| 1 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil. |
| 3 | Excavating in trenches, exc 1.5 m wide and n exc 1.5 m in depth and n.exc 3m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil. |
| 4 | M & L for cement concrete 1:4:8 using 40 mm graded crushed stone aggregates as in foundation, filling and mass concrete complete all as specified. |
| 5 | M & L for CRS TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete ball as specified and as directed. |
| 6 | All as per item No.5 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders. |
| 7 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter (rough finished). |
| 8 | M & L for RCC M-30 Design mix as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete. |
| 9 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions (rough finished). |
| 10 | M & L for RCC M-30 design mix for Columns, pillars, piers, posts and struts complete all as specified. |
| 11 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelvesincluding sup- ports, overhangs, etc. also splays between floors and beams, etc. (rough finished). |
| 12 | M & L for RCC M-30 design mix for Beams, cantilevers, bressummers, lintels over 1.5m span |
| 13 | Formwork (rough finished) to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping). |
| 14 | M & L for M-30 design mix for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like |
| 15 | M & L for Pre-cast cement concrete block masonry type C1 (1:3:6) (20 mm graded aggregate) set in 1:4 Cement mortar with solid blocks, exc. 10cm in width and setting in mortar, complete |
| 16 | S & F anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified. |
| 17 | M & L for Powder coated aluminium door shutters, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws, hinge type B-21 100mm long (3 no.) suitable handle (2 no.) (Glass / Wire mesh should be measured separately) complete all as specified. |
| 18 | M&L for sheet glass 4.8 mm thick ordinary quality and glazing with aluminium beeds in square exc 0.50 sqm in each pane complete all as specified and as directed. |
| 19 | M & L for 09mm thick prelaminated particle board, interiror grade, prelaminated on side with decorative choice Ipminationa and other side balancing white lamination fixed with screws to timber work or in aluminium door all as specified and directed. |
| 20 | S & F double action floor spring Hydraulically regulated made up of minimum 1.25mm thick aluminum alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty. |
| 21 | S & F Mortise lock vertical type, size 100 mm aluminium 4 levers. |
| 22 | S & F Door closer hydraulically regulated (aluminium extruded body), designation No: 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg. |
| 23 | M & L for 12 mm thick rendering on fair faces of brick work or concrete burfaces in cement sand mortar 1:6 as in internal surfaces of walls finished fair even and smooth without using extra cement. |
| 24 | M & L for 15 mm thick rendering on rough faces of brick work or concrete burfaces in cement sand mortar 1:4 as in external surfaces of wails finished fair even and smooth without using extra cement. |
| 25 | M & L for 5 mm-thick rendering on rough faces of brick work or concrete surfaces in cement sand mortar 1:4 as in RCC surfaces of ceiling finished fair even and smooth without using extra cement. |
| 26 | M & L for preparation of new plastered or unplastered surfaces and applying three coats of White Wash to exposed surfaces complete. |
| 27 | M & L for preparation of new plastered or unplastered surfaces and applying two coats of Oil Bound Distemper over primer to internal surfaces of walls. |
| 28 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 29 | S&F 2 mm PVC tiles/sheets, laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floor. |
| 30 | M & L for 75 mm thick cement concrete 1:3:6 using 40 mm graded stone aggregate as in sub base, floors, pavings, etc. |
| 31 | M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface. |
| 32 | M&L for100 mm thick plain cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate) as in, Path/flooring in alternate bay including use and waste of formwork, complete all as specified and as directed. |
| 33 | M & L for water proofing treatment by applying one coat of oil base bituminous primer @ 0.3 Kg / Sqm with brush / roller, laying of 3 mm thick APP based polymer modified membrane (mineral finish) reinforced non-woven polyester, weight not less than 3.50 Kg / Sqm and sealing all the over laps 150 mm in length side and 100 mm in width side of membranes laid with torch application complete all as specified and as directed. |
| 34 | M&L for screed bed or bedding layer of mortar 10 mm thick in cement mortar 1:4 including mixing only liquid water proofing compound as per manufacturers' instructions and finishing the surface fair and even. Note:- WPC will be measured & Paid separately. |
| 35 | Supply only liquid water proofing compound |
| 36 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) (Fe-410- W(Gde-E-250) quality-A) including distance pieces, cleats etc. |
| 37 | S & F in repairs 6mm thick plain, multicavity polycarbonate sheet (coloured) in roof covering, fixed with and including aluminum fillets at joints and aluminum angles at the end, fixed with self drilled screws and standard fittings, fixtures and accessories complete all as specified and directed. |
| 38 | M & L for preparation of new steel or iron surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified. Please Enable Macros to View BoQ information |
| 39 | M & L for preparation of new steel or iron surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified. Please Enable Macros to View BoQ information |