| 1 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a) Depth of excavation not exceeding 1,500 mm. |
| 2 | Earthwork in filling in foundation trenches or plinth with good earth in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete.i) With earth obtained from excavation of foundation. |
| 3 | A) Filling in foundation or plinth by silver sand inlayers not exceeding 150 mm as directed andconsolidating the same by thorough saturation withwater, ramming complete including the cost of supplyof sand. |
| 4 | Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. |
| 5 | Cement concrete with graded stone ballast (40 mm size excluding shuttering). In ground floor and foundation.(A) Pakur Variety. 1:3:6 proportion. |
| 6 | Hire and labour charges for shuttering with centering and necessary staging up to 4mtr. using approved stout, props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels, curved or straight including fitting, fixing and striking out after completion of works.b) 25 mm to 30 mm shuttering without staging in foundation. |
| 7 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. a) Tor steel. (JSW/JSPL/ SHYAM/SRMB/ELECTROSTEEL) i) For works in foundation, basement and upto roof of ground floor upto 4 m. |
| 8 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm.nominalsize) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes.--a) Pakur Variety. |
| 9 | Ordinary cement concrete (mix 1:1.5:3) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per IS codes. a) Pakur variety. |
| 10 | A) Brick work with 1st. Class bricks in C.M. ( 1: 6) (a) In foundation and plinth |
| 11 | A) Artificial stone in floor, dado, staircase etc. with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted) with ordinary cement.Using grey cement. (i) 25 mm. thick(In ground floor only) |
| 12 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Exxcluding cost of chipping over concrete surface.] (i) With 1:6 cement mortar(b) 15 mm. thick plaster. In ground floor. |
| 13 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE: Cement 0.152 cu. M. per sq.m. |
| 14 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 15 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. (b) On steel or other metal surface : : With other than (hi-gloss) -(iv) Two coats (with any shade except white) |
| 16 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.--Flash butt welded windows and ventilators--(no shop priming will be allowed to facilitate inspection of workmanship) Without integrated grills i) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bar (i) In Ground floor |
| 17 | iv) Two point nose steel handle including fitting and fixing. |
| 18 | vi) steel peg stay 300 mm long including fitting and fixing. |
| 19 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.-----I) For structural members of specified sections weighing less than 22.5 Kg./m |
| 20 | Asbestos corrugated (Trafford or similar approved quality) sheet (6 mm thick) work (excluding the supportingframework) fitted and fixed with 9.5mm. dia. J or L hook-boltand nuts, limpet and bitumen washers and putty with 150 mm end lap & one corrugation minimum side lap complete. (b) In Wall |
| 21 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). (i) In Roof:- a) With 0.5 mm thick sheet |
| 22 | Supplying at site or stackyard or as directed PCC (1 : 2 :4) Fencing Post 215 cm 150 mm X 150 mm section at bottom, 100 mm X 100 mm section at top with T-Base 300 mm X 150 mm X 100 mm, having 4 nos 6 mm dia vertical M.S. reinforcement and 6 mm dia binders @ 200 mm centres, finished smooth etc, complete. |
| 23 | Fixing post of iron or precast concrete by digging hole in the ground (in all sorts of soil) and embedding the same by packing the hole with cement concrete (1:3:6) (with jhama khoa. For Purulia, Bankura and Darjeeling Hill by Pakur Variety, Local Black Hard Stone & Bazree respectively) and finishing the top surface to regular shape (as directed) with 15 cm cement plaster (1:6) complete, including the cost of concrete, plaster etc.but excluding the cost of the post.(ii) Average dia. of the hole 300 mm. to 400 mm.(a) Depth 450 mm. to 500 mm.(Cement- 14..35 Kg/No.) |
| 24 | Supplying, fitting galvanised 3 ply 12 gauge / 4 points line ofbarbed wire in fencing (holes already made in the body of the post) or fixed by staples tightening and fixing the wires in taut condition with straining bolts including the cost of cutting and of lapping joints in the wire as necessary but excluding the cost of galvanised staples,straining bolt and binding wire where necessary. Please Enable Macros to View BoQ information |