Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-04-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-04-2026 |
| 2 | 23-03-2026 | CorrigendumNo1 | BOQ | 02-04-2026 |
| 3 | 23-03-2026 | CorrigendumNo1 | BOQ | 09-04-2026 |
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.complete all as directed. |
| 2 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness.(below or above ground level) Complete all as specified and directed. |
| 3 | Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water etc.&removing rubbish to a disance not exc 250m Complete all as specified and directed. |
| 4 | Demolition brick work or stone/ boulder masonery built in cement mortar including all quoins , pillars etc |
| 5 | Taking down chowkhat or frames with shutters not exc. 1.5 sqm each complete all as specified and directed. |
| 6 | Taking down chowkhat or frames with shutters exc. 1.5 sqm but not exc. 4 sqm each complete all as specified and directed. |
| 7 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store. |
| 8 | Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store. |
| 9 | Dismantling of ceiling board (flbre pulp, insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets complete all as specified and directed. |
| 10 | Dismantling plain or corrugated steel sheeting any guage, thickness, including Nainital pattern or similar pattern roof covering complete all as specified and directed. |
| 11 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. |
| 12 | Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for. (reinforcement cut as required to facilitate demolition) |
| 13 | M & L for non skid ceramic coloured /printed tiles 7 to 8 mm thick (square / Rectangular)area of each tiles not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles. |
| 14 | M & L for non skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match , in floors etc set and jointed in neat cement slurry and pointed in white or coloured cemet to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 15 | M & L for non skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match , in skirting/ dado etc set and jointed in neat cement slurry and pointed in white or coloured cemet to match including incl rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 complete all as specified and directed. |
| 16 | M & L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 15mm thick screed bed in CM 1:6 complete |
| 17 | M & L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing incl rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4complete |
| 18 | M&L 20 mm thick granite stone on steps including rubbing and polishing and making hole for gas pipe and front portion rounded and chamfered complete including screed bedding 15 mm thick in CM 1:4 complete all as spd |
| 19 | M & L for glazed ceramic coloured / printed tiles 300mm x 450mm, 6 to 7mm thick, on vertical surfaces set and jointed in neat cement slurry and pointed in white/ coloured cement to match the tiles, incl rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 complete all as specified and as directed. |
| 20 | M & L for 75 mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in plinth protection finishing the surface even and smooth without using extra cement Complete all as specified and directed. |
| 21 | M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in CM (1:6) complete al as specified |
| 22 | M&L for rendering 15 mm thick readymade plaster on inner/outer walls by adding 17-19% of potable water by weight of material for thickness above 15mm it is recommended to be applied in multiple layers. ready mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the compressive strength @ 28 days 10-12 Mpa/Bulk density 1500-1600 Kg/m3. (Note : The rate quoted by contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20 Mtr ht all as specified and directed) |
| 23 | M & L Type B1 1:2:4 (20mm graded aggregate)for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like |
| 24 | Formwork to rough finished surface of concrete soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) |
| 25 | M & L for TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 26 | M&L for Pressed steel frames 105X60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.,supplied and fixed complete all as specified and directed. |
| 27 | M&L for Pressed steel frames 125X60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.,supplied and fixed complete all as specified and directed. |
| 28 | S&F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed |
| 29 | S & F 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., rs, edges of framing plain, chamfered complete all as specified and directed. |
| 30 | M/L for 18/19 Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screwscomplete all as specified and directed. |
| 31 | S&F of powder coated aluminium grid frame work for false celling comprising of the following sections for making partitions of 600x600 mm size fixed to walls with rawl plugs & screws and hanged to roof with and including 4mm dia GI wire suspender of suitable length and butterfly clips, size of main tee shall be 28mmx24mmx0.3mm thick , cross tee shall be 28mmx24mmx0.3mm thick and wall angle shall be 24mmx24mmx0.3 mm thick incl 4 mm thick E-Board Classic (Make-Everest) for insulation and accoustic purpose, 595 x 595 mm size fixed with staples on snap grid as in ceiling with and including dusting of surface complete all as specified and directed.complete all as specified and directed. |
| 32 | S&F 0.63mm thick galvanised corrugated MS sheeting (CGI sheet roofing) with two corrugation side laps, with 120gm Zinc (Spelter) coating per Sqm both sides inclusive fixed with L-type or J-type hooks bolts as in roofs etc all as specified |
| 33 | All as per item No 32 above but fixing only CGI sheets |
| 34 | S&F 0.63mm thick plain galvanised MS sheeting using grade-O sheets with 120gm Zinc (Spelter) coating Per Sqm both sides inclusives, as in roof, ridges, hips, valley gutters, drip and straight flashing complete all as specified and directed. |
| 35 | S&F Factory made precoated steel window and vents (Box Section) with glass shutter and fly proof shutter incl guard bars as per HQ CEBZ Drg No TD/158 of sh 1/2 & 2/2 with and including all precoated fittings .NOTE: (i) Payment under this item will be make combined for steel frames, steel shutters and Guard bard/Grill, However unit rate quoted shall deemed to include cost of beading, fittings such as handles, hinges,Telescopic stays, locking arrangements and fixing of glass and wiremesh etc.(ii) Supply only 4 mm thick sheet glass and stainless steel wire mesh be measured and paid separately. (iii) Weight of Grill/Guard Bars, handle,hinges and locking arrangements shall not be accounted for payment purpose . |
| 36 | S & F 150 mm long Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed. |
| 37 | S & F floor door stopper of chromium plated body with rubber shoe fixed in door, overall length of cover plate 140 mm all as specified and directed. |
| 38 | S & F butt hinges, medium weight, Miled steel and fixed, size of hinges 100mm complete all as specified and directed. |
| 39 | S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 40 | S & F 100 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 41 | Supply and fix 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed. |
| 42 | S & F in Repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with Stainless steel wire staples. |
| 43 | S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with Stainless steel wire staples. |
| 44 | Supply only Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 45 | Hacking out old broken glass ( any thickness ) size or description from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads |
| 46 | S & F 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 47 | Supply only4mm thick sheet glass ordinary quality and glazing with oil putty in square/rectangular n.exc 0.50 sqm in each panes. |
| 48 | Cutting chases, for water tubing or concealed , etc, and making good to facings where required and plastering in cement mortar (1:3) cutting not exceeding 10cm girth in brick walls complete all as specified and directed. |
| 49 | S&F GI water tubing of 15mm dia ,medium grade conforming to IS-1239(Part -1) including all fittings such as bends,tees, short pieces, connectors, elbows, reducers, union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed. |
| 50 | Fixing only GI water tubing of 15mm dia ,medium grade conforming to IS-1239 (Part -1) including all fittings such as bends,tees,short pieces, connectors, elbows, reducers,union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed. |
| 51 | S&F GI water tubing of 20 mm dia ,medium grade conforming to IS-1239(Part -1) including all fittings such as bends,tees,short pieces, connectors, elbows, reducers, union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed. |
| 52 | Fixing only GI water tubing of 20 mm dia ,medium grade conforming to IS-1239 (Part -1) including all fittings such as bends,tees,short pieces, connectors, elbows, reducers, union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed. |
| 53 | S&F in repairs stop valves/angle valves, cast copper alloy, fency type chromium plated , screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore dia of pipe. |
| 54 | S & F in repairs 15 mm bore Fancy type pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed. |
| 55 | S&F 32mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed. |
| 56 | S & F in repairs bib taps, cast copper alloy, 15 mm dia, Chromium Plated, fancy type with crutch or butterfly handle, screwed down for iron pipe and fixed etc complete all as specified. |
| 57 | S&F in repairs vitreous China wash down water closet (Orrissa pattern , white (excluding flushig cistern and flush pipe) and connection to drain or out going pipe and flushing pipe. |
| 58 | S&F in repairs Gun-metal, globe or gate valves 15 mm, with iron wheel head, screwed both ends for iron pipe and fixed |
| 59 | S&F in repairs Gun-metal, globe or gate valves 20 mm, with iron wheel head, screwed both ends for iron pipe and fixed |
| 60 | S & F in repairs 10 Liters capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia including brackets and connections to pipe complete all as specified and as directed. |
| 61 | M & L for 32mm bore high density polyethylene pipes (HDPE) complete all as specified and directed. |
| 62 | S & F vitreous china wash basin, white, flat back, size 550mm x 400mm, (flat back or angle back type) including brackets and including cutting for and pinning in ends of brackets or erecting stand, fixed in repairs. |
| 63 | S&F, 5.50 mm thick looking Mirror of selected quality glass, size 600mm x 450mm, mounted on 6mm thick commercial plywood and fixed to wooden plug with C.P. brass screws and cup washers with & including plastic fancy frame alround all as directed. |
| 64 | M&L for PVC (SWR) pipes 110 mm single socketed, in any length with rubber ring joints, fixed to walls |
| 65 | S & F in repair PVC (SWR) 110 mm pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 66 | M&L for PVC (SWR) floor trap 75 mm, plain with grating including jointing with solvent cement complete all as specified and directed |
| 67 | M&L for PVC (SWR) pipes 110 mm single socketed, in any length with rubber ring joints, fixed to walls |
| 68 | S & F in repair PVC (SWR) 75 mm pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 69 | S & F 75 bore PVC (SWR) bends any radius complete all as specified and directed. |
| 70 | S & F PVC (SWR) junction single 75mm , (Single T) equal or unequal complete all as specified and directed. |
| 71 | S & F PVC (SWR) vent cowls 110mm dia complete all as specified and directed.. |
| 72 | S&F brass chromium plated tubular towel rail, 20 mm dia, D; type, 60 cm long between flanges complete all as specified and directed. |
| 73 | S&F chromium plated Soap disk fixed to plug with chormium plated brass screws all as specified and directed |
| 74 | S & F 20mm Dia Aluminium alloy anodised curtain rod decorative fency type with brackets complete all as specified. |
| 75 | S & F PVC connections 15mm dia , 450mm long, , with PTMT nuts & washers at both ends |
| 76 | Dismantling water tanks 500 ltrs capacity complete all as specified and directed. |
| 77 | Dismantling water tanks of any description, capacity exceeding 500 litres but not exceeding1000 liters complete. |
| 78 | S&F rotational moulded polythene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in postion 500 ltrs capacity and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram of Make - Prayag complete all as specified and directed. |
| 79 | S&F rotational moulded polythene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in postion 1000 ltrs capacity and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram of Make - Prayag complete all as specified and directed. |
| 80 | M & L for providing plain cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in coping, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 81 | M & L for painting to new wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of pink primer including preparation of surfaces. |
| 82 | M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed. |
| 83 | M & L for Old painted surface to steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described with one coats of synthetic enamel including preparation of surfaces complete all as specified and directed. |
| 84 | M & L for newly painting to steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified and directed. |
| 85 | M/L for preparing newly plastered wall surfaces and applying two coat of distemper oil emulsion over a coat of primer(Priming the plastered and other surface preparatory to distempering) complete all as specified and directed. |
| 86 | Material & Labour for applying Two or more coats of 100% remium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including primingcoat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified and directed. |
| 87 | M/L for complete removal of existing treatment and applying Two or more coats of 100% remium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including primingcoat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified and directed. |
| 88 | M/L for complete removal of existing treatment for preparing old painted surfacess and applying two coat of distemper oil emulsion over a coat of primer complete all as specified and directed. |
| 89 | M&L for applying 2 mm thick layer of wall care putty on wall surfaces including cornics etc for proper levelling of plaster complete all as specified and directed |
| 90 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in Hard/ Dense soil complete all as specified and directed. |
| 91 | Demolition and breaking up drain pipes 150 mm (salts glazed ware ,AC or Reinforced concrete) set in cement mortar all as specified |
| 92 | M & L DWCPE (SN8) 180 (OD)/163(ID) mm diameter Pipes laid in trenches and jointed as required complete all as specified and directed. |
| 93 | M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150mm bore complete all as specified and directed. |
| 94 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed. |
| 95 | Removing Excavated soil exceeding 250 M but not exceeding 500 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed. |
| 96 | M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed |
| 97 | M&L for providing precast cement concrete 1:2:4 type B1 (20mm graded aggregate) as in cover slab for manholes complete all as sp[ecified and directed |
| 98 | M & L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 99 | M/LCement concrete 1:3:6 type C-1 using 20mm graded stone aggregate in surface channels and drains complete. |
| 100 | M/L Cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate in cills, seismic and other similar bands, plinth courses, copings, bed plates, bond stones, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete. |
| 101 | Extra for forming fair finished drain or channel 30 cm inner girth in cement complete all as specified and directed. concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc.All as specified and directed. |
| 102 | M&L 75 mm thick cement concrete 1:4:8 type D-2 finished fair and even as in sub base Complete all as specified and directed. |
| 103 | M & L for sand filling under floors or in foundation incl watering and consolidation complete all as specified |
| 104 | M&L for machine presed precast interlocking paver block any shape & size confirming to IS 15658-2006 of 60mm thickness M-35 grade with grey cement and pigments complete all as specified |
| 105 | Taking down carefully Aluminium/copper wiring of any size (for light, fan, socket or power etc complete) ( fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc to be measured and paid separately) and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed. |
| 106 | M & L point wiring for Modular fittings for one light point/ fan/ bell/ 5Amps socket out let (independent)point controlled by one, one way switch with 1.5 sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FR-LSH) PVC cable drawn into & including medium grade PVC conduit (not less than 20mm outer dia )with all fittings and accessories fixed concealed (including chase cutting in brick/ stone masonry walls for fixing conduit and plastering and whitewash/colouring the external surface and matching the same with existing surface) incl modular metal flush box for mounting modular fittings and covered with modular cover plate with frame and cup washers including one continuous run of PVC insulated (green colour) 1.5 Sqmm multistranded copper conductor cable earth wire and connected to earth dolly complete all as specified and directed. One light/One fan/one bell point controlled by one modular switch |
| 107 | One modular socket outlet 3 pin 6 amps controlled by one switch on same board. |
| 108 | One modular socket outlet 3 pin 6 amps controlled by one switch on independent board. |
| 109 | All as per item No 2 herein before but wiring with 2.5 sqmm copper wire (FR-LSH) PVC and 2.5 sqmm earth wire for modular socket outlet 5 pin 16 amps on independent board. |
| 110 | Supply and fix modular type switch single pole, one way 6 Amp complete all as specified and directed. |
| 111 | Supply and fix socket out let multi 5 pin, 6 Amps, modular type complete all as specified and directed. |
| 112 | Supply and fix switch modular type single pole, one way 16 Amp complete all as specified and directed. |
| 113 | Supply and fix socket out let 2 in1,3 pin, 6 and 16 Amp, modular type complete all as specified and directed. |
| 114 | S&F ceiling rose, PVC/ Poly carbonate,isolated body three terminal complete all as specified and directed. |
| 115 | S & F lamp holder angle type PVC/Poly carbonate type insulated body with back plate suitable for batten/wall fitting complete all as specified and directed. |
| 116 | Supply and fix High quality LED T8 indoor batten tube light 20 Watt with aluminium extrusion in D shaped have large diameter for increased convection heat transfer incl one LED PC tube rod and driver, internaly pre wired of 1.5 sqmm twin twisted flexible cable all as specified & directed.NOTE: The contractor must submit 5 years warranty for LED fitiings. |
| 117 | Supply & Fixing of MCB SP, 240 volts,AC C curve, 10 KA 6 to 32 Amps . |
| 118 | Supply & Fixing of MCB SPN , 240 volts,AC B curve, 10 KA 40 Amps. |
| 119 | Supply & Fixing of MCB DP , 240 volts,AC C curve, 10 KA 40 Amps. |
| 120 | Supply & Fixing of MCB TPN , 415 volts, AC C curve, 10 KA 100 Amps. |
| 121 | S&F sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts 20 Amps including one 15 Amp switch on existing board with wiring for switching geyser on/off complete all as specified and directed. |
| 122 | Supply & Fixing of non metallic PVC conduit 25 mm exclusive of boxes but including of all tees,bends,elbows, reducers,bell mouth tube ends and fixing accessories such as couplers,lock nuts,saddles, pipe hooks etc. concealed in wall ceiling floor etc for television/DTH/telephone/Data cable complete all as specified and directed. |
| 123 | S& F socket outlet for TV/Video/audio device modular type with inner and outer modular plate type, specially built for wall/high mounted TV and inc pressed steel/metal flush box concealed complete all as specified and directed. |
| 124 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete. all as specified and directed .NOTE : The contractor must submit 5 years warranty for LED fittings |
| 125 | Taking down carefully All types of DB's/ MCB DB's with MCB and making good the disturbed surfaces of walls as directed. |
| 126 | S&F sheet metal enclusure for DBs(double door type) single pole and neutral 8 way including blanking platge as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |
| 127 | S&F sheet metal enclusure for DBs(double door type) Triple pole and neutral 4 way including blacking platge as required with 200 Amps rated bus bar, 415 volts fixed complete all as specified and directed . |
| 128 | S & F LED bulk head fitting, 1 x 10 watt with PDC aluminium housing and milky diffuser including LED light driver holder, complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230 Volts, 50 Hz complete all as specified and directed. NOTE: The contractor must submit 5 years warranty for LED fittings |
| 129 | M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed.Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. |
| 130 | S& F LED Bulb of 9 watt as specified .NOTE: The contractor must submit 5 years warranty for LED fittings |
| 131 | Supply and fixing Geyser 25 Ltr Capacity, BEE five star rating with Digital Temperature Display & heating element upto 2 KW, ISI mark, with all accessories such as safety valve, thermostate, NRV, connection piece etc, and making good as per existing surface Complete all as specified and directed. |
| 132 | Taking down storage type water heater (geyser) of any type /make up to 50 Ltr capacity after disconnecting electric / water connections and refixing the same after carrying out necessary repairs including reconnecting the electric / water connections and testing complete all as specified and diected. |
| 133 | S & F Exhaust fan plastic body heavy duty ISI mark, 250 mm size with louvers including all connecting accessories and cutting opening on wall and making good as per existing surface complete all as specified and directed |
| 134 | S&F Exhaust fan metallic body ISI mark, 450 mm size with louvers including cutting openings, through brick/ stone wall , making of holes and grouting of suitable size of nuts and bolts for 300 mm exhaust fan and making good dismantled portion and making connection with wire of suitable size and connecting accesssories complete all as specified and directed. |
| 135 | Taking down carefully copper / aluminium sub main wiring including teak wood batten / conduit and making good the disturbed surface of walls as directed. |
| 136 | S&F sub main wiring with two single core FR-LSH PVC insulated and sheathed 1100 Volts grade, 6.0 Sqmm size cables, PVC insulated stranded copper conductor fixed in PVC conduite pipe 25mm dia with all accessories and one continuous run of 6.0 Sqmm copper conductor PVC complete all as specified and directed (Note :- Two single core cables along with earth wire and conduit shall be measured as one unit length). |
| 137 | Supply, laying and testing cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core. |
| 138 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of underground cable and getting out in any type of soil complete all as directed by the Engineer-in-Charge |
| 139 | Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cms. thick in soft / loose soil complete all as specified and directed by Engr -in -charge . |
| 140 | Removal of surplus soil not exceeding 50 Mtr and depositing where directs at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 141 | M&L for sand cushioning in trenches spreading and consolidation 8cm thick before laying the cable & 15 cm of sand after laying the cable complete all as specified |
| 142 | M&L for laying of bricks well burnt sub class ‘B’ (old pattern) laid flat for cable protection width equal to the lengrth of brick complete all as specified . Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail