| 1 | Construction of ACR Building for Gudvella Nodal UP Schooll |
| 2 | Earth work excavation of foundation trench in hard soil including dressing and levelling the bed with initial lead of 50m. and 1.5 m. initial lift including all costs of labour materials required for the work etc. complete and as per direction of Engineer in charge. |
| 3 | Filling foundation and plinth with sand well watered and rammed including cost, conveyance, royalty, taxes of all materials, labours and T & P required for the work etc. complete and as per direction of Engineer-in charge. |
| 4 | Cement concrete (1:4:8) with 4 cm. crusher Broken hard granite metal including laying in layers not exceeding 300 mm in depth, ramming, compacting to proper thickness, watering, curing for seven days with cost conveyance, royalty,taxes of all materials, labour and T&P required for the work etc. complete and as per direction of Engineer-in charge. |
| 5 | Reinforced cement concrete work of M-20 grade with 20mm & down grade size black hard crusher broken granite chips including hoisting and laying in position compacting to specified design section and curing for proper period with cost conveyance, royalty,taxes of all materials, labour and T&P required for the work etc. complete and as per direction of Engineer-in charge. Coloumn & base(a)Foundation & plinth |
| 6 | Brick work with Fly ash. Bricks in cement mortar (1:6) having crushing strength not less than 75.00 Kg/cm2 immerging the bricks in water not less than six hours with cost conveyance, royalty,taxes of all materials, labour and T&P required for the work etc. complete and as per direction of Engineer-in charge. (For Foundation & Plinth) |
| 7 | Brick work with Fly ash. Bricks in cement mortar (1:6) having crushing strength not less than 75.00 Kg/cm2 immerging the bricks in water not less than six hours with cost conveyance, royalty,taxes of all materials, labour and T&P required for the work etc. complete and as per direction of Engineer-in charge. (For Super structure) |
| 8 | Labour charges for cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge with cost of TATA TISCON/SAIL steel rod and as per drawing, design and direction of Engineer-in-charge. |
| 9 | Rigid smooth centering & shuttering for RCC works including false works and dismantling the same after required times etc. complete (a)Foundation and Plinth, Footing, Bases of columns, Mass concrete etc. |
| 10 | RCC Beams, Columns, Girders etc. |
| 11 | RCC Lintel |
| 12 | RCC Roof slab, Sunshades, Chajjas, Landing, Balconies up to 4.30 Mtr |
| 13 | Providing 20 mm thick CP(1:4) on roof slab with proper plumb and line watering curing for proper period with cost, conveyance, royality, taxes of all materials, labour and T & P required for the work etc. complete and as per direction of Engineer-in-charge. |
| 14 | 12mm thick cement plster (1:6) over Brick work including racking out joints finishing smooth with proper plumb and line curing for proper period with cost conveyance, royality, taxes of all materials, labour and T & P required for the work etc. comp.and as per direction of Engineer-in-charge.Up to 3mt ht |
| 15 | 16mm thick cement Plaster in CM (1:6) over brick work including racking out joints finishing smooth with proper plumb and line, curing for proper period with cost conveyance, royalty, taxes of all materials, labour and T & P required for the work etc comp.and as per direction of Engineer-in-charge.Up to 3mt ht |
| 16 | Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials labour T & P etc. as per direction of Engineer -In -charge. |
| 17 | Wall Painting two coats with any approved colour of weather seal coat over a coat of Water Bound Wall cement Primer to out side surface of wall in Ground Floor |
| 18 | Wall Painting two coats with any approved colour of weather seal coat over a coat of Water Bound Wall cement Primer to out side surface of wall in Ground Floor |
| 19 | Fixing vertified tiles in floors on 25mm thick bed of CM(1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing |
| 20 | Fixing vertified tiles in dados skirting and risers of steps on 12mm thick CP (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing |
| 21 | Fixing cheqered tiles in floors on 25mm thick bed of CM(1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing |
| 22 | Painting two coats with approved Enamel Paint on Steel surface over a coat of Red Oxide Primer in Ground Floor |
| 23 | Supplying fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 mtrs C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in staircase as per approved design and specification, buffing, polishing etc with coist, conveyance, taxes of all materials, labour and T&P required for the work all complete in all respect |
| 24 | Supplying fitting fixing supplying fixed M. steel and put up for frames of Doors and windows complete including painting one coat primer & fixing in position with cost conveyance, royality taxes of all materials & labours and T & P required for the work etc. complete and as per direction of Engineer-in-charge. |
| 25 | Provision for Black Board- 02 Nos |
| 26 | Provision for Rack- 02 Nos |
| 27 | Cost of Display Board(3'x4') in brick work |
| 28 | (Electrification works ) Recessed Modular wiring to Light/ Fan/ Call bell and Exhaust fan point with 1.5 mm2 F.R. PVC insulated single core multi strand copper conductor |of ISI marked with 50mm dia Non metallic with 20mm dia non metalic PVC flexible conduit with 5/6 250volt Modular type switch,ceilling rose mounted 1 on MS box having front bakelite cover of suitable SIze M.S box with 1.5mm2 FR pvc insuleted S/C multistand copper conductor as earth wire Including all accessories and connection.as per direction of Engineer-in-charge. (Make of wire Finolex/Anchore/ Havels/HPL/L&TI V.Guard & make of switch socket Legrand/ Hager/ L&T. Group -A |
| 29 | Group-B |
| 30 | Group-C |
| 31 | S/F of 5 A switch & socket on existing board |
| 32 | Circuit submain wiring in PVC conduit(Finolex/Anchor) (a) 2x1.5 sqmm+1x1.5 sqmm |
| 33 | 2x2.5 sqmm+1x1.5 sqmm |
| 34 | 2x4.0 sqmm+1x1.5 sqmm |
| 35 | S/F of BK angle holder |
| 36 | S/F of 48'' A.C. Ceiling Fan(Bajaj/Usha) |
| 37 | Supply of Ceiling Fan |
| 38 | S/F of 9 watt LED Bulb(Bajaj/Orient/Crompton) |
| 39 | S/F of 20 Watt LED batten fitting |
| 40 | S/F of 4 way MCB DB Single door |
| 41 | S/F of B Series SP MCB (Havels/HPL/Anchor) |
| 42 | S/F of 32 Amp DP Main switch (HPL/Anchor) |
| 43 | S/F of Standard Earthing |
| 44 | S/F of No 8 SWG Copper Wire Please Enable Macros to View BoQ information |