| 1 | Replacement of existing burnt Change over switch with new one 63 A four pole on load change over switch in Sheet Steel Enclosure suitable for operation on 415 Volt, 50 Hz AC-23A Duty i/c drilling hole on the board, making connection, earthing the body i/c interconnection etc. as reqd. (Make: M/s HPL / Havells / HH Elecm make) |
| 2 | Providing and Fixing of following sizes Stranded Aluminum Conductor, XLPE Insulated, PVC Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 i/c laying on the surface/ duct/ in ground etc. (Make: ISI Mark) |
| 3 | 4x16 sqmm |
| 4 | Providing and Fixing of following capacity Rewireable Kit-kat (Porcelain Fuse carrier & Base) suitable for 415 volt 50hz AC supply including fixing on the existing board making connection testing etc as required at site. |
| 5 | 100 Amps |
| 6 | S/ Fixing meter board of bakelite sheet of 6.00 mm thick on the existing angle iron farme complet as required at site . |
| 7 | Removal of existing light fittings, fans, faulty main switches, changeover switches, cables, MCBDB and other related items including disconnection from power supply in the area to be vacated, as required at site . |
| 8 | Replacement of light fitting with 4 feet, 20 watt LED Tube light with integral LED driver, on the surface of wall / ceiling i/c making connection complete as required at site.( M/s Havells make REGAL BATTEN model REGALBATTEN T8 UPTO1X22WDSBSWH or equivalent SS make. |
| 9 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 10 | 4 X 16 sq. mm (28mm) |
| 11 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 12 | 2 X 1.5 sq.mm+ 1X1.5 sq.mm earth wire |
| 13 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 14 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 15 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required |
| 16 | 5/6 amps switch |
| 17 | 15/16 A switch |
| 18 | 3 pin 5/6 A socket outlet |
| 19 | 6 pin 15/16 A socket outlet |
| 20 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 21 | Upto 35 sq. mm (clamped with 1mm thick saddle) Please Enable Macros to View BoQ information |