|
| 1 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 2 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 3 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 4 | Second class teak wood |
| 5 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 6 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 7 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : |
| 8 | 100X58X1.90 mm |
| 9 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer-in-Charge. |
| 10 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing. |
| 11 | 30 mm thick plain PVC door shutters |
| 12 | Providing and fixing Stainless steel Aldrop of approved quality with screws etc. complete : |
| 13 | 250x16 mm |
| 14 | Providing and fixing Stainless steel Tower bolt of approved quality with screws etc. complete : |
| 15 | 250x10 mm |
| 16 | Providing and fixing Stainless steel round latches of approved quality with screws etc. complete : |
| 17 | 250x12mm |
| 18 | Providing and fixing stainless steel handle with necessary screws etc. complete. |
| 19 | 100 mm |
| 20 | Providing and fixing stainless steel hanging floor door stopper with necessary screws etc. complete. |
| 21 | Single rubber stopper |
| 22 | Providing and fixing 35 mm wooden cup board or wardrobe knob of approved quality with necessary screws as per the direction of Engineer in charge. |
| 23 | Providing and fixing 25mm dia. SS curtain rods with SS brackets fixed with screws and PVC sleeves etc. wherever necessary complete as per the direction of Engineer in charge. |
| 24 | Repalcing existing damaged wire gauge in doors & windows shutter by Providing and fixing fly proof galvanized SS 304 wire gauge using wire gauge with average width of aperture 16x18mm with wire of dia 0.22 mm of approved quality with screws and existing available 12 mm mild steel U beading etc. all complete as per the direction of the Engineer-in-charge. (The clear inside area of panel shall be measured for payment. The rate includes of all above operations nothing extra shall be paid. The cost of MS beading shall be paid for separately if required.) |
| 25 | Repalcing existing damaged wire gauge in doors & windows shutter by Providing and fixing fly proof galvanized SS 304 wire gauge using wire gauge with average width of aperture 16x18mm with wire of dia 0.22 mm of approved quality with nails, & second class teak wooden beading wherever required etc. all complete as per the direction of the Engineer-in-charge.( The clear inside area of panel shall be measured for payment. The rate includes of all above operations nothing extra shall be paid. ) |
| 26 | Reparing of pelmet and fixing to wall by screws, clamps wherever required etc. all complete as directed by Enginner-in-charge. |
| 27 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 28 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 29 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. |
| 30 | G.I. pipes |
| 31 | Repairing of MS steel windows/windows grill with or without taking out fixed/openable shutter/grill and getting repair at any floor level by welding of grill/ M. S. butt hinges /holdfast/straightening/ cutting of members and other required arrangment for proper functioning of window etc and fixing in position as directed by engineer-in-charge. ( The item includes cost of all opearations and MS hingesof any type, labours and tools and plant etc. but excluding cost of scaffolding and glass panes which shall be paid for seperately in relevant item.) |
| 32 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc. complete. |
| 33 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 34 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 35 | 110 mm diameter |
| 36 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. The item excludes cost of scaffolding which shall beincluded in relevant item of scaffolding for maintenance work. |
| 37 | Coupler |
| 38 | 110 mm diameter |
| 39 | Bend 87.5° |
| 40 | 110 mm diameter |
| 41 | Shoe (Plain) |
| 42 | 110 mm diameter |
| 43 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 44 | 110 mm |
| 45 | 12 mm cement plaster of mix : |
| 46 | 1:6 (1 cement : 6 coarse sand) |
| 47 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 48 | 1:6 (1 cement : 6 coarse sand) |
| 49 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : |
| 50 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 52 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead. |
| 53 | With cement mortar 1:4 (1cement: 4 coarse sand). |
| 54 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 55 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 56 | Renewal of old putty of glass panes (length) |
| 57 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with \\"S\\" or \\"P\\" trap including dismantling of old WC seat and \\"S\\" or \\"P\\" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. |
| 58 | Orissa pattern W.C Pan of size 580x440 mm |
| 59 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. |
| 60 | Dismantling 15 to 40 mm dia G.I. pipe with fittings including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer in-Charge. |
| 61 | Internal Work- Exposed on wall |
| 62 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 63 | Fixing of loose Aldrop, Stopper, Latch, handle etc. fixed to door/window shutter with necessary screws, rawl plugs, Bolts & Nuts etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 64 | Deduct for providing 3mm thick Bajari glass panes instead of ordinary float glass panes weighing 4 mm thick in steel glazed doors, windows and clerestory windows shutters and ventilations. |
| 65 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 66 | In cement mortar |
| 67 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 68 | Of area 3 sq. metres and below |
| 69 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : |
| 70 | Of area 3 sq. metres and below |
| 71 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 72 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 73 | For thickness of tiles 10 mm to 25 mm |
| 74 | Dismantling C.I. or asbestos or PVC rain water pipe/drainage pipes with fittings and clamps including stacking the material within 50 metres lead : |
| 75 | 75 to 80 mm dia pipe |
| 76 | 100 mm dia pipe |
| 77 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : |
| 78 | 15 mm to 40 mm nominal bore |
| 79 | Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. |
| 80 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 81 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 82 | Disposal of building rubbish/ malba/ similar unserviceable dismantled or waste materials by mechanical means including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all loads including all lifts involved. Please Enable Macros to View BoQ information |
| 83 | Disposal of building rubbish/ malba/ similar unserviceable dismantled or waste materials by mechanical means including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all loads including all lifts involved. Please Enable Macros to View BoQ information |