| 1 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.In ground floor |
| 2 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 mIn ground floor including roof.(a) upto 150 mm. thick |
| 3 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel barsIn ground floor including roof. |
| 4 | (A) Stitching crack in brick wall by carefully cutting out face brick 125 mm. deep into the wall, cleaning the gap and filling up the same with precast cement concrete block carefully set in cement mortar (1:3) including mending good damages and finishing the surface to match with adjacent areas complete as per direction.(ii) With reinforced cement concrete blocks (1:1½:3) with stone chips and nominal reinforcement.(a) Block size 250 x 125 x 75mm. |
| 5 | Taking out old damaged tarfelt from the roof, parapet etc. preparing the roof surfaces by removing all spoils, blisters, moss etc. from the working site and disposal of the same beyond the compound and cleaning the site in all respect as per direction of Engineer-in-Charge. |
| 6 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. |
| 7 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge |
| 8 | Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately) (a) Upto area 2.5 Sq.m |
| 9 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm. |
| 10 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation. |
| 11 | A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)(B) Do-by-find Sand. |
| 12 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. |
| 13 | (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor.(A) [Pakur Variety](a) 1:3:6 proportion |
| 14 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.a) Pakur Variety |
| 15 | Hire and labour charges for shuttering with centering and necessary stagingupto 4 m using approved stout props and thick hard wood planks of approvedthickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out aftercompletion of works (upto roof of ground floor) (f) 25 mm to 30 mm shuttering without staging in foundation |
| 16 | Brick work with 1st class bricks in cement mortar (1:6)(a) In foundation and plinth. In Ground floor |
| 17 | (b) In superstructure, In Ground floor |
| 18 | In 1st floor |
| 19 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.a) For works in foundation, basement and upto roof of ground floor/upto 4m.II. JSW/JSPL/SHYAM/ SRMB/ BMASL/ ELECROSTEEL/SSL In Ground Floor |
| 20 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. boundary walls |
| 21 | a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department] |
| 22 | Cement concrete (1:1.5:3) with graded stone chips 5.6 mm size with hexagonal square mesh wire netting, I.R.C. fabric mesh or X.P. M. fitted and fixed after tying the existing reinforcement on concrete without distributing the same and with proper scarping and cleaning the reinforcement and disturbed concrete with wire brush etc. after applying a coat of cement including the cost of wire netting I.R.C or X. P. M. & cost of all handling and scaffolding complete as per direction of Engineer-in -charge.c) 37.5mm thick |
| 23 | Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge. |
| 24 | Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer's specification] [Mode of measurement:The affected surface area of reinforcement shall be considered for payment]For RCC Damaged portion |
| 25 | Applying epoxy based reactive joining agent for joining the old concrete withfresh concrete to be applied within manufacturer's specified time as permanufacturers specification. (0.4 Kg / m² of concrete surface). |
| 26 | Supplying, fitting & fixing granite tiles 10mm to 12mm. thick in columns, wall, facia etc. with 15 thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete. [Using cement slurry at back side of tiles @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m]Area of each slab upto 0.2 Sq.m |
| 27 | Dismantling worn out wall or ceiling of Tarja or Durmamat and removing the dismantled materials as directed. |
| 28 | Providing and fixing of 15mm thick Mineral Fibre Acoustic Ceiling Tiles of approved pattern and size 595mm X 595mm should be placed in the Grid module to form a False Ceiling with NRC value ≥ 0.6 Material class: A2-s1, d0 as per EN 13501-1, Fire: REI-REI120 as per EN 13501- 2, Surface Burning Characteristics: Class 1 or A as per ASTM E 84) with powder coated exposed G.I. grid suspension system (interlocking T-Grid, having load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins/ soffit. All complete as per the drawing & directions of Engineer-in-charge.In ground floora) With 15 mm thick mineral fibre false ceiling tile (NRC> 0.6 as per ASTM C 423 & Sound attenuation - 34dB as per EN ISO 10848) |
| 29 | Supplying and fitting in all places of wall panelling to all heights and fixing on pre- framed existing frame work grid with glass wool of 50mm thick having density of 48 Kg per cum. to be inserted into the pre - fabricated slot covered the glass wool by marking cloths treated with Naptha @ 0.07 Ltr.per Sq.m. of cloths. Finally 12.5mm thick gypsum Fulton board having size 595mmX595mm fitted & fixed into the pre-fabricated grid and covered the all perifirial gaps of fulton board by self additive fibre tape with necessary filler if required, complete in all respect as per direction of the Engineer-in-charge. |
| 30 | Taking out Mirzapur or glazed porcelain tiles carefully by chiselling from walls or floor including stacking erviceable material as directed. |
| 31 | Supplying and laying true to line and level vitrified tiles ofapproved brand (size not less than 600 mm X 600 mm X 10mm thick) in floor, skirting etc. set in 20 mm sand cementmortar (1:4) and 2 mm thick cement slurry back side of tilesusing cement @ 2.91Kg./sqM or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stonefloor/Mosaic etc without any backing course) laid afterapplication slurry using 1.75 Kg of cement per sqM belowmortar only, joints grouted with admixture of white cementand colouring pigment to match with colour of tiles / epoxygrout materials of approved make as directed and removal ofwax coating of top surface of tiles with warm water andpolishing the tiles using soft and dry cloth upto mirror finishcomplete including the cost of materials, labour and all otherincidental charges complete true to the manufacturer'sspecification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be suppliedby the contrr]e) |
| 32 | Supplying & laying 3mm thick pre-fabricated plastomericwater proofing membrane conforming to EN 12311-1 &ASTMD 5147, manufactured with atactic poly propylene(APP) modified premium grade asphalt , specially reinforcedwith non-woven polyester core with polyester reinforcement@160 gms per sqm & both faces covered with thermo-fusiblepolyethylene film /MineraL on top face over a coat of primer@ 0.40 lit/sqm of manufacturer's specification onsmooth,clean dry surface prepared wherever required.Lapjoint shall be provided of 75 mm in longitudinal & 100 mm intransverse direction and fused using LPG/ Propane torchemploying extra care ensuring full bondage, completeremoval of entrapped air and sealing edges into grooves inappropriate manner as per direction of Engineer -in-chargeall complete including materials,labour and applicabletaxes. (Payment shall be made on the basis of finishedsurface area.).Membrane Property: Softening Point > 150 deg C, ColdFlexibility < -6 deg C, Tensile Strength, N/cm : 600(longitudinal), 450 (transverse), Tearing Strength,N:300(longitudinal), 200 (transverse)Same area of Taking out terfelt |
| 33 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortarincluding rounding off or chamfering corners as directed andraking out joints including throating, no sing and drip course, scaffolding / staging where necessary (Ground floor).20mm Thick (1:6) |
| 34 | In 1st Floor |
| 35 | (i) With 1:6 cement mortar (c) 15 mm thick plasterIn Ground Floor |
| 36 | In 1st Floor |
| 37 | 10 mm thick(1;4) |
| 38 | Neat cement punning about 1.5mm thick in wall, dado, windowsill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. |
| 39 | Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria. |
| 40 | Supplying,fitting&fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibrere in forced plastic moulded skin and a specials and wich core,so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.In ground floor |
| 41 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)Ground Floor |
| 42 | For 1st floor |
| 43 | Scraping of moss, blisters etc.thoroughly from exterior surface of wallsnecessitating the use of scraper, wire brush etc.(Payment against thisitem will be made only when this has been done on the specific directionof the Engineer-in-charge) |
| 44 | Applying Exterior grade Acrylic primer of approved quality and brandon plastered or cencrete surface old or new surface to receivedecorative textured (matt finish) or smooth finish acrylic exterioremulsion paint including scraping and preparing the surface throughly,complete as per manufacturer's specification and as per direction of the EIC.In Ground Floor:a) One Coat. |
| 45 | For 1st floor |
| 46 | Protective and Decorative Acrylic exterior emulsion paint of approvedquality, as per manufacturer's specification and as per direction ofEngineer-in-Charge to be applied over acrylic primer as required. Therate includes cost of material, labour, scaffolding and all incidentalcharges but excluding the cost of primer.In Ground floor (Two Coat)b) Premium 100% Acrylic EmulsionFor Ground floor |
| 47 | For 1st floor |
| 48 | Removing old scales, blisters etc. of interior surface of walls,ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (1:2) (as necessary), to make the surface suitable for receiving distemper. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge). |
| 49 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface.Two Coats |
| 50 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof. |
| 51 | a) M.S.or W.I. Ornamental grill of approved design jointscontinuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in groundfloor.Brick work with 1st class bricks in cement mortar (1:6)(b) In superstructure, ground floor(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. |
| 52 | I) For hanging and locking arrangements including supply ofmaterials and labour complete..(15% extra over the corresponding item of grill ) |
| 53 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or bothfaces of M.S./ W.I. gate etc. with point welding at not more than150mm apart complete in all respect as per design including cost ofall labour and materials. |
| 54 | a) Priming one coat on steel or other metal surface with synthetic oilbound primer of approved quality including smoothening surfaces by sandpapering etc. |
| 55 | (A) Painting with best quality synthetic enamel paint of approved makeand brand including smoothening surface by sand papering etc. includingusing of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :(iv) Two coats (with any shade except white) |
| 56 | (A) Painting with best quality synthetic enamel paint of approved makeand brand including smoothening surface by sand papering etc. includingusing of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface(ii) Two coats (white in shade) |
| 57 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming toIS:13592-1992 with all necessary clamps nails, including making holes inwalls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining withjointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.(ii) 110mm dia |
| 58 | (iii) 160 mm. Dia |
| 59 | UPVC fittings Bend 87.5 degree (ii) 110mm |
| 60 | (iii) 160 mm. Dia |
| 61 | UPVC Shoe 110mm(ii)110 mm |
| 62 | (iii) 160 mm. Dia |
| 63 | a) Plain Tee(ii)110 mm |
| 64 | (iii) 160 mm. Dia |
| 65 | b) Plain Y(ii) 110 mm |
| 66 | (iii) 160 mm. Dia |
| 67 | Uprooting and removing plants from the surface of wallsparapet etc and making good damages. (Repairing ofdamages to be paid separately).(a) Small plant of girth of exposed stem upto 75 mm. lift upto 6 mtr. |
| 68 | Clearing compound premises of shurbs, plants, jungles etc.by cutting and removing as directed (Specific permission ofEngineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared) |
| 69 | Taking out rain water down pipe.upto 6 mtr. |
| 70 | Taking out carefully G.C.I. or C.I. or asbestossheets (including ridges etc.) from roof or wall after unscrewing bolts, nuts, screws etc.andstacking the material at site as directed. |
| 71 | Single skin color coated trapezoidal profile for wall ceallingi) i) in roof (a) 0.5 mm thick sheet |
| 72 | Supplying best Indian sheet glass panes set in putty and fitted and fixedwith nails and putty complete. (In all floors for internal wall & upto 6m height for external wall) (ii) 4 mm thick |
| 73 | Supplying, fitting and fixing G.I. pipes of TATA make with all necessaryaccessories, specials viz. socket, bend, tee, union, cross, elbo, nipplelongscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixingetc. complete in all respect including cost of all necessary fittings asrequired, jointing materials and two coats of painting with approved paintin any position above ground. (Payment will be made on the centre linemeasurements of total pipe line including all specials. No separatepayment will be made for accesories, specials. Payment for painting willbe made seperately)(ii) 40mm dia medium quality. |
| 74 | Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings.(iv) 40mm dia |
| 75 | Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.)40mm dia |
| 76 | Supplying P.V.C. water storage tank of approved quality with closed topwith lid (Black) - Multilayer(b) 1000 Litre Capacity. |
| 77 | Labour for hoisting plastic water storage tank.i) Upto 1500 litre capacity. |
| 78 | Labour for punching hole in plastic water storage tank upto 50 mm dia. |
| 79 | Supplying, fitting and fixing low-down cistern parts.(i) Internal fittings for cistern complete of approved make. |
| 80 | Cleaning and removing mud upto 2000 litre Water Tank including masonry reservoir. |
| 81 | Supplying, fitting and fixing white vitreous china best quality approvedmake wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks,C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillarcock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approvedquality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approvedquality P.V.C. connection pipe with heavy brass C.P. nut includingmending good all damages and painting the brackets with two coats ofapproved paint. |
| 82 | Supplying, fitting and fixing pedestal of approved make for wash basin(white) |
| 83 | Supplying, fitting and fixing bib cock or stop cock.(a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511& Model - Tropical / Sumthing Special of ESSCO or similar bran |
| 84 | Refixing wash basin with brackets with or without waste fittings. |
| 85 | Cleaning glazed tiles with acid. |
| 86 | Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc.(a) with 'P' trap |
| 87 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in whitevitreous chinaware of approved make in position with brass screws on 75mm X 75 mm X 75 mm wooden blocks complete.(i) 635 mm X 395 mm X 420 mm |
| 88 | Removing sludge from septic tank, soak well etc. by methor labour including disposal of the same outside the compound as directed.(b) Upto 30 users.i) within a lead of 150 mtr. |
| 89 | Cleaning soak pit by removing the top slab and replacing inner filling withjhama bats and repairing the pit as necessary including fitting the slab. |
| 90 | Cleaning silt of inspection pit. |
| 91 | Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver redas per I.S. 3438 / 1965 together with brass C.P. hinges.(ii) 600mm X 450mm |
| 92 | Supplying, fitting and fixing soap holder.a) PTMT (Prayag or equivalent) |
| 93 | KDS-16,1HP (.75KW) 220 volt Kirloskar Momo Block Pump. |
| 94 | 1HP BGH panel board for Momo Block Pump. |
| 95 | Supply & lowering of 6mm water proof PVC coated steel rope hanging pump.through well |
| 96 | S & F falf round type holding clamp to hold the column pipe including S&F nut bolt washer as per direction of EIC. |
| 97 | Supplying fitting & fixing of 4.0sqm/mm. 3 core submersible flat cable. |
| 98 | Supplying fitting & fixing for 10mm steel rope for suspension of pump. |
| 99 | Add G.S.T. @ 18% |
| 100 | Add L.W.Cess @ 1% Please Enable Macros to View BoQ information |