| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge All kinds of soil : |
| 2 | Disposal of excavated earth for a lead of 1km by MT including loading and unloading complete. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 4 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with |
| 6 | 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 7 | 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 8 | Providing and laying cement concrete below flooring in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etcupto floor V level, including curing but excluding the cost of centring, shuttering and finishing with. 1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size |
| 9 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 10 | Providing and laying in position machine batched and machine mixed design mix M-25 rade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works upto plinth level |
| 11 | All works upto plinth level |
| 12 | All works above plinth level upto floor V level |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 14 | Providing and laying autoclaved aerated cement blocks masonrywith150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately). |
| 15 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 16 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 17 | Centring and shuttering including strutting propping etc and removal of form work |
| 18 | Foundations, footings, bases of columns etc. for mass concrete |
| 19 | Suspended floors, roofs, landing, balconies and access platforms. |
| 20 | columns, Pillars,Piers, Abutments, Posts and Struts. |
| 21 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 22 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 23 | Edge of slabs and break in floors and walls Under 20 cms wide. |
| 24 | Weather shade, chajjas, corcels etc., including edes. |
| 25 | Providing & fixing T-iron frames for doors, windows & ventilators of mildsteel Tee-sections, joints mitred & welded, including fixing of necessarybutt hinges & screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of C.C. 1:3:6 (1cement : 3 coarse sand :6 graded stone aggregate 20mm nominal size) . |
| 26 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1stclass hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 27 | Providing and fixing aluminum work for doors, windows, ventilators andpartitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 andIS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides withrequired EPDM rubber / neoprene gasket felt etc. Aluminum sectionsshall be smooth, rust free, straight, mitred and jointed mechanicallywherever required including cleat angle, Aluminum snap beading forglazing / panelling, C.P. brass / stainless steel screws, all complete as perarchitectural drawings and the directions of Engineer-in-Charge (glazing,panelling and dash fasteners to be paid for separately.) Powder coated aluminum (minimum thickness of powder coated 50 microns) |
| 28 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) Powder coated aluminum (minimum thickness of powder coated 50 microns) |
| 29 | Providing and fixing glazing in aluminum door, window, ventilatorshutters and partitions etc. with EPDM rubber / neoprene gasket etc.complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.) With floating glass panes of 4.0 mm thickness (weight not less than 10.00 kg / sqm) |
| 30 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in-charge. (Cost of aluminum snap beading shall be paid in basic item.) With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm) |
| 31 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in charge. |
| 32 | Filling the gap in between aluminium/ stone/ wood frame and adjacentRCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providingweather/structural non sag elastomeric PU sealant over backer rod ofapproved quality as per architectural drawings and direction of Engineer Upto 10 mm depth and 10 mm width |
| 33 | Providing and fixing double action hydraulic floor spring of approvedbrand and manufacture IS : 6315 marked, having brand logo embossedon the body/plate with double spring mechanism and door weight upto125 kg for doors including cost of cutting floors, embedding in floors asrequired and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheetouter box with slide plate etc. complete as per the direction of Engineerin- plate etc. complete as per the direction of Engineer-in-charge. With Stainless Steel cover plate minimum 1.25 mm thickness |
| 34 | Providing and fixing aluminum tubular handle bar 32mm outer dia, 3.0mm thick & 2100mm long with SS screw etc. complete as per direction of Engineer-in-charge. Powder coated minimum thickness 50 micron aluminum tabular handle bar |
| 35 | Providing and fixing aluminum casement windows fastner of requiredlength for aluminum windows with necessary screws etc. Complete Anodized (AC 15) aluminum |
| 36 | Providing and fixing aluminum casement windows fastner of requiredlength for aluminum windows with necessary screws etc. Complete Powder coated minimum thickness 50 micron aluminum |
| 37 | 75x63x3.2 mm |
| 38 | 100x75x4 mm |
| 39 | Providing and fixing 18mm gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels (Area of slab upto 0.5 sqm) |
| 40 | Extra for providing edge moulding to 18 mm thick Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 41 | Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing, making of edge moulding & nosing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) : |
| 42 | Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing, making of edge moulding & nosing and curing complete. |
| 43 | Providing and laying vitrified floor tiles in different sizes (thickness tobe specified by the manufacturer) with water absorption less than 0.08%and conforming to IS:15622 of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand)including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 44 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete. Size of tile 600x600 mm |
| 45 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown |
| 46 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in whiten cement mixed with pigment of matching shade complete. |
| 47 | Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counters and similar location in marble/granite / stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete |
| 48 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge. |
| 49 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 50 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 coarse sand)incl. all lifts, carriage of material by MT/HL. |
| 51 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 52 | Providing and applying white cement based putty of specified thickness,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 1 mm thick |
| 53 | Distempering with oil bound washable distemper of approved brand andmanufacture to give an even shade on New work (two or more coats) overand including priming coat with water thinnable cement primer |
| 54 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 55 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work ( wood work). |
| 56 | Providing and fixing hand rail of approved size by welding etc. to steelladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube |
| 57 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 58 | Providing and fixing in position collapsible steel shutters with verticalchannels 20x10x2mm and braced with flat iron diagonals 20x5 mm size,with top and bottom rail of T-iron 40x40x6mm, with 40mm dia, steelpulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer |
| 59 | Providing and fixing ISI marked oxidized M.S. tower bolt black with nuts and screws etc. complete. |
| 60 | 300x 16 mm |
| 61 | 250x 10 mm |
| 62 | Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete. |
| 63 | 200x10 mm |
| 64 | 250x16 mm |
| 65 | Providing and fixing bright finished brass handles with screws etc. complete: 9.82.1 125 mm |
| 66 | 125 mm |
| 67 | 100 mm |
| 68 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete |
| 69 | Providing and fixing aluminum casement stays, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 70 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x10 mm |
| 71 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.100 mm |
| 72 | Providing and fixing aluminum extruded section body tubular type universal hydraulic door closer,(having brand logo with IS: 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete : |
| 73 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggreagate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.incl. all lifts, carriage of material by MT/HL. |
| 74 | Forming groove of uniform size in the top layer of washed stonegritplaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge : 15 mm wide and 15 mm deep groove |
| 75 | Add for plaster drip course/grooves in plastered surface or moulding to R.C.C. projections. |
| 76 | Providing and laying water proofing treatment in sunken portion ofWCs, bathroom etc., by applying cement slurry mixed with waterproofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with waterproofing cement compound @ 0.253kg/ sqm. This layer will be allowedto air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of alljoints, corners, junctions of pipes and masonry with polymer mixedslurry. |
| 77 | Providing and applying integral crystalline slurry of hydrophilic innature for waterproofing treatment to the RCC structures like retainingwalls of the basement, water tanks, roof slabs, podiums, reservoir,sewage & water treatment plant, tunnels / subway and bridge deck etc.,prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry: 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystallineslurry : 1 part water) for horizontal surfaces and applying the same fromnegative (internal) side with the help of synthetic fiber brush. Thematerial shall meet the requirements as specified in ACI- 212-3R-2010i.e by reducing permeability of concrete by more than 90% comparedwith control concrete as per DIN 1048 and resistant to 16 bar hydrostaticpressure on negative side. The crystalline slurry shall be capable of selfhealing of cracks up to a width of 0.50mm. The work shall be carried outall complete as per specification and the direction of the engineer-incharge. The product performance shall carry guarantee for 10 yearsagainst any leakage. For horizontal surface one coat @1.10 kg per sqm. |
| 78 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design. In 75x75 mm deep chase |
| 79 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 80 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 81 | Providing and fixing on wall face unplasticized - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.110 mm diameter |
| 82 | Providing and fixing on wall face unplasticised- PVC moulded fittings/accessories for unplasticised- Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 1 0 mm gap for thermal expansion .- Bend 110mm |
| 83 | Providing and fixing un-plasticised -PVC pipe clips of approved design to un-plasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 84 | Providing and fixing PVC pennelling for false ceiling including cutting, fixing of light panesl etc complete job |
| 85 | Providing and fixing wall panelling including cutting, fixing of light panels etc complete job. |
| 86 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete. |
| 87 | Providing and fixing Anodized aluminum grill (Anodized transparent or dyed to required shade according to IS: 1868 minimum anodic coating of Grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing windows frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved Anodized aluminum standard section around the opening, all complete as epr requirement and direction of Engineer-in-charge. (only weight of grill to be measured for payment) |
| 88 | Supplying and laying including digging, carrying by lorry, filling River Bed Material including watering & consolidation in layers to specified lines, camber, grades and cross sections. Finished work |
| 89 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. |
| 90 | carriages of materials by mechinical trancsport incl. loading, unloading and stacking complete |
| 91 | Sand for a lead of 5 kms. |
| 92 | stone agg below 40mm 5 kms |
| 93 | stone agg 40 mm and above 5 kms |
| 94 | Bricks for an avg lead of 5 kms |
| 95 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 96 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid. |
| 97 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265mm sizes respectively. |
| 98 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps. |
| 99 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040mm bowl depth 250mm |
| 100 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge |
| 101 | Providing and fixing P.V.C. Waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe (only in residential & complaxes) |
| 102 | 32 mm dia |
| 103 | 40 mm dia |
| 104 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shape with 6 mm thick hard board backing Rectangular shape 453x357mm |
| 105 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 106 | Providing and fixing soil waste PVC pipes 110 mm dia.of approved quality Complete |
| 107 | Providing and fixing soil waste PVC pipes 75 mm dia. of approved quality Complete |
| 108 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun)/ PVC pipe embedded in and includingcement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : For 100 mm dia. Pipe |
| 109 | Providing and fixing plain PVC bend of required degree. of approved quality Complete |
| 110 | 100 mm dia |
| 111 | 75 mm dia |
| 112 | Providing and fixing PVC TEE of approved quality Complete |
| 113 | 100 mm dia |
| 114 | 75 mm dia |
| 115 | Providing and fixing PVC door bend of approved quality Complete |
| 116 | 100 mm dia |
| 117 | 75 mm dia |
| 118 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. |
| 119 | Waste coupling 31mm dia of 79mm length and 62mm breadth weighing not less than 45gms. |
| 120 | Waste coupling 38mm of 83mm length and 77mm breadth |
| 121 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, 78 mm wide and effective height of 88 mm, weighing not less than 190 gms |
| 122 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 123 | Providing and fixing PVC floor trap 100x 75 mm of approved quality |
| 124 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. |
| 125 | 15 mm nominal outer dia Pipes |
| 126 | 20 mm nominal outer dia Pipes |
| 127 | 25 mm nominal outer dia Pipes |
| 128 | 32 mm nominal outer dia Pipes |
| 129 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including allCPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge External work including trenching, refilling etc. 50 mm nominal outer dia .Pipes. |
| 130 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall medium . |
| 131 | 40 mm dia nominal bore |
| 132 | 50 mm dia nominal bore |
| 133 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) |
| 134 | 40 mm dia |
| 135 | 50 mm dia |
| 136 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 137 | 15 mm nominal bore |
| 138 | 20 mm nominal bore |
| 139 | 25 mm nominal bore |
| 140 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter |
| 141 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 142 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 143 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gm, 15 mm nominal bore |
| 144 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 145 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gm, 15 mm nominal bore. |
| 146 | Providing and fixing PTMT grating of approved quality and colour. Circular Type 125 mm nominal dia with 25mm waste hole |
| 147 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in charge. |
| 148 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms. |
| 149 | Cutting holes upto 30x30 cm in walls including making good the same : With common burnt clay (non modular) bricks. |
| 150 | Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. |
| 151 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg andweight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 152 | Constructing brick masonry road gully chamber of specified size with common burnt clay(non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4coarse sand) including precast R.C.C. horizontal grating with frame complete as per standard design: Chamber size 50x45x60 cm including precast R.C.C grating with frame 500x450 mm horizontal grating. |
| 153 | Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 154 | Providing and fixing inauguration stone including engraving, painting, writing and cost. Of pedestal of 5 feet height by way of brick work, plastering, tiling and painting complete job. Please Enable Macros to View BoQ information |