Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-04-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-04-2026 |
| 2 | 20-03-2026 | CorrigendumNo1 | BOQ | 02-04-2026 |
| 3 | 20-03-2026 | CorrigendumNo1 | BOQ | 09-04-2026 |
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.complete all as directed. |
| 2 | M & L for screed bed or bedding layer 15mm thick in cement mortar(1:6) for laying floor finishes Complete all as specified and directed. |
| 3 | M & L for non skid ceramic coloured /printed tiles 7 to 8 mm thick (square / Rectangular)area of each tiles exceeding 0.18 sqm but not exc 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles. |
| 4 | M & L for non skid ceramic coloured /printed tiles 7 to 8 mm thick (square / Rectangular)area of each tiles exceeding 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles. |
| 5 | All as per item no 3 for dado /skirting Complete all as specified and directed. |
| 6 | M & L for glazed ceramic coloured / printed tiles 300mm x 450mm, 6 to 7mm thick, on vertical surfaces set and jointed in neat cement slurry and pointed in white/coloured cement to match the tiles, complete all as specified and as directed. |
| 7 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness.(below or above ground level) Complete all as specified and directed. |
| 8 | M & L for 75 mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in plinth protection finishing the surface even and smooth without using extra cement Complete all as specified and directed. |
| 9 | Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water etc.&removing rubbish to a disance not exc 250m Complete all as specified and directed. |
| 10 | M&L for rendering 15 mm thick readymade plaster on inner/outer walls by adding 17-19% of potable water by weight of material for thickness above 15mm it is recommended to be applied in multiple layers. ready mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the compressive strength @ 28 days 10-12 Mpa/Bulk density 1500-1600 Kg/m3. (Note : The rate quoted by contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20 Mtr ht all as specified and directed) |
| 11 | M/L for preparing newly plastered wall surfaces and applying two coat of distemper oil emulsion over 1mm thick wall care putty, complete all as specified . |
| 12 | M & L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90litre/10 sqmover new surfaces. |
| 13 | M/L for complete removal of existing treatment for preparing old painted surfacess and applying two coat of distemper oil emulsion over a coat of primer incl 3 mm thick applying a layer of JK/ Birla putty on wall surfaces including cornics etc for proper levelling of plaster complete all as specified and directed. |
| 14 | Material & Labour for complete removal of existing treatment and applying Two or more coats of 100% remium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including primingcoat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces |
| 15 | Demolition brick work or stone/ boulder masonery built in cement mortar including all quoins , pillars etc |
| 16 | M & L for Pre-cast cement concrete block masonry in PCC 1:3:6 type C-1(using 20mm graded stone aggregate) set in CM 1:4 with solid blocks, exc. 10 cm in width complete all as specified and directed. |
| 17 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.5 sqm each.& removing to or from store complete all as specifed & directed. |
| 18 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) but exc. 1.5 sqm n. exc.4sqm each & removing to or from store complete all as specified and directed. |
| 19 | M&L for Pressed steel frames 125X60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.,supplied and fixed complete all as specified and directed. |
| 20 | S&F 35mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed |
| 21 | S & F 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., rs, edges of framing plain, chamfered complete all as specified and directed. |
| 22 | S&F 18mm thick MDF Board both side finished as in wardrobe/ cup board shutter all as specified and as directed by Engineer-in-Charge. |
| 23 | S&F three track aluminum powder coated sliding window with three sliding shutter , the size of outer frame three track 100 x 37x 1.50mm ( using two track for glazed window shutter and one track for wire gauged ) , the section shutter size 37x 18x 1.2mm)and glazing with 5 mm thick Transparency glass of poly carbone including all-around suitable rubber gasket and stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4mm and fixed on aluminum flat and inserted in the frame of shutter with tracking arrangement each sliding window shall be provided with one number handle including locking arrangement & 2 numbers’s sliding rollers of nylon with including all necessary fittings |
| 24 | Supply only Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 25 | S & F 125 mm long Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed |
| 26 | S & F floor door stopper of chromium plated body with rubber shoe fixed in door, overall length of cover plate 140 mm all as specified and directed. |
| 27 | S & F butt hinges, medium weight, Miled steel and fixed, size of hinges 100mm complete all as specified and directed. |
| 28 | S & F 150 mm long Extruded brass handles,fabricated type polished complete all as specified and directed. |
| 29 | S & F 100 mm long Extruded brass handles,fabricated type polished complete all as specified and directed. |
| 30 | Supply and fix 300 mm long ABrass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and directed. |
| 31 | M & L for Old painted surface to steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described with one coats of synthetic enamel including preparation of surfaces complete all as specified and directed. |
| 32 | M & L for newly painting to steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified and directed. |
| 33 | Factory made single extruded WPC (wood polymer Composite) solid door/ window/ Ceosetory window & other Frames/ Chowkhat of size 45 x 70 mm comprising of PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wwod powder/ rick husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded stat headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N / mm 2 and resistance to spread of flame of Class A catogory with property of being termite/ borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast/lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). |
| 34 | Factory made single extruded WPC (wood polymer Composite) solid plain flush door shutter of 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrwal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N mm2 modulus of elasticity 850 N / mm2 and resistance to spread of flame of Class A catogary with property of being termite/ borer proof, water/ moisture proof and fire retardanat and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-In-Charge (Note:- stainless steel butt hinges and necessary SS screws shall be paid separately. |
| 35 | M & L for painting to new wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of pink primer including preparation of surfaces. |
| 36 | M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed. |
| 37 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store. |
| 38 | Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store. |
| 39 | S&F GI water tubing of 15mm dia ,medium grade conforming to IS-1239(Part -1) including all fittings such as bends,tees,short pieces,connectors,elbows,reducers,union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed. |
| 40 | S&F GI water tubing of 20 mm dia ,medium grade conforming to IS-1239(Part -1) including all fittings such as bends,tees,short pieces,connectors,elbows,reducers,union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed. |
| 41 | S&F in repairs stop valves/angle valves, cast copper alloy, fency type chromium plated , screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore dia of pipe. |
| 42 | S&F in repairs stop valves, cast copper alloy, fancy type chromium plated with long shank & cup (concealed) , screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore dia of pipe. |
| 43 | S & F in repairs 15 mm bore Fancy type chromium plated Wall Mixer with or without (as required at site) provision for overhead shower with 115mm long bend pipe on upper side, connecting legs and wall flanges, screwed down high pressure with or without lettered hot and cold screwed for iron pipe complete all as specified and directed .Make i ( Jaquar cat Part No:- FUS- 29281 ii ( Marc cat Part No :- MDM - 2350 or Cera Equivalent. |
| 44 | S & F vitreous china wash basin(pedastel type), white, flat back, size 620X480X185 mm, (flat back or angle back type) including brackets and including cutting for and pinning in ends of brackets or erecting stand, fixed in repairs.Make i ( Jaquar cat Part No:- FNS-WHT-40801 ii ( Cera cat Part No :- 1067 A or Hindware Equalant. |
| 45 | S & F in repairs 15 mm bore Fancy type pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed.Make i ( Jaquar cat Part No:- COP -001BPM ii ( Marc cat Part No :- MFX- 2010 or Cera Equalant. |
| 46 | S&F 32mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed. |
| 47 | S & F in repairs bib taps, cast copper alloy, 15 mm dia, Chromium Plated, fancy type with crutch or butterfly handle, screwed down for iron pipe and fixed etc complete all as specified.Make i ( Jaquar cat Part No:- KUP- 35037 PM ii ( Marc cat Part No :- MFX - 2170 or Cera Equalant. |
| 48 | M & L for 32mm bore high density polyethylene pipes (HDPE) complete all as specified and directed. |
| 49 | S&F brass chromium plated tubular towel rail, 20 mm dia, D; type, 60 cm long between flanges complete all as specified and directed.Make i ( Jaquar cat Part No:- ACN 11815 ii ( Marc or Cera Equalant. |
| 50 | S&F chromium plated Soap disk fixed to plug with chormium plated brass screws all as specified and directed.Make i ( Jaquar cat Part No:- ACN-1131N ii ( Marc or Cera Equalant. |
| 51 | S&F in repairs Chromium plated shower rose 125 mm swivel typeMake i ( Jaquar cat Part No:- OHS-35495 ii ( Marc cat Part No :- MSR - 1170N or Cera Equalant. |
| 52 | S & F 20mm Dia Aluminium alloy anodised curtain rod decorative fency type with brackets complete all as specified. |
| 53 | S & F PVC connections 15mm dia , 450mm long, , with PTMT nuts & washers at both ends |
| 54 | Dismantling water tanks of any description, capacity exceeding 500 litres but not exceeding1000 liters complete. |
| 55 | S&F rotational moulded polythene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in postion 1000 ltrs capacity and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram of Make - Prayag complete all as specified and directed. |
| 56 | S&F One piece Vitreous china wash down water closet (Pedestal Pattern) Size 655X355X730MM \\"snow white\\" with duroplast slim soft close seat cover & twin flush fittings, toilet paper holder, health fuaucet, PVC connection, angular stop cock (valve) (2 Nos) with flange etc all as specified in particular specifications. Note: Vitreous china wash down water closet (Pedestal pattern) cat Part No S1013208 trap 100mm of Cera or equivalent model of make specified. |
| 57 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified |
| 58 | S&F in repairs Gun-metal, globe or gate valves 15 mm, with iron wheel head, screwed both ends for iron pipe and fixed |
| 59 | S&F in repairs Gun-metal, globe or gate valves 20 mm, with iron wheel head, screwed both ends for iron pipe and fixed |
| 60 | S&F mirror cabinet 400mm x500mm hanging system and clamps support and holes with screws and back support rectangular fixed to plug with screws and cup washers complete all as apecified & directed |
| 61 | S&F in repair for PVC (SWR) floor trap 75 mm, plain with grating including jointing with solvent cement complete all as specified and directed |
| 62 | S & F in repair PVC (SWR) 75 mm pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 63 | S & F in repair 75 bore PVC (SWR) bends any radius complete all as specified and directed. |
| 64 | S & F in repair PVC (SWR) vent cowls 75mm dia complete all as specified and directed.. |
| 65 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. |
| 66 | S & F MS framed work such as grills, gratings, etc., with end of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 190-0 or Fe-165-0. |
| 67 | Dismantling timber scantlings 40 sq. cm unframed work and over in section, in any position |
| 68 | Dismantling boarding, any description, fixed in any position with nails |
| 69 | M & L for second class wrought hard-wood timber fixed in scantlings complete all as specified and directed |
| 70 | M & L for 25mm thick second class hardwood, width n exc.20cm complete all as specified and directed |
| 71 | S&F in repairs parquet flooring 8.3 mm thick hard board plank both side laminated with decorative surface and approved by GE laid above the thermoplastic sheet complete all as spd |
| 72 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc,) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed. |
| 73 | S & F for Aluminium anodised snap grid frame work for false ceiling comprising of following section for making partitions of 605 X 605 mm size fixed to walls with rawl plugs and screws and hang to roof with s 6 mm dia. G.I. (upto1200mm length) adjusting levelfixed to roof slabs by means ofceilling cleats made out of G.I.flat 40 x 3 mm size 60mm longand expansion hold fasteners12.5mm dia. 40mm long complete all as specified. size of main tee shall be :-(i)36.5mmx25mmx1.4mm thick, Weighing 0.24Kg/Rm(ii)Cross Tee 23.5mmx36.4mmx1.4mm thick Weighing 0.191 Kg/Rm and (iii)Wall angle 40mmx25mmx2mm thick. Weighing 0.36 Kg/Rm |
| 74 | S & F 4 mm thick non asbestos fiber disigner ceiling (E-board classic) board / tiles for insulation and accoustic purpose, 600 X 600 mm size fixed with staples on snap grid as in ceiling with and including dusting of surface and applying two coats of oil bond distemper over a coat of primer complete all as specified and directed |
| 75 | Dismantaling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 76 | S&F Pre-painted galvaLume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering / clading to waall , fixed self tapping screws complete all as specified and directed. |
| 77 | S&F Pre-painted galvatume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering / clading to waall ,valle gutters, drip, fixed self tapping screws complete all as specified and directed. |
| 78 | M & L for Cement concrete Type C2 1:3:6 (40mm garded aggregate) in foundations, filling and mass concrete |
| 79 | M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in CM (1:6) complete al as specified |
| 80 | M/LCement concrete 1:3:6 type C-1 using 20mm graded stone aggregate in surface channels and drains complete. |
| 81 | M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed |
| 82 | M/L Cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate in cills, seismic and other similar bands, plinth courses, copings, bed plates, bond stones, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete. |
| 83 | Extra for forming fair finished drain or channel 30 cm inner girth in cement complete all as specified and directed. concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc.All as specified and directed. |
| 84 | M & L for providing plain cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in coping, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 85 | M & L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 86 | M & L for Precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cover slabs (for manholes etc), shelves and similar articles with plain faces including necessary moulds and setting inCm 1:6 including necessary formwork complete all as specified and directed( reinforcement to be measured seperately) |
| 87 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in Hard/ Dense soil complete all as specified and directed. |
| 88 | Demolation and breaking up drain pipes 150 mm (salts glazed ware ,AC or Reinforced concrete) set in cement mortar all as specified |
| 89 | M & L 150 mm dia Salt Glazed stone ware drain pipes laid in trenches and jointed as specified complete all as specified and directed. |
| 90 | M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150mm bore complete all as specified and directed. |
| 91 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed. |
| 92 | Removing Excavated soil exceeding 250 M but not exceeding 1.50KM and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed. |
| 93 | Construction of brick masonary septic tank 25 users capacity with excavation and earth work in hard/dense soil or in soft/ distegrated rocks, PCC 1:2:4 type B-2 as in foundation, brick work in CM 1:4, RCC M-25, CI manhole cover (HD), vent, shaft and sludge chamber etc complete all as specified and directed |
| 94 | Construction of Brick masonary Soakage well of 3.60 m internal dia and 3.0 m effective depth and excavation & earth work in hard/dense soil or soft disintegrated rock in PCC 1:3:6 type C-2 as in foundation, honey combed and solid brick work in CM 1:4, RCC M-25 cover slab, PCC 1:2:4 in bands, filling with brick bats complete all as specified and directed |
| 95 | M&L 75 mm thick cement concrete 1:4:8 type D-2 finished fair and even as in sub base Complete all as specified and directed. |
| 96 | M&L for chequred cement concrete tiles of size 300x300x25 mm thick coloured rubber pressed glossy finish, set and jointed in neat cement slurry and pointed in white or colour cement and match the surace of tiles as foor/staps, complete as all specified and directed. |
| 97 | Taking down carefully Aluminium/copper wiring of any size (for light, fan, socket or power etc complete) ( fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc to be measured and paid separately) and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed. |
| 98 | M & L point wiring for Modular fittings for one light point/ fan/ bell/ 5Amps socket out let (independent)point controlled by one, one way switch with 1.5 sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FR-LSH) PVC cable drawn into & including medium grade PVC conduit (not less than 20mm outer dia )with all fittings and accessories fixed concealed (including chase cutting in brick/ stone masonry walls for fixing conduit and plastering and whitewash/colouring the external surface and matching the same with existing surface) incl modular metal flush box for mounting modular fittings and covered with modular cover plate with frame and cup washers including one continuous run of PVC insulated (green colour) 1.5 Sqmm multistranded copper conductor cable earth wire and connected to earth dolly complete all as specified and directed One light/One fan/one bell point controlled by one modular switch |
| 99 | One modular socket outlet 3 pin 6 amps controlled by one switch on same board. |
| 100 | One modular socket outlet 3 pin 6 amps controlled by one switch on independent board. |
| 101 | All as per item No 2 herein before but wiring with 2.5 sqmm copper wire (FRLS) PVC and 2.5 sqmm earth wire for modular socket outlet 5 pin 16 amps on independent board. |
| 102 | Supply and fix in replacement modular type switch single pole, one way 6 Amp complete all as specified and directed. |
| 103 | Supply and fix in replscement socket out let multi 5 pin, 6 Amps, modular type complete all as specified and directed. |
| 104 | Supply and fix switch modular type single pole, one way 16 Amp complete all as specified and directed. |
| 105 | Supply and fix in replacement socket out let 2 in1,3 pin, 6 and 16 Amp, modular type complete all as specified and directed. |
| 106 | S&F in replacement ceiling rose, PVC/ Poly carbonate,isolated body three terminal complete all as specified and directed. |
| 107 | S & F in replacement lamp holder angle type PVC/Poly carbonate type insulated body with back plate suitable for batten/wall fitting complete all as specified and directed. |
| 108 | Supply and fix in replacement High quality LED T8 indoor batten tube light 20 Watt with aluminium extrusion in D shaped have large diameter for increased convection heat transfer incl one LED PC tube rod and driver, internaly pre wired of 1.5 sqmm twin twisted flexible cable all as specified & directed.NOTE: The contractor must submit 5 years warranty for LED fitiings. |
| 109 | S & F in replacement Recess mounting LED luminaire 600mm x 600 mm ,36 W, 220v, with high efficiency PMMA diffuser soft glare free light suitable for recessed mounting ,with powder coated CRCA housing with LEDs, seamless front frame complete with driver and all accessories internally pre-wired and including necessary cutting as required in panel and connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.Note: The contractor must submit 5 years warranty for LED fitiings. |
| 110 | Taking down unservicable MCB and S&F MCB SP, 240 volts,AC C curve, 10 KA 6 to 32 Amps . |
| 111 | Taking down unservicable MCB and S&F MCB SPN , 240 volts,AC B curve, 10 KA 40 Amps. |
| 112 | Taking down unservicable MCB and S&F MCB DP , 240 volts,AC C curve, 10 KA 40 Amps. |
| 113 | Taking down unserviceable MCB S & F MCB TPN , 415 volts, AC C curve, 10 KA 100 Amps. |
| 114 | S&F in replacement sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts 20 Amps including one 15 Amp switch on existing board with wiring for switching geyser on/off complete all as specified and directed. |
| 115 | Supply & Fix in replacement of non metallic PVC conduit 25 mm exclusive of boxes but includinf of all tees,bends,elbows, reducers,bell mouth tube ends and fixing accessories such as couplers,lock nuts,saddles, pipe hooks etc. concealed in wall ceiling floor etc for television/DTH/telephone/Data cable complete all as specified and directed. |
| 116 | S& F in replacement socket outlet for TV/Video/audio device modular type with inner and outer modular plate type, specially built for wall/high mounted TV and inc pressed steel/metal flush box concealed complete all as specified and directed. |
| 117 | Supply and fix in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete. all as specified and directed .NOTE : The contractor must submit 5 years warranty for LED fittings |
| 118 | Taking down unservicable DB and S&F sheet metal enclusure for DBs(double door type) single pole and neutral 4 way including blanking platge as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |
| 119 | Taking down unservicable DB and S&F sheet metal enclusure for DBs(double door type) single pole and neutral 8 way including blanking platge as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |
| 120 | S&F in replacement sheet metal enclusure for DBs(double door type) Triple pole and neutral 4 way including blacking platge as required with 200 Amps rated bus bar, 415 volts fixed complete all as specified and directed . |
| 121 | S & F in replacement LED bulk head fitting, 1 x 10 watt with PDC aluminium housing and milky diffuser including LED light driver holder, complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230 Volts, 50 Hz complete all as specified and directed. NOTE: The contractor must submit 5 years warranty for LED fittings |
| 122 | Taking out old U/S Sub main wiring for replacement including S&F sub main wiring with two single core (FR-LSH) PVC insulated and sheathed 1100 Volts grade, 10.0 Sqmm size cables, PVC insulated stranded copper conductor fixed in PVC conduite pipe 25mm dia with all accessories and one continuous run of 10.0 Sqmm copper conductor PVC complete all as specified and directed (Note :- Two single core cables along with earth wire and conduit shall be measured as one unit length). |
| 123 | M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed.Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. |
| 124 | S & F in replacement call bell ding dong AC, 230V single pole fixed over with and including sunk spressed steel box of size 175mmx100mm with 3mm thick plastic laminated backalite shut cover fixed with brass screw complete all as specified and directed, |
| 125 | S&F in replacement modular bell push, 6 Amp 1 module complete all as specified and directed. |
| 126 | S& F LED Bulb of 9 watt as specified .NOTE: The contractor must submit 5 years warranty for LED fittings |
| 127 | Supply and fix in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with two core flexible copper conductor cable of suitable size complete all as specified and directed. NOTE: The contractor must submit 5 years warranty for LED fittings |
| 128 | Supply and fix in replacement Geyser 25 Ltr Capacity, BEE five star rating with Digital Temperature Display & heating element upto 2 KW, ISI mark, with all accessories such as safety valve, thermostate, NRV, connection piece etc, and making good as per existing surface Complete all as specified and directed. |
| 129 | S&F in replacement Exhaust fan metallic bady ISI mark, 300 mm size with louvers including cutting openings, through brick/ stone wall , making of holes and grouting of suitable size of nuts and bolts for 300 mm exhaust fan and making good dismantled portion and making connection with wire of suitable size and connecting accesssories complete all as specified and directed. |
| 130 | Supply, laying and testing in replacement cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 2 core complete all as specified and directed. |
| 131 | Supply, laying and testing in replacement cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core.complete all as specified and directed. |
| 132 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of underground cable and getting out in any type of soil complete all as directed by the Engineer-in-Charge |
| 133 | Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cms. thick in soft / loose soil complete all as specified and directed by Engr -in -charge . |
| 134 | Removal of surplus soil not exceeding 50 Mtr and depositing where directs at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 135 | M&L for sand cushioning in trenches spreading and consolidation 8cm thick before laying the cable & 15 cm of sand after laying the cable complete all as specified and directed. |
| 136 | M&L for laying of bricks well burnt sub class ‘B’ (old pattern) laid flat for cable protection width equal to the lengrth of brick complete all as specified and directed. |
| 137 | M & L galvanised steel water tubing 'light grade' 25 mm bore with all fittings laid under the roads, drains, culverts and fixed on poles etc complete all as specified and directed . Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy