thick with plywood back including necessary fittings, etc., complete. |
| 69 | Supplying and fixing C.P.Towel rails 45cm x 20mm. |
| 70 | Supplying and fixing 25mm GI pipe |
| 71 | Supplying and fixing 25 mm GM Gate Valve |
| 72 | Supplying and fixing 20mm C.P Screw down Tap |
| 73 | Boring and tapping mains and fixing brass screw plugs or ferrules of size 15mm |
| 74 | Providing HDPE tank of capacity 1000litres |
| 75 | Drilling of borewells of size 6\\" to 8\\" dia in Sedimentary formation using hand boresets including insertion of casing pipes supplying and packing of pebbles and conveyance of hand Boreset including loading and unloading. |
| 76 | Supplying and lowering 125mm nominal dia PVC (140mm OD) casing pipe as per IS 12818/1992 for required depth including the cost of cutting, threading and coupling, transporting charges, labour for erection, etc. complete. |
| 77 | Flushing (developing) the bore well for 150 PSI 500 to 600 CFM with air compressor including cost of hire charges for compressor,labour,fuel,consumables,transportation and other items if any required during the operation etc. complete as directed by the Board's Engineer. |
| 78 | Supply delivery and erection & Labour charges for the erection and of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trial run for 10 days. |
| 79 | Construction of Compound Wall and allied works |
| 80 | Hiring of JCB fitting Breaker for Dismantling old concrete structure and buildings and for levelling of site |
| 81 | Earthwork excavation and depositing on bank with initial lead of 10 metres and initial lift 2.00m (in all type of strata) in hard stiff clay stiff black cotton, hard red earth, shales, Muram, gravel, stoney earth and earth mixed with small size boulders S |
| 82 | Upto 2.0 m below GL |
| 83 | Supplying and filling M-sand for foundation and basement including watering, consolidating, ramming etc. complete. |
| 84 | Cement concrete 1:3:6 using Crushed stone sand (M-sand) and 40mm gauge hard broken stone jelly for plain cement concrete works including laying in layers of not more than 15cm thick including ramming curing, etc., complete |
| 85 | Upto 1.5 m below GL |
| 86 | From 1.5 m to 4.5 m below GL |
| 87 | Providing form work with centering for soffits of reinforced cement concrete slabs or plain surfaces including strutting upto 3m high |
| 88 | Upto 3 m above and below GL |
| 89 | Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade for reinforced cement concrete structural elements under controlled water cement ratio with plasticiser using Crushed stone sand |
| 90 | Upto 1.5 m below GL |
| 91 | Upto 1.5 m above GL |
| 92 | From 1.5 m to 4.5 m above GL |
| 93 | Supplying and fabricating CRS/Thermo Mechanically Treated High Corrosion Resistance bars manufactured by Primary steel producers/Integrated Steel Plants as per IS:1786-2008,including fixing with binding wires, assembling and laying in position for all RCC |
| 94 | Stock brick work with II class bricks in cement mortor 1:4 (Crushed stone sand (M-sand)) for 23 cm thick walls including curing etc. complete. |
| 95 | Upto 1.5 m above GL |
| 96 | From 1.5 m to 4.5 m above GL |
| 97 | Band course work flat 10mm to 12mm thick and 50mm deep with C.M. 1:3 (Crushed stone sand (M-sand) including curing, etc., complete as directed |
| 98 | Plastering with cement mortar 1:3 (Crushed stone sand (M-sand)) for 20mm thick including curing, etc., complete 20mm thick sand faced cement plaster on wall upto hight 10 meters above ground level consisting of 12mm thick backing coat of CM 1:3 ( 1 cemen |
| 99 | Colour washing two coats over one coat of white washing |
| 100 | Supplying and fixing barbed wire fencing over theproposed compound wall with ‘L’ angle iron 50 x 50 x 6mm & 1.45m posts bent to shape at 2.5m centres with 6 rows of barbed wire and also in a zig zag manner at 25cm c.c. connecting all the rows with barbed |
| 101 | Refilling with excavated soils (other than sand) complying with standard specifications for filling in foundations and basement |
| 102 | Disposal of surplus earth |
| 103 | Supplying and fabricating and erection of iron gate with of required size as per direction at site with G.I pipes of 50 mm and specials at all sides and 40x40x6mm angles as bracing on which 2 No.of m.s sheet of 16 gauge of size 2x2m each is welded as two |
| 104 | Painting with two coats of ready mixed plastic emulsion paint first class quality and of approved colour over a priming coat including thorough scrapping clean removal of dirt, etc., complete and including necessaary plaster of paris, putty, etc., whereve |
| 105 | Providing and fixing gardening items on site as directed. |
| 106 | Providing and fixing planting plants and shrubs on compound wall as directed |
| 107 | Supplying and filling Crushed stone sand (M-sand) for foundations and basement including watering consolidating ramming, etc., complete for flooring purpose inside pumphouse |
| 108 | Supply and conveying of Rubber Moulded Hydraulic Pressed Paver Block |
| 109 | laying of paver block for smooth road purpose(labour only) |
| 110 | Construction of DG Platform and allied works |
| 111 | Excavation in hard stiff clay, stiff black cotton, hard red earth, shales muram, gravel stoney earth and earth mixed with small size boulders and hard gravelly soil as per SS 20B with initial lead of 10 mts and lift of 2.00 mts. |
| 112 | Supplying and filling sand for foundation and basement including watering consolidating ramming etc. complete |
| 113 | Cement Concrete 1:3:6 using broken jelly 40mm gauge hard broken stone jelly for plain cement concrete works including laying in layers of not more than 15cm thick including ramming curing etc.complete |
| 114 | Stock brick work with second class bricks in C.M 1:4 for 23cm thick wall including curing etc. complete. |
| 115 | a) 1.5m above GL and 1.5m below GL |
| 116 | Plastering with cement mortar 1:4 for 12mm thick including curing etc. complete |
| 117 | Providing MS Shed - Supply and delivery of M.S sheet as per drawing, made up of MS angles and roof covered with MS sheet 2mm thick including cutting, welding, grinding, painting with one coat priming coat and two coats of ready mixed paint of superior quality of grey or any other colour, locking arrangements and labour charges etc. complete. |
| 118 | Construction of ISMB Column and allied works |
| 119 | Excavation in hard stiff clay, stiff black cotton, hard red earth, shales, muram, gravel stoney earth and earth mixed with small size boulders as per SS 20B with initial lead of 10m and lift of 2.0m etc. complete. |
| 120 | Upto 2.0 m below GL |
| 121 | From 2.0 m to 3.0 m below GL |
| 122 | Supplying and filling crushed stone sand (M sand) for foundation and basement including watering, consolidating, ramming etc. complete. |
| 123 | Cement concrete 1:3:6 using 40mm gauge hard broken stone jelly including laying in layers of not more than 15cm thick including ramming curing etc complete (M-sand) |
| 124 | 1.5 m to 4.5 m below GL |
| 125 | Providing form work with centering for soffits of reinforced cement concrete slabs or plain surfaces including strutting upto 3m high. |
| 126 | Upto 3.0 m height above and below GL |
| 127 | Providing and laying in position machine batched machine mixed and machine vibrated design mix. Sulphate resistance cement concrete M25 grade (M-sand) for reinforced cement concrete structural elements under controlled water cement ratio with plasticiser using 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, Mixer, vibrator, etc. as per standard specification and as directed at site |
| 128 | Upto 1.5 m below GL |
| 129 | From 1.5 m to 4.5 m below GL |
| 130 | Upto 1.5 m above GL |
| 131 | From 1.5 m to 4.5 m above GL |
| 132 | Supplying, fabricating CRS bars manufactured by Primary steel including cost of steel, binding wire, cutting, cranking and tying, in position with binding wire assembly etc complete. |
| 133 | Plastering with cement mortar 1:3 (SRC) using Crushed stone sand (M-sand) for 12mm thick including curing, etc., complete. |
| 134 | Colour washing two coats over one coat of white washing |
| 135 | Refilling with excavated soils (other than sand) complying with standard specifications for filling in foundations & basement |
| 136 | Disposal of surplus earth |
| 137 | Supply and fixing ISMB 400mm of 66.3kg/m for 8.5m on column over suction well |
| 138 | Erecting pulley block of 3 Tonne capacity with a 3m chain including additional chain length of 10m facilitate for horizontal movement on the beam etc complete - For Suction well |
| 139 | Painting with superior quality ready mixed paint of chocolate, light green, grey or any other approved colour over ISMB (for new iron work two coats). |
| 140 | Construction of Valve Chamber |
| 141 | Earth work excavation in all kinds of soils except hard rock requiring blasting inclusing of shoring strutting and bailing out water whereever necessary refilling the sides of foundation with excavated earth in layers of 15cm thick well rammed and consolidated depositing surplus earth within in compound in places as shown by the departmental officers clearing and levelling the site with initial lead of 10mts. and lift of 2m etc. complete. |
| 142 | Upto 2 m below GL |
| 143 | From 2 m to 3 m below GL |
| 144 | Supplying and filling Crushed stone sand (M-sand) for foundations and basement including watering consolidating ramming, etc., complete |
| 145 | Cement concrete 1:3:6 using Crushed stone sand (M-sand) and 40mm gauge hard broken stone jelly for plain cement concrete works including laying in layers of not more than 15cm thick including ramming curing, etc., complete |
| 146 | From 1.5 m to 4.5 m below GL |
| 147 | Providing formwork with centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3.0m high etc complete complying with standard specifications. |
| 148 | Upto 3 m below GL |
| 149 | Providing and laying in position machine batched machine mixed and machine vibrated design mix. Sulphate resistance cement concrete M25 grade (M-sand) for reinforced cement concrete structural elements under controlled water cement ratio with plasticiser using 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, Mixer, vibrator, etc. as per standard specification and as directed at site |
| 150 | Upto 1.5 m below GL |
| 151 | From 1.5 m to 4.5 m below GL |
| 152 | Supplying and fabricating CRS/Thermo Mechanically Treated High Corrosion Resistance bars manufactured by Primary steel producers/Integrated Steel Plants as per IS:1786-2008,including fixing with binding wires, assembling and laying in position for all RCC works |
| 153 | Cement concrete 1:2:4 (SRC) using Crushed stone sand (M-sand) and 20mm gauge hard broken stone jelly for plain concrete works including laying ramming curing, etc complete for benching and channeling as directed. |
| 154 | Upto 1.5 m below GL |
| 155 | From 1.5 m to 4.5 m below GL |
| 156 | Precast slab 100mm thk in Cement Concrete 1:2:4 using Crushed stone sand (M-sand) and 12 to 20mm gauge hard broken stone jelly for reinforced cement concrete works including cost of steel, centering, shuttering and cost of steel reinforcement and including laying in position, compacting, curing, finishing,as per drawings,or as directed etc., complete. |
| 157 | Plastering with cement mortar 1:3 using Crushed stone sand (M-sand) & SRC for 20mm thick including curing, etc., complete |
| 158 | Plastering with cement mortar 1:3 using Crushed stone sand (M-sand) & SRC for 12mm thick including curing, etc., complete |
| 159 | Refilling with excavated soil (other than sand) compling with standard specification for filling in foundation and basement etc. complete |
| 160 | Disposal of surplus earth |
| 161 | Supplying and fixing C.I.steps. |
| 162 | PIPES AND SPECIALS FOR SUCTION WELL |
| 163 | Supplying, conveying and fixing the following CI specials as per IS 1538 & CI pipes as per IS 1536 etc. complete. |
| 164 | Delivery Pipe & related Specials within Well |
| 165 | 100 mm dia CI D/F Duckfoot Bend |
| 166 | 200 x 100 mm CI D/F taper |
| 167 | 300 x 200 mm CI D/F taper |
| 168 | 300 mm dia CI - 3m D/F pipe |
| 169 | 300 mm dia CI - 2.5m D/F pipe |
| 170 | 300 mm dia CI - 2m D/F pipe |
| 171 | 300 mm dia CI - 1.5m D/F pipe |
| 172 | 300 mm dia CI D/F 90 deg Bend |
| 173 | 300 mm dia CI - 1.5m D/F pipe |
| 174 | Delivery Pipe & related Specials within Valve Chamber |
| 175 | 300 mm dia CI - 0.5m D/F pipe |
| 176 | 300 mm dia CI Non-Return Valve |
| 177 | 300 mm dia CI - 0.5m D/F pipe |
| 178 | 300 mm dia CI Sluice Valve |
| 179 | 300 mm dia CI - 0.5m D/F pipe |
| 180 | Common Header Pipe & related Specials within Valve Chamber |
| 181 | 500 x 300mm CI A/F Radial Tee |
| 182 | 500 mm dia CI - 0.5m D/F pipe |
| 183 | 500 x 350 mm CI D/F taper |
| 184 | 350 mm dia CI Sluice Valve |
| 185 | 500 x 350 mm CI D/F taper |
| 186 | 500 mm dia CI Fl/Spi Tail Piece |
| 187 | 500 mm dia Blank Flange |
| 188 | Jointing the C.I.Double flanged pipes and specials with rubber insertion to the required specifications with M.S. bolts and nuts, complete and testing the pipies to the required pressure with water (including cost of jointing materials)For depth upto 2m, |
| 189 | 100 mm |
| 190 | 200 mm |
| 191 | 300 mm |
| 192 | 500 mm |
| 193 | 350 mm |
| 194 | 500mm dia CI Pumping main B class |
| 195 | 500 D/S bend |
| 196 | SUPPLY, DELIVERY, ERECTION & COMMISSIONING OF ELECTRICALLY DRIVEN NON CLOG SUBMERSIBLE SEWAGE PUMPSETS WITH ALLIED ELECTRICAL WORKS FOR SEWAGE PUMPING STATION AT SPS-01 (L&T Colony) |
| 197 | Supply, delivery, erection, testing and commissioning of non-clog submersible sewage pumpset with following duty point, including required capacity 3 Ph, 415 V, AC, 50 Hz, Electrical Motor with suitable weather proof cable (Copper ) of total length of 35 m, VFD control panel, Pedestal Coupling, guide wire / guide pipe (GI-50 mm dia) of length 10m, M.S.(GLVD) lifting chain of length 10m, necessary level controlling probes with sufficient length of armoured copper LTUG cable to connect the probe from the junction box to the control panel, fasteners including laying of pump cable under ground with suitable conduit and clamping on walls / trays and incidental civil works etc.complete. |
| 198 | Pump 1 - 15554.62 lpm against a total head of 22 m |
| 199 | Pump 2 - 3472.22 lpm against a total head of 22m |
| 200 | Variable Frequency drive |
| 201 | 100HP |
| 202 | Supply, delivery, erection, testing and commissioning of electrically driven non-clog sewage submersible Grit pumpset including agitator arrangements, with the following duty point, including required capacity 3 Ph, 415 V, AC, 50Hz Electrical Motor with suitable weather-proof cable (copper ) of total length 25 m, control panel, Skirtbase, Flanged Elbow, lifting chain M.S.(GLVD) of length 10m, necessary level controlling probes with sufficient length of armoured copper LTUG cable to connect the probe from the junction box to the control panel, fasteners including laying of pump cable under ground with suitable conduit and clamping on walls / trays and incidental civil works etc.complete. |
| 203 | Grit Pump - 1900 lpm against a total head of 9 m |
| 204 | Supply, delivery, erection, testing and commissioning of following sizes of power shunt capacitor for power factor improvement, suitable to operate on 415V, 3Ph,50Hz A/C supply, on suitable angle iron frame-works (37.5 mm x 37.5 mm x 6.24mm ) at a height of 0.25m from the ground, including earthing and incidental civil works etc., complete. |
| 205 | 60 KVAR (8 stage) |
| 206 | Supplying and fixing of 400 Amps Triple Pole fuse carrier in MS Sheet steel encloure with provision for accommodating the TNEB meter including earthing etc., complete. |
| 207 | Supplying and fixing of 400 Amps main switch with enclosure |
| 208 | Supply, delivery, erection, testing and commiossioning of floor mounted M.V.panel with aluminium bus bars and consisting of required quantities of the following accessories with necessary interconnections between busbars, switches and trunking box, measuring instruments such as voltmeters,ammeters with selectorswitches, energy meter,phase indicating lamps, etc., complete with incidental civil works & constructing concrete plinth for MV Panel above MFL and comprising of following and as per specifications & drawings; |
| 209 | Capacity of M.V. Panel - 400 Amps |
| 210 | 400 A FP(SN) MCCB 50 kA (for EB) |
| 211 | 300 A FP(SN) MCCB 35 kA (for DG) |
| 212 | 300 A TP MCCB 35 kA for Outgoing 1 no. |
| 213 | 200 A TP MCCB 35 kA for Outgoing 4 nos. |
| 214 | 100 A TP MCCB 35 kA for outgoing 3 nos. |
| 215 | Supply, delivery, erection, testing and commissioning of following capacity Diesel Generator set, Phase, 50Hz, 415V, consisting of Diesel Engine capable of delivering continous brake horse power with standard fittings, water-cooled Radiator, acuostic enclosure to restrict the noise level as per TNPCB norms, Residential silencer with exhaust pipe arrangements, suitable alternator (brushless), self-excited, self-regulated, suitable for continous operation. AMF Panel consisting of ammeter with CT's and selector switch, voltmeter with selector switch MCCB, energy meter, earth fault relay, indicating lamps, fuses, and required 1.1KV grade PVC armoured aluminium cable from alternator to alternator control panel , 12/24V battery, battery leads, battery charger etc.Coupling with guard ,Fuel tank ( 8 hours capacity ) common rigid MS channel Base frame, antivibration mounting pad setc.complete. |
| 216 | Capacity of D.G. Set - 160 kVA |
| 217 | Supplying and clamping of variuos sizes of PVC insulated PVC sheathed armoured aluminium LT UG cable by MS clamps on wall or in a trench to be excavated at a depth of 2 ½ ' putting 6” layer of sand and covering the cable with brick and sand refilling the earth to make good as directed. |
| 218 | From EB to the MV Panel (Underground) |
| 219 | size 3.5C,240 Sqmm |
| 220 | 300A MCCB of MV Panel to Control Panel of DG (Under ground) |
| 221 | size 3.5C, 185 Sqmm |
| 222 | From 200 A MCCB of MV Panel to Control Panel of Pump 1 (Wall) |
| 223 | size 3.5C, 185 Sqmm |
| 224 | From 200 A MCCB of MV Panel to Control Panel of Pump 2,3 (Wall) |
| 225 | size 3.5C, 95 Sqmm |
| 226 | From 100 A MCCB of MV Panel to Control Panel of Grit Pump |
| 227 | size 4C, 16 Sqmm |
| 228 | From 100 A MCCB of MV Panel to Capacitor panel |
| 229 | size 3.5C,120 Sqmm |
| 230 | From 100A MCB of MV Panel to LDB and PLC Panel (Wall)size 4 core 16 sq.mm |
| 231 | From control Panel of Pump to Local P.B. Station and for PLC signal cablessize 3 core 2.5 sq.mm copper cable (Under ground) |
| 232 | Supplying and fixing of cable gland and termination with Al. cable lugsfor the following sizes of PVC insulated PVC sheathed armoured alumunium LT UG cable and with earth connection. |
| 233 | size 3.5C,240 Sqmm (EB) |
| 234 | size 3.5C, 185 Sqmm (DG) |
| 235 | Size 3.5C, 185 sq.mm (Pump 1) |
| 236 | Size 3.5C, 95 sq.mm (Pump 2,3) |
| 237 | Size 4C,16 sq.mm (Grit Pump) |
| 238 | size 3.5C,120 Sqmm (capacitor) |
| 239 | Size 4 core 25 sq.mm (LDB & PLC) |
| 240 | size 4 core 2.5 sq.mm copper |
| 241 | Supply delivery and fixing of out door weather proof junction box fabricated in MS sheet steel (12 SWG for front 14 SWG for other sides) near the suction well for terminating the Pump power cable and control cable on an angle iron frame at convenient height for working and above the local MFL with provision for terminal block & earthing as per IS including incidental civil works etc.,complete. |
| 242 | For Pump 1 |
| 243 | For Grit Pump |
| 244 | Supply, delivery and fixing of out door wheather proof Local Push Button station in the compartment provided in the Junction Box with 1 No\\"ON\\" and 1 No \\"OFF\\" push buttons (the \\"OFF\\" push button shall be locable in \\"OFF\\" position). |
| 245 | Supply, delivery and erection of Three Phase 8 way 63A Amps, 10kA LDB with the following:1 No of 63 A FP isolator for incoming supply3 Nos. of 16A, DP RCCB10 Nos. of 16A, SP MCB3 No of 25A, DP MCB3 Nos of 16A, DP MCBin sheet steel enclosure fitted with busbars and neutral links and suitable angle iron frame works with provision for earthing etc. complete. |
| 246 | Run of 2 of 2.5 sq mm PVC unsheathed copper single core cable in PVC pipe for mains with continuous earth connection by 14 SWG wire From the MCB DB to the Switch boards in office, store,and 16A power socket. |
| 247 | Wiring with 2.5 sq mm PVC insulated single core copper cables of 650 V Grade on suitable rigid PVC pipe on wall and ceiling with PVC accessories, with MS switch box covered with 3 mm thick hylam sheet with continous earth wire connection of 14 SWG TC wire. |
| 248 | Light points |
| 249 | Fan Points |
| 250 | Wiring with 2.5 sq.mm PVC unsheathed single core copper cable on suitable rigid PVC pipe for 5A 3 pin CS plug non interlocking including supply and fixing of plug pin top in MS box with continuous earth connection by 14 SWG TC wire. |
| 251 | Wiring with 4 sq.mm PVC unsheathed single core copper cable on suitable rigid PVC pipe for 15A 3 pin CS plug non interlocking including supply and fixing of plug pin top in MS box with continuous earth connection by 14 SWG TC wire. |
| 252 | Lighting Fixtures |
| 253 | Supplying and fixing of 20W 4 Feet LED fitting with LED on ceiling or wall with connection. |
| 254 | Supply and installation of 215 V - 2 x 40 W Flouresent TL fitting industrial type with enamelled reflector complete with all accessories - choke, starter, tube, etc. suitable for wall mounting or roof mounting on conduit tube. |
| 255 | Supplying and fixing of 12\\" sweep AC exhaust fan complete including providing necessary opening in the wall. |
| 256 | Supply and fixing of 48\\" sweep AC ceiling fan complete with regulator with 1m down rod (stem pipe) including supplying and fixing of fan clamp with side plates and cross arms. |
| 257 | a) Supply and erection of 1 No 3\\" dia 2 m long tubular Wall Mounted post with complete 120W LED lamp with necessary fitting and other accessories etc. |
| 258 | Supply and erection of 48W LED Street Light Fitting with LED |
| 259 | Supplying and clamping of PVC , LTUG cable by M.S.clamps on wall for 2 core 4 sq.mm |
| 260 | Suppling and fixing of cable gland and termination with earth connection for 2 core 4 sq.mm |
| 261 | Supply and delivery of the following safety equipment |
| 262 | 5 kg capacity ISI marked dry chemical powder type fire extinguisher |
| 263 | First Aid box ( medium) |
| 264 | Fire bucket - 4 Nos with MS stand |
| 265 | Rubber mat 6mm thick of 1.1 kv grade of size 2m x 1m (5 nos.) confirming to IS |
| 266 | Fire safety rules chart |
| 267 | Shock treatment chart |
| 268 | \\"Caution / Danger\\" Board |
| 269 | Supply and delivery of the following tools: |
| 270 | Double ended open jaw spanner set of size in mm 6x7, 8x9, 10x11, 12x13, 14x15, 16x17, 18x19, 20x22, 20x23 24x27, 25x28 & 30x32 |
| 271 | Ring spanner set of size in mm 6x7, 8x9, 10x11, 12x13, 14x15, 16x17, 18x19, 20x22 20x23 24x27, 25x28 & 30x32. |
| 272 | Screw driver of size 12 inches |
| 273 | Cutting plier of size 8 inches |
| 274 | Tong Tester ( clamp on type- multiutility) A C voltage 0 - 750 V AC current 0 - 1000 A D C voltage 0 - 1000 V Resistance 0 - 40 mega ohms |
| 275 | Electrical tester |
| 276 | Diesel Filling Pump (Hand operated ) |
| 277 | Measuring Dip Rod (MS) (for measuring 200 ltr. standard Barrel ) |
| 278 | Hack Saw frame with blade |
| 279 | Lever type Grease gun |
| 280 | AC Chargeable Emergency Lamp 2 x 11W PL Lamp with all connected accessories |
| 281 | Earthing arrangements with GI Earth Plate including charcoal and salt with necessary excavation in all soils and to full depth as may be required and masonry work, re-filling the sides of foundation with excavated earth as per the standard specification and as directed by the Departmental Officers. |
| 282 | Supply, Delivery, erection, testing and commissioning of PLC Control Panel including the Remote Terminal Unit/ Programmable Logic Controller (RTU/PLC), Human Machine Interface (HMI), GPRS modem, 1 kVA UPS and accessories along with mounting assembly & cables including installing the PLC programming package and interconnecting with the existing SCADA System at Centralized Monitoring Location (the software will be provided by CMWSSB) as directed by Engineer and interconnecting with the ultrasonic level transmitters, electromagnetic flow meters and with existing MV panels, Capacitor panels at each sewage Pumping Station to switch ON/OFF the pumps based on level feedback, Switch ON/OFF the existing capacitor bank to maintain Powerfactor as per EB norms, and to monitor EB/ DG supply including incidental civil works etc., complete. |
| 283 | Supply, Delivery, erection, testing and commissioning of Ultrasonic Level Transmitter of range 0 - 15 meters in the collection well with necessary mounting arrangements including incidental civil works etc complete. |
| 284 | Operation and maintenance of the installation: Operation and maintenanceof the plant with all auxiliary equipment for a period of 120 days after satisfactory supply, erection , commissioning and operating the entire plant for 30 days, free of cost by the contractor before handing over the plant to the Board. |
| 285 | Total excluding GST |
| 286 | GST @18% Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail