| Sl. No. | Item Description |
| 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l. |
| 2 | Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation frenches within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume). |
| 3 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). |
| 4 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up toplinth level1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishingand reinforcement - All work up to plinth level.1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets,columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering,shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves,chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the costof centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate20 mm nominal size). |
| 9 | providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing with , cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position (including cariage of bars to work site) all complete as per building specification and direction of E/I. TMT Fe 500( onle valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL) |
| 10 | providing Tor steel reinforcement of 10mm,12mm,16mm. dia bars as per approved design and drawing approved design and drawing with , cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position (including cariage of bars to work site) all complete as per building specification and direction of E/I. |
| 11 | (a) 10mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)} |
| 12 | (b) 12mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}) |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 16 | Providing designation 75 B brick work in C.M.(1 :6) in superstructure with approved quality of clean coarse sand of F.M. 2 to2.5 including providing 10 mm thick mortar joints cost of screening materials , scafolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 17 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 18 | Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litres/10 sqm, complete as the direction ofEngineer -in-Charge. |
| 19 | Supply Iron Angles 75x75x8( Gr A) |
| 20 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. |
| 21 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height ofwall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per directionof Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost ofM.S. angle, C.C. blocks shall be paid separate |
| 22 | Carriage of materials from nearest approved sources of supply including loading into trucks and unloading from trucks and stacking properly at work site as directed by the E/I. |
| 23 | Brick lead 8K.M(1K+7P) |
| 24 | sand lead 8K.M. |
| 25 | chips lead 22K.M. |
| 26 | Stone Metal 20 km lead |
| 27 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floor, roof,landings,balconies and access platform |
| 28 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding,top lid shall be screwed into the cast iron/ M.S. sheet box by means of3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing |
| 29 | Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 30 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 gradedstone aggregate 20mm nominal size). |
| 31 | Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 32 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 33 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/l. |
| 34 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/l. |
| 35 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 36 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :11.26.1 25 mm thick |
| 37 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete |
| 38 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :11.55.1 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 39 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. Thetiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easi Glazed Vitrified tiles Matt/Antiskid finish of size11.41A.3.1 Size of Tile 600 x 600 mm |
| 40 | Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shadecomplete. |
| 41 | Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete 8.9.1.2 Granite of any colour and shade |
| 42 | Suppling, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows, skylight, fanlights and celetial windows openings, including wedge over clamps all complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all complete as per building specification and direction of E/l |
| 43 | Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush shutters in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneered of standard make with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l. |
| 44 | Providing & Fixing decorative high pressure laminated sheet of plain /wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conformingto IS : 2046 Type S, including cost of adhesive of approved quality.9.127.1 1.5 mm thick |
| 45 | Supply Factory made prelaminated PVC rigid foam sheet 5mm thick |
| 46 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat/square as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.) |
| 47 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (whereever required) of appropriate dimension, EPDM gasket, hardware, SS304 grade fasteners of minimum 8 mm dia with countersunk headcomprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 1 4 , plastic packers, plasticcaps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof siliconsealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sectionsof uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with/ without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately.Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for(i) Sites with basic wind speed > 45 m/sec as per IS 875 -- Part 3(ii) Sites with structure height more than 20m for all wind speeds Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for rollertrack, wool pile, nylon rollers with SS 304 body. 9.147.A4.1 Using R2 series with frame (70 mm & above) x (40 mm & above) & both glazed and fly screensash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1 . 2 metre). |
| 48 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions ofengineer-in-charge . (Cost of aluminium snap beading shall be paidin basic itemWith float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 49 | Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works |
| 50 | Providing and fixing 2nd class teak wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface12 mm thick |
| 51 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth,which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction ofEngineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) |
| 52 | Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). |
| 53 | Water proofing for Old and New Roof Slab:- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with. brush, roller or spray for water proofing coating as per manufacturer specifications with following steps:(a) surface preparation:-Providing and cleaning of concrete surface to remove dust, oil, grease Including removal of existing loose paint/ coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to Identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt.Ltd. / MYK Schomberg Dr Fixit/Fosroc or equivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150mm X 150 mm fillet of mortar (Cement: sands 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer. Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same withcement slurry including all material, labour, tools complete. (b)1st Coat Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application, 45 gsm of Fibre glass cloth to lay when the first layer is still green 1st coat should be applied @1.50 kg/SqmU/coat. For the AND purpose of measurement the entire treated surface will be measured.\\"(c) 2nd Coat :-To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface, 2nd coat should be applied @0,7 kg/ Sqmt/coat. For the purpose of measurement the entire treated surface will be measured.\\" After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing Brand:- Sika Topseal 109hl /Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2K/MYK Aquafin TG Product Performance- Chemical Base Part A: Acrylic copolymer, Part B: Specially graded cementitious powder- Density 1.6 kg/l (mixed density) at +27°C Tensile Strength -2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength -2 N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength-4 N/mm2 (According to FIP 5.15) (According to ASTM D 2370) Elongation at Break -35% without Fibre Cloth and 20% with Fibre Cloth (According To ASTM D 2370)(d) Protection of treated surface with PCC The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1:1,5:3) with proper slope (1:120) towards the rain outlets in alternate panels of 2 mt x 2mt keeping 6 mm gap between the panel joint. Integral water proofing admixture conforming to IS 2645 @ of 100 ml per bag of cement to be added in the screed concrete (paid separately for this items). All comers shall be just leveled with the screed concrete to ensure smooth discharge VERNMES of water-the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture Insensitive epoxy putty of Sika India Pvt.Ltd./MYK Schomberg / Dr Fixit/Fosroc .For the purpose of measurement the entire treated surface will be measured.\\" (e)Groove of PCC surface should be filled with Polysulphide Sealant. (Paid Separately). Brand- Sika India Pvt.Ltd. /MYK Schomberg/Dr Per M AND Fixit/Fosroc Warranty for five years. |
| 54 | Covering of treated surface with PCC :- Providing 25 mm thick Cement Concrete M20(1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm |
| 55 | Providing and Filling of 6mm thick Groove between 25 mm PCC Panels with Plysulphide Sealant (Poring Grade) as Drawing and Technical specification and direction of E in Charge (with 18% GST) Brand Sika Plysulphide, Fosroc Thioflex 600 Dr. Fixit Pidiseal PS (42P) MYK Seal PS or Equivalent |
| 56 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion(i)single socketed pipes. |
| 57 | 110mm diameter |
| 58 | 75mm dia |
| 59 | Providing and fixing on wall face unplasticised PVC moulded fittings, accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring confirming to I:5382 leaving 10mm gap for thermal expansion. |
| 60 | Coupler 75mm dia |
| 61 | Coupler 110mm dia |
| 62 | Single pushfit Coupler 75mm dia |
| 63 | Single pushfi Coupler 110mm dia |
| 64 | single tee with door 75x75x75mm |
| 65 | single tee with door 110x110x100mm |
| 66 | Single tee without door 75x75x75mm |
| 67 | Single tee without door 110x110x100mm |
| 68 | Bend 87.5° 75mm |
| 69 | Bend 87.5° 110mm |
| 70 | shoe(plain)75mm dia |
| 71 | shoe(plain)110mm dia |
| 72 | Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised PVC rain water pipes by means of 50x50x50mm hard wood plugs,screwed with M.S screws of required length, including cutting brick work and fixing in cement mortar 1:4(1cement:4 coarse sand) and making good the wall etc.complete. |
| 73 | 110mm dia |
| 74 | 75mm dia |
| 75 | Point wiring in PVC conduit, with modular typeswitch:-Wiring for light poinVfan poinUexhaust fan point/call bell point v/ith 1.5 sq.mm FR PVC insulated copper conductor single core in surface/recessed PVC conduit, with modular sw'itch, modular plate suitable GI box etc as requiredGroup C |
| 76 | Power plug widng in PVC conduit (2 x 4 sq. nun) :-Wiriug for light/power plug with 2 x 4 sq.mm FR PVC insulated copperconductor single core cable in surface/recessed PVC conduit, along with 1 No 4 sq.nrm FR PVC insulated copper conductor single core cable for loop carthing etc as required. |
| 77 | Wiring for curcuit submain wiring along with earth wire with the following sizes of PVC insulated copper conductor single core cable in surface of recessed PVC conduit as reqd. |
| 78 | 2x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire |
| 79 | 2x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire |
| 80 | Wiring in existing conduit:- Supplying and drawing following size of FRPVC insulated copper coductor single core cable in existing surface /recessed steel/ PVC conduit including dismantling as required.2x4 sqmm |
| 81 | S/F PVC conduit;-supplying and fixing of following sizes of PVC conduit along with accessories in surface recess inciuding cutting the wall and making good the same in case of recessed conduit as required 20mm |
| 82 | S/f PVC/G.L boxes;- supplying and fixing of following sizes of PVC/G.I box on surface recess withsuitable size of phenolic laminated sheet cover infront including painting etc.as required 75mm x75mmx 50mm deep (4x4) |
| 83 | S/F Modular type switch/ socket :-Supplying and fixing of following modular switch / soket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 84 | 5/6 amps, one why awitch |
| 85 | 15/16 amps,one way awitch |
| 86 | 5/6 amps,3 pin soakat outlat |
| 87 | S/F modular type alectronic fan rogulator :-supplying and fixing stappod type aloctronic fan rregulator on the existing modular plate g awitch box including conneotions but excluding modular plate atc required |
| 88 | S/F modular type blanking plate:- supplying and fixing modular blanking plate on the existing modular plate g switch box excluding modular plate as required. |
| 89 | S/F 20 amps SPN MCB industrial socket:- supplying and fixing 20 amps.240 volts SPN industrial type socket outlet. With 2 pole and earth metal enclosed plug top alongwith 20 amps C curve SP MCB in sheet steel enclossre on surface or in recess with chained metal cover for the socket out let and complete with connectinos testing and commissioning etc. as required |
| 90 | P/F M.V.danger notice plate :-providing and fixing M.V.danger notice plate of 200 mm x 150mm made of mild steel at least 2 mm thick and vitreous enameled white on both sides and with inscription in single red colur on front side as required details of cost four each. |
| 91 | S/F light plug point with modular type accessories:-supplying and fixing suitable GI box with modular plac and cover in front on surface of in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amos modular switch connection painting etc. as required for light plugs to be in non residential buildings. |
| 92 | S/F Power plug point with modular type accessories:-supplying and fixing suitable GI box with modular plac and cover in front on surface of in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch connection painting etc. as required for light plugs to be in non residential buildings. |
| 93 | S/Fceiling rose;- supplying and fixing 2pin 5pin amps ceiling rose on the existing junction box wooen blackincluding connection etc as required. |
| 94 | S/F batten holder ;-supplying and fixing batten angle holder including connection etc as required. |
| 95 | ITC fluorescent fitting directly on surface ;- installation testing and cossissioning of prc wired fluorescent fitting compact fluorescent fitting of all typscompletc with all accessories and tube etc directly wall including connection with 1.5 aq.mm FR PVC insulated copper conductor single core cable and earthing etc as required. |
| 96 | ITC fluorescent fitting with down rods:-Installation testing and commissioning of pre-wired, fluorescent fitting ./ compact fluorescent fitting of all types, complete with all accessories and tube etc. including supplyrng and fixing ball and socket arrangement 2 no. down rods of 20mm dia x 1.6 mm thick steel conduit/Gl pipe upto 30 cm length. , painting and wiring the down and connection with 1.5 sq.mm PVC insulated, copper conductor, single core cable and earthing etc. as required |
| 97 | ITC exhaust fan upto 450mm sweep Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing commissioning etc. as required. |
| 98 | S/F MCCB in cubical panel board :-Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 99 | 25-100 amps, 16 KA, fxed thermal setting |
| 100 | 125 amps, 16 KA, fxed thermal setting |
| 101 | 150/160 amps, 35 KA, fxed thermal setting |
| 102 | 200 amps, 35 KA, fixed thermal setting |
| 103 | SIF S.P. MCB DB :-Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, compiete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door |
| 104 | S/I,'T.P. MCB DB :-Supplying and fixing following way, horizontal type three pole and neutral, lsheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bat earth bar, din bar,interconnections, powder painted including earthing etc. as required. (Butwithout MCB/ RCCB/ Isolator) |
| 105 | 4 way (4 + 12), Dorrble door, Horizontal type |
| 106 | 6 way (4 + 18), Double door, Horizontal type |
| 107 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for.inductive load of following poles in the existing MCB DB complete with connections, esting and commissioningetc. as required. |
| 108 | 6/32 amps, Single pole |
| 109 | 40 amps, TPN |
| 110 | 40 amps, DP |
| 111 | 50/63 amps, DP |
| 112 | S/F four pole MCB isolator :-Supplying and fixing following rating four pole, 415 volts, isolator in theexisting MCB DB complete with connections, testing and commissioning eh. as required. |
| 113 | 40 amps |
| 114 | 80/100 amps |
| 115 | Earthing with copper earth plate 600mrn x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate havinglocking arrangement and watering pipe etc. (with charcoal or coke and salt)asrequted |
| 116 | Supply and laying 8 SWG coppcr wirc at 0,50 metre below ground level for conductor earth electrode, including solding etc. as required |
| 117 | P/p G.I. lightning condutor finial :-Providing and fixing of lighting conductor finial , made of 25mm dia 300mm long , G.I. tube, having single prong at top, with 85mm dia 6mm thick G.I. base plate including holes etc. complete as required. |
| 118 | Pff G.I. lightning conductor tape in horizontal run :-Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required.( for Horizontal run ). |
| 119 | PIF G.I. lightning conductor tape in vertical run :-Providing and fxing G.I. tape 20mm x 3rrm thick on parapet or surface of wall for lightning conductor complete as required.( for Vertical run ). |
| 120 | Laying of one number additional PVC insulated and PVC sheathed/ XLPEpower cable of 1.1 KV grade of size exceeding 185 sq mm but not exceeding 400 sq. mm in the existing RCC/HUME/STONEWAREA4ETAL pipe as required. |
| 121 | PVC/XLPE insulated PVC sheathedheavy duty, armoured electrical cable with aluminiumconductor forworking voltage up to andincluding L100 volts. (Conformsto IS:1554,part-1)50 sq. mm,3.5 core |
| 122 | Supply Installation, testing and commissioning of follwing size ceiling fan 3 Blades confirming to13:374,.2019 including wiring the down rods of Standard length (upto 30cm) with l.Ssq.mm. FR PVC insulated, copper wire Suitable for 230V 50H2, single phase supply etc. complete as required. |
| 123 | 12\\" (300 mm) metal exaust fan |
| 124 | S.I.T.C of floowing rating surface mounted LED tube light fitting suitablefor 230V 50H2, single phase supply etc. complete as required.20122W LED Tube light |
| 125 | 9/1OWatt LED Bulb |
| 126 | S.I.T.C of floowing rating reccess/surface mounted LED round/squareshape Down light luminarie with pressure die cast housing for single phase supply voltage. Luminarie shall be confirm to IS:10322 part-5/section-2 or IEC:62722with all neccssary acc$sories as required15/16 W LED Round Down light |
| 127 | S.I.T.C of floowing rating LED Flood lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC,50Hz. Luminarie shall be confirm tolS:,1,0322part-5/section-5 and shall be complete with all neccssary accessories as required240W LED Flood light |
| 128 | Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of Parry Hindustan or any other I.S.S. approved make with 100 mm H.C.I., \\"p\\" trap 15 litres C.I.. or C. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32 mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I. body brass spindle stop cock of weight not less than 50 grms. 15 mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l.(A) 580 mm long (c) with 10 lit. low level P.V.C. cistern |
| 129 | Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthenware urinal of \\"Hindustan\\" \\" Parry\\" or any other approved I.S.S. make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15 mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grms. , 15 mm P.V.C. alkathene pipe 450 mm long with brass coupling at both ends and doing plumber joints including painting of exposed part with 2 coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/l.(A) Flat back or standing corner ( 600 mm x 350 mm ) |
| 130 | Supply Bib Cock (ISI Marked) |
| 131 | Supply Bib Cock ong Thread (ISI Marked) |
| 132 | Supply Soap Dish |
| 133 | Supply 15mm C.P. extentsion Nipples |
| 134 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/l.(b) Mirrors of 6 mm thick plate glass bevelled edge mirror including C.P brass revolving fittings, 3 mm plywood board and C P hinges to fix with mirror(1)600x450 mm |
| 135 | Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of Parry or Hindustan or any other I.S.S. approved make supported on pointed c.l. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms., 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/l. |
| 136 | Supply 100 mm dia steel jali |
| 137 | Providing and fixing 15 mm dia and 45 cm. long P. V .C connection pipe with heavy quality brass coupling at both ends etc. all complete as per specification and direction of E/l . |
| 138 | Supply 32mm waste pipe for sink or wash basin including PVC waste fitting complete |
| 139 | Providing and fixing Chlorinated polyvinyl chloride (CPVC)pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.m.spacing.This included jointing of the pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. concealed work including cutting chases and making good the walls etc |
| 140 | 20mm nominal outer dia pipes |
| 141 | 25mm nominal outer dia pipes |
| 142 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work |
| 143 | 25mm nominal outer dia pipes |
| 144 | 32mm nominal outer dia pipes |
| 145 | Supplying materials and labours for constructing inspection chamber of designation class 75 B bricks size 750 mm deep, 600 x 450 internal dimension having 250 mm wall thickness in cement mortar ( 1:6 ) including 12 mm cement plaster ( 1:4 ) with punning on inside and cement plaster (1:6 ) with 600 x 475 mm G.I. cover with frame (Weight not less than 36 Kg.) in foundation and refilling all complete as per specification and direction of E/l. |
| 146 | Supply Angular Stop Cock (ong Thread) (ISI Marked) |
| 147 | Supply Polythene water storage tank of ISI mark with cover and locking system |
| 148 | Supply Towel Rail 24\\" |
| 149 | Supply Towel Ring |
| 150 | Providing and fixing N.P/C.P brass/P.V.C porcelain shower rose of 15mm inlet etc. all complete as per specification and direction of E/l(c) 150 mm dia PVC shower . |
| 151 | Providing 12 mm cement plaster (1:3) with clean coarse sand of F.M 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curring, taxes and royalty all complete as per building specification and direction of E/l. |
| 152 | Providing 25 mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layer 19 mm thick (1:2:4) with 12 mm to 6mm size graded stone chips and top layer 6 mm thick (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction of E/l |
| 153 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up toplinth level1:3:6 (1 Cement : 6 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 154 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Medium shade pigment using 50% white cement50% Grey cement |
| 155 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. completeHot finished welded type tubes |
| 156 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing rust , dirt, , scales , smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/l. ( Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification) |
| 157 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steelprimer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever required0.80 mm thick with zinc coating not less than 275 gm/m² |
| 158 | Providing and fixing precoated galvanised steel sheet roofing accessoriesof total coated thickness 0.50 mm (base metal of minimum 0.45 mmthickness with total coating thickness of 0.05 mm) with Zinc coating 120gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxyprimer on both side of the sheet and polyester top coat 15-18 micronsusing self drilling/ self tapping screws complete : |
| 159 | Ridges plain (500 - 600mm) |
| 160 | Flashings/ Aprons.( Upto 600 mm) |
| 161 | Gutter (600 mm over all girth) |
| 162 | Add 18 % GST (in Basic Rate must fill 12) |
| 163 | Add 1% Labour Cess (in Basic Rate must fill 1) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail