|
| 1 | Dismantling Plain or corrugated steel sheeting, any gauge and thickness in roof covering, including Nainital or similar pattern roof coverings, complete all as specified and as directed. |
| 2 | M&L Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 3 | M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 4 | Dismantling of wall and celling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness inlcuding cover fillets, complete all as specified and as directed. |
| 5 | M&L for 4 mm thick veneered decorative Ply wood, grade 1 (with BWR resin) with decorative face veneers on one face has decorative veneer fixed with nails to timber frame work on ceiling etc, complete all as specified and as directed. |
| 6 | M&L for 4 mm thick veneered decorative Ply wood, grade 1 (with BWR resin) with decorative face veneers on one face fixed with nails to timber frame work on wall , complete all as specified and as directed. |
| 7 | Dismantling timber scantling 40 sq cm and over in section in any position as in unframed work, complete all as specified and as directed. |
| 8 | M&L for second class soft wood (Kail) clean swan timber fixed in scantling, complete all as specified and as directed. |
| 9 | Dismantling of timber fillets rails, posts rafter purlins etc under 40 Sqcm in section in any position in framed work, complete all as specified and as directed. |
| 10 | S&F second class hardwood plain fillets square, rectangular in section exc 13 Sqcm & not exc 25 Sqcm, complete all as specified and as directed. |
| 11 | S&F second class hardwood plain fillets square, rectangular in section exc 6 Sqcm and not exc 13 Sqcm, complete all as specified and as directed. |
| 12 | Dismantling boarding, any description, fixed in any position with nails, complete all as specified and as directed. |
| 13 | M&L, for weather boarding of 2nd class softwood, clean sawn, plain, 20 mm thick or feather edged 15 mm to 20 mm thick and fixed with 30 mm laps,complete all as specified and as directed. |
| 14 | S & F in repair aluminium composite panel clading of approved Make- Alstone/AucomatlAlpolic (as per technical specification) including necessary aluminium frame work either curved or straight or circular in plan. The aluminium composite panel shall be of 3mm thick thermoplastic core of anti- oxidant LDPE+HDP (Virigin Core) sanwitched between 2 layers each of 0.5 mm thick aluminium alloy sheet (alloy grade 1100 of ASTM B- 209) making a total pannel thicknes of 5 to 6 mm. The surface finish shall be PVDF coat of 30 micron over a base polyster coat on top and services coat on the reverse witth chrome/ alkyd of 6 to 7 microns coating shall conforme to ASTM D- 2244 -93 and ASTM D 523- 89 for colour retention and colk reesistante ACP shall be fixed on specially design aluminium frame work as per manufacturer's instractions with Horizontal and vertical members of extruded aluminium section of size 25 x 38 x1.6 mm sheet to supplyed in width of 1220mm and as per specification including stanless steel fastening system making grooves applying non staining and non streaking wather sealent ( Alstone WS- 600/900 of equivalent as approvd), complete all as specified and as directed. |
| 15 | S & F 8 to 10mm thick 2nd class soft wood Planed one side & edges tongued and grooved or rebated, with nails in flooring and skirting, complete all as specified and as directed. |
| 16 | S&F facia boarding of 2nd class soft wood planed one side with but joints 20mm thick and champhered one side and the boarding is matched, complete all as specified and as directed. |
| 17 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and as directed. |
| 18 | M&L for 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in floor sub base, complete all as specified and as directed. |
| 19 | M&L for 25mm thick PCC 1:2:4 type B-O (using 12.5 graded aggregate) as in floors finished even and fair, complete all as specified and as directed. |
| 20 | M & L for vitrified ceramic tiles 10 mm thick light shade (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM (1:6), complete all as specified and as directed. |
| 21 | M & L Non-skid ceramic tiles 7 to 8mm thick area of each tiles exc 0.18m and n.exc 0.38 Sqm in floor etc, Incl screed bed 15 mm thick in CM (1:6), complete all as specified and as directed. |
| 22 | Dismantling floor hearth wall tilling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish of the permishes, complete all as specified and as directed. |
| 23 | S&F glazed ceramic coloured tiles in verticles surfaces of size 600x300x7/9 mm thick set and jointed in neat cement slurryy and pointed white or coloured cement to match tile surface over and including 10 mm thick plaster in cement and sand mortar 1:4, complete all as specified and as directed. |
| 24 | M&L 75mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection and similar works including finishing the surface of concrete topping even & fair, without using extra cement, complete all as specified and as directed. |
| 25 | Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each and removal from site, complete all as specified and as directed. |
| 26 | Taking down chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm each with shutters (W/out taking off shutters from the frames), complete all as specified and as directed. |
| 27 | Taking down of Shutters of any description n exc 1 sqm each, complete all as specified and as directed. |
| 28 | Taking down of Shutters of any description exc 1 sqm but n exc 2 sqm each, complete all as specified and as directed. |
| 29 | S&F 2nd Class Soft wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered put together with glue pinned at joints, complete all as specified and as directed. |
| 30 | S&F 2nd class soft wood 35mm thick factory made panelled shutters with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS-1003 (Pt-I) kiln seasoned and chemically pressure treated. |
| 31 | S&F 35 mm thick glazed skeleton shutters open rebated and prepared to receive guage etc (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc and fitted to chowkats |
| 32 | S&F 2nd class 30 mm thick soft wood (Kail) glazed skeleton shutters open rebated and prepared to receive guage etc (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc and fitted to chowkats size of members of shutters as specified in SSR Part - I section 8 Clause 8.23 (b) for windows, ventilators etc are provided with stiles and rails, complete all as specified and as directed. |
| 33 | S&F pvc door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplied and fitted in openings as per specification and drawing shown in SSR Part II, complete all as specified and as directed. |
| 34 | S&F factory made solid PVC moulded door shutter 28 to 30 mm thk (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channe having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & and as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as shown in drawing of relevant item in MES, schedule Part II, 2010, complete all as specified and as directed. |
| 35 | MS Cold rolled Butt hinges medium weight 100 mm long, complete all as specified and as directed. |
| 36 | MS Cold rolled Butt hinges medium weight 75 mm long, complete all as specified and as directed. |
| 37 | S&F 300mm long Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy, complete all as specified and as directed. |
| 38 | S&F 300 mm size mild steel ordinary rat rail rod pattern springs including roller and roller plate, complete all as specified and as directed. |
| 39 | S&F 200mm long Anodised Aluminium tower bolt, complete all as specified and as directed. |
| 40 | S&F 100mm long Anodised Aluminium tower bolt, complete all as specified and as directed. |
| 41 | S&F 150mm long extruded aluminium alloy handle, complete all as specified and as directed. |
| 42 | S&F 100mm long extruded aluminium alloy handle, complete all as specified and as directed. |
| 43 | S&F galvanised mild steel wire cloth 0.46 mm nominal dia of wire and avarage width of aparture 1.18 mm and fixed with tinned tacks to galvanised wire stapple, complete all as specified and as directed. |
| 44 | S&F Sheet glass ordinary quality & glazing with oil putty in square n-exc. 0.5 sqm in each pane 3mm thick, complete all as specified and as directed. |
| 45 | M&L for applying two coats of synthetic enamel paint over a coat of pink primer including preparation of new wooden or wood based surfaces over 10cm width or girth etc, complete all as specified and as directed. |
| 46 | S&F in repairs curtain rails , anodised aluminium alloy with fixing brackets , stops, rollers etc, complete all as specified and as directed. |
| 47 | S&F for Aluminium anodised Brackets fixed in repair, complete all as specified and as directed. |
| 48 | Demolition of brick work, PCC block masonary, stone masonary or boulder masonry built in cement mortar, complete all as specified and as directed. |
| 49 | M & L for brick work with sub class 'B' bricks (old sizes) straight or curved on plan exceeding 6 mtr mean radius built in CM (1:6), complete all as specified and as directed. |
| 50 | M&L Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6), complete all as specified and as directed. |
| 51 | Taking down cement or cement lime plaster, on brick or stone walls/ceiling etc, including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed. |
| 52 | M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and as directed. |
| 53 | M&L for preparation of new surfaces of walls and applying two coats of Oil bound distemper over a coat of priming on plastered and other surfaces with alkali resistant priming paint, complete all as specified and as directed. |
| 54 | M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint, white or tinted, complete all as specified and as directed. |
| 55 | M&L for preparation of old treated surface of brick/stone work, concrete plastered or unplastered surface and applying one coat of cement base paint on walls, complete all as specified and as directed. |
| 56 | All as per item No. 55 above but one coat of oil bound distemper on walls, complete all as specified and as directed. |
| 57 | Demolition of reinforced Concrete of any description and in any position not otherwise specifically provided for, complete all as specified and as directed. |
| 58 | M&L for mild steel TMT Bars 10mm dia and over, quality, cut to length, bent to shape required including cranking, bending and binding with mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and as directed. |
| 59 | M & L precast RCC man holes cover in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate Providing precast ce- ment concrete in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, complete all as specified and as directed. |
| 60 | S&F vitreous China Wash Basin white, flat back size 550x400 mm including bracket, waste coupling, waste pipe, complete all as specified and as directed. |
| 61 | S&F 600 x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC buillding board or comercial ply wood and fixed to wooden plugs with chromium plated brass & screws and cup washers, complete all as specified and as directed. |
| 62 | S&F PVC (SWR) floor trap plain with grating including jointing with solvent cement 75 mm bore, complete all as specified and as directed. |
| 63 | S&F for PVC (SWR) bend with access door inluding jointing with solvent cement 75 mm bore, complete all as specified and as directed. |
| 64 | S&F for PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors for 110 mm bore pipe, complete all as specified and as directed. |
| 65 | S&F 15mm bore Bib taps, cast copper alloy, with crutch or butterfly handle screwed down, screwed for iron or brass ferrule and fixed but fency type, complete all as specified and as directed. |
| 66 | S&F in repairs pillar taps, 15 mm dia cast copper alloy fency type with capstan heads, chromium plated. screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks & fly nuts screwed for iron pipe, complete all as specified and as directed. |
| 67 | S&F PVC connection 15 mm size with PTMT nuts of length 600 mm, complete all as specified and as directed. |
| 68 | S&F 15mm dia angle stop valve of CP any colour high pressure screwed for for iron pipe and fixed, complete all as specified and as directed. |
| 69 | S&F 1000 ltr capacity rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all all as specified in SSR part -I, complete all as specified and as directed. |
| 70 | Taking up or down 15mm steel tubing and connections, including cleaning for refixing or removal to store, complete all as specified and as directed. |
| 71 | M&L for GI tubing medium grade galvanised with all fittings complete to wall, ceilings or laid on roof top all as specified and directed for 15 mm bore, complete all as specified and as directed. |
| 72 | S & F gun metal globe or gate valve with iron wheel screwed both ends for iron pipe of 15 mm dia, complete all as specified and as directed. |
| 73 | S&F 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . /25mm-455gms/ 40mm - 690 gms), complete all as specified and as directed. |
| 74 | S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed. |
| 75 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome, complete all as specified and as directed. |
| 76 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in any type of soil, complete all as specified and as directed. |
| 77 | M& L for PCC 1:4:8 Type D-2 (using 40 mm graded aggregate) as in foundation ,filling and mass concrete, complete all as specified and as directed. |
| 78 | Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc. |
| 79 | M&L for point wiring for using 1.5Sqm nominal cross section area copper conductor multistandard PVC unsheathed, FRLS cable in and including using pvc casing caping not less than 25mm size and fitings including pvc box with suitable size of pvc sheet for top cover(ISI marked) fitted with chromium plated steel screws and washer and 1.5 Sqmm nominal cross section area multistandared copper conductor FRLS green pvc insulated unsheathed earth wire and conecting to earth dolly using color code as per IS including terminal boxes suitable for fixing socket and switches all as specified as directed by engineer in charge. |
| 80 | (a) One light point/fan point/Ex fan point controlled by one 5 Amps switch one way |
| 81 | (c) One 3 pin 5 Amp switch socket outlet on independent board |
| 82 | (d) One 3 pin 5 Amp switch socket outlet on same board with accessories |
| 83 | M&L for point wiring for using 2.5 Sqm nominal cross section area copper conductor multistandard PVC unsheathed, FRLS cable in and including using pvc casing caping not less than 25mm size and fitings including pvc box with suitable size of pvc sheet for top cover(ISI marked) fitted with chromium plated steel screws and washer and 2.5 Sqmm nominal cross section area multistandared copper conductor FRLS green pvc insulated unsheathed earth wire and conecting to earth dolly using color code as per IS including terminal boxes suitable for fixing socket and switches all as specified as directed by engineer in charge. |
| 84 | S&F switch piano Flush type, single pole, one way 5 amp 240 volts, complete all as specified and as directed. |
| 85 | S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type, complete all as specified and as directed. |
| 86 | S&F Switch socket combination 2 in1, 3 pin,5 and 15Amp flush type,universal complete all as specified and as directed. |
| 87 | Supply and fix ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body, complete all as specified and as directed. |
| 88 | S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting, complete all as specified and as directed. |
| 89 | S&F in repairs Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 12 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires,complete all as specified and as directed. |
| 90 | S & F in repairs MCB, SPN 63 Amps 240 Volts C curve, complete all as specified and as directed. |
| 91 | S & F MCB Single pole 6-32A Amps 240 Volts C Curve, complete all as specified and as directed. |
| 92 | Supply and fixing LED lights fittings 1x20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with two core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed. |
| 93 | S&F LED inverter Bulb 12 Watt, complete all as specified and as directed. |
| 94 | S&F led luminaire comprising of high brightness LEDs 9/10W LED, IP 65/66, complete all as specified and as directed. |
| 95 | S&F MCB, DB TPN double door, IP-43, 8 way with 200 A rated bus bar having earth terminal including MCCB 250 Amps as incommer and mcb sp as out going for DB SPN complete in all respect Concealed in wall including making electrical incoming and outgoing connection with legs/thimbles, complete all as specified and as directed. |
| 96 | M & L sub main wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia PVC conduit/casing caping, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board and testing on completion etc complete all as directed. Note: Two runs of 6 sqmm and one run of 6 sqmm cable and one run of casing capping shall be measured as one RM |
| 97 | S & F Bulkhead luminaire comprising of high brightness LEDs 9/10W LED, IP-65/66, complete all as specified and as directed. |
| 98 | S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm, complete all as specfied and as directed. |
| 99 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet, complete all as specified and as directed. |
| 100 | M&L in repairs for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is ilnclusive of necessary earth work, RFR and removal etc |
| 101 | Supply ,Laying ,connecting/ Jointing,charging, testing and commissioning LT cable electric, XLPE insulated, armoured, PVC sheathed, heavy duty, electric cable 1100 Volt grade with stranded aluminum conductor conforming to IS :7098, laid in trenches/ducts/fixed to wall /roofs/ poles all as specified of size 3.5 Core 50 sq mm . including Taking out old unservicable cable from any space, complete all as specified and as directed. |
| 102 | Excavation in trenches n exc 1.5 m wide & n exc 1.5 mtr deep in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes etc not exc 10 sqm on plan and n exc 1.5 mtr in depth and getting out of soft/lose soil for taking out pipe & laying of pipe & getting out for diverting of CI pipe line, complete all as specified and as directed. |
| 103 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm depth in soil, complete all as specified and as directed. |
| 104 | Removing excavated material (soil ) n.exc 50m and depositing where directed at a level n.exc. 1.5 mtr above the starting point, complete all as specified and as directed. |
| 105 | M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable, complete all as specified and as directed. |
| 106 | M&L for Sub class \\"B\\" bricks laid dry width wise across the line of cable in trenchs as cable protection, complete all as specified and as directed. |
| 107 | S&F Gl Tubing light grade 40mm dia with all fitting; laid in trenches, complete all as specified and as directed. |
| 108 | Note:- Schedule of credit Rs 1,15,849.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents. Please Enable Macros to View BoQ information |