| 1 | Taking down Wall panelling and similar work and removing to store complete all as specified and directed. |
| 2 | Providing and fixing Factory Made Single Extruded WPC (Wood Plastic Composite) Panes of 17 mm thickness (Louvers) and the sizes are any of the 150mm, 170mm, 224mm, 300mm (Width) (Colour as approved) with SR 998 adhesive. Panels shall be moisture-resistant, termite-proof, Fire-retardant. All joints, Corners and terminations shall be finished with matching WPC trims and accessories. Work includes surface preparation, edge finishing and accessories such as corner profiles and caps adhesive scaffolding and cleaning of surface after installation, complete in all respects as per drawing and direction. |
| 3 | S&F Solid/ Perforated PVC Wall Lining consisting of 5mm thick Wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame with SR 998 adhesive as per specifications and drawing complete all as specified and directed. (A groove of 2 mm may be left at the joint of two panels for aesthetic look). |
| 4 | S&F in repairs Plain PVC Battons of size 25 mm x 50 mm fixed to the wall using 75 mm long MS screws through the groovein the strip by using PVC fastners. The distance between two screws shall not be more than 200 mm complete all as specified and directed. |
| 5 | S&F Bonded mineral wool/ Glass Wool/ Rockwool blanket slab made from glass density 24 kg/cum and fixed as per manufacturer’s instructions, 25mm thick complete all as specified and directed. |
| 6 | S&F PVC sheet of 5 mm (+/- 0.50 mm) thick PVC strip or channels of width 75 mm feathered at the edges shall be stuck using solvent cement adhesive at the places where two panels are joined, so as to cover the screw of both panels using solvent cement and 90 degree heat bent strips of 5 mm thick PVC sheets of width 75 mm x 75 mm feathered at the edges shall be stuck at wall joints/ pillars etc complete, shade matching to the desired level as per direction of Engr-In-Charge and manufacturer's specifications and drawings. |
| 7 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling with semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225 : 1987, Noncombustible as per BS tiles 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15 x 32 mm of length 3000mm, cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws incl dismantling of old False Ceiling. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 8 | M&L Rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces, second layer (finishing coat) mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement as per manufacturer's instructions and finish the surfaces even and smooth without using extra cement incl taking down old cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water, rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plastering complete all as specified and directed. Note :- (a) Liquid WPC will be measured and paid separately. |
| 9 | Supply only water proofing compound (liquid), ISI marked complete all as specified and directed. |
| 10 | M & L for preparation of newly plastered surfaces of wall & concrete and applying 1mm thick Wall Care Putty including preparation complete all as specified and directed. |
| 11 | M&L for applying two coats of oil bound distemper on wall or concrete over a coat of primer on prepared surfaces including, rubbing with sand paper complete all as specified and directed. |
| 12 | M & L Double charged Light shade/ Dark shade vitrified tiles of size 600 mm x 600 mm and 8-12 mm thick following the specifications as per IS 15622-2006, cut to required size set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles as in floor incl screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying of floor tiles incl dismantling of floor tiles including bedding (but not backing), and rubbish off premises or removed to store complete all as specified and directed. |
| 13 | Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site. |
| 14 | Taking down ceiling fan/ exhaust fan/ wall fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M complete all as specified and as directed. |
| 15 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. |
| 16 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. |
| 17 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- |
| 18 | One light point controlled by one, one way switch 5 Amps |
| 19 | One fan point/ exhaust fan/wall fan point controlled by one, one way switch 5 Amps and regulator |
| 20 | One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 21 | Description all as per item No 17.00 above in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor FRLS PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 22 | Description all as per item No. 17.00 here in before but using 4.0 sq mm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 4.0 sq mm PVC insulated copper conductor FRLS cable as earth continuity conductor along with wiring and connecting to the common eath dolly. (for AC Point) |
| 23 | S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified. |
| 24 | S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified. |
| 25 | S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 26 | S & F for Modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 27 | S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified |
| 28 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit, complete all as specified and directed. |
| 29 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 4 sqmm cable,one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit, complete all as specified and directed. |
| 30 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 31 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 32 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 33 | M&L for single pole and earth encolsure with a two pin and earth plug with socket 240 Volts, 50 Hz complete with onesingle pole MCB SP 20 Amps complete all as specified and directed. |
| 34 | Labour only for refixing the wall fan obtained from item No 2 above including over hauling the fan and cleaning all dust etc and writting the MES Number with synthetic enamel paint complete all as specified and as directed. |
| 35 | M&L for wall fans 450 mm sweep, 230 volts, 50 Hz complete with mounting brackets all as specified and directed |
| 36 | S & F for PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories heavy duty ISI marked of size 20 mm dia for LAN, telephone and TV connections including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed. Please Enable Macros to View BoQ information |