| 1 | Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : Decorative veneer facings of approved colour, grains , tectures etc. and of manufacture. |
| 2 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing,paneling and dash fasteners to be paid for separately) : |
| 3 | For fixed portion Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 4 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 5 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 6 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete,including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. : With cement mortar 1:4 (1 cement : 4 fine sand) |
| 7 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 8 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. : With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 9 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour : Two coats |
| 10 | Providing and appliying French spirit polishing : Two or more coats on new works including a coat of wood filler |
| 11 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 12 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor f inishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer in-charge. : With stainless steel cover plate minimum 1.25 mm thickness |
| 13 | Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/ structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600 |
| 14 | Upto 10 mm depth and 10 mm width |
| 15 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. |
| 16 | Granite stone slab of all colour and texture except black, Cherry/Ruby red : Area of slab upto 0.50 sqm |
| 17 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-Charge. |
| 18 | Granite work |
| 19 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 20 | Providing and fixing plain lining with necessary screws/nuts & bolts/ nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-in- charge (Frame work shall be paid for separately). : 12 mm thick commercial ply conforming to IS : 1328 BWR type |
| 21 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 22 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level Cement mortar 1:4 (1 cement :4 coarse sand) |
| 23 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). |
| 24 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 25 | Removal of existing PVC vynil carpet, cleaning the substart thoroughly, placing the removed carpet at the designated place and then providing , laying and fixing of 9.0 mm thk polypropelene based woolen carpet flooring with the adhesive as per manufactures specifications in rolls or in tiles to the required size etc. completed as directed ( The carpet must have acoustic properties suitable for reducing ambient noise and echo within the space. Surface should be evenly finished, well-woven, and free from defects.The bottom layer must be designed to withstand moisture from the flooring, ensuring durability and resistance to mold or degradation. Installation should be carried out on a clean, level surface using appropriate adhesives and tools as per manufacturer recommendations.) |
| 26 | Providing , laying and fixing of 25.0 mm thk. ready to use Accoustic wall panles in size 600 x 600 or 600* 1200 or 600* 1800 of approved colour, taxtutre, fabric etc . ( NRC to the tune of 0.85 ) of Armstrong / saint gobain or of an equivalant make , easy to install on the exiting wall to the required pattern , colour, texure of fabrics, surface finish and of approved make and design etc. to be fixed on the existing wooden / plywood / veneer / frame work substrate by approppriate adhesive or by suitable mechanical cleats / means etc. to be completed as per manufactures specifications and as directed. |
| 27 | Providing, supplying and fixing Stainless steel Door handles 24 \\" long of approved make |
| 28 | Supply and installation of manual fabric roller blinds of an an approved make , consisting of:• Aluminum tube of 35 mm diameter• Blackout fabric for light filtering• Manual operation with mono/PVC single chain and locking mechanism• Includes end caps, mounting brackets, and all necessary accessories and hardware |
| 29 | Dismantling and removing the existing aluminium sliding windows from the masonary wall with glazing and handing over the same. |
| 30 | Providing, supplying and fixing tempororry H frame metal scaffolding for carrying out external repair works etc. completed as directed. Please Enable Macros to View BoQ information |