| 1 | Demolition of brick work built in cement mortar of any description and position, complete all as specified and directed. |
| 2 | Demolition of cement concrete (un-reinforced) in Ground floors and paving not exe 15cm thickness (below or above ground level) including removal of rubbish out side complex (MOD land), complete all as specified and directed. |
| 3 | Dismantling of stone slabs and tiles of any description or thickness in floors, walls, aprons etc laid bedded and pointed in any type of mortar and removal of old tiles from premises complete all as specified and directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 5 | Taking down chowkhat or frames exc. 1.5 Sqm and not exc 4 Sqm each with shutters (without taking off shutters from frames) complete all as specified and directed. |
| 6 | Taking down chowkhat or frames not exc. 1.5 Sqm each with shutters (without taking off shutters from frames) complete all as specified and directed. |
| 7 | Taking down cement plaster, terrazzo, grit plaster dado in any thickness from brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish, vegetation etc outside complex (MOD land) complete all as specified and directed. |
| 8 | M& L for 1mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required. complete all as specified. |
| 9 | M&L for MS angle for hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, steel chowkhat for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof, framing for ceiling etc., including securing bolts; complete all as specified. |
| 10 | S&F for 100mm long medium weight butt hinges, cold rolled mild steel, and fixed/ welded to chowkhat complete all as specified and directed. |
| 11 | S&F for 250mm long mild steel sliding door bolts, plate type, with bright bolt not less than 12mm dia on staple plate and fixed or welded, complete all as specified and directed. |
| 12 | S&F for 150mm long Mild steel, semi-barrel tower bolt, open cover, with sheet pressed barrel, stove enamelled black with bright bolt and fixed, complete all as specified and directed. |
| 13 | S & F in repairs stainless steel Curtain Rod 25 mm dia with holders fixed to wall with finials and bracket etc. complete all as specified and as directed. |
| 14 | M&L for Box type steel window 1.25mm thick made of ERW tube P- Section of size 60x25mm double rebated outer frame comprise of gauzed skeleton shutter (two gauged shutters and two glazed of ERW tube P- section size 50 X 20 mm and 1mm thick, one/two numbers Openable leaf consisting of two number sash bar of T- section 20mm X 30mm welded to frame with one number vertical mullion of ERW box type T- section of size 60X25 mm and 1.25 mm thick and FI 2 mm thick welded/ screwed to frame for fixing of glass incl fittings and fixture like handle, Tower bolts, stopper, cleat pintal hings and including following (a) Holdfast 150mm long of 120mmx 3mm made to shape 04 Nos per window. (b) Handle of Z section 20mmx25mm,100mm long stopper 01 Nos per leaf. (c) 4mm thick sheet glass pans on glazed shutters. (d) 0.35mm thick SS wire mesh on gauged shutters. etc complete all as specified and directed. |
| 15 | M&L for 2 coat of synthetic enamel paint over a coat of primer on steel surface complete all as specified and directed. |
| 16 | M&L for Brick work with sub class 'B' bricks straight or curved on plan to any radius built in CM 1:6 complete all as specified and directed. |
| 17 | Description all as per item no 16.00 above but except bricks. |
| 18 | M&L for brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4,complete all as specified and directed. |
| 19 | M&L for mild steel TMT bars of 10 mm dia and over cut to length bent to shape required including cranking, bending etc. and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 20 | Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed. |
| 21 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide complete all as specified and directed. |
| 22 | M&L for RCC (1:1 1/2:3) Type A (using 20mm graded stone aggregate) as in Chajjas deck slabs and in shelves and the like including dismantling of existing Chajjas complete all as specified and directed. |
| 23 | Supply only liquid water proofing compound complete all as specified and directed. |
| 24 | M & L 16-18 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.in over and incl 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite slab , notching, moulding and polishing, complete all as specified and directed. |
| 25 | M & L for Machine cut kota stone slab flooring 18-20mm thick laid over & including15mm thick cement screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 26 | M&L for 75mm thick PCC (1:3:6) Type C-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed. |
| 27 | M & L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 grey cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern (groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove) complete including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete. |
| 28 | M&L Rendering 12 mm thick in cement mortar 1:6 on fair face of brick work/ concrete surfaces (either surfaces) and finished even and smooth without using extra cement. |
| 29 | M&L Rendering 15 mm thick in cement mortar 1:4 on fair face of brick work/ concrete surfaces with water proofing admixture finished even and smooth without using extra cement |
| 30 | M & L for Coloured Chequered cement concrete tiles 30cm x 30cm x 20-22mm thick, set, jointed and pointed in neat cement slurry over & including15mm thick screed bed in CM 1:6 including dismantling of old tiles etc. |
| 31 | M&L Cement concrete 1:2:4 type B0 (using 12.5mm graded crushed stone agg) as in coping,incl demolition of existing PCC complete all as specified and directed |
| 32 | M & L for preparation of new plastered surfaces of internal wall/ceiling and applying 2 coats of oil bound distemper over and including 2mm thick wall care putty and coat of primer complete all as specified and as directed. |
| 33 | M & L for preparation of old treated plastered surfaces of internal wall/ceiling and applying one coats of oil bound distemper including scraping old finish and filling the depressions with putty, complete all as specified and as directed. |
| 34 | M & L for preparation of new plaster external wall and ceiling surfaces of and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 liter/ 10 sqm over and including 1mm thick wall care putty complete all as specified and as directed. |
| 35 | M & L for preparation of new plaster external wall and ceiling surfaces of and applying one coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/liter and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 liter/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over and including 1mm thick wall care putty complete all as specified and as directed. |
| 36 | M&L 12 mm thick white colour GRG (Glass Fiber Reinforced Gypsum) Semi Perforated false Ceiling Tiles, Micro Tegular & Tegular edged, Size 595mm X 595mm, Fire Resistance BS-476-4:1970 (Certified), Humidity Resistance (RH) (Certified),including necessary GI frame/ GI T , cross , wall angle etc false ceiling grid (Ceiling Suspension System) in High Quality Zinc Coated Galvanized Iron with Pre Painted Hot Pressed White G I Coil. including centre to centre Hangers 6 mm dia. G.I. rod fully threaded (upto 1000mm long) fixed to ms angle grid with galvanised M-6 desh fastener 50 mm long/ clamps including galvanised MS L-type level adjuster 85 x 25 x 25 x 2 mm with Black Silohutte etc including taking down on existing ceiling completed all as specified and directed. (Make : - BSR Calasi Ceilings/ Diamond ceiling and equivalent as approved by GE) |
| 37 | M&L for MS hooks made out of 12mm dia round bar 300mm long made to shape and grouting in the walls with necessary cutting to brick work and filling the gap with PCC (1:2:4) and making good with necessary plaster and 2 coat of Oil bound distemper and 2 coat of synthetic enamel paint on steel surface complete all as specified. |
| 38 | M&L for 3mm dia MS Wire made to shape and cut to length required complete all as specified and directed |
| 39 | S & F Aluminium Composite panel (ACP Sheets colour as approved by GE) of 3 mm thick joint with silicon/adhesive as per manufacture instruction including necessary aluminium framed work as required shape and size by welding etc. fixing to wall/ceiling/ RCC column/boarding/Gates/Name Plates on gates with necessary fixing arrangements upto a height of 10 Mtrs including taking down existing UNSV sheet of any type complete all as specified and as directed. |
| 40 | Excavating in post holes (or similar holes) each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft/ loose soil |
| 41 | S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall / view cutter etc, fixed with self tapping screws with bent to a curve (of any radius as per required) including dismantling asbestos cement sheet in roof coverings ( corrugated , semi corrugated etc.) any gauge, thickness, including , Nainital or similar pattern roof coverings in any pattern & position of roof coverings. Complete all as specified and directed. |
| 42 | S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall etc, fixed with self tapping screws with bent to a curve (of any radius as per required) including dismantling existing sheet in roof coverings of any type (corrugated, semi corrugated etc) any gauge, thickness, including, in any pattern & position, complete all as specified and directed. |
| 43 | Providing and injecting chemical emulsion for Post Constructional Ant termite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per Sqm of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete |
| 44 | Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors |
| 45 | Treating the points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same |
| 46 | M&L for Writing letters or numbers (Block, Roman, Italic or Indian) not exc. 30 cm high (5 Nos ) over and including white colour glazed tiles of size 300x450mm on wall including dismantling of existing tiles complete all as specified and directed. |
| 47 | M&L for plain cement concrete(1:3:6) Type C2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 48 | M&L for plain cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) in surface channels and drains. |
| 49 | Extra for forming fair finished drain or channel 50 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. |
| 50 | S & F Rotational moulded polyethylene water storage tanks 1000 lts capacity, double layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PTMT ball valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed including taking out existing unserviceable overhead tank of any description complete. |
| 51 | S & F Rotational moulded polyethylene water storage tanks 500 lts capacity, double layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PTMT ball valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed including taking out existing unserviceable overhead tank of any description complete. |
| 52 | S & F for PVC hollow wall panelling 7 to 8 mm thick wood grain teak finished prelaminated inclusive of fixing to wall incl moulding end caps fixed with PVC sleeves and screws as required at site including taking down existing panelling of any type complete all as specified and as directed. Please Enable Macros to View BoQ information |