| 1 | Schedule 'A' Part-I (B/R itmes)Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key scrubbing down with water, etc. ,complete all as specified and as directed. |
| 2 | Material and labour for rendering 15mm thick on any faces of brick work or concrete wall surfaces in cement mortar (1:6) and finished even and smooth without using extra cement, complete, all as specified and as directed. |
| 3 | Material and labour for rendering 15 mm thick on any faces of brick work or concrete wall surfaces in cement mortar (1:4) mix with WPC @ 2% wt of cement and finished even and smooth without using extra cement, complete, all as specified and as directed. Note: The rates is inclusive of providing scaffolding and safty eqpts for height upto 15 to 20 Mtrs and nothing extra shall be admissible into this account.(Note:- WPC shall be measured paid for separately) |
| 4 | Supply only integral water proofing compound,complete all as specified and as directed. |
| 5 | Material and labour for applying three coats of white wash wash on wall surface including preparation of new plastered surfaces of walls, cornices etc. (plastered or unplastered) by brooming down, up to height of double storey bldg, including necessary scaffolding etc complete all as specified and as directed. |
| 6 | Material and labour for preparation of new plastered/unplastered surfaces of walls, chajjas, roof projection, etc. and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed. |
| 7 | Taking down chowkats or frames with shutter area not exceeding 1.50 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish ,complete all as specified and as directed. |
| 8 | Supply and Fixing double shutter steel window box type ERW hollow P section comprising of glazed/gauged skeleton shutter fabricated from following sections :-(a) ERW hollow P section frame of size 60 mm x25 mm made from 1.25 mm thick MS sheet (02 Nos i.e. 01 for glazed shutter and 01 for gauzed shutter ). Both P section shall be welded with flat iron 25x03 mm thick all around of frame on both inner and outer faces . (b) Style and rails of window shutters shall be fabricated with ERW hollow P section of size 50 mm x25 mm made from 1.00 mm thick MS sheet and comprising of 02 Nos sash bars for glazed window leaf of T – section 20 x 03 mm thick and one No sash bar of 20 mm x 3 mm thick section for gauzed winodw leaf .(c) Vertical mullion shall be ERW hollow T -section of size 60 x 25 mm made from 1.25 mm thick MS sheet (d) The above steel window shall be deemed to include the following accessories/ fittings : i) Hold fast 150mm long mild steel flat iron 12x3 mm thick made to shape- 04 Nos per window ii) Handle of Z section 20mmx25mm, 100mm long – 01 No per leaf.iii) MS tower bolt stove enamelled 150mm long- 2 Nos per leaf. iv) Z section 20mmx25mm, 100mm long stopper – 01 No per leaf. (v) Cleat 55 mm long of solid square 15x20x.63mm square - 01 No per leaf vi) Pintal hinges 12 x 75 mm - 2 Nos each leaf vii) 10mm square Guard bar @ 10 cm c/c welded to frame .(viii) Two coat of Synthetic enamel paint over one coat of red oxide primer.(ix) 0.36mm nominal dia of stainless steel wire mesh and average width of aperture of 1.40mm fixed in gauzed skelton shutter of window with flat iron 15 x 03 mm with steel screws .(x) 3mm thick sheet glass, ordinary quality and with oil putty in square n. exc 0.5 sqm in each pane fixed in glass shutter of window.(xi) Fabrication and fixing arrangements as per specification including cutting holes and making good dismantled portion in PCC 1:2:4 type B-1 /cement plaster 1:4 as require and make finish good to the existing surface complete all as specified and directed.Notes : (i) For the purpose of measurement and payment double shutter both glazed and gauzed with frames shall be considered as one unit.(ii) Unit rate quoted against this item shall also include the iron mongery, grill and other accessoriries as mentioned above.(iii) The window upto 1.00 metre width shall consists of two leaves both for gauzed shutter and glazed shutter and all the shutters are openable. The window more than 1.00 metre width shall have two openable leaves on both outer side for gauzed shutter and glazed shutter and middle leaf/shutter shall be fixed type.iv) Unit rate quoted against this item shall be double shutter both glazed and gauzed with frames. |
| 9 | Taking down chowkats or frames with shutter area exceeding 1.50 Square meter and not exceeding 4.00 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish ,complete all as specified and as directed. |
| 10 | Supply and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other frames/ chowkhat of size 50 x 75 mm comprising of virgin PVC polymer of K value 58–60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant , ,complete all as specified and directed. |
| 11 | S&F factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-in-Charge. (Note: stainless steel butt hinges and necessary SS screws shall be paid separately) complete all as specified and as directed by the Engr–in–charge. |
| 12 | Supply and fixing 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed ,complete all as specified and as directed. |
| 13 | Supply and fixing 150 mm long aluminium handle cast type anodised, complete all as specified and as directed. |
| 14 | Supply and fixing 300 mm long aluminium sliding door bolts, plate type, stove enamelled black with bright bolt not less than 12 mm dia with and including minimum of 6 bolts and nuts, four on bolt plate and two on staple and fixed , complete, all as specified and as directed. |
| 15 | Material and labour preparation of old decorated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coat of synthetic enamel paint , complete, all as specified and as directed. |
| 16 | Dismantling of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar, etc. but excluding ashlar facing, dressed stone work and precast concrete articles ,complete all as specified and as directed. |
| 17 | Material and labour for brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 ,complete all as specified and as directed. |
| 18 | Demlition of Reinforced Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) Roofs, floors (other than ground floors), beams, staircases, landing, chajjas, lintels and similar suspended work ,complete all as specified and as directed.(Reinforcement cut to facilitated dismantling ) |
| 19 | Material and labour for providing cement concrete 1:2:4 Type B0 using 12.5mm graded aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth, string, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating ,complete all as specified and as directed.. |
| 20 | Material and labour for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips ,complete all as specified and as directed. |
| 21 | Dismantling asbestos cement (corrugated, semi corrugated, etc.) plain sheets in roof coverings including ridges ,complete all as specified and as directed. |
| 22 | Supply and Fixing pre–painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick, having zinc coating 150 gm per sqm (Az–150) of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws ,complete all as specified and as directed. |
| 23 | Supply and Fixing pre–painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, having zinc coating 150 gm per sqm (Az–150) as in roof covering/ cladding to wall, fixed with self tapping screws ,complete all as specified and as directed. |
| 24 | Supply and Fixing rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., quality confirming to GDE Fe 410-S ,complete all as specified and as directed. |
| 25 | Demolition of Cement concrete (Unreinforced) of any description in ground floors and pavings n exe 15 cm thickness (below or above ground level) ,complete all as specified and as directed. |
| 26 | Material and labour for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over a screed bed 20mm thk in CM 1:4 all as specified and as directed. |
| 27 | Material and labour for machine cut kota stone slab flooring 12-16mm thick a in skirting over cement plaster 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing ,complete all as specified and as directed. |
| 28 | Material and labour 100 mm thick PCC 1:4:8 Type D–2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement complete all as specified and as directed. |
| 29 | Material and labour for pavement quality concrete work thickness 25cm or less as in pavement/ hardstanding of flexural strength 40 Kg per Sqcm in field using 400 Kg of cement per cubic metre, using form work if required, complete all as specified and as directed. |
| 30 | Material and Labour for Machine pressed precast cement concrete coloured , rubber moulded, interlocking designer paver blocks( double glossy) in any and shape, confirming to IS-15658-2006 of 80mm thickness, M-40 grade in path, hard standing, etc. laid over and including 50 mm thick bedding layer of sand complete, all as specified and as directed . |
| 31 | Dismantling Brick tiles or terracing tiles, single layer on roofs , complete, all as specified and as directed. |
| 32 | Demolition of mud in roofs, any thickness, including plastering and leeping (whethere full thickness removed or only a part thereof) including emoving old tar felt, all loose dirt, cement plaster, cleaning the concrete surface including removal & cleaning of vegetation, fungus, moss, small trees etc from the roof top with wire brush, removing the strips of lightening conductor including refixing the same after repair work , complete, all as specified and as directed. |
| 33 | Material and labour for providing cement concrete (1:2:4), Type B1, using 20mm graded crushed stone aggregate as in roof kerbs or mud stops, roof padding, etc., rounded or chamfered on edges including from work where ever required , complete, all as specified and as directed. |
| 34 | Material & Labour for providing and laying 3mm thick APP (atactic polypropylene polymer) modified prefabricated five layer weight not less than 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt and consisting of a coat bituminous primer @ 0.40 litre /Sqm by the same membrane manufactures of density 0.87 to 0.89 kg/ltr at 25 degree centegrate temperature and viscosity 70–160 cps over the primer coat with overlap of 100mm at the side and 150mm at the end, the layer membrane shall be laid using butane gas torch and sealing all joints etc. after preparing the surface complete as per standred practice as per manufacture's instructions. The vital physical and chemical parameters of the membrane shell be under :–(i) Joint strength in longitudinal and transverse direction at 23 degree centegrate at 650/ 450 N /5 cms(ii) Tear strength in longitudinal and transverse direction at 300/250N/5 cms. Softing point of membrane not less then 150 degree centegrate when tested in accordance with ASTM (d–5147)(iii) The laying of membrane shell be got down through the authorised applicator of manufactures of membrane only , complete, all as specified and as directed.(iv) The work shall be carriout at a height upto 12 metre. |
| 35 | Material and labour cement concrete tiles 30 cm x 30cm x 20 mm thick, machine pressed laid on screed bed and joints grouted and pointed flush in cement mortar (1:3) mixed with 5% crude oil by weight of cement including screed bed 15 mm thick in cement mortar (1:6) , complete, all as specified and as directed. |
| 36 | Material and labour machine pressed rubber moulded coloured precast concrete interlocking paver block, any shape and size conforming to IS 15658–2006 of 60 mm thickness, grade M–35 with grey cement and pigments over and including a layer of sand cushioning, 25 mm thick complete all as specified and as directed . |
| 37 | Material and labour PCC 1:4:8, Type D–2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 38 | Material and labour for providing and laying at or near ground level factory made kerb stone of M–25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified. |
| 39 | Schedule 'A' Part-II (E/M itmes)Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc., complete, all as specified and as directed. |
| 40 | Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling surfaces and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade, ISI marked with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. for one light/fan/exhaust fan/bell point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately . |
| 41 | Description all as per serial item No.40 here-in-before but for One 3 pin, 6 Amps, socket outlet controlled by one switch on independent board, complete, all as specified and as directed. |
| 42 | Description all as per serial item No.40 here-in-before but for One 3 pin 6 Amps socket outlet controlled by one switch on same board, complete, all as specified and as directed. |
| 43 | Description all as per serial item No.40 here-in-before but for one socket outlet 16 Amp with 2.50 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.50 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade, ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly , complete, all as specified and as directed.Note : (i) Point wiring shall be done in a manner that not more than 02 socket point executed in one circuit.(ii) Each socket point will be measured and paid as per point. |
| 44 | Supply and fixing of modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts, , complete, all as specified and as directed. |
| 45 | Supply and fixing of modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts , complete, all as specified and as directed. |
| 46 | Supply and fixing of modular socket outlet multipin combined, 6 Amp, one way, two module, 230 volts , complete, all as specified and as directed. |
| 47 | Supply and fixing of modular socket outlet multipin combined, (6pin), 6/16 Amp, one way, two module, 230 volts , complete, all as specified and as directed. |
| 48 | Supply and fixing electronic Fan regulator, modular 100 watts, 02 module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep, complete, all as specified and as directed. |
| 49 | Supply and fixing ceiling rose surface type 2/3 terminal polycarbonate, isolated body , complete, all as specified and as directed. |
| 50 | Supply and fixing in repair LED batten fitting 20 watt, 4 feet, polycarbonate housing with electronic driver cool/warm type, connecting with copper conductor flexible cable from ceiling rose to connector of the light, ,complete all as specified and as directed.. Cat part No. LBLN-20-C-SQ of make Orient or equivalent make given in Appx 'B'. |
| 51 | Supply and fixing in repair, LED Bldg Security Light Fittings of capacity 40-45 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including electronic driver and making electrical connection, ,complete all as specified and as directed.. Cat part No.LSFS-45-CF-PC of make Orient or HLSLD-14-40-CWDL-R01 of make Halonix or equivalent make given in Appx 'B'. |
| 52 | Supply and fixing sheet metal MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral with double door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces ,complete all as specified and as directed. Cat part No.811807 of make Indo Asian or equivalent in make given in Appx 'B'. |
| 53 | Supply and fixing MCB SP, 6-32 Amps, 240 volt,10 KA , 'B' curve as per site requirement including removing old unserviceable MCB , ,complete all as specified and as directed. Cat Part No 811008 to 811015 of make Indo Asian or equivalent in make given in Appx 'B'. |
| 54 | Supply and fixing MCB SPN 32 Amps, 240 volt,10 KA , 'B' curve as per site requirement including removing old unserviceable MCB , ,complete all as specified and as directed. Cat Part No 811034 of make Indo Asian or equivalent in make given in Appx 'B'. |
| 55 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to earthing test point as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing as in repair, complete all as directed by Engineer-in-Charge and earth testing on completion . |
| 56 | Supply and Laying or fixing or passing through pipe or laid in trenches and testing cable XLPE insulated, armoured heavy duty electric cable with multistranded aluminium conductor 1100 volts grade, 2 core of size 16 Sq.mm as in repair ,complete all as specified and as directed.. |
| 57 | Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc. and getting out for soft/loose soil, ,complete all as specified and as directed. |
| 58 | Supply and lay in repair, GI tubes light grade with connected fittings laid in trenches/wall/ pole for protection to UG cables of size 32 mm dia., ,complete all as specified and as directed. |
| 59 | Material and labour for cushioning for protection of cable using dry river sand, free from particles, ,complete all as specified and as directed. |
| 60 | Material and labour for Protection to cable with one layer of new bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks, ,complete all as specified and as directed. |
| 61 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceedig 25cm for soft/loose soil, ,complete all as specified and as directed. |
| 62 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceedig 1.5 m above the starting point, ,complete all as specified and as directed. |
| 63 | Note:- Amount of credit of Rs.29,490..00 for retrieved materials is mentioned in Schedule of Credit Page No. 123 of tender doCubic metre ents in pdf form which will be deducted offline while acceptance of tender. Please Enable Macros to View BoQ information |