| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. ALL kind of soil |
| 2 | Oridinary rock |
| 3 | Dumping stone including cost of stones.in Horizontal on level |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished 40 mm thick with 20 mm nominal size stone aggregate |
| 6 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level ::1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.Q.V.I(6+7+8) @ 110kgs/cum |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns etc. for mass concrete. |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form forLintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 13 | Columns, pillars, piers, abutments, posts and struts. |
| 14 | Suspended floors, roofs, landings, balconies and access platforms. |
| 15 | Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 16 | Providing & fixing upto floor five level precast cement concrete solid blocks including hoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost of required centring, shuttering and curing complete 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20 mm nominal size) |
| 17 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class Kail wood |
| 18 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.Second class Kail wood |
| 19 | Providng & fixing of Float glass panes 4 mm thick glass pane (weight not less than 10kg/sqm)., with wooden fillets wherever required complete |
| 20 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)Second class teak wood 30 mm thick shutters |
| 21 | 15mm Cement plaster on the rough side of single or half brick wall of mix:1 : 4 ( 1 cement : 4 fine sand) |
| 22 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) sqm |
| 23 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.Q.V.I (17B+18) |
| 24 | Finishing walls with textured exterior paint of required shade : 13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqmQ.V.I (17A) |
| 25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primerQ.V.I (19) |
| 26 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 27 | Providing & fixing 12mm thick ready made wooden flooring incl 1mm thick thermocol incl placeing in position complete job.(AC-4). |
| 28 | Providing & Fixing Fan Box |
| 29 | Providing & Fixing Conceal Box |
| 30 | Wiring for light point 6amp socket/exhaust fan point / call bell point /with 1.5 Sq.mm PVC FR insulated copper conductor single core in surface/recessed medium class PVC conduit, suitable size MS box and earthing the point with 0.75 Sq.mm. FR PVC insulated copper conductor single core cable as required. |
| 31 | Wiring for 16amp socket outlet with 2.5mm FR PVC insulated copper conductor cable in existing recessed PVC conduit , including sheet as required. |
| 32 | Supplying and fixing of 25mm PVC conduit capping along with accessories in surface/recessed including cutting the wall and making good the same in case of recessed conduit as required. |
| 33 | Supply and fixing of combined 3 pin 240 volt 10amp socket outlet with safety shutter and 10amp 240 volt single pole mounted in recessed including M.S box complete as required |
| 34 | Supply and fixing of combined 3 pin 240 volt 10amp socket outlet with safety shutter and 20amp 240 volt single pole mounted in recessed including M.S box complete as required |
| 35 | Supply and fixing of following single pole and neutral sheet steel MCB distribution board 240 volt on surface recess complete with tinned busbar neutral link earth bar, tin bar, detachable glaud plates, double door interconnected including pointing etc as required 16 way double door SPN. |
| 36 | Supply and fixing of the following light fixtures of 2'-0\\" x 2'-0\\" panels including all accessories like electronic ballasts coms etc, complete as required concealed/Tube lightning 20 watt 3000k, round LED Luminaries as per Philips |
| 37 | Supply and fixing of the following light fixtures including all accessories like electronic ballasts coms etc, complete as required concealed/Tube lightning 20 watt 3000k, round LED Luminaries as per Philips |
| 38 | Supply and fixing of miniature circuit breaker of following poles in the existing MCB DB completed with connections testing andcommissioning etc, as required. A) Single pole 6/10/20 Amp |
| 39 | B) Double pole 40 Amp |
| 40 | C) Double pole 63 Amp |
| 41 | 3 modular plate |
| 42 | 6 modular plate |
| 43 | 8 modular plate |
| 44 | 12 modular plate |
| 45 | Ceiling fan regulator |
| 46 | Providing & fixing of ceiling fan complete job |
| 47 | Providng & fixing of Changeover of required specificatioon comnplete job |
| 48 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately): For fixed portion. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 49 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade 1 Type II in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Prelaminated particle board with decorative lamination on both sides |
| 50 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 51 | CARRIAGE OF MATERIALS By Mechanical Transport including loading, unloading and stackingCement & Steel (avg. lead 10km) |
| 52 | Sand & Stone agg (20mm n/s) (avg. lead 10km) |
| 53 | Soling stone (avg. lead 10km) Please Enable Macros to View BoQ information |