Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-03-2026 | BOQ_Corrigendum | BOQ | 28-03-2026 |
| 2 | 20-03-2026 | BOQ_Corrigendum | BOQ | 04-04-2026 |
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (unreinforced ) in floors and pavings n. exc 15cm thickness (above or below GL) complete all as specified and directed. |
| 2 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 3 | Taking down cement or cement lime plaster or stone / brick wall, ceiling including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 4 | M&L 15mm thick rendering in cement mortar (1:4) mixed with water proofing compound, on other than fair faces of brick / stone masonary surfaces, finished even and smooth without using extra cement,Incl preparation new decorated surfaces of walls for applying Two coats of weather coat paint over one coat of base/primer coat complete all as specified and directed.Not : WPC measured and paid separately |
| 5 | M&L 15mm thick rendering in cement mortar (1:6), on other than fair faces of brick / stone masonary surfaces, finished even and smooth without using extra cement,Incl preparation new decorated surfaces of walls for applying Two coats of Plastic emulsion paint over one coat of base/primer over 1 mm thick wall care putty complete all as specified and directed. |
| 6 | M&L POP alongwith putty 2 layer on ceiling, stone/ concrete surfaces, finished even and smooth Incl preparation new decorated surfaces of walls for applying Two coats of Plastic emulsion paint over base coat of primer complete all as specified and directed. |
| 7 | Dismantling loose / disintergrated portion of RCC Chajjas, bend shelves, beams balconies and similar work at any position or any height and doubbing out with PCC 1:1.5:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished required shape including applying anti corrosive paint on exposed surfaces and provision of necessary supporting form work and including 10mm thick plastering in CM 1:4, finished fair and even,Incl preparation new decorated surfaces of walls for applying Two coats of weather coat paint over one coat of base/primer coat complete all as specified and directed. |
| 8 | M&L for rough cast plaster over 10mm thick cement plaster in cement mortar 1:4 on stone / brick masonary wall surfaces Incl preparation new decorated surfaces of walls for applying Two coats of weather coat paint over one coat of base/primer coat complete all as specified and directed complete all as specified and directed. |
| 9 | Taking down existing tar felt or of any description including cement plaster or concrete of any thickness from the roof surfaces of building including cleaning the surfaces in all respect & preparing it for further treatment & removing rubbish from site complete all as specified and directed. |
| 10 | M&L for cutting out cracks to 'V' section in existing roofs or terracing, cleaning out and filling solidly with hot mixture of bitumen and clean dry sand 1:1(by weight ) complete all as specified and directed. |
| 11 | M&L for rendering 10mm thick in CM 1:4 mixed with water proofing compound @ 3% by weight of cement on fair faces of RCC/stone patti roof surfaces finished even & smooth without using extra cement complete all as specified and directed (WPC will be measured and paid separately). |
| 12 | M&L roof treatment with APP modified polymeric water proofing membrane, 3mm thick having centre core not less than 100 mircron high molecular high density polyethylene film (HMHDPE) protected on both sides with high polymeric asphaltic mix and 20 mircron HMHDPE film weight not less than 3.0 kg/ Sqm applied with bonding material using blown type bitumen primer Grade 85/25 @ 1.20 Kg/Sqm over bitumen primer conforming to IS -3384 @ 0.40 Kg /Sqm with final coat of bonding bitumen grade 85/25 @ 1.20 Kg /Sqm over APP membrane with all overlaps complete all as specified and directed |
| 13 | Material and labour for 40mm thick (avergae consolidated thickness) PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate complete all as specified and directed. |
| 14 | Demolition of Stone slabs and tiles laid bedded and jointed in any mortar of any description or thickness in floors, aprons etc. complete all as specified and directed. |
| 15 | M&L for 25mm thick PCC 1:2:4 type B-1 (using 20 mm thick crushed stone aggregate) as in sub base complete all as specified and directed. |
| 16 | M&L for Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match ,laid over and including 15 mm thick screed bed in CM (1:4) complete all as specified and directed. |
| 17 | M&L for Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match ,laid over and including 15 mm thick screed bed in CM (1:4) complete all as specified and directed. |
| 18 | M&L for machine cut Kota stone slab flooring 20-25mm thick over 15mm thick screed bed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 19 | M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed 10mm thick in CM (1:4) & jointed with grey cement slurry mixed with pigment to match the smooth of the slab incl rubbing & polishing complete all as spd & directed. |
| 20 | M & L for Non-skid Ceramic tiles 7 to 8 mm thick ( square /Rectangular) area of each tile exceeding 0.11 sqm but not exc 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured in white or coloured cement to match with tile laid over and including screed bed or bedding layer of 15 mm thick in CM (1:6) complete all as specified and directed. |
| 21 | M&L glazed ceramic coloured tiles, size 450 mm X 300 mm, 6-7 mm thick on vertical surfaces of wall such as dados, skirting etc set & jointed in neat slurry and pointed in white or colour cement to match over 10 mm thick screed plaster in CM 1:4 complete all as specified and directed |
| 22 | M&L Outdoor paving tiles of area of each tiles exceeding 0.08 sqm but not exceeding 0.36 sqm, , scratch resistant, stain resistant, impact resistant & acid/alkali resistant , to withstand heavy loads and neutral to sun up effect, complete all as specified and as directed.Make : Johnson,Somany,kajaria and equivalent |
| 23 | M & L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and laid over and including screed bed or bedding layer of 15 mm thick in CM (1:6) complete all as specified and directed. |
| 24 | M&L cement concrete type D-2, 1:4:8 (40 mm graded aggregate), 100 mm thick, complete all as specified and directed. |
| 25 | M&L for 400x400 mm 12 to 15 mm thick coloured matte finish heavy duty vetrified parking tiles in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including laid with adhesive/admixture of tiles complete all as specified and directed. |
| 26 | Dismantling structural steel work including doors gates but excluding framed truss etc complete all as specified and directed |
| 27 | S&F Mild steel pipes/ rolled sections Fe 410 -W (Gde- E- 250) quality- A as in framing for cladding, rafters; purlins fixed with angle cleats or other connecting plates,door chowkats ,coolar stands and water tank staging complete all as specified and directed. |
| 28 | M & L for two coats of synthetic enamel paint over a priming coat of red oxide after preparation of new surfaces of any description, over 10cm in width or girth,not otherwise described complete all as specified and directed. |
| 29 | Dismantling of AC sheet (corrugated or semi corrugated etc) including AC ridges in large patches as in roof covering complete all as specified and directed. |
| 30 | M&L pre-painted menglore pattern profile galvalume aluminium zinc coated GI based corrugated steel sheet 0.5 mm thick of an colour having tensile strength og 550 Mpa as in roof covering/cladding/ridge to wall, fixed with self tapping screws complete all as specified and directed. |
| 31 | Dismantling Wall and ceiling boards/wall panelling (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 32 | Providing & Fixing false ceiling with Everest Fibre Cement Designer tile Ivory painted (High Pressure Steam Cured) of 4mm thickness (as per IS:14862) of size 595x595 mm and any one of the design (oceanic, lake & hill, cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and 15x32 mm made from 0.30 mm thick sheet, spaced at 1200 mm c/c and cross \\"T\\" of size 15x32 mm made of 0.30 mm sheet, 1200mm long spaced between main \\"T\\" at 600 mm c/c to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size15x32 mm made of 0.30 mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 15x20 mm made of 0.30 mm thick sheet and laying false ceiling tiles in the grid including , required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips, spaced at 1200 mm c/c along main T, bottom exposed width of 15mm of all T -sections shall be centra black pre-painted with polyester paint, and having a load bearing capacity of 12 kg/sqm, complete all as specified and directed. |
| 33 | S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame complete all as specified and directed. |
| 34 | S&F 5-8mm thick PVC wall cladding hollow cored and a tongue and grooved edge fixed with screw incl required PVC cleat at edges and at corner complete all as specified and directed. |
| 35 | Demolition of stone/ brick masonry built in cement or cement lime mortar as in portion ordered complete all as specified and directed. |
| 36 | M&L for Random Rubble stone walling uncourses, built in CM (1:6) complete all as specified and directed. |
| 37 | All as per item No 36.00 above but except stone complete all as specified and directed. |
| 38 | M&L for brick work with flyash bricks straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. |
| 39 | Hammer dressing with maximum depression on face from straight edge held against the dressed surface n exc.20mm Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed. |
| 40 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n exc 1.50 sqm each and removing from site complete all as spd & directed and making good disturbed surface of walls in cement mortar (1:3) complete all as specified and directed. |
| 41 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm and n.exc 4.00 Sqm each and removing from site complete and making good disturbed surfaces of wall in CM (1:3) complete all as specified and directed. |
| 42 | S&F powder coated anodised aluminium frame for doors,partition wall, windows, ventilators with one or more rebates including joining cleat , glazing clips, rubber packing, anodised aluminium snap beading, screws, hinges and rubber packing and fixture for movement and fixing etc. complete all as specified etc. complete all as specified |
| 43 | M&L for Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed. |
| 44 | M&L Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. |
| 45 | S&F in repair aluminium grill with and including suitable aluminium anodised frame F/H section as requird as per design No DG- 104 or equivatent 6.5 mm thick complete all as specified and directed. |
| 46 | S&F 5.5mm thick sheet glass exc 0.5 sqm with solar control filim 50 micron ordinary quality including necessary fixing items, complete all as specified and directed. |
| 47 | S & F sheet glass 4mm thick ordinary quality and glazing with oil putty / beads / pin in square not exc 0.50 Sq.m in each pane, all as specified and directed. |
| 48 | M & L in repairs Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed. |
| 49 | S&F Second class HW, Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed. |
| 50 | S & F Flush shutters 30mm thick, solid core construction, with block board core and plywood face panels commercial type on both side and both facesis covered with approved pattern with Decorative coloured laminate type 1 of 0.9 mm thick and all around side faces covered with 10mm thick 1st class hard wood liping duly polished complete all as specified and directed. |
| 51 | S&F II nd class HW, 35mm thick, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc divided into squares, with plain, chamfered or ounded, mitred and rebated sash bars, fitted with cut and mitred beads for securing glass etc, sizes of members shutters as specified in SSR Part I, selection 8, clause 8.24 (a), supplied and fitted to chowkhats complete all as specified and directed. |
| 52 | S&F 300mm long Stainless steel sliding door bolt with hasp and staple (bolt type) and fixing clips, complete all as specified and directed. |
| 53 | S & F in repairs 150mm long dual leg floor door stopper of alumunium alloy body and tongue anodised with hard drawn steel spring fixing on door, complete all as specified and directed. |
| 54 | S&F Solid PVC moulded Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing using single side prelam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet, reinforced with MS square tube and fixing in opening as specification & drawing complete all as specified and directed. |
| 55 | S&F factory made solid PVC moulded door shutter with wood free EPS, 28 to 30mm thick, (styles) with 2,4 or 6 raised panel design with 2mm thick moulded prelam (Nut Brown colour ) PVC sheet on the front face & 2mm prelam (Nut Brown colur ) PVC sheet on back face, and fixing inthe frame at site as per specification and drawing on page 161 of SSR (Part -II ) 2020 complete all as specified and directed. |
| 56 | S&F 150mm long aluminium anodised barrel tower bolts of extruded section compete all as specified and directed. |
| 57 | S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 58 | S&F 100mm butt hinges extruded aluminium alloy with galvanised mild steel hinge and anodised ISI marked and fixed, complete all as specified and directed. |
| 59 | S&F in repair Deco door seal size 1.5\\" width door bottom sealing strip draft Excluder stopper with aluminium plate & nylon bristles for weather stripping complete all as specified and directed. |
| 60 | S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of apertature 1.40mm and fixed with tinned tacks or stainless steel wire staples all as specified and directed. |
| 61 | S&F in repairs 25mm dia ss curtain rod and decorative type knobs and required curtain rod bracket with chromium plated U shaped support clamp suitable for 25mm dia rod complete all as specified and directed. |
| 62 | S&F in repair tubular towel rail brass chromium plated 20mm dia 'D' type 60cm long, complete all as specified and directed. Make: Prima or Equivalent. (Cat No.PSS-4503-A) |
| 63 | S&F in repair towel ring brass chromium plated, complete all as specified and directed.Make: Prima or Equivalent. (Cat No.PSS-4503-B) |
| 64 | S&F in repair Paper Holder brass chromium plated, complete all as specified and directed.Make: Prima or Equivalent. (Cat No.PSS-4503-F) |
| 65 | Supply and fixing in repair Glass corner shelf 300mm with brass brackets, complete all as specified and directed. Make : Prima or Equivalent (Cat No. PGS-3207) |
| 66 | S&F in repair vitreous china white table top wash basins (660x430x140mm) and connecting pipe complete all as specified and directed.Make : RAK Aurex or Euivalent |
| 67 | Taking out old unserviceable water closet and S & F padestal pattern Omega Siphonic flush alongwith soft close seat cover size 660 x330 x 720 mm, white (including atach flush tank alongwith all flushing cistern arrangements ) with ‘P’ or ‘S’ trap, front or back inlet including connection to trap and to flushing pipe, anti syphonage pipe , including PCC (1:2:4) type B-1 for fixing of WC and making good the floor to match the existing complete all as specified and directed. |
| 68 | Taking down old unserviceable urinal and S&F Vitreous China Urinal white colour, Half stall type,white incl waste pipe complete all as specified and directed. |
| 69 | S&F in repair health faucet cast copper alloy chromium plated with flexible chrome hose and wall hooks complete all as specified and directed.Make : Prima PHF-4302 |
| 70 | S&F cast copper alloy chromium plated bottle trap fixed to WHB and wall complete all as specified and directed.Make : Parryware T3201A1 or equivalent |
| 71 | S&F Rectangular LED Wall Mirror with Touch Sensor, 3 Light Modes & Backlit Illumination | Framed Bathroom & Bedroom Mirror, Wall Mounted (18x24 Inch) with frame, with chromium plated brass screws and cup washers fixed to wall complete all as specified and directed. |
| 72 | S&F in repair Soap dish fancy type, fixed to plugs with chromium plated brass screws embedded in the wall complete all as sped & directed. Make : Prayag or equivalent (Cat No. BA-15) |
| 73 | S&F in repair PVC connection, heavy duty 15mm bore, 60cm long with 2 Nos PTMT nuts of approved quality complete all as specified and directed. |
| 74 | S&F in repair, 15mm bore Brass CP basin mixer for mixing hot & cold water for wash basin screwed down for iron pipe and fixed complete all as specified and directed.Make : Prima or equivalent (Cat No. PSL-5812) |
| 75 | S&F in repairs 15mm bore cast copper alloy chromium plated fancy bib tap long body , screwed for iron pipe complete all as specified and directed. Make : Prima or equivalent (Cat No. PME-6002) |
| 76 | S&F in repair fancy type angle valves 15mm bore , cast copper alloy chromium plated, screwed down high pressure screwed both ends for iron pipe or for unions and fixed etc complete all as specified and directed. |
| 77 | Demolition and bracking up drain pipe SWG line set in CM of description, 150mm dia including side packing / haunching complete all as specified and directed.` |
| 78 | M&L for PCC 1:3:6 type C-2 using 40mm graded aggregate for bed concrete to drain pipe packing under hunching for sides for 150mm dia SWG pipe lines complete all as specified and directed. |
| 79 | M&L for 150mm dia in bore Reinforced concrete pipes, class NP 2 with one collar per length of pipe laid in trenches and jointed complete all as specified and directed. |
| 80 | M&L for concrete bed to drain pipes including packing under and haunching against the sides of pipe they are laid with PCC 1:4:8 type D-2 for pipe of 150mm dia in bore complete all as specified and directed. |
| 81 | Dismantling of RCC /PVC water tanks and removing to store exc 500 Ltr but n.exc 1000 ltrs capacity complete all as specified and directed. |
| 82 | S& F rotational moulded synthetic (HDPE) water storage tank 1000 litre capacity hoisted & fixed in position all as specified in SSR Part-I complete all as specified and directed. |
| 83 | S&F ball valves PTMT high pressure with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe, 20mm bore compete (Minimum weight 210 gm) complete all as specified and directed. |
| 84 | S&F in repairs gun metal globe or gate valve, wheel head cast copper alloy screwed down light pressure with crutch or butterfly handle screwed both ends for iron pipe or for union 20 mm dia, ISI marked complete all as specified and directed. |
| 85 | M&L in repair precast cement concrete louvers and jallies 35 mm thick made in Mix 1:2:4 type B0 using 12.5mm graded stone aggregate set in cement mortar 1:4 and jallies design as per site requirement complete all as specified and directed. |
| 86 | M&L RCC, type B-1 (1:2:4) using 20mm graded aggregate in, slab supported on wall, walls beams and columns in floors, roof landings complete all as specified and directed. |
| 87 | M&L form work for flat fair finished surfaces of concrete to soffits of suspended slabs such as roof slab not exceeding 200mm thick complete all as specified and directed. |
| 88 | Taking down old unserviceable 20mm GI tubing, fittings and connections and removing from site or keeping aside for refixing complete all as specified and directed. |
| 89 | S&F 20mm GI water tubing, medium grade, galvanised with all fittings ( and fixed to walls, ceiling or laid in floors/ trenches complete all as specified and directed. |
| 90 | Taking down old unserviceable 15mm GI tubing, fittings and connections and removing from site or keeping aside for refixing complete all as specified and directed. |
| 91 | S&F 15mm GI water tubing( Concealed type), medium grade, galvanised with all fittings ( and fixed to walls, ceiling or laid in floors/ trenches complete all as specified and directed. |
| 92 | Taking down 100mm / 75mm dia AC/PVC/CI pipe (any size or pattern ) including all fitting, heads, shoes, bends and removing from sites complete all as specified and directed. Note : Measured over all as fixed along the centre line over the fittings and accessories. |
| 93 | S&F 110mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall or laid in floors / trenches with & including existing / new MS stack clamps of FI 50 x 3mm complete all as specified and directed. |
| 94 | S&F 110mm PVC (SWR) junction single, (Single T) equal or unequal with access door with cement joint complete all as specified and directed. |
| 95 | S&F 110mm bore PVC (SWR) bend / shoe of any radius with access door, complete all as specified and directed. |
| 96 | S&F 75mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall or laid in floors / trenches with & including existing / new MS stack clamps of FI 50 x 3mm complete all as specified and directed. |
| 97 | S&F 75mm bore PVC (SWR) bend / shoe of any radius with access door, complete all as specified and directed. |
| 98 | S&F in repairs PVC (SWR) floor trap/ Nahani trap 75mm, plain with grating including jointing to waste pipe fixed in cement concrete type (1:2:4) complete all as specified and directed. |
| 99 | M&L PCC (1:3:6) type C-1 using 20mm graded stone aggregate, 75mm thick as in plinth protection finished fair & even laid in alternative bays n. exc 2M in length and joints filled with bitumen mastic 1:3 complete all as specified and directed. |
| 100 | Supply only liquid water proofing compound of approved quality and make confirming to IS complete all as specified and directed. |
| 101 | M&L for mild steel TMT bar 10 mm dia and over cut to length bent to shape required including cranking bending for hooking ends and binding with and including mild steel wire ( annealed) not less than 0.9mm dia or securing with clips conforming to all complete all as specified and directed. |
| 102 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 103 | M&L for point wiring with 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed in and including non metallic rigid PVC concealed conduit 20 mm dia or higher complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc./ fittings ISI marked and sunk type pressed steel anodised terminal box with bakelite laminated sheet top cover 3 mm thick, brass screws and cup washers including one green colour cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed of following :- |
| 104 | One light point/bell point/ceiling light/exhaust fan controlled by one way 5 Amps single pole switch, |
| 105 | One 5 pin 5 Amps socket outlet on same board with other switch, |
| 106 | One 5 Pin 5 Amps socket outlet on independent board with other switch, |
| 107 | All as per item No 103.00 above but with 2.5 Sqmm single core multi stranded PVC insulated unsheathed (FRLS) cable for 15 Amp socket outlet on independent board, complete all as specified and directed. |
| 108 | S&F in repair of switch piano type, flush button single pole, one way 5 Amps, complete all as specified and directed. |
| 109 | S&F in repair of switch piano flush type 15 amps, single pole one way 240 volts complete all as specified and directed |
| 110 | S&F in repair of socket outlet 5 Amps, 5 Pin, flush type, complete all as specified and directed. |
| 111 | S&F in repair of socket out let 2 in 1,multipurpose 3 pin 15/16 complete all as specified and directed. |
| 112 | S&F bell push piano flush type 5 Amp complete all as specified and directed. |
| 113 | S&F in repair stepped type ( switch type) electronic ceiling fan regulator flush type, AC, 230 volts , complete all as specified and directed. |
| 114 | S&F of door bell ding dong type electric 230 volts AC , single phase, complete all as specified and directed. |
| 115 | S&F in repair of ceiling rose,surface type bakelite 65 x 17.5 mm, three terminals, complete all as specified and directed. |
| 116 | S&F in repair in repair lamp holder with 9W LED Bulb PVC/polycarbonate type with back plate complete all as specified and directed. |
| 117 | Supply and fixing LED lights fitting 1 x 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 118 | S&F in repair in repair LED mirror light fitting, 10 watt, 600 mm length complete with all accessories pre-wired and including connecting up with flexible copper conductor cable with suitable size complete all as specified and directed. |
| 119 | S&F in repair in repair LED light fittings, 10 W bulk head luminaries 230V, 50 Hz complete with all accessories and including connecting up with three core copper conductor cable with suitable size complete all as specified and directed. |
| 120 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 121 | M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 4 Sqmm multi stranded copper conductor cable drawn through existing concealed conduit incl one run of green colour earth continuity conductor with 4 Sqmm multi stranded copper conductor cable complete all as specified and directed.Note : Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length. |
| 122 | S & F in repair of MCB SP, 240 volt, 6 Amp to 32 Amp capacity, 10 KA, 'C' curve complete all as specified and directed. |
| 123 | S&F in repair of MCB SPN 10 to 40 Amp capacity, 10KA , 'C' curve complete all as specified and directed. |
| 124 | S&F in repair in repair MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door, IP-43, DB's made out of CRCA sheet steel enclosure, recessed type, factory made powder coated, 8 way, 240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories etc complete all as specified and directed. |
| 125 | Supply and fix exhaust fan (BLDC) made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm including copper wire of size 0.5sqmm from ceiling rose to fan connector including Cutting openings, through bricks walls in round shape, for 250mm dia exhaust fan and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required including finishing up and matching the disturbed surface and removing surplus unserviceable bricks, hard-core etc from site and rubbish complete all as specified and directed. |
| 126 | Supply and fix including testing of electric water heater, storage type steel body with copperinner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Starrated complete with all accessories such as safety valve, thermostate,NRV, connection piece,Two No gate valve and one bib tap complete all as specified and directed. |
| 127 | Taking down UNSV Fan and deposite to MES Store yardSupply and fixing ceiling fans complete with blades, down rods, remote and accessories, 230 V, 1400 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete with motor, blade set of three nos , down rod, canopy, shackle assy complete all as specified and directed. |
| 128 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed. |
| 129 | Supply and fixing tubes light grade GI tubing 40 mm dia with all fitting laid in trenches complete all as specified and directed. |
| 130 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and directed. |
| 131 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and directed. |
| 132 | Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 133 | Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed. Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly. |
| 134 | M & L for laying of bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed. |
| 135 | M & L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work in any type of soil & disposal of soi, providing alternate layers of charcoal and common salt, constr of PCC earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover with handle made out oof 8mm dia bars, watering arrangement with funnel & wire mesh, complete all as specified and directed. Note : The unit rate includes for protection pipe and GI wire 4.00 mm from top of earth plate up to 7.5 meter above ground level. Please Enable Macros to View BoQ information |
| 136 | M & L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work in any type of soil & disposal of soi, providing alternate layers of charcoal and common salt, constr of PCC earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover with handle made out oof 8mm dia bars, watering arrangement with funnel & wire mesh, complete all as specified and directed. Note : The unit rate includes for protection pipe and GI wire 4.00 mm from top of earth plate up to 7.5 meter above ground level. Please Enable Macros to View BoQ information |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail