Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | APPENDIX A -BUILDING PROPER |
| 2 | 15.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. |
| 3 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 4 | 4.1.8A:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 8 graded stone aggregate 40 mm nominal size Recycled Aggregate (RA) |
| 5 | 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | 5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | OD74960/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess cement used as per design mix is not payable separately. All work above plinth level upto floor V level |
| 8 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 9 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 10 | 5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 11 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 12 | 5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 13 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 14 | 50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 15 | 50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 16 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 17 | 9.119:Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door fame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer's specification and direction of Engineer-in Charge. |
| 18 | 9.120.1:Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of whicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall be tapered in 45 degree on th inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer -in-charge, manufacture's specification & drawing.30 mm thick plain PVC door shutters |
| 19 | 21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 20 | 21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 21 | 21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 22 | 11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 23 | 11.48.4:Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 1000x1000 mm |
| 24 | 13.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm |
| 25 | 9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding |
| 26 | 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 27 | 10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 28 | 10.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 29 | 10.14.1.2:Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm pressed, mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile BFixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 30 | 12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 31 | 12.4.1:Providing ridges or hips width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.80 mm thick with zinc coating not less than 275 gm/m2 |
| 32 | 13.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 33 | OD74961/2025-2026:Supplying and fixing name board of size 40x15 cm acrylic with print pasted from back etc. complete |
| 34 | OD335858/2025-2026:Supplying and fitting stainless steel 3D lettering English or Malayalam of size 25-30cm,30mm projection etc complete as per the direction of engineer in charge at site |
| 35 | OD131016/2025-2026:Providing and fixing 4mm ACP Cladding with aluminium frames complete as per thedirections of Engineer - in - Charge. |
| 36 | 50.12.5.1:Providing and fixing false ceiling with e board classic tile or equivalent make of size 610x610x4 mm ceiling of approved quality in aluminium frame work with necessary screws etc complete ( aluminium frame work shall be paid separately) |
| 37 | 21.2.1:Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side |
| 38 | 16.68:Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 39 | 15.14.2:Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead:Of sectional area below 40 square centimeters |
| 40 | 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar |
| 41 | 15.28.2:Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos cement Sheet |
| 42 | 15.12.1:Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below |
| 43 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 44 | 18.8.4:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal dia pipes |
| 45 | 2.28.1:Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil |
| 46 | 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 47 | APPENDIX B -PLUMBING and SANITARY FITTINGS |
| 48 | 17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid |
| 49 | 17.28.2.1:Flexible pipe32 mm dia |
| 50 | 50.18.7.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall |
| 51 | 50.17.1.1:Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 52 | 17.31:Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 53 | OD74963/2025-2026:Providing and fixing stainess steel grating of approved quality.square type. 125 mm nominal dia with 25 mm waste hole |
| 54 | 50.17.1.3:Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 55 | 50.17.1.5:Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 56 | 50.18.9.4.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.32 mm dia 10.Kgf/cm2 |
| 57 | 18.21.1.1:Providing and fixing uplasticised PVC connection pipe with brass unions:30 cm length15 mm nominal bore |
| 58 | 17.7.1:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 59 | 17.60.2.3:Providing and fixing trap of self cleansing design with screwed down or hinged grating without vent arm complete, including cost of cutting and making good the walls and floors:100 mm inlet and 75 mm outletHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
| 60 | 50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow |
| 61 | 50.18.9.22.3:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow |
| 62 | 50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend |
| 63 | 50.18.9.22.10:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap |
| 64 | 50.18.9.20.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl |
| 65 | 50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee |
| 66 | ELECTRIFICATION |
| 67 | OD193311/2025-2026:Supply and wiring points according to IS 732-1989 using rigid PVC medium conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point |
| 68 | OD193325/2025-2026:Supply and wiring points according to IS 732-1989 using rigid PVC medium conduit ofminimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable sizespecials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitablyand with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650Vgrade, including providing switch board main and continuous earthing with 1.50 sq mm greencoloured FRLS PVC insulated stranded single core copper conductor cable 650V grade,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc completewith suitable size modular type metal switch boxes, modular type front plates (white) etc. up toand including 6A modular type SP switches and making good the surface of wall, colourwashing etc. complete. All the terminations in the switch boards and DB's shall be tinned andthe wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mountsetc as required. (RoHS compliant modular accessories). Single control light point withoutceiling rose - Short point |
| 69 | OD193327/2025-2026:Supply and wiring points according to IS 732-1989 using rigid PVC medium conduit ofminimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable sizespecials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitablyand with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650Vgrade, including providing switch board main and continuous earthing with 1.50 sq mm greencoloured FRLS PVC insulated stranded single core copper conductor cable 650V grade,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc completewith suitable size modular type metal switch boxes, modular type front plates (white) etc. up toand including 6A modular type SP switches and making good the surface of wall, colourwashing etc. complete. All the terminations in the switch boards and DB's shall be tinned andthe wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mountsetc as required. (RoHS compliant modular accessories). Single control light point withoutceiling rose - Short point |
| 70 | OD193336/2025-2026:Supply and wiring points according to IS 732-1989 using rigid PVC medium conduit ofminimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable sizespecials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitablyand with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650Vgrade, including providing switch board main and continuous earthing with 1.50 sq mm greencoloured FRLS PVC insulated stranded single core copper conductor cable 650V grade,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc completewith suitable size modular type metal switch boxes, modular type front plates (white) etc. up toand including 6A modular type SP switches and making good the surface of wall, colourwashing etc. complete. All the terminations in the switch boards and DB's shall be tinned andthe wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mountsetc as required. (RoHS compliant modular accessories). Single control light point withoutceiling rose - Short point |
| 71 | OD193342/2025-2026:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specialsconforming to IS 3419-1988, fixing the conduit concealed suitably and with 1.50 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch board main and continuous earthing with 1.50 sq mm FRLS PVC insulated strandedsingle core copper conductor cable 650V grade etc complete with suitable size modular typemetal switch boxes, modular type front plates (white) etc. up to and including 6A modular typeSP switches and making good the surface of wall, colour washing etc. complete. All theterminations in the switch boards and DB's shall be tinned and the wires shall be drawn andfixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHScompliant modular accessories).Independent plug - Short point |
| 72 | OD194098/2025-2026:Supply & installation of light fittings on 'C/U' shaped flat iron bracketSupply, conveyance, installation, testing and commissioning the light fittings of following typesmade from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wallusing 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket andgiving connections with required length of 16/0.20mm 3 core copper conductor flex wireconforming to relevant ISS or extending the original wiring and giving connection etc. asrequired.1200 mm 1X20W LED Lamp with box type fixture |
| 73 | OD194127/2025-2026:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape /cut and welded to shape and fixing the same to wall / parapet using clamps as noted along witheach size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer,making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps |
| 74 | OD194286/2025-2026:Supply Conveyance, installation, testing and commissioning of 20W LED street light outputgreater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip makeCree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protectionup to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover completewith THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up foruse on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chipmanufacturer) |
| 75 | OD193345/2025-2026:Supply and installation of compact modern design utility bulkhead with energy savingsCrompton STUD type 10W LED fitting |
| 76 | OD193470/2025-2026:Supplying and fixing PVC batten/ angle holder with PVC shade, 9W LED bulb and givingconnection etc. as required. |
| 77 | OD194292/2025-2026:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light outputgreater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip makeCree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protectionup to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover completewith THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for useon 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM79&80 certificates from NABL accredited Third party lab to be produced mentioning chipmanufacturer) |
| 78 | OD193484/2025-2026:Supply, Installation, testing and commissioning of ceiling fan of following sizes includingwiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated,copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan 3 star rated, complete with service value minimum 5.0(cubmeter/minute/Watt), Air delivery minimum 215(cubic meter/minute), Copper winding suitablefor 230V/240V single phase AC supply |
| 79 | OD194307/2025-2026:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 asrequired. |
| 80 | OD194305/2025-2026:Supplying and providing extra H.G conduit down rod of 19 mm dia 2 x 1.00 m long with16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extendedoriginal wiring and giving connection etc. as required. |
| 81 | OD194309/2025-2026:Supplying and fixing of following sizes of medium class PVC conduit along with accessories insurface/ recess including cutting the wall and making good the same in case of recessed conduitas required.20 mm |
| 82 | OD194313/2025-2026:Supplying and fixing of following sizes of medium class PVC conduit along with accessories insurface/ recess including cutting the wall and making good the same in case of recessed conduitas required.25 mm |
| 83 | OD194316/2025-2026:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate formodular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 84 | OD194323/2025-2026:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate formodular switches in recess etc as required.3 Module (100mmX75mm) |
| 85 | OD194331/2025-2026:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate formodular switches in recess etc as required.6 Module (200mmX75mm) |
| 86 | OD194334/2025-2026:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single corecable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 87 | OD194337/2025-2026:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single corecable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 88 | OD194345/2025-2026:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single corecable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm |
| 89 | OD194347/2025-2026:Supplying and fixing following modular switch/ socket on the existing modular plate & switchbox including connections but excluding modular plate etc. as required.5/6 amps switch |
| 90 | OD194353/2025-2026:Supplying and fixing following modular switch/ socket on the existing modular plate & switchbox including connections but excluding modular plate etc. as required.15/16 amp switch |
| 91 | OD194358/2025-2026:Supplying and fixing following modular switch/ socket on the existing modular plate & switchbox including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 92 | OD194372/2025-2026:Supplying and fixing following modular switch/ socket on the existing modular plate & switchbox including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 93 | OD194376/2025-2026:Supplying and fixing following modular switch/ socket on the existing modular plate & switchbox including connections but excluding modular plate etc. as required.TV antenna socket outlet |
| 94 | OD198571/2025-2026:Supplying and fixing modular blanking plate on the existing modular plate & switch boxexcluding modular plate as required. |
| 95 | OD194425/2025-2026:Supplying and fixing following Modular base & cover plate on existing modular metal boxesetc. as required.6 Module |
| 96 | OD193499/2025-2026:Supply, testing and installation of Jack Cat6 Keystone UTP with Collapsible Shutter-WhiteMake - D Link NKJ-C6WHI1B21 or equivalent |
| 97 | OD194434/2025-2026:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessedsteel/PVC conduit as required1 run of Cable |
| 98 | OD194438/2025-2026:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along withthe following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation asrequired.100 x 50 mm CMS with base and lid |
| 99 | OD198570/2025-2026:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along withthe following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation asrequired.Cable devider |
| 100 | OD202430/2025-2026:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lidalong with the following accessories conforming to IEC 61084/ BS 476 & 4678 onsurface / recess including cutting the wall and making good the damages in case ofrecessed installation as required.External angle 90 degree |
| 101 | OD194919/2025-2026:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along withthe following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation asrequired.Flat angle 90 degree |
| 102 | OD194920/2025-2026:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along withthe following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation asrequired.Internal angle 90 degree |
| 103 | OD194923/2025-2026:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along withthe following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation asrequired.Flat cross |
| 104 | OD194927/2025-2026:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along withthe following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation asrequired.End cap |
| 105 | OD194948/2025-2026:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along withthe following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation asrequired.Joint cover |
| 106 | OD194949/2025-2026:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along withthe following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation asrequired.Cable retainer |
| 107 | OD194950/2025-2026:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along withthe following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation asrequired.1 to 3 module mounting box |
| 108 | OD194953/2025-2026:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN railsuitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed inrecess including cutting hole on the wall , making good the damages, colour washing etc. asrequired4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 109 | OD194955/2025-2026:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 110 | OD194968/2025-2026:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. asrequired. |
| 111 | OD194973/2025-2026:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DBcomplete with connections, testing and commissioning etc. as required.40 amps |
| 112 | OD194974/2025-2026:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 113 | OD193511/2025-2026:I T C of Fire Extinguisher dry chemical powder (ABC) Stored pressure type 4 kg capacity asper IS:15683 with ISI mark and with initial charger and installation brackets |
| 114 | OD193517/2025-2026:Painting letters or figures of 4.5cm / 2.5cm sizes with enamel paint or printing letters or figuresof 4.5cm / 2.5cm sizes with superior quality sticker as identification mark to each compartmentsof DG Set, Panel Boards, Enclosures, Distribution Boards etc. complete as required |
| 115 | OD193523/2025-2026:Supply, installation, testing and commissioning of 200 Litre capacity Solar Water Heater havingthe specifications of Diameter of Outer tank 480mm, Thickness of Insulation layer 50mm,Density of PUF Insulation 35 to 40kg/m3, Material of Outer Cylinder Zinc-Alum Sheet,Material of Inner Tank SS 304 L, Quantity of Vacuum Tube 20 Nos, Vacuum Tube Diameter58mm, Vacuum Tube Length 1800mm, Material of Stand GI Plus Powder Coating, AbsorbingArea 3.3m2, Angle of Stand 25Degree, Corrosion Protection Mg Anode, Inlet Pipe (Left Bottom) 3/4 Inch BSP Nos, Outlet(Right Top) 3/4 Inch BSP Nos etc. The scope also includes providing M.20 Grade (1:1.5:3)PCC concreating works of base of structures etc. and also the supply and installation of WaterHeater pipe line systems using up to and including 25mm size of CPVC SDR 11 Pipe with allnecessary accessories like couplings, elbows, tees, valves, solvents, Stainless Steel clamps,screws and taps etc. complete as required as per the local site conditions |
| 116 | OD193580/2025-2026:Supply, unloading, installation, testing and commissioning of 25 kVA Diesel Generator Setwith Acoustic Enclosure conforming to CPCB IV+ norms. The DG Set shall have thespecifications as follows:-ENGINEDiesel Oil Engine with direct injection, 4 stroke vertical in line cylinders, liquid cooled withspecified shaft output after reduction of power for engine Auxiliaries and when operating at agoverned speed of 1500 RPM at NTP condition. The engine shall be suitable for continuous duty and shall conform to IS 10000 or other necessary standards as required. The engine shallbe with Optimal Operating Efficiency that gives low emission and high efficiency. The engineshall be with all standard specifications, accessories, fittings etc. complete as requiredALTERNATORSelf-excited, self-regulated, screen protected, drip proof alternator with static excitation system,capable of developing rated output at 415 V, Power Factor 0.8, Frequency 50 Hz when runningat 1500 RPM at NTP conditions and conforming to IS 4722. The Alternator shall be equippedwith special windings to reduce harmonics and the same shall be made with Vacuum PressureImpregnation and epoxy gel coating etc. complete as requiredCONTROL PANELFloor mounting sheet steel construction fabricated out of 1.6 mm sheets and with one / twohinged front doors of 2 mm sheet steel bolted back / sides, totally enclosed and vermin proofwith the following components.1 Nos - Genset Controller having Alternator parameters like Voltage, Frequency, Amps, KW,kVAR, PF etc.3 Nos - Required CL:1 CT1 Nos - Three Phase 4 Wire KWH Meter1 Set - Aluminium / Copper Busbars of Required Rating2 Nos - Indicating lamps showing SET RUNNING and SET ON LOAD1 Nos - 10kA 4P C Curve MCB3 Nos - Instrument Fuses2 Nos - Earthing Studsetc. complete as requiredACOUSTIC ENCLOSUREFabricated out of 16 SWG CRCA MS sheet with nut bolt type construction, Powder coatingshall be done after seven-tank surface preparation process of sheet metal, Canopy panel anddoors shall have inside lining of Fire Retardant foam as acoustic material, four hinged doorsshall be provided to canopy, one door shall have glass window for control panel etc. completeas requiredNOISE LEVEL75 DB at 1 metre from the enclosure surface under free field conditions as per CPCB Normsetc. complete as requiredBASE FRAMEFabricated in sheet metal, rugged in construction, designed for mounting engine and alternatorclose coupled, with cross members mounted on AVM, having provision for mounting ofacoustic enclosure, lifting hook for convenient lifting of complete set, i.e., along with canopy,engine and alternator etc. complete as requiredFUEL TANKRemovable type fuel tank with 8 hours full load running capacity fabricated out of CRCA MSsheet duly painted and fitted with inlet and outlet connections etc. complete as requiredACCESSORIES1 Nos - Dry 12V Battery1 Nos - Battery Charger1 Set - Battery Leads1 Nos - Exhaust Expansion Bellowetc. complete as requiredREMOTE MONITORING SYSTEMDG Set shall be linked with a central monitoring data server through SIM and internet in orderto view all critical indicators on mobile or laptop with alarms etc. complete as requiredThe scope also includes the testing of Energy Meter etc. and obtaining Test Certificates fromElectrical Inspectorate (*All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents).The DG Set shall be provided with a standard warranty of 24 months. The scope also includesproviding AMC for a period of 5 Years from the date of installation and commissioning with aminimum of 4 visits per year for necessary checking and for doing any preventive maintenanceworks (excluding any material charges) |
| 117 | OD193959/2025-2026:Supply, installation, testing and commissioning of Wall Mounting Cubical Type ATS Enclosuresuitable for 415 V, Three Phase, 4 Wire 50 Hz AC supply system having sufficient front surfacearea fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frameworks and covers, 2 mm thick for gland plates, cleaning and finishing complete with 7 tankprocess for Powder Coating in approved shade and then provided with Clear Coating, having 63Amps capacity type TPN Aluminium alloy / Copper busbars of high conductivity, DMC / SMC/ FRP busbar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., fabricationshall be done in transportable sections, entire panel shall have a common copper earth bar ofsize 20 mm x 3 mm at the rear with 2 Nos. earth stud, solid connections from main busbars toswitch gears with approved size of Aluminium busbars and control wiring with 2.5 / 1.5 Sq.mmFRLS (Flame Retardant Low Smoke) or HRFR (Heat Resistant Flame Retardant) PVCinsulated single core copper conductor cables, cable alleys etc. complete as required. TheEnclosure shall conform to the Electrical Inspectorate standards and it shall only bemanufactured after getting approval from the Engineer-in-charge.EB INCOMER SIDE1 Set - RYB Indication Lamps with Control MCBs1 Nos ? 63A 10kA 4P C Curve MCB1 Nos - 2A/4A 10kA DP C Curve MCB (For DG Set Battery Charging)DG INCOMER SIDE1 Set - RYB Indication Lamps with Control MCBs1 Nos - 32A 10kA 4P C Curve MCBAUTOMATIC TRANSFER SWITCH1 Nos - 63A 4P Automatic Transfer Switch with InterlockATS shall have the specifications of AC 33B Utilization Category, Solenoid Drive, IntegratedController Type, Three-Position, Specific Transfer Switching Equipment, Generator Start-StopModule with Control Function, Provision to add Auxiliary Contacts to indicate mechanicalpositions if necessary, conforming to IEC 60947-6-1 with CE, CB and RoHS Certification etc.complete as requiredSURGE PROTECTION DEVICE2 Nos - Provision for fixing 4 Module DIN Rail Mounting Type 1 + Type 2 / Class 1 + Class II100kA SPD on the Incoming / Outgoing Side of EB INCOMER and DG INCOMER along withGreen and Red Indication Lamps with Control MCBs [The connections to RYB Phases, Neutraland Earth shall be done using 16 Sq.mm FRLS (Flame Retardant Low Smoke) or HRFR (HeatResistant Flame Retardant) PVC insulated single core copper conductor cables with less than0.45m in length]OUTGOING1 Nos - 63A 10kA 4P C Curve MCB |
| 118 | OD193960/2025-2026:Supply and laying of XLPE insulated and PVC sheathed armoured Aluminium power cable of1.1 kV grade of the following sizes in the existing excavated trenches, built up trenches andpulling through existing pipes including all minor civil works etc. complete as required4 Core 25 Sq.mm |
| 119 | OD194977/2025-2026:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminiumpower cable, 1.1 KV grade of the following sizes using clamps noted along with the cables,spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. asrequired.4 core 35 sq mm with factory made clamp |
| 120 | OD198968/2025-2026:Supply and laying of XLPE insulated and PVC sheathed armoured Copper power cable of 1.1kV grade of the following sizes in the existing excavated trenches, built up trenches and pullingthrough existing pipes including all minor civil works etc. complete as required4 Core 2.5 Sq.mm |
| 121 | OD193972/2025-2026:Supply, laying and clamping of 1 no. XLPE insulated and PVC sheathed armouredCopper power cable, 1.1 kV grade of the following sizes using clamps noted alongwith the cables, spacing of clamps not exceeding 60cms, making good the damages,colour washing etc. complete as required2 Core 2.5 Sq.mm with factory made clamp |
| 122 | OD194984/2025-2026:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminiumpower cable, 1.1 KV grade of the following sizes using clamps noted along with the cables,spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. asrequired.4 core 25 sq mm with factory made clamp |
| 123 | OD201774/2025-2026:Supply and laying of XLPE insulated and PVC sheathed armoured Copper power cable of 1.1kV grade of the following sizes in the existing excavated trenches, built up trenches and pullingthrough existing pipes including all minor civil works etc. complete as required2 Core 2.5 Sq.mm |
| 124 | OD201782/2025-2026:Supply, laying and clamping of 1 no. XLPE insulated and PVC sheathed armoured Copperpower cable, 1.1 kV grade of the following sizes using clamps noted along with the cables,spacing of clamps not exceeding 60cms, making good the damages, colour washing etc.complete as required4 Core 2.5 Sq.mm with factory made clamp |
| 125 | OD194993/2025-2026:Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KVgrade as required.4 X 35 sq. mm (32mm) |
| 126 | OD194996/2025-2026:Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KVgrade as required.4 X 25 sq. mm (28mm) |
| 127 | OD193987/2025-2026:Supply and providing gland earthing using Gland Earthing Clips / Clamps for following size ofPVC insulated and PVC sheathed / XLPE Aluminium conductor cable of 1.1 kV grade etc.complete as required4 X 25 Sq.mm |
| 128 | OD193975/2025-2026:Supplying and making end termination with brass compression gland and Copper lugsfor the following size of PVC insulated and PVC sheathed / XLPE Copper conductorcable of 1.1 kV grade etc. complete as required4 X 2.5 Sq.mm |
| 129 | OD193978/2025-2026:Supplying and making end termination with brass compression gland and Copper lugs for the following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 kVgrade etc. complete as required2 X 2.5 sq.mm |
| 130 | OD193979/2025-2026:Supply and providing gland earthing using Gland Earthing Clips / Clamps for following size ofPVC insulated and PVC sheathed / XLPE Aluminium conductor cable of 1.1 kV grade etc.complete as required4 X 35 Sq.mm |
| 131 | OD193988/2025-2026:Supply and providing gland earthing using Gland Earthing Clips / Clamps for following size ofPVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 kV grade etc.complete as required4 X 2.5 Sq.mm |
| 132 | OD198673/2025-2026:Supply and providing gland earthing using Gland Earthing Clips / Clamps for following size ofPVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 kV grade etc.complete as required2 X 2.5 Sq.mm |
| 133 | OD194011/2025-2026:Excavation of all types of soils for the laying of PVC insulated and PVC sheathed / XLPEAluminium or Copper conductor cable, GI / DWC HDPE / RCC / PVC / Conduit Pipes,Earthing conductors to the required width and depth up to and including 1.2m and back fillingetc. complete as required. (The trench dimensions and specifications shall conform to CPWD /PWD, Electrical Inspectorate and KSEBL Standards) |
| 134 | OD198715/2025-2026:Supply and providing sand cushioning by laying it above the PVC insulated and PVC sheathed /XLPE Aluminium or Copper conductor cable, GI / HDPE / RCC / PVC / Conduit Pipes,Earthing conductors in the existing excavated trench etc. complete as required |
| 135 | OD194018/2025-2026:Supply and providing protective covering by laying bricks breadth wise above the PVCinsulated and PVC sheathed / XLPE Aluminium or Copper conductor cable, GI / HDPE / RCC /PVC / Conduit Pipes, Earthing conductors in the existing excavated trench etc. complete asrequired |
| 136 | OD194020/2025-2026:Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe including charcoal/coke and salt etc. complete as required |
| 137 | OD194022/2025-2026:Supply of Stainless Steel 304 Grade 6mm x 3 Inch bolt and its nut, spring washer and doubleround washers etc. complete as required |
| 138 | OD195003/2025-2026:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cablesand giving connection as required4.75 mm copper conductor (6 SWG) |
| 139 | OD195018/2025-2026:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cablesand giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 140 | OD195021/2025-2026:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) |
| 141 | OD195038/2025-2026:Supply of superior quality copper earth socket for the following size of earth conductorincluding crimping etc. as required.3.15 mm (10 SWG) |
| 142 | OD194026/2025-2026:Supply and installation of Tinned Stainless Steel Earth Bench / Terminal Strip of 10Poles or12 Poles manufactured in accordance with IS / IEC 62305-3:2010 and IEC62561-2:2012 with Stainless Steel bolts, nuts, round and spring washers or screws etc.The Terminal Strip shall have the specifications of minimum Width 25mm, Thickness4mm, insulations provided at mounting ends etc. complete as required |
| 143 | OD194410/2025-2026:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module |
| 144 | OD194030/2025-2026:Supply, fabrication and installation of Panel Board / ATS Enclosure / DG Set Exhaust Pipingmounting supports or Cable Tray and supports using MS Angles, Flats and C Channels ofadequate size painted with two coats of epoxy primer and two coats of black / grey / otherapproved shade epoxy paint. The scope also the includes the supply and installation ofnecessary rectangular / square plates, anchor fasteners, bolts, nuts, round and spring washers orscrews etc. complete as required |
| 145 | OD194031/2025-2026:Supply and providing Extension of DG Exhaust Pipeline using the following sizes of B ClassMS pipes with all required accessories like bends, coupling, flanges, flexibles, bolts, nuts, roundand spring washers or screws etc. using already fabricated and duly painted existing MSStructural supports etc. and painting the same using 600 Deg.C Heat Resistant Aluminiumpaints etc. complete as requiredUp to and including 100mm dia |
| 146 | OD195088/2025-2026:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, atleast 2 mm thick, and vitreous enameled white on both sides, and with inscription in single redcolour on front side as required. |
| 147 | OD194040/2025-2026:Preparation and submission of Completion Report, Arranging Inspection and obtaining Sanctionfor Energization of 25 kVA DG Set and all other existing installations from ElectricalInspectorate. (*All Statutory fees shall be remitted by the Client / Consumer or it shall bereimbursed on the submission of supporting documents) Please Enable Macros to View BoQ information |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail