| 1 | SITC of 4-Zone DALI Lighting Controller with Keypads. (a) Supply, Installation, Testing & Commissioning (SITC) of 4-Zone Lighting Controller cum Dimmer with certified DALI protocol interface, to integrate with AV control processor. Controller shall support one loop controlling up to 64 DALI devices, supporting DT0, DT1, DT2, DT3, DT4, DT5, DT6, DT7, and DT8(Tc) DALI type devices.(b) Provision to connect external contact closures to set lighting levels and override devices for each zone. (c) Integration including two sets of button pads per controller, with capability to create multiple lighting modes and scenes. (d) Supply & integration license, application software, configuration, and commissioning. (e) Supply, installation, testing & commissioning of 5/8/10 Button International SeeTouch Keypadwith Master Raise/Lower functionality, fully integrated with lighting controllerComplete wiring, interconnection, termination, and integration with AV control processorincluding programming for scene control, button mapping, and communication verification. (f) Testing, commissioning, demonstration, and handing over with full documentation, manuals and warranty as per CPWD/ OEM specifications. |
| 2 | Supply, Installation, Testing & Commissioning (SITC) of 15W deep recessed DALI dimmable COB mounted downlighter with pressure die-cast aluminium heat sink and PC lens. Luminaire shall have photobiologically safe LED, high-performance LED driver with near-zero maintenance, no harmful UV or IR radiation, operating temperature -10°C to +45°C, operating voltage range 140–270V AC, power factor >0.90, THD <15%, CCT 4000K, CRI >80, fixture colour grey, system lumen output 3460 lm, average life L70B50: 50,000 hours.Luminaire to support DALI driver with high-transmittance special micro-reflector optics, lumenefficacy>120 lm/W, beam angle 55°, UGR <19, including all necessary wiring, DALI integration,and commissioning. Supply & installation of adjustable suspension mounting kit for luminaire, complete with height adjustment and all accessories for safe and firm mountingesting, commissioning, and handing over, including functional verification, DALI address programming, and integration with lighting control system. Make: Havells (Alina Deep Recessed 15W COB) or equivalent in Wipro/Philips. |
| 3 | Supply of DALI Dimmable Linear Recessed Fittings. Supply of DALI dimmable 49 mm (light emitting surface) width linear recessed standalone fitting made of extruded aluminium housing with UGR <19 diffuser. Fixture shall be office compliant with system efficacy ≥ 110 lm/W (SDCM <3), minimum system lumen output 2200 lm (downlight), maximum system wattage 20 W, beam angle 110–120°, CCT up to 5700K, CRI > 80,P20, IK02.Luminaire to have isolated DALI 2.0 driver with flyback topology in metal/plastic enclosure, PF>0.95, THD <5% at full load, operating voltage range 150–270V AC, internal surge protection 2KV.Luminaire life: 50,000 hrs @ L70B0 at 45°C ambient; compliance with IS10322. LM79 and LM80 reports from NABL/UL accredited lab to verify parameters. Manufacturer must have in-house lab approved by NABL or Ministry of Science, Govt. of India.Supply of 3-core 1.5 sq. mm interconnection cable for luminaire installation.Dimensions: 1200 × 49 × 86 mm (±2 mm); Make: Wipro LM34-251 (DALI), Havells DESTG250LP/S50WLED840SWH2260 or equivalent (LT/Philips).testing, commissioning, and handing over including functional verification, DALI addressprogramming, and integration with lighting control system. |
| 4 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 5 | Group C |
| 6 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 7 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 8 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 9 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 10 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 11 | 3 Module (100 mm X 75 mm) |
| 12 | 12 Module (200 mm X150 mm) |
| 13 | 6 Module ( 200 mm x 75 mm ) |
| 14 | 8 Module (125 mm x 125 mm) |
| 15 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 16 | 5/6 A switch |
| 17 | 15/16 A switch |
| 18 | 3 pin 5/6 A socket outlet |
| 19 | 6 pin 15/16 Amp socket outlet |
| 20 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required |
| 21 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 22 | 250 watt |
| 23 | Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium ReflectorLED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt ) 18 watt |
| 24 | Supplying, installation, testing and commissioning of 20 W LED track light, including testing etc., complete as required |
| 25 | Supplying, installation, testing and commissioning of 40 W LED COB strip light, with uniform illumination i/c aluminium channel with diffuse complete with driver, accessories, wiring, fixing, testing and commissioning, complete as required. |
| 26 | Supplying, installation, testing and commissioning of 40 W LED profile strip light with uniform illumination, i/c aluminium channel with diffuser, accessories, wiring, fixing and making electrical connections, complete as required. |
| 27 | Supplying installation testing and commissioning of 48 watt power supply for IP20 strip light etc., complete as required. Please Enable Macros to View BoQ information |