Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Schedule 1 - Part A - KPWD SR 2024-25 Items - Civil |
| 2 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. |
| 3 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work |
| 4 | In all kinds of soils Depth upto 3 m-In all kinds of soils- (Consider 70% of total excavation) |
| 5 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. (Page no.5 item 4.1 P.W.D. SR-2021-22 vollume -II) |
| 6 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. |
| 7 | Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates-Consider for Formwork 3% (all other types ) |
| 8 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates |
| 9 | Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) |
| 10 | M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates |
| 11 | Ground Floor - Consider for Formwork 70% (For Columns) |
| 12 | Ground Floor -Consider for Formwork 60% (RCC Beams and Lintels of building) |
| 13 | Ground Floor -Consider for Formwork 50% (roof) |
| 14 | First Floor - Consider for Formwork 70% (For Columns) |
| 15 | First Floor -Consider for Formwork 60% (RCC Beams and Lintels of building) |
| 16 | First Floor -Consider for Formwork 50% (roof) |
| 17 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. |
| 18 | Ground Floor |
| 19 | First Floor |
| 20 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 21 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainlesssteel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. |
| 22 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 30 mm thick Both side teak |
| 23 | Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 24 | Ground Floor |
| 25 | First Floor |
| 26 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. |
| 27 | Ground floor |
| 28 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 29 | Steel Fabrication-Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification-(a) Buildings |
| 30 | Ground Floor |
| 31 | First Floor |
| 32 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. |
| 33 | Ground Floor |
| 34 | First Floor |
| 35 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.- inside plastering |
| 36 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge |
| 37 | Ground Floor |
| 38 | First Floor |
| 39 | Second Floor |
| 40 | Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two coat applied @ 1.67 l/ 10 m²) on existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge |
| 41 | Ground Floor |
| 42 | First Floor |
| 43 | Second Floor |
| 44 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. |
| 45 | Ground Floor |
| 46 | First Floor |
| 47 | Second Floor |
| 48 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications. Second floor |
| 49 | Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates |
| 50 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. |
| 51 | Ground floor |
| 52 | First floor |
| 53 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge.For thickness of tiles 10 mm to 25 mm |
| 54 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar |
| 55 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material to the appropriate disposal area as per direction of Engineer-in-charge.. - -Asbestos cement sheet |
| 56 | Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional span of one metre or part thereof beyond 10 m : of sectional area 40 cm^2 and above |
| 57 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 design mix using 20mm nominal size graded crushed coarsed aggregates |
| 58 | consider formwork 35% (Drain) |
| 59 | Removal of old broken glass panes ( any thickness of size, quality or description ) from wooden frames, glazed with putty or fixed with beads including cost of labour, complete as per specifications. |
| 60 | Providing and fixing plain rolled glass 4mm thick with teakwood beading of 10mm thick. |
| 61 | Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fi with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and making good walls) 15mm nominal OD Pipe |
| 62 | Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fi with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and making good walls) 20mm nominal OD Pipe |
| 63 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 64 | Providing and fixing PTMT grating of approved quality and colour 100 mm nominal dia |
| 65 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, , (i) Single socketed pipes. |
| 66 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes of 150mm dia conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 67 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 |
| 68 | constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 500X700 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :With common burnt clay (non modular) bricks of class designation 3.5 |
| 69 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay (non modular) bricks of class designation 3.5 |
| 70 | Extra for depth for manholes : Size 90x80 cm With common burnt clay (non modular) bricks of class designation |
| 71 | Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fi with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and making good walls) 20mm nominal OD Pipe |
| 72 | Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fi with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and making good walls) 25 mm nominal OD Pipe |
| 73 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal sibility for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work |
| 74 | 25mm nominal OD pipes |
| 75 | 32mm nominal OD pipes |
| 76 | 40 mm nominal OD pipes |
| 77 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : |
| 78 | 25 mm nominal bore |
| 79 | 40 mm nominal bore |
| 80 | Providing and fixing unplasticised PVC connection pipe with brass unions : |
| 81 | 15 mm nominal bore |
| 82 | 20 mm nominal bore |
| 83 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : |
| 84 | Horizontal |
| 85 | Vertical |
| 86 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 87 | 15 mm nominal bore |
| 88 | 20 mm nominal bore |
| 89 | KSRB 13-11.1 : Providing and placing on terrace,(All floor levels )polyethylene water storage tank IS :12701 Marked , with cover and suitable locking arrangement and marking necessarry holes for inlet , outlet and over flow pipes but with out fitting andthe base suuport for tank |
| 90 | Removing of existing old or broken wash basin / urinals/ Indian Water closet/ European Water closet and disposing it with all cost and conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. |
| 91 | Providing and fixing Angle cock light with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Premium |
| 92 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid - Ground floor and First Floor |
| 93 | Providing and fixing Pillar Cock made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy |
| 94 | for hot and cold |
| 95 | for wash basin |
| 96 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 97 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 98 | Cleaning Seftic Tank of more than 100 users capacity as per details and instructions.(While cleaning septic tank all safety and precautionary measures to be taken,Standard Operating Procedure to be adopted and PEMSR Act 2013 to be strictly followed). |
| 99 | Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction m³ jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm |
| 100 | cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in- charge. |
| 101 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge |
| 102 | Providing & fixing vertical blinds of reputed make of shape 100mm regular fabric with powder coated aluminium channel, telting with PVC Chain system with all necessary fittings and fixtures as per direction of Engineer in charge |
| 103 | Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete |
| 104 | 20 mm diameter |
| 105 | Water purification plants: Providing, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components |
| 106 | 100 LPH : Cabin Type |
| 107 | Schedule -1 - Part - B - I - KPWD SR 2023-24 Items - Electrical |
| 108 | Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 2X1.5Sqmm (Phase & Neutral) & 1X1.0 sqmm (Earth Wire) FRLS multi strand PVC insulated copper wire (Confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. |
| 109 | Short point up to 3 Mtr from tapping point to out let via switch box |
| 110 | Medium point above 3 Mtr up to 6 Mtr from tapping point to out let via switch box |
| 111 | Long point above 6 Mtr up to 10 Mtr from tapping point to out let via switch box |
| 112 | Supplying and Flush mounting powder coated/Galvanized metal Box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone/ C.C Wal |
| 113 | 1-2 Way |
| 114 | 3 Way |
| 115 | 4 Way |
| 116 | 6 Way |
| 117 | 8 Way |
| 118 | 10-12 Way |
| 119 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete. |
| 120 | 1 to 2 Module |
| 121 | 3 Module |
| 122 | 4 Module |
| 123 | 6 Module |
| 124 | 8 Module |
| 125 | 10-12 Module |
| 126 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 |
| 127 | 6 Amps one way Switch |
| 128 | 6 A Two way Switch. |
| 129 | 6 Amps Three way socket. |
| 130 | Stepped Fan Regulator Two Module |
| 131 | 32 Amps DP switch |
| 132 | 6/16 Amps universal socket |
| 133 | TV / Telephone Socket |
| 134 | RJ 45 / I.O Outlet Cat-6 |
| 135 | Supplying And Fixing Metal Fan Box with Round Hook. |
| 136 | Supplying heavy gauge PVC conduit pipe......mm dia..........mm thick confirming to IS2509 with suitable size bends,metal/PVC Junction boxes,adhesive paste etc.,and running before concreting the slab.The conduit should be tied to there inforcement rods by using binding wires and un used ways of junction boxes and pipe ends should be covered using PVC end enclosures,run with 18 SWG GI fish wire wherever necessary |
| 137 | 19/20 mm dia 2 mm thick |
| 138 | 25 mm dia 2 mm thick |
| 139 | Supplying heavy gauge PVC Conduit Pipe....dia.......mm thick with suitable size bends,metal junction boxes adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. |
| 140 | 19/20 mm dia 2 mm thick |
| 141 | 25 mm dia 2 mm thick |
| 142 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to latest amendments |
| 143 | 1.5 sqmm |
| 144 | 2.5 sqmm |
| 145 | 4 sqmm |
| 146 | 6 sqmm |
| 147 | Distribution boards : Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. |
| 148 | II - Double Door |
| 149 | 12 Way SP & N |
| 150 | III - Double Door |
| 151 | 4 Way TP&N |
| 152 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve , indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. |
| 153 | 6-32 Amps SP |
| 154 | 40 Amps DP |
| 155 | 6-32 Amps TPN |
| 156 | 50-63 Amps TPN |
| 157 | Supplying, fixing and wiring Residual Current breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. |
| 158 | 32-40 Amps 2 pole |
| 159 | 32-40 Amps 4 pole |
| 160 | Supplying and fixing regular MCCB distribution Panel confirming to IS / IEC61439 - 3 and IK 09 tested as per IS / IEC62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket , with suitable earthing system, on wall / woodboard / flush mounting using required c l A, bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB ' sasanin comer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3 phase 4 wire powder coated painting etc.,complete with aprovision for fixing of single/three phase suitable capacity MCB's as out goings confirming to IS/IEC 60898 - 2. |
| 161 | 4 Way |
| 162 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood / panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as per IS / IEC60947-2. (Icu=100 % lcs). In 4 P MCCB, all Poles should have protection for Short-Cicrcuit/OverLoad. For Micro processor MCCB S Facility for segregating Priority and Non - Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi - pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. |
| 163 | 100 A 25 kA |
| 164 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. |
| 165 | 63 A TP |
| 166 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V @ 50/60Hz & Power factor >0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. |
| 167 | LED light fighting 1 X 4' - 20/22 w |
| 168 | Supply of LED Street light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded poly carbonate material , delivering superior light out put Rated life Burning Hr s 50000 hr @ Lumen Maintenance of 70 % , maximum light intensity should be between 60 degrees to 70 degrees . CCT > 5500K , IP66 optical and electrical compartment & impact resistance of complete luminaire > IK08 . Power Factor > 0.9 with mains , Surge Protection - Min 5 KV along with Over voltage / Overload , short circuit / miss - wiring protection . Compatible for pole mounting with outer dia of 40 mm to 50 mm.Universal Voltage driver to operate wide voltage range from 100 V to 270 V 50 / 60 Hz application. Compliance to IS10322 / IEC60598 , LM79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with........ W System Power consumption . LED Efficiency > 1301 m /w , nominal CRI > 75.Luminaire manufacturer should have in -house facility ac credited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO9001 : 2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree / Nichia / Lumileds / Osram make LED Source.PWD |
| 169 | LED Streetlight 70W |
| 170 | Supplying and fixing of 230 volts 20/40 watts Fluorescent Lamp holder |
| 171 | Supplying & fixing retrofit type -PL- LED Lamp W LED linear source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. |
| 172 | 8-9 Watts |
| 173 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. |
| 174 | 48\\" Sweep (1200mm) Regular model |
| 175 | Supplying wall mounting fan suitable to operate at single -phase 230 v AC. supply. |
| 176 | 12\\" Sweep (300mm) |
| 177 | Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GIorrailor RCC pole/wall using suitable clamps,bolts,and nuts and wiring using suitable capacity wires. |
| 178 | Using 32mm dia G.I.Pipe |
| 179 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. |
| 180 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling/ rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps |
| 181 | On wall / ceiling / Rafter / Girders |
| 182 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. |
| 183 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. Ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire. |
| 184 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. |
| 185 | GI/Copper strips for grounding connections, using necessary fixing materials as required. |
| 186 | 25 X 3 mm GI strip |
| 187 | 600 x 600 x 3 mm Copper Plate |
| 188 | Schedule -1 - Part - B - II - ESCOM SR 2023-24 Items - Electrical |
| 189 | 1.1 KV , XLPE or Heat resistivity PVC insulated, PVC exutruted inner seath Armoured LTUG Cable as per IS-1544(Part -1) or 7098 part - 1, Armouring strip thickness and resistivity as per IS-3975 - |
| 190 | 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) |
| 191 | Laying of cable in Existing Trench/GI pipe/Stone Ware/ RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff - |
| 192 | 35 to 95 Sqmm |
| 193 | Heavy Duty Copper Terminal Long Barrel |
| 194 | 25 Sqmm Copper Terminal, Apprx Wt: 26 Gm |
| 195 | Brass Cable Gland |
| 196 | 25 mm Please Enable Macros to View BoQ information |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail