| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 2 | Demolition of stone, brick/PCC block masonry work built in cement mortar complete all as directed. |
| 3 | Demolition of cement concrete (un reinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) complete all as directed. |
| 4 | Dismantling timber scantlings 40 sq. cm and over in section, in any position, unframed work |
| 5 | Dismantling timber in fillets, rails, posts, rafters,purlins, etc. under 40 sq. cm in section |
| 6 | Dismantling plain or corrugated steel sheeting any thickness, complete all as specified and directed. |
| 7 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets. |
| 8 | Taking down chowkhats or frame n.exc 1.5 sqmtr(without taking off shutters from frames), complete all as specified and directed. |
| 9 | Taking down chowkhats or frame exc 1.5 sqmtr but n.exc 4 sq m(without taking off shutters from frames), complete all as specified and directed. |
| 10 | M&L for Providing precast cement concrete type C1 1:3:6 (20mm graded stone aggregate) solid building blocks or slabs exc 10cm thick (with plain or interlocking joints as directed)setting in mortar 1:6 ,complete, in walls |
| 11 | M&L for Providing precast cement concrete type B1 1:2:4 (20mm graded stone aggregate) solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed)setting in mortar 1:6 ,complete, in walls |
| 12 | Supplied only liquid WPC |
| 13 | M & L for Second class hard-wood in scantlings, clean sawn timber unframed and fixed. |
| 14 | S & F 30mm thick 1st class HW Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkat. |
| 15 | S & F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. |
| 16 | Supply and fix Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specifie |
| 17 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 18 | M&L for 6mm thick plywood, (5 Nos of ply)grade BWR, type BB, fixed with nails to timber framework. In wall partitions. |
| 19 | M&L for 75 mm thick cement concrete 1:3:6 type C2 ( using 20 mm graded stone aggregate) as in floor /base coat. |
| 20 | M&L for 40 mm thick cement concrete 1:2:4 type B1 ( using 20 mm graded stone aggregate) as in floor /base coat. |
| 21 | M&L coloured glazed ceramic tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl 10mm thick rendering in CM (1:6) on brick or concrete surfaces complete all as specified and directed. |
| 22 | M&L for 10mm thick rendering in CM (1:4) over block/concrete wall surfaces finished even and smooth without using extra cement. |
| 23 | M&L for Rendering 15 mm thick CM (1:6) on fair faces in two layers of concrete surfaces of wall , finshing the surface even and smooth without using extra cement complete. |
| 24 | M&L Rendering 15mm thick CM (1:4) in two layers on fair faces of concrete surfaces of walls mixed with LWPC by weight of cement as per manufacturers instruction , finshing the surface even and smooth without using extra cement complete.(Note : LWPC measured and paid separately) |
| 25 | M&L for prep of newly plastered surfaces of walls and applying 3mm thick wall care putty then two coats of OBD over coat of primer complete all as specified and as directed complete. |
| 26 | M&L for prep of newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed complete. |
| 27 | M&L for 4mm thick sheet glass of ordinary quanlity and glazing with oil putty in squares n exc 0.5 sq.m in each pane. |
| 28 | M&L for prepration of new wooden surfaces exc.10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 29 | M & L for preparation of new steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified. |
| 30 | Preparing of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 31 | M & L for PCC 1:4:8 Type D-2 (using 40mm graded aggr) as in foundations, filling and mass concrete. |
| 32 | S&F 2nd class HW plain solid straight chowkhats and frame wrought framed rebated on the soild rounded or chamfered put together with glue pinned at joints, complete all as specified and directed. |
| 33 | S & F 30 mm thick 1st class HW flush shutters,solid core construction with block board core and plywood face panel, commercial type on both sides, complete all as specified and directed. |
| 34 | Supply and fix Aluminium anodized barrel tower bolts of extruded section, 100 mm long, complete all as specified and directed. |
| 35 | Supply and fix Aluminium anodized barrel tower bolts of extruded section, 150 mm long, complete all as specified and directed. |
| 36 | S & F Aluminium alloy, anodised, sliding door bolt 250mm length with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed. |
| 37 | Supply and fix mild steel butt hinges, medium weight, cold rolled 100 mm size , complete all as specified and directed. |
| 38 | Supply and fix mild steel butt hinges, medium weight, cold rolled 125 mm size , complete all as specified and directed. |
| 39 | Supply and fix Aluminium handles, cast type, anodized, 125 mm size , complete all as specified and directed. |
| 40 | Supply and fix Aluminium handles, cast type, anodized, 150 mm size , complete all as specified and directed. |
| 41 | M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound destemper, over a coat of primer complete all as specified and directed. |
| 42 | Taking down carefully aluminium point wiring (light, fan, socket or power) complete and making good disturbed surfaces of walls, floors, etc. all as directed.including taking down fittings such as switches, ceiling roses, regulators, sockets,lamp holders etc. |
| 43 | M&L for point wiring with two runs of FRLSH PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC Conduit of size not less than 20mm on surface of wall including provn of PVC box/modular metal flush box of suitable size for mounting switch, socket and regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm all as specified and directed.One light/fan/call bell point controlled by one switch one way 5 Amps |
| 44 | All as per Sl Item no.43 but with One 2/3 pin socket outlet 5Amps on independent board |
| 45 | All as per Sl Item no.43 but with One 3 pin socket outlet 5 Amps on the same board with other switches |
| 46 | All as per item No 43 above but 3 pin socket out let 15/16 Amps on the independent Board all as spfd with single core unsheathed PVC insulated cable multistranded copper conductor of size 2.5 sq mm for phase & neutral & 2.5 sq mm for earth continuity conductor. |
| 47 | S&F Switch piano, flush type single pole, one way 5 Amp.all as specified and directed. |
| 48 | S&F Socket outlet 2 in 1, 3 pin, 6A.all as specified and directed. |
| 49 | S&F Switch socket combination 2 in 1, 5 A flush type.all as specified and directed. |
| 50 | S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type Universal.all as specified and directed. |
| 51 | Supply and fix in repair Modular switch 1way 6A,1moduleall as specified and directed. |
| 52 | Supply and fix in repair Modular switch 1way 16A,1module all as specified and directed. |
| 53 | Supply and fix in repair Modular socket, 6A-2/3 pin combined 2 module all as specified and directed. |
| 54 | Supply and fix in repair Modular socket, 6A/16A-2/3 pin combined 2 module all as specified and directed. |
| 55 | S&F ceiling rose surface bakelite 3 terminals 65x50mm all as directed. all as specified and directed. |
| 56 | Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete as specified. |
| 57 | Supply and fixing LED light fitting mirror Glamtubes Vanessa(LHEWAJPGV1G020) 20 watt 3000K , 600mm ,220 V AC decorative type including connecting up with three core flexible copper conductor cable of suitable size complete as specified. |
| 58 | Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed /surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 59 | Supply and fixing round /square shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 60 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete as specified. |
| 61 | S & F Lamp holder, PVC/Polycarbonate type with back plate suitable for battern fittings complete. all as specified and directed by as engineer-in-charge. |
| 62 | S&F LED Bulb 9 watt cat part no LED ADORE 9W B22 WW 2 STAR LAMP complete all as specified and as directed by engineer-in-charge. |
| 63 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep heavey duty with, blades, and frame and louvers with all fixing arrangement all as specified and as directed. |
| 64 | Supply only modular white cover plate with frame, 2 module ISI marked complete all as specified and as directed. |
| 65 | Supply only modular white cover plate with frame, 3 module ISI marked complete all as specified and as directed. |
| 66 | Supply only White cover plate with frame, 4 module ISI marked complete all as specified and as directed. |
| 67 | Supply and fix White cover plate with frame, 6 module ISI marked complete all as specified and as directed. |
| 68 | Supply only White cover plate with frame, 8 module ISI marked complete all as specified and as directed. |
| 69 | S&F sheet metal enclosure distribution box 4 way TPN 415 volts with suitable size of rated bus bar double door complete including connecting up all as specified . |
| 70 | Supply and fixing in repair 415V 10KA 'C' curve miniature circuit breaker TPN 40 To 100 AMP poles and current carrying capacity in the DB complete with connection testing and commissioning all as directed and as specified. |
| 71 | Supply and fixing in repair MCB 32 Amp SPN 240V, 10KA 'C' complete with connection testing and commissioning all as directed and as specified. |
| 72 | Supply and fixing in repair MCB 5- 32 Amp SP 240V, 10KA 'C' complete with connection testing and commissioning all as directed and as specified. |
| 73 | Earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground surrounded from all sides by 15cm thick and packed layer of charcoal dust and conmmon salt filling in alternate layers connected to and including GI earth wire 4.0 mm dia upto 7.5 mtr by means of bolts, nuts, check nuts and washers, and protected by light grade 20 mm dia and connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel wire mesh, RCC pit cover 50mm thick with 10mm dia reinforcement 100mm c/c and PCC chamber pit with P C C 1:2:4 Type C2 (including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 metre and testing after completion including dismantling of old unserviceable earthing all as specified and shown on plate No 3 of SSR Part-I 2009 Please Enable Macros to View BoQ information |