Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Providing Submain Works |
| 2 | OD39599/2025-2026:DESIGN, SUPPLY, INSTALLATION, TESTING, AND COMMISSIONING OFSUB-MAIN MICRO-IRRIGATION SYSTEM AS PER THE IS SPECIFICATIONSAND APPROVED DESIGN FROM KIIDC DESIGN WING INCLUDING ALLSUBMAIN PVC PIPELINES-IND, PLACING EMITTER TAKE-OFF ANDFITTINGS, ACCESSORIES, FLUSH VALVES, IRRIGATION CONTROLVALVES, AND FITTINGS AND ACCESSORIES, SUPPLY OF SPARE PARTS,TOOLS ETC WITH ALL COST OF MATERIALS, LABOUR CHARGES, COST OFFITTINGS, CONVEYANCE INCLUDING ALL COST OF TRENCHING,BACKFILLING, AND LAYING AS PER DESIGN ALIGNMENT AND LEVELS,IF ANY, ETC, INCLUDING MATERIAL TEST REPORT FROM THE THIRDPARTYQUALITY CONTROL UNIT, AS PER THE SPECIFICATIONS ANDDIRECTIONS OF DEPARTMENTAL OFFICERS AT SITE. |
| 3 | Providing Mainline works |
| 4 | OD39589/2025-2026:DESIGN, SUPPLY, AND INSTALLATION, TESTING AND COMMISIONING OF MAINLINE MICRO-IRRIGATION SYSTEM AS PER THE IS SPECIFICATIONS AND APPROVED DESIGN FROM KIIDC INCLUDING MAIN LINE PVC FERTIGATION UNIT(UV PROTECTED), IRRIGATION CONTROL VALVES & PRV FOR MAINLINE, FITTINGS AND ACCESSORIES, SUPPLY OF SPARE PARTS, TOOLS,PRESSURE TESTING OF LAID PIPE LINES ETC WITH ALL COSTS OF MATERIALS, LABOUR CHARGES, COST OF FITTINGS, CONVEYANCE INCLUDING ALL COSTS OF TRENCHING, BACKFILLING, AND LAYING AS PER DESIGN ALIGNMENT AND LEVELS IF ANY, ETC INCLUDING, MATERIAL TEST REPORT FROM THE THIRD PARTY CONTROL UNIT, AS PER THE SPECIFICATIONS AND DIRECTIONS OF DEPARTMENTAL OFFICERS AT THE SITE. |
| 5 | Providing Automation works |
| 6 | OD39583/2025-2026:SURVEY, DESIGN, INSTALLATION AND TESTING OF FULLY AUTOMATED COMMUNITY MICRO IRRIGATION SYSTEM WITH ELECTRONICALLY CONTROLLED VALVES IN THE PROJECT AREA INCLUDING CONDUCTING CONTOUR SURVEY, INDIVIDUAL FARM BOUNDARY SURVEY, PREPARATION OF DESIGN AND DRAWINGS, PREPARATION OF OPERATION MANUAL,SUBMISSION OF MATERIAL APPROVAL REQUEST, SUBMISSION OF WORK SCHEDULE, FORMATION OF WATER USERS ASSOCIATION, TRAINING TO THE FARMERS, SUITABLE PUMPS &BOOSTER PUMPS WITH STANDBY AND ACCESSORIES FOR SUCTION AND DISCHARGE, CONSTRUCTION OF SUMP TANK OF SUITABLE SIZE AND INCLUDING COST OF RELATED ALL ACCESSORIES SUCH AS PRIMARY FILTRATION, SECONDARY FILTRATION,(SUITABLE AVAILABLE WATER SOURCE CAN BE UTILIZED, THE FILTERS SHALL BE SUITABLE FOR GROUNDWATER OR SURFACE WATER ACCORDING TO THE SITE CONDITION), FEEDERMAIN FROM FILTERS, SOLENOID VALVES, PRESSURE RELEASE VALVES, PRESSURE GAUGES, SAFETY ACCESSORIES, DRIP LOOP SYSTEM WITH PC EMITTERS OF MAXIMUM 3 LPH DISCHARGE HAVING EMITTER TO EMITTER SPACING OF MINIMUM 0.5 M (IN LINE LATERALS SHOULD BE HIGH UV RESISTANT,WITH ANTI SIPHON MECHANISM, PRESSURE-COMPENSATED RANGE: 0.4 BAR – 3.5 BAR, WIDE FILTRATION AREA OF DRIPPER IN BETWEEN 30 MM2 TO 39MM2, SELF-FLUSHING AND CONTINUOUS SELF-CLEANING MECHANISM, IDEAL FOR PERMANENT CROPS IN COMPLEX TOPOGRAPHY AND SUB SURFACE APPLICATIONS, RESISTANT TO STANDARD NUTRIENTS USED IN AGRICULTURE AND MEETS ISO 9261 STANDARDS), PRESSURE REGULATOR, DRIP MANIFOLD ACCESSORIES,QUICK RELIEF VALVE,PRESSURE REGULATORS,NRV, MCU SYSTEM WITH ALL OTHER ACCESSORIES(MCU SHOULD BE SCADA SCREEN WITH REAL TIME STATUS OF OUTPUTS AND SENSORS READING, COLOR DISPLAY, TOUCH SCREEN WITH RESOLUTION - 1280 * 800, CAPABLE OF WIRELESS OPERATION, INBUILT GLOBAL SIM, OPTION OF INTERNET CONNECTION VIA LOCAL SIM & LAN, MULTIPLE USERS ACCESS WITH HIERARCHY BASED ON DIFFERENT ROLES, DOWNLOADABLE USER REPORTS - IRRIGATION AND FERTIGATION REPORTS WITH CUSTOM TIME PERIOD, CREATE AND VIEW IRRIGATION BLOCKS , CROP UNITS AND FARM VIEW WITH LIVE IRRIGATION BLOCK STATUS, SATELLITE WEATHER INFORMATION BASED ON COORDINATES, MULTI MAINLINE OPERATION (UP TO 4 MAINLINES), REMOTE ACCESS THROUGH WEBVIEW AND MOBILE APP WITH PASSWORD PROTECTION, FLEXIBLE LOCAL 6 MODULES FOR OUTPUT, ANALOG INPUTS AND DIGITAL INPUTS CAPABILITY, INBUILT 12 DIGITAL INPUT AND 6 DIGITAL OUTPUT AND COMMUNICATION PORT, 256 OUTPUTS PER CONTROLLER WITH UPTO 102 LOCAL CONNECTIONS, MONITOR IN-FIELD IRRIGATION STATUS BY SOIL MOISTURE SENSORS WITH GRAPHICAL ANALYSIS AND WEATHER STATION, CAN BE OPERATABLE FROM ANYWHERE WITH MULTI LOGIN ACCESS), RTU UNIT WITH SOLAR PANEL AND ALL OTHER ACCESSORIES, SOIL TESTING AT THE FREQUENCY AS REQUIRED,CONTRACTOR HAS TO DIPLOY EXPERIENCED AGRICULTURAL ENGINEER, MACHINERY AND EQUIPMENT FOR EXECUTION, QUALITY CONTROL ARRANGEMENTS, PREPARATION&SUBMISSION OF PRODUCTION PLAN & OBTAINING CONSENT FROM FARMERS FOR LAYING PIPES AND ALLIED WORKS IN THEIR PROPERTY WITH THE ASSISTANCE OF KIIDC STAFF, MARKET STUDY, FORMING FARMERS ASSOCIATION AND ADVISING FARMERS ON CROP SELECTION BASED ON WATER AVAILABILITY, MARKET STUDY,AND ALL MATERIALS, FITTINGS, ADHESIVES SHALL BE AS PER THE SPECIFICATIONS AND STANDARDS OF BIS/INTERNATIONAL CODES, INCLUDING OPERATION AND MAINTENANCE FOR THREE YEARS AS MENTIONED IN THE TENDER DOCUMENTS. |
| 7 | CONSTRUCTION OF INTAKE WELL |
| 8 | 4.1.2:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | OD41623/2025-2026:Earthwork in open well excavation (above water) for wells of diameter above 2.5m and up to3.50m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m andlift up to 1.5m including neat banking.Hard rock (Blasting Prohibited) |
| 10 | OD41626/2025-2026:Earthwork in open well excavation (above water) for wells of diameter above 2.5m andup to 3.50m in all kinds of soil and conveying and depositing the spoil within initiallead of 50m and lift up to 1.5m to 3m including neat banking.Hard rock (BlastingProhibited) |
| 11 | OD41627/2025-2026:Earthwork in open well excavation (above water) for wells of diameter above 2.5m and up to3.50m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m andlift up to 3m to 4.5m including neat banking.Hard rock (Blasting Prohibited) |
| 12 | 60.2.2:Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete |
| 13 | 60.2.3:Bailing out water using pump above 5 HP and Up to 10 HP-Bailing out water with engine and pump set above 5HP and up to 10HP, including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete |
| 14 | 60.2.4:BAILING OUT WATER USING PUMP ABOVE 10HP AND UP TO 20HP - Bailing out water with engine and pump set above 10HP and up to 20HP, including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete |
| 15 | 5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 16 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 17 | 5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 18 | OD39588/2025-2026:RING BUND Type II Putting up ring bund with earth fille gunny bags of top width 1.5mbottom width 3.0m height 3.0 m side and filling in between with earth to form ring bund andmaintaining the same leak proof till the completion of the work and clearing the site bydismantling the bund after completion of the work.etc.complete. |
| 19 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 20 | 100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete. |
| 21 | OD39587/2025-2026:Providing and laying in position machine batched and machine mixeddesign mix M-25 grade cement concrete for reinforced cement concrete work, using cementcontent as per approved design mix, including pumping of concrete to site of laying butexcluding the cost of centering, shuttering, finishing and reinforcement, including admixtures inrecommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improveworkability without impairing strength and durability as per direction of Engineer - in-charge. |
| 22 | OD47872/2025-2026:Sinking well (above water) for wells of diameter above 2.5m and up to 3.5m in all kinds of soiland conveying and depositing the spoil within initial lead of 50m and lift from 3.00m to 4.5mincluding neat banking |
| 23 | OD47894/2025-2026: Sinking well (above water) for wells of diameter above 2.5m and up to 3.5m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 4.5m to 6.0m including neat banking. |
| 24 | OVERHEAD WATER TANK (1.5 LAKH LITRE CAPACITY) |
| 25 | 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 26 | 2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil |
| 27 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 28 | 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 29 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 30 | 5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 31 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 32 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 33 | 2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 34 | 5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 35 | OD39586/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-25 gradecement concrete for reinforced cement concrete work, using cement content as per approveddesign mix, including pumping of concrete to site of laying but excluding the cost of centering,shuttering, finishing and reinforcement, including admixtures in recommended proportions asper IS: 9103 to accelerate, retard setting of concrete, improve workability without impairingstrength and durability as per direction of Engineer - in-charge. Note:- Cement contentconsidered in this item is @ 330 kg/ cum. All work above plinth level upto floor V level |
| 36 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 37 | 5.11.1:Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) |
| 38 | 5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 39 | 22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against anyleakage.For vertical surface two coats @0.70 kg per sqm |
| 40 | 22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against anyleakage.For horizontal surface one coat @1.10 kg per sqm. |
| 41 | 50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 42 | 10.6.2:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover |
| 43 | 10.7:Providing and fixing ball bearing for rolling shutters. |
| 44 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 45 | 13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) |
| 46 | 13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) |
| 47 | OD39585/2025-2026:Providing and fixing aluminium window of size 100x150 or nearest including all fittings as perdirection of Engineer-in-charge |
| 48 | 9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc |
| 49 | 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 50 | 13.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm |
| 51 | 10.16.3:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes |
| 52 | 10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 53 | 10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes |
| 54 | 100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete. |
| 55 | OD39584/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-25 gradecement concrete for reinforced cement concrete work, using cement content as per approveddesign mix, including pumping of concrete to site of laying but excluding the cost of centering,shuttering, finishing and reinforcement, including admixtures in recommended proportions asper IS: 9103 to accelerate, retard setting of concrete, improve workability without impairingstrength and durability as per direction of Engineer - in-charge. Note:- Cement contentconsidered in this item is @ 330 kg/ cum. All work upto plinth level |
| 56 | Electrfication |
| 57 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 58 | 1.12:Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 59 | 1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 60 | 1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 61 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 62 | 1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 63 | 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door |
| 64 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 65 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 66 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 67 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 68 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 69 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 70 | 5.19:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 71 | 5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 72 | 90.12.7.29:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp |
| 73 | 90.12.7.14:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 10 sq mm with factory made clamp |
| 74 | 9.1.7:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm) |
| 75 | 9.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm) |
| 76 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 77 | 90.12.7.33:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 150 sq mm |
| 78 | 90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 79 | 4.1.1:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness |
| 80 | 90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture |
| 81 | 90.12.7.36:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 300 sq mm |
| 82 | 90.12.1.19:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 70 sq mm |
| 83 | 9.1.26:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm) |
| 84 | 9.1.30:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm) |
| 85 | 9.1.12:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 70 sq. mm (35mm) |
| 86 | 1.55.3:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 87 | OD46248/2025-2026:supply and fixing ceiling fan of 1200mm sweep, including the down rod of standard length (up to 30cm) |
| 88 | OD46278/2025-2026:supply and fixing 63A 415V 2way neutral link in the existing meter board |
| 89 | OD46279/2025-2026:Supply and fixing 63A HRC fuse base with fuse link in the existing meter board |
| 90 | OD46280/2025-2026:Preparing drawings submitting in to electrical inspectorate obtaining approval and forwarding completion report, arranging site inspection, obtaining energization sanction approval then forwarding completion report KSEB for availing HT/LT supply complete work, preperation of drawings including soil earth resistivity test and calculation of earth system as per IS 3043. |
| 91 | OD46281/2025-2026:Supply , installing and commisioning of outdoor 11KV/433V 315KVAtransformer with DP structure also including primary side control and protection (A.b switch,lightning arrester, D.o fuse) and secondary control and protection (MCCB having isolation dutyand E/F release and stand by low set E/f relay using CT at neutral earthing conductor or ACBwith propoer current setting facility with 3 O/C and 1 E/f realease |
| 92 | OD46282/2025-2026:M S B ( m a i ns w i t c h board):Supply,installation,test ing and commissiong of MSB panelfabricated out of 16SWG CRCA sheet ,powder coated dust and vermin tight proof,front openingtype, cable top/ bottom entry type,flush , floor mounted and also including base frame(incomer:630A 36KA 4pole MCCB-1 nos, outgoing:250A 23KA 4pole MCCB-4 nos , 63A 4pole MCCB-1 nos and also include suitable aluminium bus bar dimension) |
| 93 | OD46283/2025-2026:OD20413/2023-2024 -APFC(Automatic power f a c t o rc o n t r o l panel):Supplying, Installation, T e s t i n g& a m p; Commissioning of floor mountedsupported compartmentalized indoor type dust, weather andvermin proof cubical 150KVAr , (1 x 50KVAR + 1 x 20 KVAR + 2x 15 KVAR + 4 x 10 KVAR+ 1 x 5 KVAR)APFCR panel i/c capacitor, contactor,relay ofsuitablecapacity, fabricated out of2 mm thick CRCA Sheet Steel of suiatble size depth not less than 400mm with hinged door andsuitable for continous operation on 3 Phase 415 V, 50 Hz, 4 wire AC supply with detachablegland plate in cable alley including providing and fixing following switchgears andaccessoriestherein c o n n e c t i o n sa n d interconnections with PVC insulated multi strandcopper flexible conductor duly sleeved, tag, lugs etc and painted with powder coated paint aftereight tank treatment, earthing the body etc. as required. |
| 94 | OD46284/2025-2026:METERING PANEL :Supply, installation,testing and commissioning of meteing panel eather proof water resistantmaterial and panel fabricated with 16SWG CRCA sheet , CT unit, PT unit, NCT included(excluding HT TOD meter) |
| 95 | OD46285/2025-2026:Supply and fixing following capacity TP & N disconnector fuse switch unit with sheet steelenclosure directly on wall using suitable anchor bolts as required- 160A TPN SFU |
| 96 | OD46286/2025-2026:Supply and fixing metal body, Rust resistant and weather- proof Bulk head light fixture with 9W LED lamp,IP65 protection complete with all other accessories as required |
| 97 | OD46287/2025-2026:supply of first Aid kit and 11kv Gloves |
| 98 | OD46288/2025-2026:supply and fixing HT, LT Electrical danger board |
| 99 | OD46289/2025-2026:supply and fixing BCE type fire extinguisher 5kg |
| 100 | PUMP ROOM |
| 101 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 102 | 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 103 | 4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 104 | 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 105 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 106 | 5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 107 | 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 108 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 109 | 10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 110 | 12.1.3:Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/m2 |
| 111 | 10.13.2:Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee- sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with carbon steel galvanised dash fastener of required dia and size ( to be paid for separately) |
| 112 | 9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding |
| 113 | 10.6.2:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover |
| 114 | 10.7:Providing and fixing ball bearing for rolling shutters. |
| 115 | 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 116 | 13.17:6 mm cement plaster 1:3 ( 1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. |
| 117 | 9.167:Providing and fixing 6mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. on the backing of racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge. |
| 118 | 12.4.1:Providing ridges or hips width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.80 mm thick with zinc coating not less than 275 gm/m2 |
| 119 | 12.5.1:Providing valleys of 90 cm wide overall in plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limper and bitumen washers complete:1.60 mm thick with zinc coating not less than 350 gm/ m2 |
| 120 | 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 121 | OD41010/2025-2026:Providing and fixing 1 mm thick M.S. sheet door or window with frame of 40x40x6 mm angleiron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete,including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm fordiagonal braces Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail