| 1 | Dismantling brick or stone masonry in lime or cement mortar under 3mtr height including stacking the useful materials for reuse and removing the debris within 50m lead. Per 1 cum |
| 2 | Dismantling G.C.I. or A.C. sheet roofing after carefully removing the bolts and nuts including stacking the useful materials for reuse and removing the debris within 50m lead. Per 1 sqm |
| 3 | Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead. Per 1 sqm |
| 4 | Dismantling and removing old tiled flooring including stacking the useful materials for reuse and removing the debris within 50m lead.Per 1 sqm |
| 5 | Earth work in excavation in hard soil or gravelly soil including dressing and levelling the bed |
| 6 | Sand filling as per approved drawing and technical specifications as per Section 2100 of MoRT&H Specifications for Road & Bridge works (4th Revision). |
| 7 | Plain cement concrete (1:4:8) nominal mix in foundation as per Drawing and Technical Specification |
| 8 | Plain cement concrete (1:2:4) nominal mix in foundation as per Drawing and Technical Specification |
| 9 | Fly ash brick masonry in cement mortar (1:6) using 23 Cm. x 11 Cm. x 8 Cm. size fly ash bricks having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % in foundation and plinth |
| 10 | Fly ash brick masonry in cement mortar (1:6) using 23 Cm. x 11 Cm. x 8 Cm. size fly ash bricks having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % in super structure |
| 11 | 12mm thick Cement Plaster (1:6) over Brick Masonry finished smooth in Ground Floor |
| 12 | 16mm thick Cement Plaster (1:6) over Brick Masonry finished smooth in Ground Floor |
| 13 | 6 mm thick cement plaster (1:4) to R CC surfaces finished smooth including closed deep chiping and slury treatment. in Ground Floor |
| 14 | Wall Painting two coats with approved Distemper in Ground Floor |
| 15 | Wall Painting two coats with approved Distemper over a coat of Water Bound Wall cement Primer on Plastered Surfacein Ground Floor |
| 16 | Painting two coats with any approved colour of weather seal coat to out side surface of wall in Ground Floor |
| 17 | Painting two coats with any approved colour of weather seal coat over a coat of Water Bound Wall cement Primer to out side surface of wall in Ground Floor |
| 18 | Supplying, fitting & fixing of Vitrified plain series tiles in floors of size 600mmx 600mm of approved make confirming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (for New Work only ) |
| 19 | Supplying, fitting & fixing of Vitrified colour printed series tiles in dadoes, skirting and risers of steps of size 600mmx 600mm of approved make confirming to IS:13755 laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge |
| 20 | Supplying, fitting & fixing of CeramicTiles of minimum 16mm thick and above 0.10 sqm of approved make in floors over 25mm thick bed of cement mortar 1:4 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, taxes & royalties of all materials, labour with T&P complete in all respect.(Data for 10 Sqm ) |
| 21 | Supplying, fitting & fixing of Ceramic Tiles of minimum 16mm thick and above 0.10 sqm of approved make in dadoes, skirting and risers of nsteps laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge |
| 22 | Supplying, fitting & fixing of Granite Tiles of minimum 16mm thick and above 0.10 sqm of approved make in floors over 25mm thick bed of cement mortar 1:4 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, taxes & royalties of all materials, labour with T&P complete in all respect.(Data for 10 Sqm ) |
| 23 | Supplying, fitting & fixing of Chequered tiles in floors of approved make laid on 20 mm thick cement mortar (1:4) (1 cement : 4course sand) and filling joints with epoxy gouut of of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge |
| 24 | Supplying, fitting & fixing of Kodappa Tiles of 10 mm thick and Above 0.1 Sqm & Up to 0.40 Sqm.of approved make in floors over 25mm thick bed of cement mortar 1:1 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, taxes & royalties of all materials, labour with T&P complete in all respect.(Data for 10 Sqm ) |
| 25 | Supplying and Fixing of M.S. Grills, M.S.Doors, M.S. Gate etc including cost,conveyance of all materials and labour for fitting fixing etc.complete as per the instruction of Engineer-in-Charge |
| 26 | Painting two coats with approved Enamel Paint on wood work over a coat of Wood Primer in Ground Floor |
| 27 | Painting two coats with approved Enamel Paint on wood work and Steel work in Ground Floor |
| 28 | Supplying, fitting & fixing of Two track UPVC sliding windows with 6mm th. glass including cost of all fittings, fixyures all labour & T& P etc. complete. |
| 29 | Supply and fitting-fixing of Un-plasticised Poly Vinyl Choloride (UPVC) (FENESTA/NCL VEKA LTD). Casement Door-Window-60- Series duly manufactured using UPVC reinforced profiles of 60mm x 55mm x 2.5mm for outer frames, 102mm x 60mm x 2.25mm for casement Door Sash Profile and 74mm x 60mm x 2.5mm mullion profile capable of mounting single glazing system, system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 2.0mm prefabricated & welded through fusion welding teh door frame shall be fitted with 12mm thick WPC Board of Greenly make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners silicon rubber sealant, easy glazing/deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 368-14, EN-477-95 and other applicable codes and standards. |
| 30 | Supplying Fitting, fixing up fully glazed aluminium framed window (sliding type) made up aluminium section 9778 as window frame, section 4095, 4096 and 9777, 3994 as shutter frame with 5mm black glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of all materials, all taxes, labour, T&P excluding cost of glass etc. complete as per direction of the Engineer-in-charge |
| 31 | Supplying fitting fiixng of plain Glass 5mm thick including cost of all charges and as per the Direction of EIC. |
| 32 | Providing, fitting and fixing of Al door with anodized Al. door section of 9202 as vertical member, 9201 as top and 9200 as middle and bottom member with frame section No.9221 and tapered clip no. 4660 and the frame to be completed by means of jointing angle no. 1855 including all cost of labour, T&P, hire charges of drilling machine, labour charges , etc. complete as per direction of the Engineer-in-charge (with 3MM Thick ACP Board ) |
| 33 | Providing and fixing 65mmx1.25mm factory made single extruded WPC Door frame including cost of all charges and as per Direction of EIC. |
| 34 | Providing and fixing of 32mm thick flush door shutter confirming to IS : 2002 (Part-I) decorative type, core of 30mm thick BWR block board of approved make & pasted with 1.0mm thick sunmica on both sides of the flush door of approved design and quality etc. including the cost of all door fittings and fixures with cost of all labour, conveyance, loading, unloading, T & P etc. complete as per the direction of the Engineer-in-charge. |
| 35 | Providing and fixing 30mm thick factory made single extruded WPC Door Shutter including cost of all charges and as per Direction of EIC. |
| 36 | Supplying fitting & fixing of Leak proof treatment over roof with 3mm thick plastic bituminous felt of approved quality with cost of all materials, labour and T&P required for the work etc. complete as directed by the Engineer-in-charge. |
| 37 | 4cm thick grading concrete (1:2:4) on roof slab with 12mm and down graded size hard granite crusher broken chips for old work in Ground Floor |
| 38 | R.C.C. work of M-20 grade with 20mm and down grade black hard granite (crusher broken) stone chips including hoisting and laying |
| 39 | Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specifications in Ground Floor |
| 40 | Supplying and fixing Colour G.C.I sheeet on roof drilling hole in wind ties including fixing of ridges valley wind ties etc excluding cost o |
| 41 | Supplying and fixing big six traford A.C sheeet on roof including fixing ridges valley wind ties etc excluding cost of fittings per 1 sqm. |
| 42 | Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials labour T & P etc. as per direction of Engineer -In -charge. in Ground Floor |
| 43 | Wall Painting two coats with approved Plastic Emulsion Paint in Ground Floor |
| 44 | Providing fitting fixing of false ceiling with Aluminium anodised T section No.3215 with 2'0\\" center to center, L section No.1705 on 4 walls to be fixed by means of steel screw and P.V.C. plug and the Aluminium grid 2'0\\"x2'0\\" with Gypsum board suspended from ceiling including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge |
| 45 | Carriage of debrises by mechanical means with 5 km lead including all charges Please Enable Macros to View BoQ information |