| 1 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed. |
| 2 | Taking down chowkats or frames exc 1.5 Sqm and n.exc 4 Sqm (without taking off shutter from the frames) and removal from site complete all as directed. |
| 3 | All as Sch Á' item No 2 here-in above but n.exc 1.5 Sqm each.complete all as directed. |
| 4 | Taking down shutters of any description exc 1 Sqm and n.exc 2 Sqm each complete all as directed. |
| 5 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises.complete all as directed. |
| 6 | Taking down cement plaster/terrezzo cast in situ of any description on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etc.complete all as directed. |
| 7 | Demolition of concrete in ground floor and pavings n.exc 15cm thick (un reinforced).complete all as directed. |
| 8 | Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for complete all as directed. |
| 9 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all asas directed. |
| 10 | Demolition of precast concrete block/brick walling built in cement mortar etc complete all as as directed. |
| 11 | Dismantling old PGI/CGI/AC sheeting any gauge, thickness, including Nainital. Sikkim or similar pattern roof/facia etc complete complete all as as directed. |
| 12 | Hacking out of old broken glass any thickness size quality or description from metal frame including punching or drilling out old glazing pins complete all as as directed. |
| 13 | M&L for 2nd class hard wood plain solid straight chowkats and frames wrought framed rebated on the solid rounded on chamfered put together with glue pinned and joints complete all as specified and directed. |
| 14 | M&L for factory made 2nd calss hardwood plain, framed, panelled shutters 35 mm thick (any number of panels) , with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats complete all as specified and directed. |
| 15 | S&F 2nd class hardwood, glazed and skelton shutters 30 mm thick open rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I Section8, Clause 8.20 (a) supplied and fitted to chowkats omplete all as specified and directed. |
| 16 | S&F flush shutters 35 mm thick, solid core construction, with particle board core commercial type on one side and one face covered with decorative face veneer wtih lipping/frame to match omplete all as specified and directed. |
| 17 | S&F Solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying & fixing in opening as per specification and drawing complete all as specified and directed. |
| 18 | S&F 30mm thick (style thickness) factory made solid panel PVC door shutter consisting of frame made out of mild steel tubes for top and bottom rails, mild steel frame shall be covered with heat moulded single side prelam PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and single side prelam PVC sheet for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail on either side & as gap insert for toprail and bottom rail, panelling of both side prelam PVC sheet to be fitted in the mild steel frame welded /sealed to the stiles and rails with uitable PVC sheet beading and jointed together with solvent cement as per specification and drawing given on MES Schedule Part-II (2020) complete all as pecified and directed. |
| 19 | S&F 250mm long aluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section complete all as specified and directed. |
| 20 | S&F for 150 mm size aluminium anodised cast type handles complete all as specified and directed. |
| 21 | S&F for 100 mm size mild steel pressed handles, oval types, stove enameled black complete all as specified and directed.. |
| 22 | S&F of 150mm long aluminium anodised,barrel tower bolt of extruded section.complete all as specified and directed. |
| 23 | S&F 100mm long aluminium anodised,barrel tower bolt of extruded section.complete all as specified and directed. |
| 24 | S&F 100mm size mild steel butt hinges medium weight. .complete all as specified and directed. |
| 25 | S&F 75mm size mild steel butt hinges medium weight..complete all as specified and directed. |
| 26 | S&F continuous ( piano) hinges with 30 mm width of flaps ( when open), mild steel bright finish or electrogalvanised fixed with stainless steel screws complete all as specified and directed. |
| 27 | S&F in repairs of 18 / 19mm thick particle board medium density flat pressed,single layer type with BWR type adhesive fixed with screws to timber frame work as in repair including teak wood lipping 6mm thick all round fixed with nails complete all as specified and directed. |
| 28 | M&L for PCC (1:3:6), type C-1 (using 20mm graded stone aggregate) as in coping complete all as specified & as directed. |
| 29 | Taking up or down 20mm bore steel water tubings and fittings etc complete and making good disturbed surfaces of walls/ceilings or floor etc complete all as specified and as directed. |
| 30 | Taking up or down 25mm bore steel water tubings and fittings etc complete and making good disturbed surfaces of walls/ceilings or floor etc complete all as specified and as directed. |
| 31 | Supplying and laying of 20mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed. |
| 32 | M&L for 25mm steel tubing medium grade,galvanised fitting fixed complete to walls and ceiling or floor complete all as specified and as directed. |
| 33 | M&L for Cutting chases, pinning in, making good to facing where required and pointing in CM 1:3 for concealed water tubing conduit wiring etc and making good, cutting n.exc 10cm girth as in stone or concrete block walls complete all as specified and directed. |
| 34 | M&L for glazed coloured ceramic tiles (350x250x7mm thick/450x300x7mm thick) on vertical surfaces such as skirting/dado set and jointed in neat cement slurry pointed in white or coloured cement to match the colour over and including 10 mm thick rendering in CM (1:4) as in wall complete all as specified and directed. |
| 35 | M&L for Non - skid colured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20mm thick screed bed in cement mortar (1:6) for laying floor finishes complete all as specified and directed. |
| 36 | M&L for Light shade virtified tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour over ad including 20mm thick screed bed in cement mortar (1:6) for laying floor/roof finishes complete all as specified and directed. |
| 37 | All as per Sch Ä' item No 36 here-in-above but in skirting with 10 mm thick rendering as coat in CM ( 1:4) complete all as specified and directed. |
| 38 | M&L for 25 mm thick PCC (1:2:4) type B1 ( 20mm graded stone aggregate) , finished concrete surfaces even and rough to receive floor finishes complete all as specified and directed. |
| 39 | M&L for 75mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in plinth protection/path etc finishing the surface even & smooth without using extra cement complete all as specified and directed. |
| 40 | M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in surface channels/drain including forming fair finished to drain channel..complete all as specified and directed. |
| 41 | M&L for 15 mm thick rendering on fair faces of brick or concrete surfaces in cement mortar (1:6) finished even & smooth without using extra cement complete all as specified and directed. |
| 42 | M&L for 20mm thick rendering two layer (10mm thick each layer) in cement mortar 1:4 and top layer mixed with using WPC @ of 3% by weight of cement in finishing layer on brick or concrete surfaces finished even & smooth (WPC for finishing layer will be paid seperately as supply only)..complete all as specified and directed.Note: WPC will be measured and paid separetly as supply only. |
| 43 | M&L for 5mm thick in CM 1:3 in ceiling finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 44 | Supply only liquid water proofing compound complete all as specified and directed. |
| 45 | M&L for applying two coat of white wash including preparation of new or previously untreated surfaces of walls complete all as specified and directed. |
| 46 | M&L for applying two coat of white washing including preparation of new or previously untreated surface of ceiling complete all as specified and directed. |
| 47 | M&L for preparation of surface and applying two coats of Oil emulsion distemper of new or previously untreated surfaces of walls complete all as specified and directed. |
| 48 | M&L for preparation of surface and applying two coats of Oil emulsion distemper including complete removal of existing treatment on wall complete all as specified and directed. |
| 49 | M&L for applying wall care putty of 3 mm thick in two layers (1.5mm each layer) complete all as specified and directed. |
| 50 | S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints,fixed to wall/laid under hoor complete all as specified and directed. |
| 51 | S&F 110mm bore PVC (SWR) bends any radius fixed to PVC Pipes/Steel Gutters etc complete all as specified and directed. |
| 52 | S&F110mm bore PVC (SWR) junction single (single tee) equal or unequal, dia of pipe 110 mm complete all as specified and directed. |
| 53 | S&F for 75 mm bore PVC (SWR) pipe of pressure rating 4kgf/cm2 single socketed in any length with rubber ring joints jointing with adhesive fixed in repair to wall/laid in hoor complete all as specified and directed. |
| 54 | S&F 75 mm bore PVC (SWR) bends in any radius complete all as specified and directed. |
| 55 | S&F 75mm bore PVC (SWR) junction single (single tee) equal or unequal complete all as specified and directed. |
| 56 | M&L in repairs for PVC floor/Nahani trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B1(diameter of outlet 100mm) as in repair.complete all as specified and directed. |
| 57 | M&L for pre cast cement concrete hollow block masonery exc 10cm in width and setting in CM 1:6 (Type 1:3:6 using 16mm graded aggregate).complete all as specified and directed. |
| 58 | Excavating in post holes (or similar holes) each n.exc 0.5 Cum getting out and removing surplus soil to a distance n exc 50m and making good surfaces in soft/loose soil complete all as specified and directed. |
| 59 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregates on in foundation, filling and mass concrete complete all as specified and directed. |
| 60 | S&F Rolled sections Fe 410-w (grade E-250) quality-A as in main and cross beams, hip and jack rafters;purlins where connected to common rafters and running rails and guides for sliding doors;fixed with angle cleats or other connecting plates complete all as specified and directed. |
| 61 | S&F framed work such as grills, gratings etc, with ends of bars, shoulded and/or riveted or forged in spikes, framed guard bars, walk ways, railings, frame work of water tanks and similar works conforming to Fe 290, Gde-E-165 complete all as specified and directed. |
| 62 | M&L for pre-painted galvalume aluminium zinc coating GI based corrugated/Zigzag/Trapezoidal corrugation steel sheet 0.50mm thick of an colour having tensile strength of 550 mpa as in roof covering fixed with self tapping screws/L type or J hooks complete all as specified and directed. |
| 63 | M&L for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering fixed with self tapping screws /L type or J hooks complete all as specified and directed. |
| 64 | S&Fof 3mm thick sheet glass panes ordinary quality n.exc 0.5sqm each fixed to steel frame complete with oil putty in square including steel pin complete all as specified and directed. |
| 65 | S&F 3mm thick sheet glass Figured glass, pin head type and glazing with n.exc 0.5sqm each fixed to steel frame complete with oil putty in square including steel pin complete all as specified and directed. |
| 66 | M&L for two coats of synthetic enamel painting to new steel surface over a coat of red oxide primer including preparation of surfaces area exc 10cm width & girth complete all as specified and directed. |
| 67 | M&L for prepartation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and apply one coat of synthetic enamel paint complete all as specified and directed. |
| 68 | M&L for two coats of synthetic enamel painting to new wooden surfaces over a coat of pink primer including preparation of surfaces area exc 10cm width & girth complete all as specified and directed. |
| 69 | M& L for prepartation of old painted wooden surfaces of any description, over 10 cm width or girth, not otherwise described and apply one coat of synthetic enamel paint complete all as specified and directed. |
| 70 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks to wooden/steel shutter,or galvanised wire staples complete all as specified and directed.. |
| 71 | S&F for magnetic cupboard catcher made of high quality stainless steel complete all as specified and directed |
| 72 | Dismantling timber scantlings 40 Sqcm and over in section, in unframed work in any position complete all as specified and directed |
| 73 | S&F 2nd class hard wood clean sawn timber fixed in scantling complete all as specified and directed |
| 74 | S&F in repairs 25mm thick block boards, grade 2 quality, interior grade, decorative type with decorative face veneer on one face, fixed with screws to timber frame-work complete all as specified and directed. |
| 75 | S&F of 50mm size mild steel butt hinges medium weight complete all as specified and directed. |
| 76 | S&F for 75mm size brass handles (decorative type) cast type polished bright complete all as specified and directed. |
| 77 | S&F Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified & as directed. |
| 78 | Dismantling wall and ceiling board (fibre pulp, insulation etc) or insulation boards any thickness including cover fillets complete all as specified & as directed. |
| 79 | S&F powder coated GI grid frame work for false ceiling comprising of the following sections for making partition of 600x600mm size fixed to walls with rawl plugs and screws and hanged to roof with and including 6 mm dia GI wire suspender of suitable length and buterfly clips, size of main tee shall be 23mmx 28mmx 0.30mm thick, cross tee shall be 24x 23x .30 mm thick and wall angle shall be 20mmx20mmx0.30mm thick complete all as specified and directed. |
| 80 | S&F for 4mm thick Non asbestos fibre cement building board (E-board) of approved texture for insulation and acoustic purpose of size 595x595 mm size fixed with staples on snap grid as in ceiling with and including dusting of surface and applying one coats of oil emulsion distemper over a coat of primer including preparation of surfaces complete all as specified and directed. |
| 81 | S&F 5-6mm thick PVC ceiling/wall panels of interlocking types, width 250/255 mm with lamination design and exc 60% of PVC content including necessary H-joints, internal/external corner trim, coner cove,F/J edge trims where required fixed with hidden screws incl steel/wooden frame work complete all as specified and as directed. |
| 82 | Supply, Fabrication and fixing in repairs powder coated aluminium sliding window (three track) with aluminium frame of section 62.30 x 44.50 x 1.5 mm with shutter stiles rail of aluminium section of size 47.62 x 44.45 x 1.5 mm thick including jointing cleat for fixing binder hardware glazing clips rubber packing for air lock purpose anodized aluminuim strip bearing screw etc for fixing glass pans in frame shutter covered with fully selected quality glass 4mm thick tinted/plain glass with rubber packing and locking arrangement and fly proof shutter of same size with aluminium wire mesh complete all as spcified and as directed. |
| 83 | Supply , Fabrication and fixing in repairs powder coated aluminium openable/fix type window/ventilator with aluminium frame of section 62.30 x 44.50 x 1.5 mm with shutter stiles rail of aluminum section of size 47.62 x 44.45 x 1.5 mm thick includiing jointing cleat for fixing binder hardware glazing clips rubber packing for air lock purpose anodized aluminium strip bearing screw etc for fixing glass pans in frame shutter covered with fully selected quality Figured glass, pin head type 4mm thick including louvered as directed with rubber packing and locking arrangement complete all as spcified and as directed. |
| 84 | M&L for water proofing treatment by applying two coats of DR Fixit Fast Flex 113 of DR Fixit or equivalent make for sunken portion treatment complete all as per manufacturer instruction and as directed. |
| 85 | M&L for PCC (1:5:10) type E2 (using 40mm graded aggregate) as in filling & mass concrete complete all as specified and directed. |
| 86 | M&L for 15 mm thick rendering in CM 1:3 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 87 | S&F steel water tubing 50 mm dia 'medium grade', galvanised, with all fitting and fixed complete to as in spout pipe in sunken portion,fixed in repairs complete all as specified and directed. |
| 88 | M&L for up rooting of plant/bushes from walls of bldgs up to extranded root and spraying of Muriatic acid required quantity complete from any location of bldg up to four storeis and making good the surface with cement mortar (1:4) or cement concrete type B-0 (1:2:4) using 12.5mm graded aggregate upto 4th floor complete all as specified and as directed. (Note:- Necessary scaffolding shall deemed to be included in this item) Please Enable Macros to View BoQ information |
| 89 | M&L for up rooting of plant/bushes from walls of bldgs up to extranded root and spraying of Muriatic acid required quantity complete from any location of bldg up to four storeis and making good the surface with cement mortar (1:4) or cement concrete type B-0 (1:2:4) using 12.5mm graded aggregate upto 4th floor complete all as specified and as directed. (Note:- Necessary scaffolding shall deemed to be included in this item) Please Enable Macros to View BoQ information |