| 1 | GENERAL SUMMARY |
| 2 | Lump sum price worked out by the contractor against Schedule ‘A’ Part- I (BUILDING WORKS) for the following building works:- |
| 3 | (a) Lump sump amount worked out by the contractor for Design, development of structural drawings as per the architectural drawing Nos CWE/ARCH/33/2025 Sheet No. 1R/2, CWE/ARCH/33/2025 Sheet No. 2R/2 and Construction of Obsn Post at 5000M & 7000M, 2 X rest room with Toilet facility, 2 X OP Post 3 storey, 2 X Staircase (GF) and 2 X Staircase (FF to TF) as per architectural drawings, structural drawing, TD drawings, schedule of finishes & given specifications built in permanent specification with RCC frames construction including ATT, WPT mosquito proofing with OBD finishing ceramic tile flooring, etc complete all as specified and as directed. NOTE:- The structural design and drawing shall be got vetted from any IITs/NITs before execution of work by the contractor. |
| 4 | Lump sum price worked out by the contractor for EXCAVATION AND EARTH WORK as listed in Schedule ‘A’ Part- II (Ref prepriced schedule attached seperately) |
| 5 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part-III (Ref prepriced schedule attached seperately) |
| 6 | Lump sum price worked out by the contractor for ROADS/PATH/CULVERTS WORKS as listed in Schedule ‘A’ Part-IV (Ref prepriced schedule attached seperately) |
| 7 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part- V (Ref prepriced schedule attached seperately) |
| 8 | Lump sum price worked out by the contractor for SECURITY FENCING WORKS as listed in Schedule ‘A’ Part- VI (Ref prepriced schedule attached seperately) |
| 9 | SCH 'A' Pt - VII (MISCELLANEOUS PARTS) |
| 10 | S & F Modular Fan step regulator , 240 Volts 1/2 module complete. with cover plate complete all as specified and directed. |
| 11 | S & F 09 Watt LED bulb with inverter technology inbuilt rechargeable battery and control circuit, battery backup upto 4 hrs in white colour with maximum Lumen output (850 lm) and colour temp 3000 K, complete all as specified and directed. |
| 12 | S & F 1 x 20 Watt LED tube light fitting polycarbonated housing prewired with all accessories and including LED tube rod 20 Watt 4 feet long inlcuding connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable 3 core of size 0.50 Sqmm complete all as specified and directed. |
| 13 | Construction of Septic tank with cover slab of RCC M 25 (Nominal mix ) for 10 User brick work in CM 1:4 ( with top of slab at groung level ) including necessary excavation and earth work in any type of soil,returning filling and disposal of surplus soil as directed, RCC manholes covers with angle iron welded frame complete,vent shaft with cowl, all as shown on Drawing No.Ref TD No -CEBZ/2011/TD-76 dt01 Aug 2011 as sfd & directed. |
| 14 | M&L for soakage well exc in ordanry soil, foundation in PCC 1:3:6, wells of honey combed and solid in M-25 concrete including intercepting chamber screen chamber brickwork in CM 1:4, RCC cover slab in M-25/ RR masonary and filling with brick bats complete of size 1.2m dia x3.0m deep as per drg No. HTD/381 complete all as specified. Please Enable Macros to View BoQ information |