| 1 | NOTE: Schedule ‘A’ Part - I to Part -VI are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. |
| 2 | Total amount of Sch 'A' Part - I (BUILDING WORKS) |
| 3 | Total amount of Sch 'A' Part - II (SITE CLEARANCE/ AREA DEVELOPMENT/ EXCAVATION AND EARTHWORK) |
| 4 | Total amount of Sch ‘A’ Part - III (INTERNAL ELECTRIFICATION WORKS) |
| 5 | Total amount of Sch ‘A’ Part - IV (INTERNAL WATER SUPPLY) |
| 6 | Total amount of Sch ‘A’ Part - V (SEWAGE DISPOSAL) |
| 7 | Total amount of Sch ‘A’ Part - VI (ROAD/ PATH) |
| 8 | Total amount of Sch ‘A’ Part - VII (EXTERNAL WATER SUPPLY) |
| 9 | Total amount of Sch ‘A’ Part - VIII (EXTERNAL ELECTRIFICATION WORKS) |
| 10 | Total amount of Sch ‘A’ Part - IX (HOT WATER SUPPLY) |
| 11 | SCH 'A PART - X (Miscellaneous B/R and E/M works for Sch 'A' Part-II to Part-VI)Note: This schedule is not pre-priced by MES and the rate indicated as \\"Rs 0.00\\" under Col 5 signifies this fact only |
| 12 | Point wiring with 1.5 Sqmm (nominal area) copper conductor FRLS cable (multi-stranded) PVC insulated and sheathed electric cable 1100 volts drawn through and including PVC Conduit of suitable size (as per conductor run) with all fittings and accessories and including PVC insulated unsheathed electric cable 1100 volts 1.5 Sqmm (multi-stranded) copper conductor single core (green colour) as continuous earth wire connected to common earth dolly including MS/ GI sunken boxes covered with 3mm thick plastic laminated sheet ISI marked for following complete :- |
| 13 | One light/fan point controlled by one 5 Amps one way switch |
| 14 | One 3 pin socket outlet 5 Amps on independent board |
| 15 | 1.3 One 3 pin socket outlet 5 Amps on same board |
| 16 | Point wiring for power point with 2.5 sqmm (nominal area) copper conductor FRLS cable ( multi-stranded) PVC insulated and sheathed cable conductor 1100 Volts drawn through and including PVC Conduit of suitable size (as per conductor run) with all fittings and accessories and including PVC insulated unsheathed electric cable 1100 volts 2.5 Sqmm copper conductor single core (green colour) as continuous earth wire connected to common earth dolly including MS/ GI sunken boxes covered with 3mm thick plastic laminated sheet ISI marked complete.Note for Srl Item No 12 & 13 here-in-before : (i) The rates quoted against these items shall be inclusive of cutting chases, pinning in for concealed conduit wiring, making good the surfaces using Cement Mortar 1:3, cutting exceeding 10 cm but not exceeding 20cm girth.(ii) Screw used for conduits, ceiling roses, sunken boxes, for fixing plastic laminated sheet etc. shall be of Nickel/ Cadmium. |
| 17 | Sub main wiring for circuit/ submain wiring along with earth wire FRLSH PVC insulated copper conductor of size 2 x 10.00 sqmm and 1 x 10.00 sqmm earth wire single core cable drawn through and including PVC concealed conduit complete. |
| 18 | Sub main wiring for circuit/ submain wiring along with earth wire FRLSH PVC insulated copper conductor of size 2x6.0 sqmm and 1 x 6.0 sq. mm earth wire single core cable drawn through including PVC concealed conduit complete. |
| 19 | Sub main wiring for circuit/ submain wiring along with earth wire FRLSH PVC insulated copper conductor of size 2x 2.5 sqmm and 1 x 2.5 sq. mm earth wire single core cable drawn through including PVC concealed conduit complete.The work includes cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm but not exc 20 cm girth complete all as specified and directed. Note for Srl Item No 14 to 16 here-in-before : (i) The rates quoted against these items shall be inclusive of cutting chases, pinning in for concealed conduit wiring, making good the surfaces using Cement Mortar 1:3, cutting exceeding 10 cm but not exceeding 20cm girth.(ii) Screw used for conduits, ceiling roses, sunken boxes, for fixing plastic laminated sheet etc. shall be of Nickel/ Cadmium. Note : Two run of single core FRLS PVC cable with one run of earth conductor and conduit shall be measured as one unit. |
| 20 | Rechargeable LED Bulb 9 W, 220 V, white color all as specified and as directed. |
| 21 | GI Pipe (medium grade, ISI Marked) 32 mm dia,1.5 mtr long, bend to shape for street light fitting bracket with 2x pairs of MS clamps of suitable length of size 40x5 mm of MS flat iron with nuts bolts and washer and taking out old one including connection with street light complete all as directed. |
| 22 | 40W Tube insect catcher electric insect killer indoor type (fly swatter) with complete connection complete all as specified and directed. |
| 23 | Duct type chimney with inbuilt exhaust fan of capacity 200 Watt with minimum air flow 400 cum per hour, from opening top of kitchen platform opening 1.5m x 0.60m with all insulation and fitting complete all as specified and directed. |
| 24 | M&L for Elestometric Nytral rubber insulation to PP-R pipes suitable for 20mm outer dia 22/19mm thick with chiken wire mesh wire netting 25mm gauge, 20mm mesh with including 0.5mm thick aluminium sheet cladding including jointing and fixing material such as solvent adhesive SR-998 complete all as specified and directed by Engr-in-Charge. |
| 25 | All as per Srl item No 21 above, but of size 25 mm dia. |
| 26 | Supply, Installation, testing & commissioning of self supporting totally enclosed double door at front, LT feeder pillar box compartmentalized design, dust and varmin proof of size 1200 mm(Height) x 1000 mm(Length) x 800 mm(Width) suitable for 440 Volt 3 phase 4 wire system made out of 3.15 mm thick CRCA sheet and built upon rigid frame work having front and rear hinged doors with neoprene rubber gasket including danger plate, earthing strip point and, ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size of Zinc/Chromium plated nuts, bolts and washers etc. The panel shall be synthetic enamelled painted and the control circuit diagram shall be with colour code solid conductor copper 1.5 sqmm cable for easy identification including incoming/outgoing cable holes at the bottom, complete after taking down the old unserviceable one. The Panel shall be emmbeded with 75 x 75 x 6 mm MS Angle Iron frame and to be grouted in PCC foundation (1:2:4 ) type B2 upto a height of 50 cm from normal ground level complete all as specified and directed by Engr in charge and comprising of the following:- |
| 27 | (a) Aluminium bus bar 200 amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.(b) MCCB, 125 A, 4 pole with breaking capacity of 16 KA, Make : L & T/Havells - 01 No.(c) MCCB, 63 A, 4 pole with breaking capacity of 16 KA, Make : L & T/Havells - 03 No.(d) LED Indicating lamps for Main Supply indicating R', Y' B' - 01 Set of 3. (e) Digital Voltmeter (Make AE/L&T) - 01 No.(f) Current Transformer having Ratio 200/5, 15 VA - 01 Set of 3.(g) Digital Ammeter ( Make(AE/L&T) - 01 No. |
| 28 | Supply, install, test and commissioning of 58.5 KVA/46.5 KW with the provision of cold start functionability diesel engine driven Generating set with alternator out put Voltage 415 Volts +/- 1% at set value of 415 V at a frequency 50HZ +/- 0.5%, suitable for prime duty with STD control panel outdoor type IP-54 consisting of AMF feature to be erected, (NTP for suitable for installing at Base Camp (altitude of 3600m), all mounted in acoustic enclosure and Control panel as per manufacturer's design and specification confirming to latest norms of CPCB IV+ complete with the following and connected accessories and depositing to MES store yard with necessary T&P complete :-i) DG Fuel tank of minimum capacity 200 Ltrs with fuel gauge etc complete fixed with suitable foundation frame, grouted on floor with connecting fuel pipelines from main fuel tank to DG fuel tank all as per OEM recommendationsii)Battery & Leads iii)Silencer-Hospital type with pipe line & radiator as per OEM design & recommendations complete as per latest CPCB normsiv)AVM Padsv)First Fill of Lubevii)Acoustic Enclosureviii)Standard Control Panel( AMF) outdoor type with connected switchgear/relays/meters complete IP-54. Please Enable Macros to View BoQ information |
| 29 | Supply, install, test and commissioning of 58.5 KVA/46.5 KW with the provision of cold start functionability diesel engine driven Generating set with alternator out put Voltage 415 Volts +/- 1% at set value of 415 V at a frequency 50HZ +/- 0.5%, suitable for prime duty with STD control panel outdoor type IP-54 consisting of AMF feature to be erected, (NTP for suitable for installing at Base Camp (altitude of 3600m), all mounted in acoustic enclosure and Control panel as per manufacturer's design and specification confirming to latest norms of CPCB IV+ complete with the following and connected accessories and depositing to MES store yard with necessary T&P complete :-i) DG Fuel tank of minimum capacity 200 Ltrs with fuel gauge etc complete fixed with suitable foundation frame, grouted on floor with connecting fuel pipelines from main fuel tank to DG fuel tank all as per OEM recommendationsii)Battery & Leads iii)Silencer-Hospital type with pipe line & radiator as per OEM design & recommendations complete as per latest CPCB normsiv)AVM Padsv)First Fill of Lubevii)Acoustic Enclosureviii)Standard Control Panel( AMF) outdoor type with connected switchgear/relays/meters complete IP-54. Please Enable Macros to View BoQ information |