| 1 | Demolition of cement concrete (unreinforced ) in floors and pavings n. exc 15cm thickness (above or below GL) complete all as specified and directed. |
| 2 | Taking down cement or cement lime plaster or stone / brick wall, ceiling including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 3 | M&L 15mm thick rendering in cement mortar (1:4) mixed with water proofing compound, on other than fair faces of brick / stone masonary surfaces, finished even and smooth without using extra cement,Incl preparation new decorated surfaces of walls for applying Two coats of weather coat paint over one coat of base/primer coat complete all as specified and directed.Note : WPC measured and paid separately. |
| 4 | M&L 15mm thick rendering in cement mortar (1:6), on other than fair faces of brick / stone masonary surfaces, finished even and smooth without using extra cement,Incl preparation new decorated surfaces of walls for applying Two coats of Plastic emulsion paint over one coat of base/primer over 1 mm thick wall care putty complete all as specified and directed. |
| 5 | M&L 5mm thick rendering in cement mortar (1:3) on stone putty slab, over POP alongwith putty 2 layer on ceiling, stone/ concrete surfaces, finished even and smooth Incl preparation new decorated surfaces of walls for applying Two coats of Plastic emulsion paint over base coat of primer complete all as specified and directed. |
| 6 | Dismantling loose / disintergrated portion of RCC Chajjas, bend shelves, beams balconies and similar work at any position or any height and doubbing out with PCC 1:1.5:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished required shape including applying anti corrosive paint on exposed surfaces and provision of necessary supporting form work and including 10mm thick plastering in CM 1:4, finished fair and even,Incl preparation new decorated surfaces of walls for applying Two coats of weather coat paint over one coat of base/primer coat complete all as specified and directed. |
| 7 | M&L for rough cast plaster over 10mm thick cement plaster in cement mortar 1:4 on stone / brick masonary wall surfaces Incl preparation new decorated surfaces of walls for applying Two coats of weather coat paint over one coat of base/primer coat complete all as specified and directed complete all as specified and directed. |
| 8 | Taking down existing tar felt or of any description including cement plaster or concrete of any thickness from the roof surfaces of building including cleaning the surfaces in all respect & preparing it for further treatment & removing rubbish from site complete all as specified and directed. |
| 9 | M&L for cutting out cracks to 'V' section in existing roofs or terracing, cleaning out and filling solidly with hot mixture of bitumen and clean dry sand 1:1(by weight ) complete all as specified and directed. |
| 10 | M&L for rendering 10mm thick in CM 1:4 mixed with water proofing compound @ 3% by weight of cement on fair faces of RCC/stone patti roof surfaces finished even & smooth without using extra cement complete all as specified and directed.Note : WPC will be measured and paid separately. |
| 11 | M&L roof treatment with APP modified polymeric water proofing membrane, 3mm thick having centre core not less than 100 mircron high molecular high density polyethylene film (HMHDPE) protected on both sides with high polymeric asphaltic mix and 20 mircron HMHDPE film weight not less than 3.0 kg/ Sqm applied with bonding material using blown type bitumen primer Grade 85/25 @ 1.20 Kg/Sqm over bitumen primer conforming to IS -3384 @ 0.40 Kg /Sqm with final coat of bonding bitumen grade 85/25 @ 1.20 Kg /Sqm over APP membrane with all overlaps complete all as specified and directed. |
| 12 | Material and labour for 40mm thick (avergae consolidated thickness) PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate complete all as specified and directed. |
| 13 | Demolition of Stone slabs and tiles laid bedded and jointed in any mortar of any description or thickness in floors, aprons etc. complete all as specified and directed. |
| 14 | M&L for 100 mm thick PCC 1:2:4 type B-1 (using 20 mm thick crushed stone aggregate) as in sub base complete all as specified and directed. |
| 15 | M&L for machine cut Kota stone slab flooring 20-25mm thick over 15mm thick screed bed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 16 | M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed 10mm thick in CM (1:4) & jointed with grey cement slurry mixed with pigment to match the smooth of the slab incl rubbing & polishing complete all as specified and directed. |
| 17 | M&L cement concrete type D-2, 1:4:8 (40 mm graded aggregate), 100 mm thick, complete all as specified and directed. |
| 18 | M&L for 400x400 mm 12 to 15 mm thick coloured matte finish heavy duty vetrified parking tiles in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including laid with adhesive/admixture of tiles complete all as specified and directed. |
| 19 | Dismantling structural steel work including doors gates but excluding framed truss etc complete all as specified and directed |
| 20 | S&F Mild steel pipes/ rolled sections Fe 410 -W (Gde- E- 250) quality- A as in framing for cladding, rafters; purlins fixed with angle cleats or other connecting plates,door chowkats ,coolar stands and water tank staging complete all as specified and directed. |
| 21 | M & L for two coats of synthetic enamel paint over a priming coat of red oxide after preparation of new surfaces of any description, over 10cm in width or girth,not otherwise described complete all as specified and directed. |
| 22 | M & L for two coats of synthetic enamel paint over a priming coat of red oxide after preparation of Old surfaces of any description, over 10cm in width or girth,not otherwise described complete all as specified and directed. |
| 23 | Dismantling of AC sheet (corrugated or semi corrugated etc) including AC ridges in large patches as in roof covering complete all as specified and directed. |
| 24 | M&L pre-painted profile galvalume aluminium zinc coated GI based corrugated steel sheet 0.5 mm thick of an colour having tensile strength og 550 Mpa as in roof covering/cladding/ridge to wall, fixed with self tapping screws complete all as specified and directed. |
| 25 | Demolition of stone/ brick masonry built in cement or cement lime mortar as in portion ordered complete all as specified and directed. |
| 26 | M&L for Random Rubble stone walling uncourses, built in CM (1:6) complete all as specified and directed. |
| 27 | All as per item No 26.00 above but except stone complete all as specified and directed. |
| 28 | M&L for brick work with flyash bricks straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. |
| 29 | Hammer dressing with maximum depression on face from straight edge held against the dressedsurface n exc.20mm Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed. |
| 30 | S&F Second class HW, Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed. |
| 31 | S&F in repairs 25mm dia ss curtain rod and decorative type knobs and required curtain rod bracket with chromium plated U shaped support clamp suitable for 25mm dia rod complete all as specified and directed. |
| 32 | Taking down 100mm / 75mm dia AC/PVC/CI pipe (any size or pattern ) including all fitting, heads, shoes, bends and removing from sites complete all as specified and directed. Note : Measured over all as fixed along the centre line over the fittings and accessories) |
| 33 | S&F 110mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall or laid in floors / trenches with & including existing / new MS stack clamps of FI 50 x 3mm complete all as specified and directed. |
| 34 | S&F 110mm bore PVC (SWR) bend / shoe of any radius with access door, complete all as specified and directed. |
| 35 | M&L PCC (1:3:6) type C-1 using 20mm graded stone aggregate, 75mm thick as in plinth protection finished fair & even laid in alternative bays n. exc 2M in length and joints filled with bitumen mastic 1:3 complete all as specified and directed. |
| 36 | Supply only liquid water proofing compound of approved quality and make confirming to IS complete all as specified and directed. |
| 37 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed. |
| 38 | M&L point wiring using approved colour codeing as per IS with zero halogen flame retatdent (HFFR) smoke free non toxic,non corrosive with copper cable 1.5 sqmm nominal area single core insulated and unsheathed stranded cable 1100 volt grade and including 20mm medium grade ERW stove (Black) enameled concealed conduit heavy duty ISI marked and unsheated copper conductor 1.5 sqmm area as earth wire as earth continuity conductor upto Switch flame proof rotary type complete all as specified and directed. |
| 39 | All as per item No 38.00 above but with 2.5 Sqmm zero halogen flame retatdent (HFFR) smoke free non toxic,non corrosive with copper cable for Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed. |
| 40 | Supply and fixing Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed. |
| 41 | Supply and fixing Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed. |
| 42 | Supply and fixing LED light fitting 2 x 8 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. |
| 43 | S&F flame proof distribution board SPN 8 way with busbar weather proof in cast aluminium LM-06 enclosure open by externally spring type knobes complete with M 25 cable entry to suit incoming cable end 02 Nos M 20 cable entry for outgoing cables from bottom suitable for fixing on wall duely epxy powder coated with flame proof flexible metallic conduit upto 01 mtr length,including 01 no SPN MCB 20 Amps and MCB SP 10 Amps-06 Nos. complete all as specified and directed. |
| 44 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed. |
| 45 | Supply and fixing tubes light grade GI tubing 40 mm dia with all fitting laid in trenches complete all as specified and directed. |
| 46 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and directed. |
| 47 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and directed. |
| 48 | Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 49 | Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly complete all as specified and directed. |
| 50 | M & L for laying of bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed. |
| 51 | M & L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work in any type of soil & disposal of soi, providing alternate layers of charcoal and common salt, constr of PCC earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover with handle made out oof 8mm dia bars, watering arrangement with funnel & wire mesh, complete all as specified and directed. Note : The unit rate includes for protection pipe and GI wire 4.00 mm from top of earth plate up to 7.5 meter above ground level. Please Enable Macros to View BoQ information |
| 52 | M & L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work in any type of soil & disposal of soi, providing alternate layers of charcoal and common salt, constr of PCC earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover with handle made out oof 8mm dia bars, watering arrangement with funnel & wire mesh, complete all as specified and directed. Note : The unit rate includes for protection pipe and GI wire 4.00 mm from top of earth plate up to 7.5 meter above ground level. Please Enable Macros to View BoQ information |