| 1 | Dismantling of wall and ceiling boards(fibre, pulp, insulationetc.) or insulation boards/ slabs/ blankets, any thickness including cover fillets complete all as specified. |
| 2 | S&F hangers 6mm dia G.I. (upto 1200mm length ) adjusting level, size of grid 605mm X605mm, fixed to steel purlins or rafter with nexc 60cm long and 6mm dia adjustable GI fasterners Complete all as specified and as directed by Engr-in-charge. |
| 3 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mmthick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. size of grid 605mm X605mm complete all as specified and directed. |
| 4 | S&F 6 mm thick non asbestos fiber cement building board (Designer ceiling board) , fixed to aluminium or MS galvanised snap grid frame work with screw in ceiling complete all as specified. |
| 5 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings complete all as specified and directed. |
| 6 | M & L for 0.63 mm galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts in lieu of screws etc Complete all as specified and as directed by Engr-in-charge. |
| 7 | M & L for 0.63 mm galvanised, Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 Complete all as specified and as directed by Engr-in-charge. |
| 8 | Taking down Chowkats or frames not exceeding 1.5 Sq. M each (Without taking off shutters from the frames) complete all as specified and directed. |
| 9 | Taking down chowkats or frames exc 1.5 sqm but not exceeding 4 sqm each but with shutter (without taking off shutter from the frame) and removing to store complete all as specified and directed by Engr-in-charge. |
| 10 | Taking down shutters of any description area exc 1 sqm and n exc 2 sqm each complete all as specified & directed. |
| 11 | Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) complete all as specified and directed. |
| 12 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc complete all as specified and directed. |
| 13 | M & L Precast cement concrete 1:3:6 type C1 (Using 20 mm graded stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed. |
| 14 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified. |
| 15 | Supply and fix steel work in tubular trusses including crane gantries, rails and fastenings and heavy brackets framing (beam, tee, angle, channel or flat sections) of Fe 410-W (Gde-E-250) quality A, including distance places, cleats etc complete all as specified and as directed. |
| 16 | S& F for Plates (plain or chequered) Fe 410-W (GdeE- 250) qualityA channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and directed. |
| 17 | M&L for Mild steel screw bolts 15mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5cm and n exc 30cm long long complete all as specified and directed. |
| 18 | Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 meter in depth and getting out in soft/disintegrated soil complete all as specified and directed. |
| 19 | M & L for PCC (1:4:8) type D-2 using40mm graded stone aggregate in foundation/filling and mass concrete complete all as specified and directed. |
| 20 | Material and Labour PCC 1:3:6 Type C1(using 20 mm graded stone aggregate) as in bed block , etc including necessary form work complete all as specified and as directed . |
| 21 | M&L For Reinforced cement concrete Nominal Mix 1:1.5:3 Type A 1(using 20 mm graded stone aggregates) in foundations, footing, plinth beams, bases for columns and mass concrete (reinforcement to be measured separately) complete all as specified & directed. |
| 22 | M&L For Reinforced cement concrete Nominal Mix 1:1.5:3 Type A 1(using 20 mm graded stone aggregates) in Columns, pillars, piers, posts and struts complete all as specified & directed. |
| 23 | M&L For RCC 1:2:4 type B-1, ( using 20 mm graded stone aggregate ) as in beams, cantilevers, bed block, bressummers, lintels over 1.5m span , including necessary form work etc Complete al as specified and as directed. |
| 24 | M & L for Reinforced Cement Concrete Nominal Mix 1:1.5:3 Type A 1(using 20 mm graded stone aggregate) in Chajjas and the like complete all as specified & directed. |
| 25 | M & L Use and waste of Form work to sides of concrete foundations, footings, bases of columns, sides & soffits of foundation and plinth beams and similar work for rough finished flat surfaces of concrete complete all as specified & directed. |
| 26 | M & L Use and waste formwork to sides of pillars,posts,struts,piers, columns and stanchions, complete all as specified & directed. |
| 27 | M & L for use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, bands, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished flat surface of concrete complete all as specified and directed. |
| 28 | M & L Use and waste formwork to chajjas, through and similar items including edges, all as specified and directed. |
| 29 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 30 | M & L for mild steel TMT bars 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 31 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finish the surface even and smooth without using extra cement all as specified & directed . |
| 32 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement. |
| 33 | M&L preparing newly plastered surfaces of wall and applying complete wall with 1.5 mm Wall putty and making smooth surfaces and applying two coats of Oil bound distemper over a coat of primer all as specified and directed by Engineer-in-Charge. |
| 34 | M & L preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls over one coat of white wash complete all as specified and directed by engr in charge. |
| 35 | M&L for 75 mm thick PCC 1:3:6 type C2 in plinth protection finishing even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 36 | M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing & finished the surface even & fair all as specified. |
| 37 | M & L for PCC 1:2:4 type B-1, 25 mm thick, using 20mm graded stone aggregate as in surface of flooring finishing surface even and smooth without using extra cement all as specified and directed. |
| 38 | M & L for 15mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed. |
| 39 | S&F Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match shade of the tiles complete all as specified & directed.Notes : Shade of the tile including colour, design and pattern shall be approved by AGE. |
| 40 | S&F Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in Skirting etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match shade of the tiles complete all as specified & directed.Notes : Shade of the tile including colour, design and pattern shall be approved by AGE. |
| 41 | M&L for glazed ceramic coloured tiles in verticle surface 350mmx450mmx7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat 10mm thick cement mortar in 1:4 complete all as specified and directed. Notes : Shade of the tile including colour, design and pattern shall be approved by AGE. |
| 42 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 43 | M&L for Chequered cement concrete tiles 25mm thick with grey cement and pigment set and jointed in neat cement slurry and pointed in white or coloured cement incl 15mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and directed by Engr-in-charge. |
| 44 | S&F pressed steel frames 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.,complete all as specified and directed by engr in charge. |
| 45 | M&L Plain Cement Concrete 1:3:6 type C1 filling of pressed steel frame and hold fast block etc. complete all as specified and directed by engr in charge. |
| 46 | S&F 2nd class hardwood factory made 30 mm thick flush shutter solid core construction with block board core & plywood face panels commercial type on both sides incl 5mm thick teakwood leaping alround complete all as specified & directed. |
| 47 | M & L for Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer.complete all as specified & directed |
| 48 | S & F Mild steel butt hinges medium weight , cold rolled, 100mm, ISI marked, complete all as specified and as directed by Engr-in-charge. |
| 49 | M&L Aluminium anodised, barrel tower bolts of extruded section and fixed of size 200 mm complete all as specified and as directed by Engr-in-charge. |
| 50 | S&F 150 mm long aluminium anodised handles or extruded section complete all as specified . |
| 51 | S&F 300mm long Aluninium alloy, anodised , sliding door bolt with hasp , staple,(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 52 | S&F floor door stopper 140 mm of aluminium alloy body and tongue anodised with hard drawn steel spring complete all as directed by Engineer-in-charge. |
| 53 | S&F in Powder coated aluminium sliding window with shutter styles 40mm x20 mm sheet thickness 1.2mm two shutter of glass and one shutter of wire mesh consisiting of Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, frame (chowkat) of window shall 91.80mmx31.75mmx1.2mm thick section (three track) with or without rebate. 4mm thick tinted glass fixed with aluminium beads locking arrangement with each shutter all as directed by the Engineer-in-Charge Note: Size of window shall be as per site requirement. |
| 54 | S&F in repair 20mm dia curtain rods fancy type, mild steel chromium plated with fixing brackets, stops, rollers complete all as specified and as directed by Engr-in-charge. |
| 55 | S & F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars,stiffeners, gusset plates, etc.Fe-410-W(gde-E-250) quality A complete all as specified and directed. |
| 56 | Dismantling PVC water tanks and removing from site capacity for exc 500 ltrs but n. exc 1000 ltrs complete all as specified and as directed. |
| 57 | S&F For 1000 ltr. Capacity rotational moulded polyethylene water storage tanks cylindrical vertical with closed top) hoisted and fixed in position including all fittings complete all as specified in SSR Part I complete all as specified and directed. |
| 58 | M&L 20mm bore dia ball brass valves, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 59 | S&F 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by engr in charge. |
| 60 | M & L preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 61 | S&F For Steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel,complete all as specified and directed by engr in charge. |
| 62 | S&F For 4mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed by engr in charge. |
| 63 | Taking up or down 15mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed by engr in charge. |
| 64 | Taking up or down 20m bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed by engr in charge. |
| 65 | M & L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water complete all as specified and directed by Engr in charge. |
| 66 | S&F 15mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors complete all as specified and directed by engr in charge. |
| 67 | S&F 20mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors complete all as specified and directed by engr in charge. |
| 68 | S&F in repair vitreous china wash basin , white , flat back, size 550 x 400 mm excluding taps, waste chain and plug and porcelain stopper but including brackets , waste coupling complete all as specified and directed by engr in charge. |
| 69 | Supply and fix in repairs white vitreous china squatting pan ‘ORISSA’ pattern of size 580 mm x 450 mm white with foot rests with ‘P’ or ‘S’ trap, front or back inlet including all connection and provision of lime concrete base complete all as specified and as directed.. |
| 70 | S&F in repair 10 ltr capacity PVC valveless , syphonic action type flushing cistern, low level, white, with inlet ball valve, float and handle including brackeet and 32mm dia flush pipe of polyethylene of low or high density for low level cistern complete all as specified and directed.Make-Cera |
| 71 | S&F for waste coupling of PTMT for 32 mm bore dia of discharge pipe (half or full threaded) complete all as specified and directed. |
| 72 | S&F PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed by engr in charge. |
| 73 | S&F in repair 15mm fancy type bib tap, chromium plated with crutch or butterfly handle, screwed down , screwed for iron pipe or for brass ferrule complete all as specified and directed . |
| 74 | S&Fin repairs pillar taps cast copper alloy capstan heads, chromium plated, screwed down high pressure with or without lettered hot or Cold with long screwed shank and fly nuts screwed for iron pipe and fixed bore of pipe 15mm complete all as specified and direrected. |
| 75 | S&F in repair 15mm dia stop valve / Angle valve chromium plated fancy type screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe or for union complete all as specified and directed by engr in charge. |
| 76 | S&F 75mm PVC(SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed by engr in charge. |
| 77 | S&F 75mm PVC(SWR) bend any radius complete all as specified and directed by engr in charge. |
| 78 | M&L 75mm PVC(SWR) floor trap with grating including jointing with solvent cement complete all as specified and directed by engr in charge. |
| 79 | S & F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long all as specified and directed. |
| 80 | S&F in repair aluminium anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 81 | S & F for 600mm x 450mm bevelled edge mirror or selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chroimium plated brass screws and cup washers complete all as specified and directed. |
| 82 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by engr in charge. |
| 83 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by engr in charge. |
| 84 | M & L for old decorative surfaces, preparation of wall and applying two coats of cement base paint complete all as specified and as directed . |
| 85 | M&L for prepair old decorative surface and applying two coats of oil bound distemper on walls etc complete all as specified and as directed . |
| 86 | Taking down carefully copper/aluminium point wiring from existing points (light, fan, socket or power) alongwith compete fittings such as switches ,ceiling rose, pendent holder, sketch fitting & regulator etc. including making good to the disturbed surfaces of wall, roof and floor etc. to match with the existing surfaces complete all as specified and directed by Engineer-in-Charge. |
| 87 | M&L for point wiring complete with 1.5 sqmm single core PVC insulated FRLSH cable 1100 volts grade with multi stranded copper conductor drawn through and including non metallic rigid PVC casing capping medium grade ISI Marked and all casing capping accessories fixed on wall/fixed to roof/truss/colums etc and including provision of 1.5 sqmm PVC insulated copper acble FRLSH as earth continuty conductor, febricated branded modular metal flush box duly make embossed, conncealed in walls with suitable modular inner and outer plate for housing modular switches, socket outlet and fan regulator etc. all as specified for one light point/ fan /Bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge. |
| 88 | All as per Srl item No 87 here-in-before but controlled with one 5 pin socket outlet 5 Amp on same board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 89 | All as per Srl item No 87 here-in-before but controlled with one 5 pin socket outlet 5 Amp, independent board with cable 1.5 sqmm including provision of 1.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 90 | All as per Srl item No 87 here-in-before but controlled with one 5 pin socket outlet 15 Amp, independent board with cable 2.5 sqmm including provision of 2.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 91 | Supply and fix in replacement of switch modular type 15 Amp, 230 Volt, single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 92 | Supply and fix in replacement of socket modular type outlet 5 pin 15 Amp 2-in-one 230 Volt complete all as specified and directed by Engineer -in-Charge. |
| 93 | Supply and fix in replacement of socket modular type outlet 5 pin 5 Amp 2-in-one 230 Volt complete all as specified and directed by Engineer -in-Charge. |
| 94 | Supply and fix in replacement of switch modular type type 5 Amp, 230 Volt, single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 95 | Supply and fix in replacement of Ceiling rose, 3 terminal with ISI mark all as specified and directed by Engr-In-Charge. |
| 96 | Supply and fix in replacement of surface & wall mounted LED 20W tube light fitting 4 feet with high quality material and design, extruded aluminium housing enhances safety. High quality PC diffuser, reliable and robust housing structure, maximize the endurance over the life time slim integrated design, easy to install efficacy 125 limen/ watt all accessories as specified and directed by Engg-in-Charge. |
| 97 | Supply and fix in replacement of lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings. |
| 98 | Supply and fix in replacement of LED lamp 12W energy saving upto 80%, BEE rated with all accessories all as specified and directed by Engg-in-Charge. |
| 99 | Supply and fix in replacement of stepped type electronic fan regulator modular type 120W 2module type on the existing phenolic laminated sheet etc.all as specified and directed by Engg-in-Charge. |
| 100 | Supply and fix in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 101 | Supply and fix in replacement of bulk head light with 10 W LED Lamp complete. |
| 102 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 AC decorativ type with driver jolder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete |
| 103 | Supply and fix in replacement of sheet metal enclosure double door for DBs single pole and neutral for 12 way 240 volt complete all as specified and directed by Engineer-in-Charge. |
| 104 | Supply and fix in replacement of MCB SPN 40 Amp,10 KA all as specified and directed by Engineer-in-Charge |
| 105 | Supply and fix in replacement of MCB SP 6 to 32 Amp, 10 KA. all as specified and directed by Engineer-in-Charge. |
| 106 | Supplying and fixing 1100 volts grade heavy duty, XLPE aluminium cable, in service connections,twin core 10 Sqmm Circural cabel, complete all as per specified and directed by Engineer-in-Charge. |
| 107 | M & L for sand filling floors or in foundation incl watering and compansation |
| 108 | M & L for old size bricks common burnt clay building bricks sub class B designation 75 |
| 109 | M&L for taking out old unserviceable and supply, laying, fixing Double walled corrugated HDPE duct pipe of 25 mm outer dia confirming to IS-14930 (Part-II) of approved colour with fittings for cable protection complete all as directed. |
| 110 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the ground level with top edge of the plate not less than 1.5 mtr below the normal ground level connected to the galvanised earth wire 4 mm dia by means of bolts, nuts hook nuts and washers of galvanization of steel all as shown in electrical plate no 3 connected to earthing testing point all as specified or indicated including testing on completions. |
| 111 | Supply and fixing building LED street light fitting 35w 230 volt AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver lamp bracket with impact and corrosion resistant incl thermal management in multiple optics complete with IP 65/66 Protection complete, all as specified and directed |
| 112 | Supply & fix exhaust fan made of sturdy engineering plastic complete with louvers shuttter AC, Single Phase 230/240V 300mm sweep 1200 RPM, with louvre complete all as per specified and directed by Engineer-in-Charge Note: Fixing of Exhaust Fan on wall with suitable size anchor bolt , making hole in wall for groutng and making good the disturbed surface including plaster work shall be part of job at no extra cost. |
| 113 | Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, min delivery 210CFM with service value five stat rated with brushless direct current motor (BLDC) complete all as specified and directed |
| 114 | Supply and fix electric Water heater storage type tank and heating element upto 2 KW capacity 25 litres.BEE 5 star rated complete with all accessories such as safety valve, thermosate NRV connection pieces etc. Note: Fixing of geyser on wall with suitable size anchor bolt with hammer drill and making good the disturbed surface including plaster work shall be part of job at no extra cost. |
| 115 | S & F for fixing of GI Pipe bracket of 40mm dia size of 1.2 mtr long bent to shape for fixing of LED Street light fittings and fixing to pole, walls etc including fixing of clamp, nut bolt etc as specified and directed |
| 116 | Schedule of Credit Please Enable Macros to View BoQ information |