| 1 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15 mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/l. |
| 2 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 3 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 4 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 5 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/l. |
| 6 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 7 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 8 | Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shadecomplete. |
| 9 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles ofapproved make and colour using acid and/or alkali resisting mortarbedding, and joints filled with acid and/or alkali resisting cement as per IS: 4457, complete as per the direction of Engineer-in- Charge.. |
| 10 | Providing and laying in position specified grade of cement concrete,excluding the coat of centering and shuttering -All work up to -Plinth level: 1:1.5.3 (1 Cement : 1.5 Coarse sand (Zone iii) : 3 Graded stone aggregate 20mm nominal size ) |
| 11 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : |
| 12 | Taking down old door and window shutters including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 13 | Supplying, fitting and fixing 38mm , thick good quality well dressed and well seasoned sal wood battened shutters ledged and braced in doors and windows with oxidised iron fittings such as hinges, sliding door, bolts, tower bolts, handled or rings, hooks and eyes, cleats, sand blocks as per schedule, taxes and royalty all complete as per building specification and direction of E/I. |
| 14 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. |
| 15 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 16 | Providing two coats of synthetic enamel paint of apporoved shade and make over steel surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I. |
| 17 | Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 18 | Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm. Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I. |
| 19 | Supplying, and fixing fan hook of 16mm dia M.S. bar 1 meter long bent to required size and shape , placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 20 | Providing 250mm. wide brick drain in cement mortar (1:6) with av. 250mm. clear depth and 250mm. apron including cost of earthwork involved with 75 mm. ~ cement concrete (1:4:8) over one brick designation 75A flat soling in proper grade and slope at the base, the drain duly plastered in C.M.(1:3) with punning over exposed surface all complete as per building specification and direction of E/l. |
| 21 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 22 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 23 | Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling, ramming the foundation trenches, removing roots of trees shurbs all complete as per approved design building specification and direction of E/I. |
| 24 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B) |
| 25 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) |
| 26 | Providing designation 75Bwork in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I. |
| 27 | Providing and laying position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level. |
| 28 | 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40mm nominal size) |
| 29 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15\\" landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size). |
| 30 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 31 | Suspended Floors, roofs, landings, balconies and access platform |
| 32 | Lintels, beams, Plinth beams, girders, bressumers and cantilevers |
| 33 | Providing Toe steel reinforcement of following dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and Vizal Steel) |
| 34 | 10mm dia |
| 35 | 12mm dia |
| 36 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I |
| 37 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 38 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I. |
| 39 | Carriage of materials by diesel Truck including loading at source, unloading at works site and stacking properly, labour, P.O.L., etc. all complete as per direction of E/I. |
| 40 | Bricks - 8km (1k + 7p) |
| 41 | Sand - 20 km |
| 42 | Chips -20km |
| 43 | Local Sand - 3 km |
| 44 | Wiring for light/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FRPVC insulated copper conductor single core cable in surface/recessed PVC conduit with Modular Plate suitable G.I. box and earthing the point with 1.5 sq.mm. FRPVC insulated copper conductor single core cable etc. as required. |
| 45 | Group C |
| 46 | Wiring for light/power plug with 2 x 4 sq.mm FRPVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 No. sq.mm FRPVC insulated copper conductor single core cable for loop earthing as required |
| 47 | Wiring for Curcuit submain wiring along with earth wire with the following sizes of PVC insulated copper conductor single core cable in surface of recessed PVC sonduit as required |
| 48 | 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire |
| 49 | 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire |
| 50 | 4 x 6.0 sq.mm + 2 x 6.0sq.mm earth wire |
| 51 | S/F PVC conduit - Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required. |
| 52 | 20 mm |
| 53 | S/F Modular type switch socket - Supplying and fixing following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required |
| 54 | 5/6 amps, one way switch |
| 55 | 5/6 amps, 3 pin socket outlet |
| 56 | S/F Modular type electronic fan regulator -Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 57 | S/F suitable size G.I. box with modular plate and cover in front on surface or in recess including P.F. 3 pin 5/6 amp. Modular socket outlet and 5/6 amp. Modular switch connection painting etc. as required |
| 58 | S/F suitable size G.I. box with modular plate and cover in front on surface/recess including P/F 6 pin 15/16 amp. And 5/6 amp modular socket outlet and 15/16 amps. Modular switch connection as painting etc. as required |
| 59 | S/F brass vatton/Angle Holder including connection etc. as required |
| 60 | I.T.C of exhaust fan up to 450mm sweep in the existing opening including making the hole to suit the size of the above fan making good the damage connection testing commissioning etc. as required |
| 61 | Supplying and Fixing TPN MCB DB: Supplying and Fixing of following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder including painting, earthing etc. as required( without MCB/RCCB/ISOLATOR). Make :- Havells / Standard / indoasian. |
| 62 | 4+12 ways, double door Horizontal type (4 Way) |
| 63 | S/F 5 amp. To 32 amp rating 240 volt \\"C\\" series miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connection testing and commissioning etc. a srequired.6/32 amps, single pole \\"B\\" series |
| 64 | S/F four pole MCB isolator - Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioining etc. as required |
| 65 | 40 amp |
| 66 | 63 amp |
| 67 | Supply, Installation, testing and commissioning of following, size ceiling fan 3 Blades confirming to IS : 374 : 2019 including wiring the down rods of standard length (up to 30cm) with 1.5 sq.mm. FR PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as required. |
| 68 | 1200mm (48\\") ceiling Fan |
| 69 | S.I.T.C. of following rating, surface mounted LED light fitting, suitable for 230V 50Hz, single phase supply etc. complete as required. |
| 70 | 20/22W LED Tube Light |
| 71 | 15/16 Watt LED Bulb |
| 72 | 9/10Watt LED Bulb |
| 73 | 12\\" (300mm) metal exhaust fan |
| 74 | Providing and fixing male ended 15mm dia brass bib cock of approved quality (Wt. not less than 350 gms.) with extra socket all complere as per specification and direction of E/I. |
| 75 | Providing and fixing brass/C.I. stop cock of approved quality all complete as per specification and direction of E/I. |
| 76 | Providing and fixing 15mm dia and 45cm long PVC connection pipe with heavy quality brass coupling at both ends etc. all complete as per specification and direction of Engineer-in-charge. |
| 77 | Providing and fixing 15mm size C.P. brass pillar cock (Weight not less than 350gms.) C.I. body brass spindle pillar cock of approved quality as per specification and direction of E/I. |
| 78 | C.I. body brass spindle |
| 79 | Providing and fixing Gun metal full way valve of approved quality all complete as per specification and direction of E/I. |
| 80 | 25mm dia |
| 81 | Making holes in walls for laying G.I. pipes and restoring the same after pipe laying as per specification and direction of E/I. |
| 82 | 125mm thick wall |
| 83 | 250mm thick wall |
| 84 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. |
| 85 | Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror - 450mm x 300mm |
| 86 | C.P. brass soap dish container medium quality with screw and hinges etc. |
| 87 | Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stop cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and dirction of E/I. |
| 88 | 580mm long - With 10 liter low level PVC cistern |
| 89 | Supplying fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I. brass waste, 15mm dia C.I. body brass spindl stop cock approved quality of weight not less than 30 grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I. |
| 90 | Lbour for alying, fitting and fixing NP2 R.C.C. spun pipe with colars in lines, level and grade and providing approved jointing materials and joints properly filled to make them leakproof including providing sight rails, bonning rod, night guard, Red light and barrier etc. all complet as per specification and direction of E/I.150mm dia RCC spun pipe - Upto 3.0 metre depth of invert below G.L. |
| 91 | Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I. |
| 92 | Supplying and fixing NP2 Hume pipe etc. (150mm dia) |
| 93 | Special type C.P. Bath room Fitting for V.I.P.Buildings(JAL, Jaquar, Mark or Equivalent) |
| 94 | Bib cock (2 Way) |
| 95 | Angular Stop Cock |
| 96 | Pressure Adjustable Shower with revolving joint (Health Façade) |
| 97 | Providing and fixing on wall face unplasticied Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion (i) Single socketed pipes. |
| 98 | 75 mm |
| 99 | 110 mm |
| 100 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 101 | Single tee with door - 75x75x75 mm |
| 102 | Single tee without door - 110x110x110 mm |
| 103 | Bend 87.5° - 75mm |
| 104 | Bend 87.5° - 110mm |
| 105 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall |
| 106 | 25 mm nominal outer dia Pipes |
| 107 | 32 mm nominal outer dia Pipes |
| 108 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. |
| 109 | 15 mm nominal outer dia Pipes |
| 110 | 20 mm nominal outer dia Pipes |
| 111 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 112 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 113 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 114 | Costs of drilling 200mm*165mm*125mtr. Deep borewell in all kinds of soil and rock in rural area for installation of pump set with Hydraulic DTH rig machines, all complete including supplying all materials , tools ,drilling rig, Air compressor and equipments as well as fuel lubricants and cost of transportation of rig machine and other vehicles upto the site. |
| 115 | From 0-50 mtr |
| 116 | Above 51 mtr to 125 mtr |
| 117 | Above 125 mtr |
| 118 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings& accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 119 | 200 mm nominal size dia |
| 120 | Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 121 | Providing & fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing /casing pipe, removable as per requirement all complete for borewell of 200mm dia |
| 122 | Providing and fixing ISI marked 85x42 mm oxidised M.S. pull bolt lock conforming to IS : 7534 with necessary screws bolts, nut and washers etc. complete (Copper oxidised as per IS 1378). |
| 123 | Providing and fixing bail plug/botton plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800(Part -1) 200 mm dia |
| 124 | Supplying submersible pumps sets conforming to IS:8034 and motor conforming to IS:9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller, motor suitable for working on 415 V+10%,3PH.50 HZ,AC supply with cable guard ,thrust carbon/fiber bearing to withstand entire hydraulic thrust ,water proof winding shall be provided the pump set shall be suitable for direct couplings, pump shall have suitable outlet as per manufacture design. Anti thrust stream lined non returned valve shall be provided with pump .3 mtr submersible copper conductor cable in single/double run shall be provided with each pump. |
| 125 | Submersible pump set 100 mm dia ( with polypropylene/impeller) upto 20 stage-2 HP |
| 126 | Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes , all complete job as per direction of E/I. |
| 127 | Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I. |
| 128 | Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I. |
| 129 | Add 18 % GST (in Basic Rate must fill 12) |
| 130 | Add 1% Labour Cess (in Basic Rate must fill 1) Please Enable Macros to View BoQ information |