| 1 | Common items for JOB 'A', 'B' & 'C' |
| 2 | M&L for brick work with sub class `B` bricks, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 3 | M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walling built in cement mortar (1:4) complete all as specified and as directed. |
| 4 | M&L for PCC ( 1:4:8 ) Type D -2 using 40 mm graded stone aggregate as in foundation, filling & mass concrete complete all as specified and as directed. |
| 5 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs etc. also splays between floors and beams, etc. rough finished surface of concrete complete all as specified and as directed. |
| 6 | M&L for form work to sides of pillar ,post struts pier column stanchions rough finished surface of concrete complete all as specified and as directed. |
| 7 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in any type of Soil complete all as specified and directed. |
| 8 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and as directed. |
| 9 | Removing excavated material in exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point etc complete all as specified and as directed. |
| 10 | M&L for formwork to Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick rough finished surface of concrete (Horizontal or sloping) complete all as specified and as directed. |
| 11 | M&L for RCC Type B1 (1:2:4) using 20 mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels etc complete all as specified and directed. |
| 12 | All as per BOQ Serial item No 10 above but in column complete all as specified and as directed. |
| 13 | All as per BOQ Serial item No 10 above but as in slabs supported on walls, beams and columns in floors, roofs, laundry, balconies, canopies, deck slab, shelves, etc complete all as specified and as directed. |
| 14 | M&L for Damp proof coarse to horizontal or vertical surfaces including necessary form work in PCC(1:2:4) type B-0 using 12.5 mm graded stone aggregate, 25mm thick complete all as specified and directed. |
| 15 | S&F 110mm bore PVC(SWR) pipe single socket in any length with rubber ring joints complete all as specified and as directed. |
| 16 | S&F 110mm bore PVC(SWR) pipe bend single socket complete all as specified and directed. |
| 17 | M&L for mild steel TMT bars of 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for column, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and as directed. |
| 18 | M&L for mild steel TMT bars of 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length bent to shape required including cranking bending spirally for hooping for column, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and as directed. |
| 19 | M&L for 10mm thick plastering as in ceiling surfaces in CM (1:3) surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 20 | M&L for 15mm thick plastering on fair faces of brick wall and concrete surfaces in CM (1:4) surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 21 | M&L for 15 mm thick rendering on other than fair faces of brick work or concrete surfaces in CM 1:6 surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 22 | Preparing surfaces of new decorated plastered or unplastered surfaces of wall, pillasters, cornices etc and M&L for applying two coats of acrylic distemper with & including 2mm thick wall care putty complete all as specified and directed. |
| 23 | Preparing New decorated plastered or unplastered surfaces of ceiling, pillasters cornices etc and M&L for applying two coats acrylic distemper emulsion over & including a coat of wall care putty complete all as specified and directed. |
| 24 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 25 | M&L for 16 to 18 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like over and including 15mm thick cement mortar bedding (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including dismantling complete all as specified and directed. |
| 26 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. |
| 27 | M&L for broken stone boulders Hard core, broken to gauge n exc 63 mm,deposited,spread and levelled in layered n.exc. 15cm thick, watered and rammed to a true surfaces complete all as specified and as directed. |
| 28 | M&L for 25 mm thick PCC 1:2:4 type B1 using 20 mm graded stone aggregates as in floors finished even and fair surfaces complete all as specified and as directed. |
| 29 | M&L for 75 mm thick PCC 1:4:8 Type D-2 using 40mm graded stone aggregates as in sub base complete all as specified and as directed. |
| 30 | M&L for Providing cement concrete type B-1,1:2:4 using 20 mm graded stone aggregates as in benching concrete, coping , hold fast etc complete all as specified and as directed. |
| 31 | S&F 10mm thick toughened glass for shower Partition openable/ sliding type fixed with stainless steel frame fixing bolts,handle and all necessary fittings complete all as specified and as directed. |
| 32 | Preparation of new steel surfaces of any description over 10cm width or girth and M&L for applying two coats of synthetic enamel paint over & including a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 33 | M&L for 75mm thick cement concrete type C-2 1:3:6 using 40mm graded stone aggregates as in plinth protection, sub base, similar works complete all as specified and as directed. |
| 34 | Demolition of brick work built in cement mortar including all quions, arches, pillers etc complete all as specified and as directed. |
| 35 | Taking down cement plaster including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 36 | Items only for JOB 'A' (B/R Portion) |
| 37 | Dismantiling of Plain or Corrugated, semicorrugated, etc) steel sheeting any gauge, thickness including Nainital or similar pattern in roof coverings and rubbish off the premises (out of MOD land) complete all as specified and as directed. |
| 38 | S&F collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets complete all as specified and as directed. |
| 39 | Preparation of old plastered surface of wall and M&L for applying two coats of oil emulsion distemper over and including a coat of primer and 3mm thick wall care putty on walls complete all as specified and directed. Please Enable Macros to View BoQ information |
| 40 | Preparation of old plastered surface of wall and M&L for applying two coats of oil emulsion distemper over and including a coat of primer and 3mm thick wall care putty on walls complete all as specified and directed. Please Enable Macros to View BoQ information |