| 1 | Part A: Video wall |
| 2 | Supply installation testing comissioning of P1.8 Active LED video wall as per the specification given below Pixel:1.8Material:Die Casting AluminumCabnet size 640*360*65mm 16:9 cabinet Module size:320*180mmpanel, Anti-torsion, anti-collision, anti-vibration and Good Power supply: Megmeet, power efficient ≥95% PowerConsumption (Max):≤440 W/m2Pixeldensity(dot/㎡): 286666.7 Refreshrate:≥3840Hz Brightness:≥700cd/m2 Grayscale:≥14bit ContrastRatio:≥3000:1 Screen Size 18.90ft x 10.63 ft IPRating:IP40/IP21HFR(HighFrameRate Support HFR+ mode (120Hz high frame rate)Ultra-low latency enables real-time image display;Reduces delays in transmission of video sources, synchronizes the display of real-time images Certificates FCC,CE,ETL,CB,ROHS ,CCC (Barco/Samsung/Absen/LG/Christie) |
| 3 | Supply installation testing and commissioning of Active led controller with Mobile App. WIFI, LAN, USB,and HDMI facility. INPUT OUTPUT LOADING CAPACITY:-650,000 pixels Maximum width: 2048 pixels, maximum height: 2048 pixels,1x Gigabit Ethernet output port,1x Stereo audio output connector,1x USB 2.0 (Type A) port:- Allows for USB playback,1x Fast Ethernet port:-Connects to the control computer, or connects to a LAN or public network for content publishing and screen control. firmware upgrade and storage expansion. (Novastar,samsung/christie) |
| 4 | Part B: Audio System |
| 5 | Supply installation testing comissioning of Non-powered minimum Two-Way, Bi-Amplified or Passive Operational Line Array Speaker; The Line Array should be Coaxical/Onaxis LF/HF Driver Full Range Loudspeaker, Frequency Response: 60 Hz - 19 kHz or better; Loudspeaker consisting min 1x12\\" Low Frequency Driver or better, and 1 x 1.5\\" HF Compression Driver or better, Norman Horizontal Dispersion: 100° or better; Effective Vertical Dispersion: 30° or better in each set (for individual speaker vertical dispersion to be 10 deg or better); Impedence-16/8/4 Ohm; Maximum Peak SPL - LF & HF : 130dB or better; Power Continuous: 900 watts or better(Tw audio/Louis Martin/Bose/QSC) |
| 6 | Supply installation testing comissioning of flying hardware for main FoH Speaker mounting with High-strength Cold Rolled Steel with a powder-coated finish to resist environmental wear and high load capacity with various weight option upto 5 Kg to 50 Kg with adjustments |
| 7 | Supply installation testing comissioning of Two-Channel Professional Amplifier based on Class TD technology, combining the efficiency of Class D amplifiers with the sonic purity of Class B amplifiers. The amplifier shall deliver an output power of 850W × 2 at 8Ω (stereo) and 1250W × 2 at 4Ω (stereo). It shall provide a frequency response of 20 Hz – 20 kHz (±0.5 dB), with THD+N - 0.05% at 8Ω, 1 kHz, and a signal-to-noise ratio greater than 95 dB (A-weighted). The amplifier shall offer a damping factor greater than 500 and crosstalk greater than 70 dB (1 kHz @ 8Ω). It shall feature selectable input sensitivity of 0.775V / 1.44V and input impedance of 20 kΩ (balanced) / 10 kΩ (unbalanced). For safe and reliable operation, the amplifier shall be equipped with clip limiters, over-temperature protection, and short-circuit protection.(Tw audio/Louis Martin/Bose/QSC) |
| 8 | Supply installation testing comissioning of Two-Way Full Range Passive Loudspeaker equipped with one powerful 10” (254 mm) LF driver and one 1.34” (34 mm) HF driver. The system shall be high-performance, versatile, and passive in design, with a Frequency Response of 60 Hz – 19 kHz, RMS Power of 300W, and Peak Power of 1200W or Higher, The loudspeaker shall have a Sensitivity of 96 dB (1W/1m) or better, Maximum SPL of 123 dB (Continuous/1m) and 126 dB (Peak/1m) or better, with a Nominal Impedance of 8 Ohms. It shall operate in Passive Crossover Mode and provide Dispersion of 90° (H) × 50° (V). The cabinet should be made of high-density plywood to ensure durability and superior acoustic performance.(Tw audio/Louis Martin/Bose/QSC) |
| 9 | Supply installation testing comissioning of wall mount speaker bracket for delay speaker with High-strength Cold Rolled Steel with a powder-coated finish to resist environmental wear and high load capacity with various weight option upto 5 Kg to 50 Kg and adjustable nose. |
| 10 | Supply installation testing comissioning of passive subwoofer speaker, equipped with 2 × 18” high-performance low-frequency drivers in a front-loaded enclosure design. The system should be equipped with high-power European drivers and deliver a frequency response of 38 Hz – 120 Hz. The loudspeaker shall have a RMS Power handling capacity of 1500W or Higher and a peak power of 6000W or Higher. The sensitivity (1 W / 1 m) shall be 102 dB or higher, with a maximum SPL of 136 dB continuous and 139 dB peak at 1m. The nominal impedance shall be 4 Ohms with omnidirectional dispersion characteristics. The cabinet should be constructed using multi-layer high-density plywood for durability and superior acoustic performance.(Tw audio/Louis Martin/Bose/QSC) |
| 11 | Supply installation testing comissioning of Two Channel Professional Class-D Amplifier with output power of 1600W × 2 per channel at 8Ω (stereo) and 2600W × 2 per channel at 4Ω (stereo) or Higher. The amplifier shall have a Frequency Response of 20Hz – 20kHz (±0.5dB), THD+N - 0.05% @ 8Ω, 1kHz, and Signal-to-Noise Ratio - 98dB (A-weighted) or better, It should have a Damping Factor - 1000 (1kHz @ 8Ω) or Higher, Input Sensitivity selectable at 0.775V / 1.44V, and Input Impedance of 20kΩ (balanced) / 10kΩ (unbalanced). The unit shall be equipped with clip limiters, over-temperature protection, and short-circuit protection, ensuring reliable performance in professional audio applications.(Tw audio/Louis Martin/Bose/QSC) |
| 12 | Supply installation testing comissioning of Powered Active Stage Monitor minimum Two-way Coaxial or better, having frequency resposne: 55 Hz - 19 kHz or better; Loudspeaker consisting min 1x12\\" Low frequency driver or better, & 1 x 1.5\\" HF Compression driver or better, Nominal Horizontal Dispersion: 90° or better ; Effective Vertical Dispersion: 60° or better, Minimum Continuous SPL: 122 dB or better, Maximum Peak SPL: 128 dB or better, Has minimum 3 DSP presets: Music | Monitor | Low Cut or better, Minimum Continuos Power: 500W & Peak Power should be 1200W or better. 1.2 mm perforated weatherised steel with protective foam or better.(Tw audio/Louis Martin/Bose/QSC) |
| 13 | Supply installation testing comissioning of Up to 40 channels Digital Mixing console with 17 motor faders (8 channels + 1 master) 40 input mixing channels (32 mono + 2 stereo + 2 return) 20 Aux (8 mono + 6 stereo) + Stereo + Sub buses 8 DCA groups with Roll-out 16 analog XLR/TRS combo mic/line inputs + 2 analog RCA pin stereo line inputs 16 analog XLR outputs 34 x 34 digital record/playback channels via USB 2.0 + 2 x 2 via a USB storage device,8 Effects and 10 GEQ 1 expansion slot for Dante audio interface card.(Tw audio/Louis Martin/Bose/QSC/YAMAHA/DIGCO) |
| 14 | Supply, Installation, Testing & Commissioning of Digital Signal Processor with 8 Mic/Line inputs, 8 Line outputs and 8 software assignable channels, configurable as Mic/Line Inputs or Line outputs. The processor shall have minimum 24 assignable & routable AEC channels and 8 General Purpose Inputs (GPI) x 8 General Purpose Outputs (GPO) ports. The processor shall have minimum 8x8 Dante channels and shall also support up to 160x160 Network audio channels via Dante or AES67 or similar protocol. It shall also support SIP Softphone integration for Audio conferencing and configurable 16x16 USB Audio channels via USB-B or Type-C ports supporting AV USB Bridging for software or web based conferencing applications. The processor shall also have minimum 24 bit-A/D-D/A converters, 48 kHz Sample rate, Input frequency response of 20 Hz to 20 kHz @ +21dBu, Input dynamic range > 109.5 dB at @ +24 dBu sensitivity. The processor shall support third party device control via Ethernet, RS232 and GPIO and shall have front panel display for control and indicators for device status.(Tw audio/Louis Martin/Bose/QSC/Biamp) |
| 15 | Supply, Installation, testing and commissioning of Gooseneck Microphone, it should be pre-polarised condenser microphone having Super Cardioid or better polar pattern, shall have frequency response of 50Hz to 20kHz, length of the gooseneck shall be more than 595mm, Should have Max SPL Level of 125dB or more, it should support phantom power from 12v to 48v, Should be RF interference free from other wireless devices, etc complete required as per the specifications.(Sennheiser / Shure / Audiotechnica) |
| 16 | Supply installation testing comissioning of Digital Wireless hand held microphone with cardioid polarity pattern, Frequency range: 471 - 797 MHz or better, THD total harmonic distortion ≤ -60 db for 1kHz @ -3 dBfs input level or better ; Switching bandwidth up to 56 MHz or better; up to 2240 selectable Frequencies for allow fine tuning, equidistant tuning grid of 600kHz to enable up to 90 simultaneous channels . Sensitivity 2.1 mV/Pa or better, Sound pressure level 150 dB SPL or more. RF output 10mW or more, up to 8 hours of operating time or better, Audio Frequency Response of 80Hz-18kHz (-3db) @ 3dbfs, Bluetooth connectivity with mobile devices for basic setup and control of the receiver complete with standard accessories.(Sennheiser /Shure/Audiotechnica) |
| 17 | Supply installation testing comissioning of Digital Wireless Lapel microphone with Omnidirectional or better polarity pattern, Frequency range: 471 - 797 MHz or better, THD total harmonic distortion ≤ -60 db for 1kHz @ -3 dBfs input level or better ; Switching bandwidth up to 56 MHz or better; up to 2240 selectable Frequencies for allow fine tuning, equidistant tuning grid of 600kHz to enable up to 90 simultaneous channels . Sensitivity in free field 17 mV/Pa or better, Sound pressure level 130 dB SPL or more. RF output 10mW or more, up to 8 hours of operating time or better, Audio Frequency Response of 20Hz-20kHz (-3db) @ 3dbfs, Frequency Response: 50-18000Hz, Bluetooth connectivity with mobile devices for basic setup and control of the receiver complete with standard accessories.(Sennheiser /Shure/Audiotechnica) |
| 18 | Supply, Installation, Testing & Commissioning of Digital Wireless Microphone External Antenna, Active antenna splitter should have 2 x 1:4 or better configuration, transmission operating in the UHF spectrum, Auto scan features, 134 dB or better audio input dynamic range , 56 MHz of tuning bandwidth and provision up to 90 channels, 2,200 or more selectable frequencies, Should come with required antenna connection cables, should from the same brand as wireless microphone to ensure 100% compatibility.(Sennheiser / Shure / Audiotechnica) |
| 19 | Supply, Installation, Testing & Commissioning of directional antenna with Impedance:50 Ohm; Connector: BNC; Pick-up pattern: directional; Frequency range: 470 - 1075 MHz ;Antenna gain: 5 dBi or better, should come with connection cable and mounting accessories as required, should from the same brand as wireless microphone to ensure 100% compatibility.(Sennheiser / Shure / Audiotechnica) |
| 20 | Supply, Installation, Testing & Commissioning of Antenna Cable, Antenna Cable should be of 50ohm, Should be LMR 400 Cable or RG8 standard, Should be compatible with the wireless antenna system |
| 21 | Supply installation testing comissioning of inline antenna booster module with BNC connectors, designed to offer typ. +12dB of boost to compensate for signal losses created by long antenna cable runs. The AB 4 is fully compatible with all legacy evolution wireless systems. Additionally, the AB 4's filters have been expanded to support the bandwiths up to 88 Mhz.(Sennheiser / Shure / Audiotechnica) |
| 22 | Supply, Installation, testing and commissioning of drum kit 1no. Dynamic cardioid bass instrument microphone with integral stand mount (Frequency response : 20 - 16000 Hz, Nominal impedance : 350 Ω or better, Min. terminating impedance : 1000 Ω), 4no. Dynamic cardioid instrument microphone ( Frequency response : 40 - 18000 Hz, Sensitivity : 1.8 mV/Pa or better, Nominal impedance : 350 Ω or better, Min. terminating impedance : 1000 Ω), 2no. High-grade cardioid condenser microphone (Frequency response : 40 - 20000 Hz, Sensitivity : 3 mV/Pa or better, Nominal impedance : 100 Ω or better, Min. terminating impedance : 1000 Ω, etc complete required as per specifications and compliance.(Sennheiser / Shure / Audiotechnica) |
| 23 | Supply, Installation, testing and commissioning of Floor Stand for microphones typically requires high-quality, professional-grade equipment designed for durability and stability in auditorium or live performance environments lspecifications steel construction, adjustable height mechanisms, and, for gooseneck models, specialized anti-vibration bases. |
| 24 | Supply, Installation, testing and commissioning of 10.9\\" (10th Gen) Touch panel depending on the UI complexity.Storage: Minimum 64GB ,Connectivity: Dual-band Wi-Fi 6 (802.11ax) and Bluetooth 5.3. Liquid Retina display with at least 500 nits brightness for visibility in bright Mounting Type: On-wall or In-wall Tamper-resistant mounting with security screws to prevent theft in public areas.(Apple, Samsung) |
| 25 | Supply, Installation, testing and commissioning of 4G wifi router Speed: Up to 3 Gbps,Coverage: 360° spherical coverage,4 Gigabit LAN ports,Advanced parental controls, WPA3,Speed: 300 Mbps,External antenna,Speed: 2.4 GHz up to 300 Mbps, 5 GHz up to 867 Mbps,ADSL wireless router with double antenna,Security: Encryption features, double firewall protection.(Netgear/janiper/D link/TP link) |
| 26 | Supply, Installation, testing and commissioning of Gigabit managed or unmanaged device with a minimum or maximum power efficiency of 60W to 120W, supporting IEEE 802.3af/at standards Must include 8 x 10/100/1000Base-T RJ45 ports with PoE+ supp Should support a packet forwarding rate of approximately 11.9 Mpps to 14.8 Mpps.(D-Link/Netgear/Cisco/Janipur) |
| 27 | Supplying and fixing 42U Rack with 6 inch Castor wheels and front brake Floor Standing Rack with Main Frame Pillar of 1.6mm CRCA Sheet with removable side panels, L- Shape adjustable Vertical Mounting Rail of 2mm with 'U'Marking completely knocked-down condition (CKD) Shape, fitted with 4 number cooling fans, minimum 8nos two line cable entry/exit provision at top and bottom with rubber protection, Front door 5mm Toughened Glass with MS frame or MS perforated with lock, Rear MS vented or perforated door, Powder coated Color- RAL-7035 or black, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. |
| 28 | Supply, Installation, testing and commissioning of Cable and connectors MICROPHONES CABLES 2-core bare copper with a 24 AWG (7x32) stranded formation for high flexibility and signal integrity.Shielding: High-density bare copper spiral shield designed to reject noise in live and studio environments, SPEAKER CABLES FOR high-performance audio solutions 2-core (typically Black/Red) and 4-core (Black, Red, White, Green) twisted pairs to improve noise rejection AND COONECTOR xlr OR AS PER SITE REQUIREMNTS |
| 29 | Supply, Installation, testing and commissioning of HDMI Matrix Switcher, Connects any of 4HDMI Sources to 4 HDMI displays. upports 4K Resolution upto 4096x2160@60Hz, max. Distance 5m / 4K@60Hz (4:4:4) 15m / 1920 x 1200, HDMI (3D, Deep Color, 4K) and HDCP 2.2 Compatible(Liberty / Extron / Kramer) |
| 30 | Supply, Installation, testing and commissioning of HDMI transmiter and reciver POE based Approved make Aten/kristone/amx/krame(Liberty / Extron / Kramer) |
| 31 | Part C: Digital Podium |
| 32 | Supply, Installation, testing and commissioning of Digital Podium with touch 19\\" monitor,goosneck mic,2speakers,amplifier, i5 4 GB RAM, 500 GB HDD, Windows, keyboard mouse, steel body powdercoated having official logo of the intending department i.e., \\"Government Medical College Srinagar\\" embossed. |
| 33 | Part D: Electrical works |
| 34 | Supplying, installation, Testing & Commissioning of 18Watt LED Recessed/ surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 35 | Supplying, Installation, Testing & Commissioning of 36 Watt Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuitprotection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 36 | Supply/Installation/Testing and Commissioning of 22-24 watt ultra slim LED surface mounted lighting panels(300mm x 300mm) having CRCA Body (Commercial type), minimum lumens 100-125 lm/w ,the luminaire housing should be crca /aluminium and the luminair optics shall have a high efficency with transmittance ,average life of 50000 hrs operating temperature -10 C to + 45 C. The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures (Philips/Wipro/Jaguar/Bajaj/Surya /Havells/Equivalent Make) & shall be approved by Executive Engineer/AEE. |
| 37 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Polycab/Anchor/Finolex Make) & shall be approved before execution of work. |
| 38 | 2 × 1.5 sq.mm + 1 × 1.5 sq.mm (P+N+E) |
| 39 | 2 × 2.5 sq.mm + 1 × 2.5 sq.mm (P+N+E) |
| 40 | 2 × 4 sq.mm + 1 × 4 sq.mm (P+N+E) |
| 41 | Annual Maintenance Charges (AMC) for Three Years Post DLP Period Please Enable Macros to View BoQ information |