| Sl. No. | Item Description |
| 1 | Weeds clearance : Clearance of different types and nature of Water Hyacinth, Aquatic weeds, Taranies, Dalanies, Pitanies, repeated vegetation etc. from Beels/Tanks/Ponds/swampy and marshy areas dragging manually/ mechanically/ through machinery etc. with necessary ropes, bamboos, chains and other debries devices etc. making patches, cutting into pieces with the help of knifes/sickles/sews as necessary and depositing and stocking in the marginal areas of the beels/tanks/ponds/swampy and marshy areas in a regular form of bundhs or heaps within a lead of 100 m and lift up to 2.50 m as per direction of the deptt. etc complete (pushing out the patches or pieces of vegetations may also be made through the connecting channels with the river and burning the lifted vegetation after sunshine as and when applicable). i) Thin and floating water hyacinths and other aquatic weeds etc. |
| 2 | Weeds clearance : Clearance of different types and nature of Water Hyacinth, Aquatic weeds, Taranies, Dalanies, Pitanies, repeated vegetation etc. from Beels/Tanks/Ponds/swampy and marshy areas dragging manually/ mechanically/ through machinery etc. with necessary ropes, bamboos, chains and other debries devices etc. making patches, cutting into pieces with the help of knifes/sickles/sews as necessary and depositing and stocking in the marginal areas of the beels/tanks/ponds/swampy and marshy areas in a regular form of bundhs or heaps within a lead of 100 m and lift up to 2.50 m as per direction of the deptt. etc complete (pushing out the patches or pieces of vegetations may also be made through the connecting channels with the river and burning the lifted vegetation after sunshine as and when applicable). iv) Medium and floating Taranies,Dalanies, Pitanies and other marginal aquatic weeds etc. upto a depth of 50 cm to 80 cm |
| 3 | Weeds clearance : Clearance of different types and nature of Water Hyacinth, Aquatic weeds, Taranies, Dalanies, Pitanies, repeated vegetation etc. from Beels/Tanks/Ponds/swampy and marshy areas dragging manually/ mechanically/ through machinery etc. with necessary ropes, bamboos, chains and other debries devices etc. making patches, cutting into pieces with the help of knifes/sickles/sews as necessary and depositing and stocking in the marginal areas of the beels/tanks/ponds/swampy and marshy areas in a regular form of bundhs or heaps within a lead of 100 m and lift up to 2.50 m as per direction of the deptt. etc complete (pushing out the patches or pieces of vegetations may also be made through the connecting channels with the river and burning the lifted vegetation after sunshine as and when applicable). v) Heavy and floating Taranies,Dalanies, Pitanies and other marginal aquatic weeds etc. upto a depth of 80 cm to 120 cm |
| 4 | DE-SILTING & EXCAVATION:Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead from the beds of Beels/Tanks/ Ponds/ Swampy lands to the proper grade and slopes as required and utilizing the soil in construction of embankment or repairing of existing embankment on all sides, lifting in uniform layers not exceeding 20 cm thick (excluding compaction), clearing light jungles and trees up to 50 cm girth from the site of work, dug belling, profiling, ploughing or roughening or benching the seat, breaking clods up to 25 mm cube ramming, removing roots and vegetation, dressing to the designed section complete as directed. All kind of soil. The de-silted soil is utilised for construction peripheral bund, rearing tank bund Sediment Trap and Earthen Mound |
| 5 | TURFING:Furnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shownon the drawingor as directed by the Engineer including preparation of ground, fetching of sods and watering as per Technical Specification Clause 309. |
| 6 | Stone Pitching : Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302I) Stone/Boulder For Silt Trap |
| 7 | Filter Media : Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302 For Silt Trap |
| 8 | Hume pipe laying at Bund : Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106..........NP3 HP...600 mm dia |
| 9 | EARTHWORK IN EXCAVATION: Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material... (I) Ordinary soil.Upto 15.0m Depth For HP Culvert |
| 10 | PLAIN/ REINFORCEMENT CONCRETE: Plain Cement Concrete M15 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109For HP Culvert |
| 11 | BEDDING FOR PIPE: Bedding for Pipe : Type B (First Class) Bedding..Laying (First Class) bedding on well compacted sand, moorum or approved granular material as per Clause 1105 (ii)Granular material For HP Culvert |
| 12 | BRICK MASONRY WORK: Head Wall: Foundation :-Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 600,1202&1203 i. Brick masonry in 1:3 cement mortarFor HP Culvert |
| 13 | BRICK MASONRY WORK: Head Wall: Substructure :-Brick masonry work in cement mortar in Substructure complete excluding pointing and plastering as per drawing and technical specifications Clauses 600,1202&1203 i. Brick masonry in 1:3 cement mortarFor HP Culvert |
| 14 | PLASTERING WORK: Plastering with Cement Mortar (1:4), 15 mm thick on brickwork in substructure as per technical specificationFor HP Culvert |
| 15 | EARTH CAUSHIONING WORK: Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.(i) Private Land (for Earth Work in cushioning)For HP Culvert |
| 16 | PROTECTION WORK: Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3For HP Culvert |
| 17 | PROTECTION WORK: Providing and laying filter material underneath pitching in slopesFor HP Culvert |
| 18 | HP CULVERT: Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.. 1 x 1000 mm dia |
| 19 | HP CULVERT: Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.. 2 x 1000 mm dia |
| 20 | SITE CLEARANCE IN APPROACH ROAD : Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. By Manual Means-, In area of non thorny jungle |
| 21 | CONSTRUCTION OF EMBANKMENT WITH MATERIAL OBTAINED FROM BORROW PITS: Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5(ii)Govt. LandFOR APPROACH ROAD |
| 22 | CONSTRUCTION OF SUBGRADE AND EARTHEN SHOULDERS: Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.(ii)Govt. LandFOR APPROACH ROAD |
| 23 | GSB WORK: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.By Mix in Place Method(ii)For Grading II MaterialFOR APPROACH ROAD |
| 24 | WBM WORK: Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.(A) By Manual Means.. Using stone screening Type-B 11.2 mm for Gr.IIIFOR APPROACH ROAD |
| 25 | INTER LOCKING CONCRETE BLOCK PAVEMENT: Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage. Including Edge block/ Edge restraintsFOR APPROACH ROAD |
| 26 | SITE DEVELOPMENT FOR PARKING AREA: Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete.For Community Hall & Fish Landing |
| 27 | SITE DEVELOPMENT FOR PARKING AREA (GSB): Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25For Community Hall & Fish Landing |
| 28 | SITE DEVELOPMENT FOR PARKING AREA (WBM: GR - III): Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .For Community Hall & Fish Landing |
| 29 | SITE DEVELOPMENT FOR PARKING AREA (ICBP): Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. For Community Hall & Fish Landing |
| 30 | EARTHWORK IN EXCAVATION: Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. For Community Hall, Fish Landing, Water Tank & Fencing Gate |
| 31 | ANTI-TERMITE TREATMENT:- Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration For Community Hall |
| 32 | ANTI-TERMITE TREATMENT :- Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration, For Fish Landing |
| 33 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos emulsifiable concentrate of 20% litre. For Community Hall, Fish Landing, |
| 34 | EARTHWORK IN FILLING : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. For Community Hall |
| 35 | EARTHWORK IN PLINTH FILLING : Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. For Community Hall, Fish Landing, |
| 36 | Brick Soling Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 . For Community Hall |
| 37 | PLAIN CEMENT CONCRETE (CAST -IN- SITU): Plain cement concrete1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources). For Community Hall |
| 38 | PLAIN CEMENT CONCRETE (CAST -IN- SITU): Plain cement concrete Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) For Fish Landing & Gate |
| 39 | PLAIN CEMENT CONCRETE (CAST -IN- SITU): Plain cement concrete Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) For septic Tank |
| 40 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. For Community Hall, Fish Landing, |
| 41 | SHUTTERING: Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns...Footing. For Community Hall, Fish Landing, Water Tank & Fencing Gate |
| 42 | SHUTTERING: Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers . For Community Hall, Fish Landing, Water Tank & Fencing Gate |
| 43 | SHUTTERING: Centering and shuttering including strutting, propping etc. and removal of form work for : Columns, piers, abutments, pillars, posts and struts. For Community Hall, Fish Landing, Water Tank & Fencing Gate |
| 44 | STEEL REINFORCEMENT: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.. For Community Hall, Fish Landing, Water Tank & Fencing Gate |
| 45 | STEEL REINFORCEMENT: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level.. Mild steel and Medium Tensile steel bars . For Septic Tank |
| 46 | REINFORCED CEMENT CONCRETE (CAST -IN- SITU): Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources). For Community Hall, Fish Landing, Water Tank & Fencing Gate |
| 47 | REINFORCED CEMENT CONCRETE (CAST -IN- SITU): Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). For Fish Landing, Water Tank & Fencing Gate |
| 48 | REINFORCED CEMENT CONCRETE (CAST -IN- SITU): Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) . For Community Hall, Fish Landing |
| 49 | BRICK WORK : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand). For Community Hall |
| 50 | EXPOSED BRICK WALL :- Brick work with common burnt clay selected F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand). From ground level upto plinth level. For Fish Landing, |
| 51 | DAMP PROOF COURSE (DPC): Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) . For Community Hall, Fish Landing |
| 52 | BRICK WORK : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand). For Community Hall, |
| 53 | BRICK WORK : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level…..Cement mortar 1:3 (1 cement :3 coarse sand). For Fish Landing, |
| 54 | CEMENT PLASTER:: CEMENT PLASTER (IN COARSE SAND) 12 mm Cement Plaster of mix: 1:4 (1 cement: 4 coarse sand) For Fish Landing, Gate |
| 55 | CEMENT PLASTER:: CEMENT PLASTER (IN COARSE SAND) 15 mm Cement Plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand). For Community Hall, Fish Landing |
| 56 | CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) . For Community Hall, |
| 57 | PAINTING: Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:.. - One or more coats on old work. . For Fish Landing, Gate |
| 58 | PAINTING: Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm . For Fish Landing, |
| 59 | TILES: Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colors and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero-chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm . Floor Tiles. For Community Hall, |
| 60 | TILES: Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete..WALL TILES. For Community Hall, Fish Landing |
| 61 | TILES: Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of Size of Tile 600 x 600 mm sqm. For Community Hall, Fish Landing |
| 62 | ALUMINIUM WINDOW Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) . For Community Hall, |
| 63 | DOOR FRAME : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood. For Community Hall, |
| 64 | Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : 100x60x2.50 mm. For Community Hall, |
| 65 | FLUSH DOOR : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. For Community Hall, |
| 66 | UPVC Window :- Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Three track three panels sliding window with fly proof S.Swire mesh (Two nos. glazed & one no. wire mesh panels)made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). For Fish Landing, |
| 67 | DOOR FITTINGS : Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete. 200x10 mm For Community Hall, |
| 68 | DOOR FITTINGS Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm . For Community Hall, |
| 69 | DOOR FITTINGS Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm . For Community Hall, |
| 70 | PVC DOOR Providing and fixing factory-made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless-steel screws, joints mitered and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer in- chargeExtruded section profile size 42x50 mm . For Community Hall, Fish Landing |
| 71 | PVC DOOR SHUTTER Providing and fixing to existing door frames. 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter stles by means of plastic/ galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. For Community Hall, Fish Landing |
| 72 | PAINTING WORK Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. For Community Hall, Fish Landing |
| 73 | PAINTING WORK Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface : Water thinnable cement primer. For Community Hall |
| 74 | PAINTING WORK Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats . For Community Hall |
| 75 | PAINTING WORK Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm . For Community Hall |
| 76 | ROOFING SHEET : Providing & fixing at all heights, levels and locations Mill finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). 0.56 mm, Aluminium troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. For Community Hall |
| 77 | Roofing sheet :- Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). 0.56 mm, Aluminium troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. For Fish Landing |
| 78 | RIDGE SHEET : Providing and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)] For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : Precoated/mill finish aluminium Ridges plain (500- 600mm) . For Community Hall, Fish Landing |
| 79 | FALSE CEILING: Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board celling conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) sqm 1145.95. For Community Hall |
| 80 | RAILING Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works . For Community Hall |
| 81 | TRUSS Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes . For Community Hall |
| 82 | Steel truss :- Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes . For Fish Landing & Water Tank |
| 83 | Providing and fixing bolts including nuts and washers complete.. For Fish Landing & Water Tank |
| 84 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. .Angle Section ISA 50x50x3. For Water Tank |
| 85 | GRILL :- Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with Rawl plugs screws etc. For Community Hall |
| 86 | EPOXY STEEL PAINT :- Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work. For Community Hall & Fish Landing |
| 87 | PLINTH PROTECTION: Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. For Community Hall |
| 88 | ROLLING SHUTTERS : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.... 80x1.20 mm M.S. laths with 1.20 mm thick top cover. For Fish Landing |
| 89 | Providing and fixing ball bearing for rolling shutters. For Fish Landing |
| 90 | Ramp Railing :- Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.G.I. pipes 50mm dia. For Fish Landing |
| 91 | Drain Cover Slab :-Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge. For Fish Landing |
| 92 | CEMENT PLASTER (IN FINE SAND): 15 mm cement plaster on the rough side of single or half brick wall of mix .1:4 (1 cement: 4 fine sand). For Septic tank |
| 93 | MANHOLE COVER : Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality. Circular shape 450 mm internal diameter. For Septic tank |
| 94 | WATER PROOFING : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. For Septic tank |
| 95 | COLLAPSABLE GATE : Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. For Community Hall |
| 96 | PCC :- Plain cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). For Chainlink fench |
| 97 | CHAINLINK FENCH : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm. For Chainlink fench |
| 98 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10cm length and drilling holes upto 10 mm dia. etc. complete. For Fencing. |
| 99 | STEEL GATE : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer…......... M.S. tube. For Chainlink fench Gate |
| 100 | STONE TILE WORK : Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade...8mm thick (mirror polished and machine cut edge)..Granite stone of any colour and shade. For Entrance Gate |
| 101 | WATER SUPPLY PIPES :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold-water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall20 mm nominal dia Pipes.. For Community Hall |
| 102 | WATER SUPPLY PIPES :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold-water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - 25 mm nominal dia Pipes. For Community Hall |
| 103 | WATER SUPPLY PIPES :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold-water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes |
| 104 | WATER SUPPLY PIPES :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes. For Community Hall |
| 105 | WATER SUPPLY PIPES :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes |
| 106 | WATER SUPPLY PIPES :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.. External work. 25 mm nominal dia Pipes. For Fish Landing |
| 107 | WATER SUPPLY PIPES :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with onestep CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.... 15 mm nominal dia Pipes For Fish Landing |
| 108 | WATER SUPPLY FITTINGS :- Providing and fixing PTMT bib cock of approved quality and colour… 15mm nominal bore, 86 mm long, weighing not less than 88 gms. For Fish Landing |
| 109 | WATER SUPPLY FITTINGS :- Providing and fixing PTMT pillar cock of approved quality and colour..15 mm nominal bore, 107 mm long, weighing not lessthan 110 gms. For Fish Landing |
| 110 | WATER SUPPLY FITTINGS :- Reducer for 22 mm X 15 mm outer Dia SS pipe of grade 316L as per IS 6911:2017 and conforming to EN-10312 standard. For Fish Landing |
| 111 | WATER SUPPLY FITTINGS :- Elbow 90° for 15 mm outer dia SS pipe of grade 316L as per IS 6911:2017 and conforming to EN-10312 standard. For Fish Landing |
| 112 | WATER SUPPLY FITTINGS :- Equal Tee for 15 mm outer dia SS pipe of grade 316L as per IS 6911:2017 and conforming to EN-10312 standard. For Fish Landing |
| 113 | WATER SUPPLY FITTINGS :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 100 mm nominal dia Pipes For Community Hall |
| 114 | WATER SUPPLY FITTINGS :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.80 mm nominal dia Pipes For Community Hall |
| 115 | SANITARY FITTINGS : TRAPS ; Bottle trap 31mm single piece moulded with height of270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms For Community Hall & Fish Landing |
| 116 | SANITARY FITTINGS : Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. Flexible pipe. 32 mm dia For Community Hall & Fish Landing |
| 117 | SANITARY FITTINGS : BIB COCK Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore For Community Hall |
| 118 | SANITARY FITTINGS : STOP COCK Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore For Community Hall |
| 119 | SANITARY FITTINGS : ANGLE VALVE Providing and fixing C.P. brass angle valve for basin mixer and geyserpoints of approved quality conforming to IS:893115mm nominal bore For Community Hall |
| 120 | SANITARY FITTINGS : PILLER COCK Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mmwith a pair of 15 mm C.P. brass pillar taps For Community Hall |
| 121 | SANITARY FITTINGS : WC PAN Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid For Community Hall |
| 122 | SANITARY FITTINGS : URINAL BASIN Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern For Community Hall |
| 123 | SANITARY FITTINGS : Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests For Fish Landing |
| 124 | SANITARY FITTINGS : Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : :.....100 mm diameter For Fish Landing |
| 125 | SANITARY FITTINGS : Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standarddesign : :.....100 mm diameter S.W. pipe For Fish Landing |
| 126 | SANITARY FITTINGS : Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock. For Fish Landing |
| 127 | SANITARY FITTINGS : Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes andfittings. For Fish Landing |
| 128 | SANITARY FITTINGS : Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms For Fish Landing |
| 129 | SANITARY FITTINGS : Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.. For Fish Landing |
| 130 | SANITARY FITTINGS : Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. For Fish Landing |
| 131 | SANITARY FITTINGS : Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms. For Fish Landing |
| 132 | SANITARY FITTINGS : Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36mm height of approved quality and colour, weighing not less than300 gms… For Fish Landing |
| 133 | SANITARY FITTINGS : Providing and fixing PTMT urinal cock of approved quality and colour. 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48gms. For Fish Landing |
| 134 | SANITARY FITTINGS : Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. For Fish Landing |
| 135 | SANITARY FITTINGS : Providing and fixing 100 mm sand cast Iron grating for gully trap. For Fish Landing |
| 136 | SANITARY FITTINGS : Providing and fixing soil, waste and vent pipes :100 mm dia…Sand cast iron S&S pipe as per IS: 1729. |
| 137 | SANITARY FITTINGS : Providing and fixing plain bend of required degree… 100 mm dia...Sand cast iron S&S as per IS - 1729. For Fish Landing |
| 138 | SANITARY FITTINGS : Providing and fixing collar :… 100 mm dia...Sand cast iron S&S as per IS - 1729. For Fish Landing |
| 139 | MIRROR Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm. For Community Hall & Fish Landing |
| 140 | TOWEL RAIL Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. For Community Hall |
| 141 | SANITARY FITTINGS : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore. For Community Hall |
| 142 | SANITARY FITTINGS : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore. For Community Hall |
| 143 | SANITARY FITTINGS : Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : For 100 mm dia pipe . |
| 144 | SANITARY FITTINGS : Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :100x100x100x100 mm Sand cast iron S&S as per IS - 1729 . |
| 145 | WATER TANK : Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. For Community Hall |
| 146 | ELECTRICAL PART : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C. For Community Hall & Fish Landing |
| 147 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire . For Community Hall |
| 148 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. For Community Hall |
| 149 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. For Community Hall |
| 150 | Supplying and fixing PVC batten / angle holder including connections etc as required. For Fish Landing |
| 151 | CEILING FANSupply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. For Community Hall & Fish Landing |
| 152 | Supplying and fixing modular type 6/6 Amp one way switch on existing modular plate and switch box including connections but excluding modular plate etc. as required. For Fish Landing |
| 153 | Supply of exhust fan 200 mm sweep. For Community Hall |
| 154 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep . For Community Hall |
| 155 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch . For Community Hall . |
| 156 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch. For Community Hall |
| 157 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet. For Community Hall |
| 158 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet. For Community Hall |
| 159 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. For Community Hall |
| 160 | Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 module. For Community Hall |
| 161 | Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm). For Community Hall |
| 162 | Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required. 12 Module (200mmX150mm). For Community Hall |
| 163 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 module . For Community Hall |
| 164 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 8 Module. For Community Hall |
| 165 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 12 Module. For Community Hall |
| 166 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. For Community Hall |
| 167 | Supplying and fixing brass batten/ angle holder including connection etc. as required. For Community Hall |
| 168 | Supplying and fixing two-module stepped type electronic fan regulator on existing modular plate and switch box including connections but excluding modular plate etc. as required. For Fish Landing |
| 169 | Installation of Exhaust Fan in the existing opening including making good the damage, connection, Testing, commissioning etc required. Upto 450mm sweep. For Fish Landing |
| 170 | Supplying and fixing suitable size GI Box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 amps & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc.. as required . For Fish Landing |
| 171 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including holes in cubicle panel, making connections, etc. as required. 32 A TP&N |
| 172 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 125 A TP&N .For Fish Landing |
| 173 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 16 way, Double door . For Community Hall |
| 174 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. For Community Hall |
| 175 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A. For Community Hall |
| 176 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. For Community Hall |
| 177 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with Gl thimble etc. as required. For Community Hall |
| 178 | LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K/4000°K /5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete. in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 Im/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 m 36 watt. For Community Hall |
| 179 | Supplying of LED Recessed/ surface Down lighter (Round/ square/Rectangular) COB Type of following body material and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.20.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (fiicker should be below 5%), life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K/5700°K/6000K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector. 18 watt. For Community Hall |
| 180 | Supply and fitting fixing of 5 KWA solar panel hybried system with 2HP motor pump. For Community Hall |
| 181 | Demarcation PillarRCC Guard Post:Supplying, fitting and fixing RCC guard post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade (nominal mix 1:2:4 with broken stone aggregate up to 20mmsize) of cement concrete and required reinforcement tied in position with an nealed black wire including centering, moulding the top, curing including painting concrete surfaces in 3cm stripsup to0.75m from the to alternately in black and white and having 2 nos. reflective band of desired shade etc complete as per design and as directed.A) 30cmdia.RCCguardpostwithreinforcementof6nos.12mmdiaTMTmain steel bars and 6mm TMT/ MS stirrups at 15cm c/c. |
| 182 | Pen Culture:Construction of Pen Culture with Bamboo (1st Class) 85 mm - 100 mm dia, 4.5 m - 5.5 m long, vertically placed at 2.00 m centre to centre driven 1.50 m below ground/bed level and 2.50 m above ground/bed level tied with Jati or Bethua bamboo 50mm to 100 mm dia and 6m long above groung level horizontally in two rows at 2.00 m apart, Fencing with split bamboo kamis in horizontal direction at 300 mm c/c and vertical direction at 800 mm c/c having tied with coconut fiber two poly twisted rope etc. manually with provision of hired country boat (2 nos.), fitting and fixing of PEN culture Net 115 GSM HDPE mono shade, 45 ply Nylon, 210D, 24 mm mesh size net with boarder rope of 10 mm dia Polypropylene and tie rope in every 2 meter intervals conforming to technical requirement of Textiles - Twisted Nylon Fish-Net Twines as per IS 4401-2006, complete as per drawings and technical specifications as directed by Engineer in-charge. |
| 183 | Katal FishingErection of Fish Agregating Device as Katal / Jeng Fishing circular structure at Beel/ Wetland covering 0.25 Ha water area with Bamboo Bholuka or Barua 55mm to 100mm dia and 6m long vertical member placed at 3.00 m centre to centre, Jati or Bethua Bamboo 50mm to 100 mm dia and 6m long tie horizontally with vertical members (Kamis)- one row and Inclined members (strut) to support each vertical member driven 2.00 m below the ground/bed level and 3.50 m to 4.00 m above the ground/bed level tied with coconut fiber two ply twisted rope etc. manually with provision of hired country boat complete as per drawings and technical specifications as directed by Engineer in-charge. |
| 184 | Bamboo Partition structure Construction of Bamboo Screening Structure by placing and arranging of whole Bamboo in barricade type with Bamboo Bholuka or Barua 55mm to 100mm dia and 6m minimum in length, vertically placed two rows in staggered manner at 2.50 m centre to centre, driven 2.00 m below ground/bed level and 4.00 m above ground/bed level tied with Jati or Bethua bamboo 50mm to 100 mm dia and 6m long above groung level horizontally in two rows at convenient level having tied with coconut fiber two poly twisted rope etc. manually with provision of hired country boat (2 nos.), fitting and fixing of 72 ply HDPE 30mm kk mesh size net with boarder rope of 32mm dia TUF PP IR 3 strand 220 mtr : 101 kg and tie rope in every 2 meter intervals conforming to technical requirement of Textiles - Twisted Nylon Fish-Net Twines as per IS 4401-2006, complete as per drawings and technical specifications as directed by Engineer in-charge. |
| 185 | SOLAR LAMP:Supply, Installation, Testing and commissioning of a Complete solar street-lighting system, including a 160Wp crystalline silicon solar photovoltaic module supplied with a compatible module mounting structure, clamps, fasteners, and UV-resistant cable tails, with test certification conforming to IEC 61215 (Edition II)/IS 14286 and IEC 61730 from a NABL or IECQ accredited laboratory. The system shall incroporate a Lithium Iron Phosphate (LiFePO4) battery of 12.8V nominal voltage and 42 Ah capacity, equipped with an integrated Battery Management System (BMS) providing protections against over/under-voltage, over-current, short-circuit, over-temperature, and ensuring cell balancing, duly certified to IEC 62133-2011 or the latest BIS standard by a BIS-recognized lab or MNRE-accredited test centre. The MPPT charge controller, integrated with the luminaire and battery, shall operate at 12.8 V noinal, have a maximum current rating of 6A/12 A/14 A as required and provide automatic dusk-to-dawn operation, LiFEPO4 charging profiles, and full electronic protection. The LED street-light luminaire shall be rated at 30W(+5%), with high-effciency optics, a driver compatible with the MPPT output, and ingress protection of IP66 or higher, complying with relevent BIS standards, The system shall be mounted on a 6m long 2.2mm thick tubular hot-dip galvanized GI pole conforming to IS 1161 and IS 4736 complete with a single-arm bracket, MMS, and light arm to hold the luminaire and PV module, along with all necessary clamps and fasteners. The work shall include complte erection on a prepared foundation, all wiring and interconnection, functional testing (dusk-to-dawn operation) in the presence of the Engineer-in-Charge, and submission of as-built documentation. The contractor shall also provide a Comprehensive Maintenance Contract (CMC) for a period of five years from the date of commissioning covering preventive and breakdown maintenance, replacement of defective parts, and maintenance of illuinataion levels as specified. |
| 186 | INFORMATION BOARD:Providing and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 187 | Boring::-- Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level...All types of soil : 300 mm diaFOR BORE WELL |
| 188 | Casing Pipe:: Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge........... 100 mm nominal size dia FOR BORE WELL |
| 189 | Screen (RMS) pipes:...Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.....100 mm nominal size dia FOR BORE WELL |
| 190 | MS Pipe::---Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge......150 mm nominal size dia having minimum wall thickness 5.00 mmFOR BORE WELL |
| 191 | Development of tube well: Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc.,all as per requirement and direction of Engineer-in-charge.FOR BORE WELL |
| 192 | MS cap: Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:…...........150 mm diaFOR BORE WELL |
| 193 | Lowering of column pipe: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge..........40 mm nominal dia Pipes FOR BORE WELL |
| 194 | Gravel packing in tubewell:….Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.FOR BORE WELL |
| 195 | EMP:Implementation & Monitoring of Environmental Management Plan (EMP) as the provisions in the Bidding Document Vol-2, for which the estimated cost is Rs.1,15,000/ = Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail