| 1 | Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 2 | M&L for rendering 15mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces, finished fair and even, complete all as specified and directed. |
| 3 | M&L for rendering 15mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces, finished fair and even using water proofing compound @3% by weight of 50 kg cement as per manufacturer instructions, complete all as specified and directed. |
| 4 | M&L for rendering 10 mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished fair & even, complete all as specified and directed. |
| 5 | M & L for applying three coats of white wash on ceiling incl preparation of new plastered surfaces, complete all as specified and directed. |
| 6 | M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion, white or tinted over 1 mm thick wall care putty, complete all as specified and directed. |
| 7 | M&L for preparation of new surfaces of wall any type applying two coat of exterior emulsion paint over 1 mm thick wall care putty, complete all as specified and directed. |
| 8 | M&L for complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, applying two coats of distemper, oil emulsion white or tinted over and including 1 mm thick wall care putty, complete all as specified and directed. |
| 9 | M&L for preparation of old surfaces of ceiling and applying two coats of whitewash on ceiling surfaces, complete all as specified and directed. |
| 10 | M&L for complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, and applying two coat of exterior emulsion paint over 1 mm thick putty wall care, complete all as specified and directed. |
| 11 | Dismantling brick/ concret tiles any size etc incl existing roof treatment of any thickness, complete all as specified and directed. |
| 12 | Demolition of Mud/mud puska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof), complete all as specified and directed. |
| 13 | Removing building materials etc. to a distance of 1000 m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination, complete all as specified and directed. |
| 14 | M&L for complete removal of existing roof treatment (tar felt of any thickness) at any height of the building and cleaning the roof thoroughly with wire brushes and brooms to remove all loose particles and re removing the debris out side MoD land, complete all as specified and directed. |
| 15 | M&L for 25 mm thick avg PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in roof padding, benching existing roof slab to slope as per existing or as directed including finished surface even and fair, complete all as specified and directed. |
| 16 | M&L for PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) as in coping, coving and levelling and filling etc as required finishing the surface fair & even, complete all as specified and directed. |
| 17 | M&L for rendering 15 mm thick in cement mortar (1:3) cover concrete surfaces of roof, mixed with @ 200ml liquid water proofing compound by 50Kg weight of cement (1 bag) as per manufacturerrs instruction inclduing finishing surfaces even and fair, complete all as specified and directed. (WPC shall be measured and paid separately). (Note: WPC will be measured and paid separately). |
| 18 | Cleaning the roof surfcae from dust /dirt and any other foreign materials and applying a coat of bituminius primer @ 0.40 liters per square meter uniformity after the surfaces fully dried, complete all as specified and directed. |
| 19 | M&L for applying a coat of hot blown bitumen of grade 85/25 conforming to IS 702 over primed surface of roof slab @ 1.20 Kg/Sqm, complete all as specified and directed. |
| 20 | M & L for APP based polymeric water proofing membrane minimum weight 3 Kg/ Sqm and minimum 3mm thick reinforced with polyster non wove fabric (Weight not less than 150gms/Sqm or as per IS), laid over hot bitumen surface by torched application with the strict supervision of manufacturers technical supervisor. Membrane shall be laid with 100mm side/end lap on prepared surface as per manufacturer instruction work shall be carried out strictly with the technical tradesmen and supervision of technical staff of manufacturer, complete all as specified and directed. |
| 21 | Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and loped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 oarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, ncludingrubbing and polishing of the surface upto 3 cuts, complete all as specified and directed, including providing skirting in the same manner. |
| 22 | Supply only Integral waterproofing compound, complete all as specified and directed. |
| 23 | Supply only liquid water proofing compound, complete all as specified and directed. |
| 24 | M&L for cutting out cracks to V section in existing roofs or terrace, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand (1:1) (by weight), complete all as specified and directed. |
| 25 | S&F for Rotational moulded polythene water storage tanks tripple layer hoisted and fixed in position 1000ltrs capacity includin GI union, checked nut and 20 mm PTMT float Valve, complete all as specified and directed including Dismantling of old PVC tank and removing to store. |
| 26 | S&F for Rotational moulded polythene water storage tanks tripple layer hoisted and fixed in position 500ltrs capacity including GI union, checked nut and 20 mm PTMT float Valve, complete all as specified and directed including Dismantling of old PVC tank and removing to store. |
| 27 | S&F in repair 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed, complete all as specified and directed. |
| 28 | Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames), complete all as specified and directed. |
| 29 | Taking down chowkats with shutters exceeding 1.5 Sqm but n exc 4.00 Sqm each (without taking off shutters from the frames), complete all as specified and directed. |
| 30 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length, complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 31 | S&F for Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as and direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately). |
| 32 | S&F 125x60mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges lock strike plate etc including prepration of new steel surface and applying two coats of red oxide primer, complete all as specified and fixed. |
| 33 | S&F for 105x60mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges lock strike plate etc including prepration of new steel surface and applying two coats of red oxide primer, complete all as specified and fixed. |
| 34 | M&L for PCC 1:3:6 type C-0 using 12.5 mm graded crushed stone aggregate as in filling of pressed steel frame, complete all as specified and directed. |
| 35 | S&F for 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed. |
| 36 | 2nd class hard wood 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified and directed. |
| 37 | M&L for preparation of new wooden surface of any description over 10 cm in width or girth and applying two coat of synthetic enamel paint over a coat of pink primer, complete all as specified and directed. |
| 38 | S&F for Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc, complete all as specified and directed. |
| 39 | S&F for 250mm long SS sliding door bolt with hasp staple, bolt type, complete all as specified and directed. |
| 40 | S&F for 150mm SS handles, cast type, complete all as specified and directed. |
| 41 | S&F for 200mm SS barrel tower bolts of extruded section and fixed, complete all as specified and directed. |
| 42 | S&F for 100 mm long SS butt hinges, medium weight, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 43 | S&F for 100 mm long SS butt hinges, medium weight, complete all as specified and directed. Please Enable Macros to View BoQ information |